find Keyword "laminoplasty" 22 results
  • EFFECTIVENESS ANALYSIS OF Vertex ROD-SCREW SYSTEM IN CERVICAL EXPANSIVE OPEN-DOOR LAMINOPLASTY

    Objective To evaluate the cl inical appl ication value and short-term results of Vertex rod-screw system in cervical expansive open-door laminoplasty. Methods Between February 2008 and January 2010, 28 patients underwent Vertex rod-screw system fixation in cervical expansive open-door laminoplasty, including 15 cases of cervical spondylotic myelopathy, 5 cases of ossification of posterior longitudinal l igament,and 8 cases of cervical spondylosis with spinal stenosis. There were 16 males and 12 females, aged 42-77 years (mean, 61.3 years). The disease duration was 2 months to 11 years. The decompression range of cervical spine was from C3 to C7. The operation time, blood loss, Japanese Orthopedic Association (JOA) scores, and incidence of axial symptom were recorded. Pre- and postoperative curvature angles were demonstrated by the cross angle between posterior vertebral body margins of C2 and C7 on cervical X-ray films. The angle of the opened laminae was measured on CT scan at last follow-up. Results The operation time was (142.5 ± 22.8) minutes, and the blood loss was (288.2 ± 55.1) mL. All incisions healed by first intention. All patients were followed up 14-25 months (mean, 22 months). CT showed that no reclosed open-laminae or loosening and breakage of rod-screw system occurred at 1 week and 1 year after operation. The axial bony fusion rate was 89.3% (25/28). The improvement rate of JOA scores at 1 week after operation (29.5% ± 15.0%) was significantly smaller than that at 1 year after operation (64.9% ± 28.1%) (t=0.810, P=0.000). No case presented with C5 nerve root palsy. The cervical curvature angle was (24.29 ± 5.04)° before operation, was (23.89 ± 3.57)° at 1 week, and was (23.41 ± 3.35)° at 1 year after operation, showing no significant difference between pre- and postoperative angles (P gt;0.05). The angle of the opened laminae was (27.90 ± 4.74)° at 1 week after operation, and was (28.07 ± 4.21)° at 1 year after operation, showing no significant difference (P gt; 0.05). Conclusion Vertex rod-screw system in cervical expansive opendoor laminoplasty is effective in preventing reclosed open-laminae, which can reduce the loss of cervical curvature angle.

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
  • COMPARATIVE STUDY ON MICROPLATE AND ANCHOR FIXATION IN OPEN-DOOR CERVICAL EXPANSIVE LAMINOPLASTY

    Objective To evaluate the effectiveness of microplate fixation in open-door cervical expansive laminoplasty (ELP) by comparing with anchor fixation. Methods Between January 2005 and October 2008, 35 patients with multi-segment cervical spondylotic myelopathy were treated. Of them, 15 patients underwent ELP by microplate fixation (microplate group) and 20 patients underwent ELP by anchor fixation (anchor group). In microplate group, there were 10 malesand 5 females with the age of (51.2 ± 11.5) years; the disease duration ranged from 6 to 60 months (mean, 14 months); and the preoperative Japanese Orthopoaedic Association (JOA) score was 7.7 ± 2.5. In anchor group, there were 13 males and 7 females with the age of (50.7 ± 10.8) years; the disease duration ranged from 3 to 58 months (mean, 17 months); and the preoperative JOA score was 7.8 ± 2.9. There was no significant difference in the general data, such as gender, age, and JOA score between 2 groups (P gt; 0.05). Results All incisions healed by first intention. Thirty-five cases were followed up 24-68 months (mean, 32 months). The operation time was (113 ± 24) minutes in anchor group and (111 ± 27) minutes in microplate group, showing no significant difference (t=0.231 3, P=0.818 5). The rate of spinal canal expansion in microplate group (60% ± 24%) was significantly higher than that in anchor group (40% ± 18%) (t=2.820, P=0.008). The JOA scores of 2 groups at 3 months and 24 months after operation were significantly higher than the preoperative scores (P lt; 0.01). There was no significant difference in JOA score between 2 groups at 3 months after operation (t=1.620 5, P=0.114 6), but the JOA score of microplate group was significantly higher than that of anchor group at 24 months after operation (t=3.454 3, P=0.001 5). X-ray film, MRI, and CT scan at 3-6 months after operation displayed that door spindle reached bony fusion. There was no occurrence of ‘‘re-close of door’’ in 2 groups. The rate of compl ication in microplate group (13.3%, 2/15) was significantly lower than that in anchor group (25.0%, 5/20) (χ2=7.160 0, P=0.008 6). Conclusion ELP by microplate fixation can achieve the stabil ity quickly after operation, which can help patients to do functional exercises early, and has satisfactory effectiveness and less complications.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • Application of ultrasonic bone curette in posterior cervical single open-door laminoplasty

