With the upgrading of minimally invasive surgical concepts and laparoscopic equipment for gastric cancer, single-incision laparoscopic surgery (SILS) had emerged as a new focus of research in gastric cancer surgery. SILS offered advantages such as reduced damage, superior cosmetic outcomes, decreased postoperative pain, and faster recovery as compared with traditional laparoscopic gastrectomy. However, its level of difficulty limited its further promotion and application. Although numerous studies supported the safety and feasibility of SILS, more high-level evidence-based medical research was required to endorse its widespread use. The author reviewed the development history, current status, and prospects of SILS laparoscopic gastric cancer surgery.
Objective To investigate the early effectiveness of transiliac-transsacral screws internal fixation assisted by augmented reality navigation system HoloSight (hereinafter referred to as “computer navigation system”) in the treatment of posterior pelvic ring injuries. MethodsA retrospective analysis was made in the 41 patients with posterior pelvic ring injuries who had been treated surgically with transiliac-transsacral screws between June 2022 and June 2023. The patients were divided into navigation group (18 cases, using computer navigation system to assist screw implantation) and freehand group (23 cases, using C-arm X-ray fluoroscopy to guide screw implantation) according to the different methods of transiliac-transsacral screws placement. There was no significant difference in gender, age, body mass index, causes of injuries, Tile classification of pelvic fracture, days from injury to operation, usage of unlocking closed reduction technique between the two groups (P>0.05). The time of screw implantation, the fluoroscopy times, the guide wire adjustment times of each screw, and the incidence of complications were recorded and compared between the two groups. The position of the transiliac-transsacral screw was scanned by CT within 2 days after operation, and the position of the screw was classified according to Gras standard. ResultsThe operation was successfully completed in both groups. The time of screw implantation, the fluoroscopy times, and the guide wire adjustment times of each screw in the navigation group were significantly less than those in the freehand group (P<0.05). There were 2 cases of incision infection in the freehand group, and the incision healed by first intention after active dressing change; there was no screw-related complication in the navigation group during operation and early period after operation; the difference in incidence of complications between the two groups (8.7% vs. 0) was not significant (P=0.495). According to the Gras standard, the screw position of the navigation group was significantly better than that of the freehand group (P<0.05). ConclusionCompared with the traditional freehand method, the computer navigation system assisted transiliac-transsacral screws internal fixation in the treatment of posterior pelvic ring injuries has advantages of improving the accuracy of screw implantation and reducing radiation damage and the time of screw implantation.
ObjectiveTo understand the psychological pressure when the surgeon-in-chief remotely completes animal surgery using home-made Tumai surgical robot in combination with 5G network (Abbreviated as“remote robotic surgery” ), and investigate and analyze the sources of psychological pressure, and then provide evidence guidance for the training of surgeon in performing remote robotic surgery. MethodsA modified perceptual stress scale was used to conduct a questionnaire survey. The 44 surgeons-in-chief with robot operation qualification from 10 medical units in the Gansu Province recruited by Gansu Provincial People’s Hospital were as observation subject, who participated in the psychological stress validation test of remote robotic surgery, from September 4, 2022 to October 10, 2022. The difference of psychological stress before and after the test was compared. The stressor of surgeon-in-chief was analyzed by Likert scale. The animals in this study were swines. ResultsA total of 132 valid questionnaires were obtained from 44 surgeons-in-chief. The surgical physician’s perceived stress score after the test was statistically higher than before the test [(47.50±9.06) points vs. (38.34±5.55) points, mean difference and its 95% confidence interval=9.61 (7.00, 12.27), t=7.42, P<0.001]. The analysis results of multiple linear regression showed that the number of robotic surgery performed by the surgeon-in-chief in the past had a negative impact on the psychological pressure of the surgeon-in-chief after the test (β=–0.292, P=0.042); At the same time, the subjective perception data of the surgeon-in-chief, such as unstability of signal transmission and unskilled equipment manipulation by the surgeon had positive impacts on the psychological pressure of the surgeon-in-chief after the test (β=1.987, P=0.026; β=3.184, P=0.010), and the tacit understanding between the surgeon-in-chief and the first assistant had a negative impact on the psychological pressure of the surgeon-in-chief after the test (β=–2.185, P=0.047). ConclusionsAccording to the data from this study, remote robotic surgery will increase the psychological pressure of the surgeon-in-chief. Previous experience in robotic surgery can reduce psychological stress after surgery. The main sources of psychological pressure are unstability of signal transmission, unskilled equipment manipulation by the surgeon, and the tacit understanding between the surgeon-in-chief and the first assistant.
