west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "simulation" 81 results
  • Design and Implementation of the Pulse Wave Generator with Field Programmable Gate Array Based on Windkessel Model

    Pulse waves contain rich physiological and pathological information of the human vascular system. The pulse wave diagnosis systems are very helpful for the clinical diagnosis and treatment of cardiovascular diseases. Accurate pulse waveform is necessary to evaluate the performances of the pulse wave equipment. However, it is difficult to obtain accurate pulse waveform due to several kinds of physiological and pathological conditions for testing and maintaining the pulse wave acquisition devices. A pulse wave generator was designed and implemented in the present study for this application. The blood flow in the vessel was simulated by modeling the cardiovascular system with windkessel model. Pulse waves can be generated based on the vascular systems with four kinds of resistance. Some functional models such as setting up noise types and signal noise ratio (SNR) values were also added in the designed generator. With the need of portability, high speed dynamic response, scalability and low power consumption for the system, field programmable gate array (FPGA) was chosen as hardware platform, and almost all the works, such as developing an algorithm for pulse waveform and interfacing with memory and liquid crystal display (LCD), were implemented under the flow of system on a programmable chip (SOPC) development. When users input in the key parameters through LCD and touch screen, the corresponding pulse wave will be displayed on the LCD and the desired pulse waveform can be accessed from the analog output channel as well. The structure of the designed pulse wave generator is simple and it can provide accurate solutions for studying and teaching pulse waves and the detection of the equipments for acquisition and diagnosis of pulse wave.

    Release date: Export PDF Favorites Scan
  • Simulation Prediction of Bone Defect Repair Using Biodegradable Scaffold Based on Finite Element Method

    Aiming at the problem of scaffold degradation in bone tissue engineering, we studied the feasibility that controlls bone defect repair effect with the inhomogeneous structure of scaffold. The prediction model of bone defect repair which contains governing equations for bone formation and scaffold degradation was constructed on the basis of analyzing the process and main influence factors of bone repair in bone tissue engineering. The process of bone defect repair and bone structure after repairing can be predicted by combining the model with finite element method (FEM). Bone defect repair effects with homogenous and inhomogeneous scaffold were simulated respectively by using the above method. The simulation results illustrated that repair effect could be impacted by scaffold structure obviously and it can also be controlled via the inhomogeneous structure of scaffold with some feasibility.

    Release date: Export PDF Favorites Scan
  • Research progress in computational fluid dynamics simulation of alveolar airflows

    Due to their diverse types, complex causes, high incidence, and difficult treatment, lung diseases have become major killers threatening human life and health, and some lung diseases have a significant impact on alveolar morphology and histology. Numerical simulation of alveolar mechanical response, alveolar flow field information, multiphase flow, and material transport based on computational fluid dynamics is of great significance for lung disease diagnosis, clinical treatment, and in vitro experiments. Starting from the simplification and pathological differences of geometric and mechanical models, this paper analyzes and summarizes the conditions and application scenarios of the airflow dynamics calculation method in pulmonary alveoli, to provide a reference for further simulation and application of the alveolar region.

    Release date:2023-08-24 10:24 Export PDF Favorites Scan
  • Numerical study on the mechanical coupling of external vascular stent and vein graft in coronary artery bypass surgery

    External support stent is a potential means for restricting the deformation and reducing wall stress of the vein graft, thereby improving the long-term patency of the graft in coronary artery bypass surgery. However, there still lacks a theoretical reference for choosing the size of stent based on the diameter of graft. Taking the VEST (venous external support) stent currently used in the clinical practice as the object of study, we constructed three models of VEST stents with different diameters and coupled them respectively to a model of the great saphenous vein graft, and numerically simulated the expansion-contraction process of the vein graft under the constraint of the stents to quantitatively evaluate the influence of stent size on the radial deformation and wall stress of the vein graft. The results showed that while the stent with a small diameter had a high restrictive effect in comparison with larger stents, it led to more severe concentration of wall stress and sharper changes in radial deformation along the axis of the graft, which may have adverse influence on the graft. In order to solve the aforementioned problems, we ameliorated the design of the stent by means of changing the cross-sectional shape of the thick and thin alloy wires from circle into rectangle and square, respectively, while keeping the cross-sectional areas of alloy wires and stent topology unchanged. Further numerical simulations demonstrated that the ameliorated stent evidently reduced the degrees of wall stress concentration and abrupt changes in radial deformation, which may help improve the biomechanical environment of the graft while maintaining the restrictive role of the stent.

    Release date:2021-02-08 06:54 Export PDF Favorites Scan
  • Finite element simulation of stent implantation and its applications in the interventional planning for hemorrhagic cardio-cerebrovascular diseases

    Numerical simulation of stent deployment is very important to the surgical planning and risk assess of the interventional treatment for the cardio-cerebrovascular diseases. Our group developed a framework to deploy the braided stent and the stent graft virtually by finite element simulation. By using the framework, the whole process of the deployment of the flow diverter to treat a cerebral aneurysm was simulated, and the deformation of the parent artery and the distributions of the stress in the parent artery wall were investigated. The results provided some information to improve the intervention of cerebral aneurysm and optimize the design of the flow diverter. Furthermore, the whole process of the deployment of the stent graft to treat an aortic dissection was simulated, and the distributions of the stress in the aortic wall were investigated when the different oversize ratio of the stent graft was selected. The simulation results proved that the maximum stress located at the position where the bare metal ring touched the artery wall. The results also can be applied to improve the intervention of the aortic dissection and the design of the stent graft.