    Objective To investigate the safety and reliability of ultrasonic bone curette in posterior cervical single open-door laminoplasty. Methods The clinical data were retrospectively analyzed, from 193 patients who underwent single open-door laminoplasty (C 3–7) from January 2012 to January 2016. The patients were divided into three groups according to different instruments: posterior single open-door laminoplasty was performed with ultrasonic bone curette in 61 cases (group A), with bite forceps in 73 cases (group B), and with micro-grinding drill in 59 cases (group C). There was no significant difference in gender, age, the course of disease, underlying disease and preoperative Japanese Orthopedic Association (JOA) score, visual analogue scale (VAS) between groups (P>0.05). The operative time, intraoperative blood loss, drainage volume at 48 hours, JOA score, improvement rate, VAS and perioperative com-plication were compared. Results The operative time, intraoperative blood loss, and drainage volume at 48 hours of group A were significantly less than those in groups B and C (P<0.05), but there was no significant between groups B and C (P>0.05). The follow-up time was 12-21 months (mean, 14.6 months) in group A, 24-36 months (mean, 27.5 months) in group B, and 28-47 months (mean, 38.1 months) in group C. There were no cerebrospinal fluid leakage and incision infection in three groups. No complications of internal fixation loosening and rupture occurred during the follow-up. Rediating pain occurred in 6 cases of group A, 8 cases of group B, and 6 cases of group C, and was cured at 1 week after dehydration and physical therapy. No nerve root palsy was found in three groups. Fracture of portal axis occurred in 5 cases (7 segments) of group B and was fixed by micro titanium plate. The JOA score and VAS score at last follow-up were significantly improved when compared with preoperative scores in three groups (P<0.05); there was no significant difference in JOA score and improvement rate and VAS score between groups (P>0.05). Conclusion It is safe and reliable to use the ultrasonic bone curette in posterior cervical single open-door laminoplasty. It can shorten the operative time and has similar clinical curative effect to the traditional operation, and the lateral rotation of the lamina can be avoided.

    Release date:2017-06-15 10:04 Export PDF Favorites Scan
  • CANAL LAMINOPLASTY WITH TITANIUM MINIPLATE REIMPLANTATION OF VERTEBRAL LAMINA

    Objective To evaluate the reliability and the advantageof canal laminoplasty with laminoplasty over laminectomy for treatment of lumbar spinal stenosis.Methods From June 2000 to September 2004, the titanium miniplate fixation technique was applied to re-implantation of the vertebral lamina in the lumbar spine. The vertebral lamina was made with a specially made osteotome and a special technique in 18 patients with lumbar spinal stenosis. Results The patients were followed up for 1 yr and 8 mon on average (range, 3 mon4 yr and 3 mon) and were observed to have a bony fusion of the re-implanted lamina 3-9 months postoperatively. There was no nonunion, displacement of the re-implanted lamina, overgrowth of the anterior bone edge of osteotomy, recompression of the nerves or instability of the lumbar spine. Conclusion The result demonstrates that canal laminoplasty with the titanium miniplate re-implantation of the vertebral lamina in lumbar spine can restore the normal anatomy, keep stability of the spine, and avoid adhesion and scar in the canal.