Minimally invasive cardiac surgeries are the trend in the future. Among them, robotic cardiac surgery is the latest iteration with several key-hole incision, 3-dimentional visualization, and articulated instrumentation of 7 degree of ergonomic freedom for those complex procedures in the heart. In particular, robotic mitral valve surgery, as well as coronary artery bypass grafting, has evolved over the last decade and become the preferred method at certain specialized centers worldwide because of excellent results. Other cardiac procedures are in various stages of evolution. Stepwise innovation of robotic technology will continue to make robotic operations simpler, more efficient, and less invasive, which will encourage more surgeons to take up this technology and extend the benefits of robotic surgery to a larger patient population.
ObjectiveTo create a new scleral buckling surgery using noncontact wide-angle viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment (RRD), and to evaluate its safety and effectiveness. MethodsA scleral buckling surgery using noncontact wide-angle viewing system and 23-gauge intraocular illumination was performed in 6 eyes of 6 patients with RRD, including 2 males and 4 females. The mean age was 51 years old with a range from 23 to 66 years old. Proliferative vitreoretinopathy (PVR) were diagnosed of grade B in all 6 eyes. Duration of retinal detachments until surgery was 5.8 days with a range from 2 to 13 days. The mean preoperative intraocular pressure (IOP) was 12 mmHg with a range from 9 to 15 mmHg (1 mmHg=0.133 kPa). A 23-gauge optic fiber was used to provide an intraocular illumination. Fully examination of the ocular fundus and cryoretinopexy of retinal breaks was performed under a noncontact wide-angle viewing system. Subretinal fluid drainage through the sclerotomy and buckling procedure were performed under the operating microscope. Intravitreal injection of sterile air bubble was performed in 4 eyes. Antibiotic eye drops was applied in all eyes postoperatively, and all the eyes were followed up for at least 6 months. ResultsRetinal reattachment was achieved in all eyes, and the conjunctiva healed well. The best corrected visual acuity (BCVA) increased in all eyes. The mean postoperative IOP was 15 mmHg with a range from 12 to 19 mmHg. No complications were found intra and postoperatively. ConclusionsThis new scleral buckling surgery using noncontact wide-angle viewing system and 23-gauge intraocular illumination for RRD is safe and effective. Advantages such as higher successful rate, less complication, shorter operating time, and less discomfort of patients were showed comparing with the previous scleral buckling surgery using indirect ophthalmoscope.
ObjectiveTo analyze the feasibility and effectiveness of elastic intramedullary nail fixation for the fifth metacarpal neck fracture under the guidance of high frequency ultrasound.MethodsThe clinical data of 30 patients with the fifth metacarpal neck fractures who were treated with elastic intramedullary nails fixation under the guidance of high frequency ultrasound and met the selection criteria between May 2013 and September 2017 were retrospectively analysed. There were 24 males and 6 females, the age ranged from 18 to 58 years, with an average of 31.4 years. The head-shaft angle of the fifth metacarpal was (55.6±11.3)°. The time from injury to operation was 12 hours to 8 days, with an average of 2.4 days. The operation time, number of intraoperative fluoroscopy, fracture reduction, complications, and fracture healing time were recorded. The head-shaft angle of the fifth metacarpal on the affected side after fracture healing were measured and compared with the healthy side. At last follow-up, the active range of motion of the fifth metacarpophalangeal joint of both sides were measured, and the function was evaluated by using the total active movement (TAM) evaluation standard of the Hand Surgery Association of Chinese Medical Association.ResultsThe operation time was 22-40 minutes, with an average of 32.4 minutes; the intraoperative fluoroscopy was performed once; ultrasound images and X-ray fluoroscopy showed that the fracture was well reduced and no adjustment was required. The incisions healed well after operation, without tendon adhesion or local numbness. All 30 patients were followed up 8-16 months, with an average of 11.7 months. The fracture healing time was 4-8 weeks, with an average of 5.6 weeks. The head-shaft angle of the fifth metacarpal was (13.2±1.4)°, which was significantly improved when compared with preoperative value (t=−20.02, P=0.00); and there was no significant difference (t=1.94, P=0.06) when compared with the healthy side [(12.6±1.0)°]. At last follow-up, the active range of motion of the fifth metacarpophalangeal joint on the affected side was (89.4±2.4)°, showing no significant difference (t=−1.58, P=0.13) when compared with the healthy side [(90.3±2.0)°]. According to the TAM evaluation standard of the Hand Surgery Association of Chinese Medical Association, all patients were considered to be excellent.ConclusionThe effectiveness of elastic intramedullary nail fixation for the fifth metacarpal neck fracture under the guidance of high frequency ultrasound is definite. It can dynamically observe the fracture reduction from different angles, reduce ionizing radiation and postoperative complications.