    Release date:2021-02-08 06:54 Export PDF Favorites Scan
  • Research progress of digital occlusion setup in orthognathic surgery

    ObjectiveTo review the research progress of digital occlusion setup in orthognathic surgery. Methods The literature related to digital occlusion setup in orthognathic surgery in recent years was consulted, and the imaging basis, methods, clinical applications as well as existing problems were reviewed. Results Digital occlusion setup in orthognathic surgery includes manual, semi-automatics, and fully automatic methods. The manual method mainly relies on visual cues for operation, which is difficult to ensure the best occlusion set up, though relatively flexible. The semi-automatic method utilizes the computer software for partial occlusion set up and adjustment, but the occlusion result is still largely depended by manual operation. The fully automatic method completely depends on the operation of computer software, and targeted algorithms for different occlusion reconstruction situations are needed. Conclusion The preliminary research results have confirmed the accuracy and reliability of digital occlusion setup in orthognathic surgery, but there are still some limitations. Further research is needed in terms of postoperative outcomes, doctor and patient acceptance, planning time and cost-effectiveness.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
  • Research on Optimization of Lower Limb Parameters of Cardiopulmonary Resuscitation Simulation Model Based on Genetic Algorithm

    Sudden cardiac arrest is one of the critical clinical syndromes in emergency situations. A cardiopulmonary resuscitation (CPR) is a necessary curing means for those patients with sudden cardiac arrest. In order to simulate effectively the hemodynamic effects of human under AEI-CPR, which is active compression-decompression CPR coupled with enhanced external counter-pulsation and inspiratory impedance threshold valve, and research physiological parameters of each part of lower limbs in more detail, a CPR simulation model established by Babbs was refined. The part of lower limbs was divided into iliac, thigh and calf, which had 15 physiological parameters. Then, these 15 physiological parameters based on genetic algorithm were optimized, and ideal simulation results were obtained finally.

    Release date: Export PDF Favorites Scan
  • Equivalent Lever Principle of Ossicular Chain and Amplitude Reduction Effect of Internal Ear Lymph

    This paper makes persuasive demonstrations on some problems about the human ear sound transmission principle in existing physiological textbooks and reference books, and puts forward the authors' view to make up for its literature. Exerting the knowledge of lever in physics and the acoustics theory, we come up with an equivalent simplified model of manubrium mallei which is to meet the requirements as the long arm of the lever. We also set up an equivalent simplified model of ossicular chain--a combination of levers of ossicular chain. We disassemble the model into two simple levers, and make full analysis and demonstration on them. Through the calculation and comparison of displacement amplitudes in both external auditory canal air and internal ear lymph, we may draw a conclusion that the key reason, which the sound displacement amplitude is to be decreased to adapt to the endurance limit of the basement membrane, is that the density and sound speed in lymph is much higher than those in the air.

    Release date: Export PDF Favorites Scan
  • Research progress overview and prospects of post-disaster psychological first aid training based on virtual simulation technology

    With the post-disaster psychological crisis has aroused wide attention, psychological first aid which can relieve psychological trauma and prevent post-traumatic disorder has been valued by many countries. However, mainly domestic psychological first aid training is simply theoretical training while its popularizing rate is low, it is urgent to learn from international experience to carry out more effective psychological first aid training. In the context of combination of medicine and industry, the paper majorly embodied virtual simulation’s potential in improving psychological intervention ability, deep learning level and self-efficacy. Furthermore, the paper analyzed and illustrated theoretical basis and function module of constructing psychological first aid training platform in detail, and prospected further improvement, which laid foundations for follow-up studies.

    Release date:2024-11-27 02:45 Export PDF Favorites Scan
  • Angiodynamic and optical coupling analysis of skin tissue model under finite pressure

    The pulse amplitude of fingertip volume could be improved by selecting the vascular dense area and applying appropriate pressure above it. In view of this phenomenon, this paper used Comsol Multiphysics 5.6 (Comsol, Sweden), the finite element analysis software of multi-physical field coupling simulation, to establish the vascular tissue model of a single small artery in fingertips for simulation. Three dimensional Navier-Stokes equations were solved by finite element method, the velocity field and pressure distribution of blood were calculated, and the deformation of blood vessels and surrounding tissues was analyzed. Based on Lambert Beer's Law, the influence of the longitudinal compression displacement of the lateral light surface region and the tissue model on the light intensity signal is investigated. The results show that the light intensity signal amplitude could be increased and its peak value could be reduced by selecting the area with dense blood vessels. Applying deep pressure to the tissue increased the amplitude and peak of the signal. It is expected that the simulation results combined with the previous experimental experience could provide a feasible scheme for improving the quality of finger volume pulse signal.

    Release date:2022-08-22 03:12 Export PDF Favorites Scan
9 pages Previous 1 2 3 ... 9 Next

Format

Content