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • EFFECT OF PENETRATION OF MINI-PLATE LATERAL MASS SCREWS INTO FACET JOINT ON AXIAL SYMPTOMS IN CERVICAL LAMINOPLASTY

    Objective To investigate the effect of the penetration of mini-plate mass screws into facet joint on axial symptoms in cervical laminoplasty. Methods A retrospective analysis was made on the clinical data of 52 patients who underwent unilateral open-door cervical expansive laminoplasty fixed with Centerpiece mini-plate between September 2009 and December 2011. There were 42 males and 10 females, with a mean age of 61.2 years (range, 34-83 years). Seventeen patients exhibited simple degeneration cervical canal stenosis, 25 patients had multilevel cervical disc protrusion, and 10 patients had ossification of posterior longitudinal ligaments. Disease duration ranged 1-120 months (median, 11 months). The Japanese Orthopedic Association (JOA) score was used to assess neurological function, and JOA recovery rates were calculated. The visual analogue score (VAS) and the neck disability index (NDI) were used to evaluate the axial pain and neck daily activities. The axial symptoms and other complications were recorded. The cervical canal diameter, cervical curvature, cervical canal cross area, and open angle were measured according to the X-ray films, CT scans, and MRI scans. The postoperative CT three dimensional (3-D) reconstruction images were used to identify whether the screws penetrated into the facet joints. All the patients were divided into 3 groups according to involved facet joints: no joint penetrating group (no penetrated facet joint), oligo-joint penetrating group (one or two penetrated facet joints), and multi-joint penetrating group (three or more penetrated facet joints). Results Five patients suffered from C5 nerve palsy, and 2 patients had cerebrospinal fluid leakage. The follow-up time ranged 3-35 months (mean, 15.7 months). At the final follow-up, the JOA scores, NDI, cervical canal diameter, and cervical canal cross area were significantly improved when compared with preoperative ones (P lt; 0.05). At 1 week after operation, CT 3-D reconstruction showed that 16 patients had no penetrated facet joint, 23 patients had one or two penetrated facet joints, and 13 patients had three or more penetrated facet joints. There was no significant difference in age, gender, disease duration, operation time, intraoperative blood loss, and follow-up time among 3 groups (P gt; 0.05). And at the final follow-up, there was no significant difference in JOA score, VAS score, cervical curvature, cervical canal diameter, cervical canal cross area, the JOA recovery rates, and lamiae open angle among 3 groups (P gt; 0.05). The NDI of the multi-joint penetrated group was significantly higher than that of other 2 groups (P lt; 0.05). Axial pain occurred in 1 case of no penetrating group, in 4 cases of oligo-joint penetrating group, and in 5 cases of multi-joint penetrating group, showing no significant difference among 3 groups (χ2=4.881, P=0.087). Conclusion The penetrations of lateral mass screws into articular surface of facet joint may contribute to the axial symptoms after cervical laminoplasty. The risk of axial symptom raises accompany with increased penetrated facet joints.

    Release date:2016-08-31 04:05 Export PDF Favorites Scan
  • An Applied Anatomy Research of Digital-CT-based Unilateral Open-door Cervical Expansive Laminoplasty of C7