ObjectiveTo summarize the minimally invasive experiences and medium-long-term results of perventricular device closure of ventricular septal defects (VSD) under transesophageal echocardiography (TEE) guidance.MethodsWe retrospectively analyzed the clinical data and medium-long-term follow-up results of 783 patients who undertook perventricular device closure under TEE guidance in Dalian Children’s Hospital from July 2011 to January 2020, in which perimembrane VSD were found in 598 patients, VSD with aortic valve prolapse in 135 patients and muscular VSD in 2 patients. There were 463 males and 320 females at age of 5 months to 13 years with average age of 3.3±1.2 years, and body weight of 5.9-51.0 (15.9±8.3) kg. The left ventricular defect diameter of the VSD ranged from 5.0 to 11.0 mm, with an average of 6.3±1.2 mm. The right ventricular defect diameter of the VSD ranged from 2.3 to 8.0 mm, with an average of 4.3±0.9 mm.ResultsThe procedures were completed successfully in 753 patients. The device of 1 patient (0.1%) fell off and embedded in the right pulmonary artery after the operation, and the occluder was taken out and the VSD was closed with cardiopulmonary bypass (CPB) in the secondary operation. One patient (0.1%) appeared Ⅲ degree atrioventricular block in 2 years after operation. The device was taken out and VSD was closed with CPB in the secondary operation, and the patient gradually reached to sinus rhythm in post-operation. Eight patients (1.1%) presented delayed pericardial effusion in 1 week after operation, and were cured by pericardiocentesis with ultrasound-guided. Symmetric occluders were used in 580 patients, eccentric occleders were used in 171 patients and muscular occluders were used in 2 patients. The follow-up time was 9 months to 9 years. The rate of loss to follow-up was 96.7% (704/728). No residual shunt, occlude-loss or arrhythmia was found during follow-up. Conclusion The minimally invasive penventricular device closure of VSD guided by TEE is safe and availabe. Medium-long-term follow-up results are satisfactory, it is worthy of clinical promotion, and longer term follow-up is still needed.
ObjectiveTo compare the effectiveness of lateral approach minimally invasive plate osteosynthesis (MIPO) and helical plate MIPO in the treatment of proximal humeral shaft fractures. Methods The clinical data of patients with proximal humeral shaft fractures who underwent MIPO via lateral approach (group A, 25 cases) and MIPO with helical plate (group B, 30 cases) between December 2009 and April 2021 were retrospectively analyzed. There was no significant difference in gender, age, injured side, cause of injury, American Orthopaedic Trauma Association (OTA) fracture classification, and time from fracture to operation between the two groups (P>0.05). The operation time, intraoperative blood loss, fluoroscopy times, and complications were compared between two groups. The angular deformity and the fracture healing were evaluated according to anteroposterior and lateral X-ray films postoperatively. The modified University of California Los Angeles (UCLA) score for shoulder and the Mayo Elbow Performance (MEP) score for elbow were analyzed at last follow-up. Results The operation time in group A was significantly shorter than that in group B (P<0.05). However, the intraoperative blood loss and fluoroscopy times presented no significant difference between the two groups (P>0.05). All patients were followed up 12-90 months, with an average of 19.4 months. There was no significant difference in follow-up time between the two groups (P>0.05). In terms of the quality of postoperative fracture reduction, there were 4 (16.0%) and 11 (36.7%) patients with angulation deformity in group A and group B, respectively, and there was no significant difference in the incidence of angulation deformity (χ2=2.936, P=0.087). All fractures achieved bony union, there was no significant difference in fracture healing time between group A and group B (P>0.05); delayed union occurred in 2 cases and 1 case in group A and group B, respectively (healing time was 30, 42, and 36 weeks after operation, respectively). In group A and group B, 1 patient had superficial infection of incision, respectively; 2 patients and 1 patient had subacromial impact after operation, respectively; and 3 patients in group A had symptoms of radial nerve paralysis of different degrees; all of them were cured after symptomatic treatment. The overall complication incidence of group A (32%) was significantly higher than that of group B (10%) (χ2=4.125, P=0.042). At last follow-up, there was no significant difference in the modified UCLA score and MEPs score between the two groups (P>0.05). Conclusion Both lateral approach MIPO and helical plate MIPO can achieve satisfied effectiveness in the treatment of proximal humeral shaft fractures. Lateral approach MIPO may be beneficial to shorten the operation time, while the overall complication incidence of helical plate MIPO is lower.
Objective To evaluate the effectiveness and feasibility of a transverse small incision intrathecal “loop” minimally invasive suture for acute Achilles tendon rupture. Methods The clinical data of 30 patients with acute Achilles tendon rupture treated with transverse small incision intrathecal “loop” minimally invasive suture between January 2022 and October 2023 was retrospectively analyzed. The patients were all male, aged from 29 to 51 years, with an average of 39.8 years. The cause of injury was acute sports injury, and the time from injury to operation was 1-14 days, with an average of 3.4 days. The operation time, incision length, intraoperative blood loss, intraoperative complications, wound healing, and hospital stay were recorded. Postoperative appearance and function of ankle were evaluated by American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, Vancouver Scar Scale (VSS) score, and Arner-Lindholm score. Results The operation time ranged from 30 to 90 minutes, with an average of 54.2 minutes; the incision length ranged from 1.3 to 3.5 cm, with an average of 2.2 cm; the intraoperative blood loss ranged from 5 to 70 mL, with an average of 22.3 mL; and the hospital stay ranged from 2 to 6 days, with an average of 3.7 days. All incisions healed by first intention, and there was no incision infection, poor healing, and deep venous thrombosis. All patients were followed up 5.3-22.0 months (mean, 14.7 months). During the follow-up, all the 30 patients had returned to exercise, and there was no complication such as Achilles tendon re-rupture, postoperative infection, and gastrocnemius muscle injury. At last follow-up, the AOFAS ankle-hindfoot score was 82-100, with an average of 95.1; the VSS score was 1-4, with an average of 2.1; according to the Arner-Lindholm score, 24 cases were rated as excellent and 6 cases as good. Conclusion Transverse small incision intrathecal “loop” minimally invasive suture for the treatment of acute Achilles tendon rupture has the advantages of simple instrument, convenient operation, small trauma, quick recovery, and satisfactory effectiveness.
ObjectiveTo compare the surgical effects of totally thoracoscopic and thoracoscopic-assisted small incision for left atrial appendage clipping. Methods The clinical data of patients who underwent left atrial appendage clipping surgery via totally thoracoscopy or thoracoscopic-assisted minimally invasive small incision from November 2018 to March 2022 in Beijing Tiantan Hospital were retrospectively analyzed. According to the surgical approach, they were divided into a totally thoracoscopic group and a small incision group. The clinical results were compared between the two groups. ResultsA totoal of 41 patients were enrolled, including 30 males and 11 females, with an average age of 66.6±6.1 years. There were 23 patients in the totally thoracoscopic group and 18 patients in the small incision group. The CHA2DS2-VASc score was 4.5±1.1 points, and HAS-BLED score was 3.7±1.5 points. No death occured in the whole group. There was no statistical difference between the two groups in terms of operation time, chest complications, successful rate of closure of the left atrial appendage, residual length of the left atrial appendage, or displacement of the atrial appendage clip (P>0.05). The total drainage volume in the totally thoracoscopic group was less than that in the small incision group, and the difference was statistically significant (P=0.031). The median follow-up time was 10 (1-30) months, during which there was 1 patient of stroke and 1 patient of left atrial thrombus in both groups. ConclusionTotally thoracoscopic left atrial appendage clipping is less invasive than thoracoscopic-assisted minimally invasive small incision surgery and does not increase the risk of surgical complications.