    ObjectiveTo explore early clinical effects of Centerpiece-based unilateral open-door cervical expansive laminoplasty plus centerpiece titanium minitype plate fixation, to research the data of the best slotting in the CT-based open-door cervical operation and to provide the reference for accurate operation. MethodsA retrospective analysis of the patients who had received Centerpiece-based unilateral open-door cervical expansive laminoplasty plus centerpiece titanium plate fixation from West China Hospital of Sichuan University from February 2013 to November 2013 were performed. The neurological function assessment results (JOA score), cervical curvature indexhave, Pavlov value, spinal canal cross-sectional area and different position, angle and depth of C7 lamina slotting data of all patients before and after the operation were all analyzed and compared. ResultsA total of 58 patients were included. The postoperative JOA score was significantly higher than that of the preoperative (9.4±2.9 vs. 14.7±2.6, t=11.417, P=0.000). The sagittal diameter of vertebral canal (21.3±2.1 mm vs. 9.7±2.1 mm, t=27.737, P=0.000), Pavlov value (0.92±0.13 vs. 0.44±0.12, t=30.621, P=0.000), and spinal canal cross-sectional area (276±37 mm2 vs. 129±25 mm2, t=32.104, P=0.000) at the end of the last follow-up were significantly greater than those of preoperative. When comparing the last follow-up with preoperative, cervical curvature index showed significant difference (11.2±11.5 vs. 9.3±11.7, t=-1.713, P=0.000). Significant differences were found in the comparison of the ideal position and angle of the open door of the C7 lamina and the angle and position of the operation (all P values >0.05); when comparing the position and angle of the ideal position and angle of the C7 lamina hinge with that of the actual operation, no significant differences were found (all P values >0.05); but when comparing the ideal depth with the actual depth of the operation, a significant difference was found (P<0.05). ConclusionCenterpiece micro plate used in posterior cervical expansive open-door laminoplasty forming operation of laminectomy fixed screw loosening and plate breakage, can effectively maintain the lamina in the open state, and prevent it to be closed. The patients have good recovery of nerve function after operation and the clinical efficacy is good.

    Release date: Export PDF Favorites Scan
  • Treatment of benign tumors in thoracic spinal canal by modified replanting posterior ligament complex applying piezoelectric osteotomy

    ObjectiveTo investigate the feasibility and effectiveness of modified replanting posterior ligament complex (PLC) applying piezoelectric osteotomy in the treatment of primary benign tumors in thoracic spinal canal.MethodsThe clinical data of 38 patients with primary benign tumors in thoracic spinal canal between March 2014 and March 2016 were retrospectively analyzed. There were 16 males and 22 females, aged from 21 to 72 years (mean, 47.1 years). The disease duration ranged from 6 to 57 months (mean, 32.6 months). Pathological examination showed 24 cases of schwannoma, 6 cases of meningioma, 4 cases of ependymoma, 2 cases of lipoma, and 2 cases of dermoid cyst. The lesions located in 18 cases of single segment, 15 cases of double segments, and 5 cases of three segments. The length of the tumors ranged from 0.7 to 6.5 cm. There were boundaries between the tumors and the spinal cord, cauda equina, and nerve roots. The preoperative Japanese Orthopaedic Association (JOA) score was 12.2±2.3 and the thoracic Cobb angle was (11.7±2.7)°. Modified PLC replantation and microsurgical resection were performed with piezoelectric osteotomy. Continuity of uniside supraspinal and interspinous ligaments were preserved during the operation. The PLC was exposed laterally. After removing the tumors under the microscope, the pedicled PLC was replanted in situ and fixed with bilateral micro-reconstruction titanium plate. X-ray film, CT, and MRI examinations were performed to observe spinal stability, spinal canal plasty, and tumor resection after operation. The effectiveness was evaluated by JOA score.ResultsThe operation time was 56-142 minutes (mean, 77.1 minutes). The intraoperative blood loss was 110-370 mL (mean, 217.2 mL). The tumors were removed completely and the incisions healed well. Three cases complicated with cerebrospinal fluid leakage, and there was no complications such as spinal cord injury and infection. All the 38 patients were followed up 24-28 months (mean, 27.2 months). There was no internal fixation loosening, malposition, or other related complications. At last follow-up, X-ray films showed no sign of kyphosis and instability. CT showed no displacement of vertebral lamina and reduction of secondary spinal canal volume, and vertebral lamina healed well. MRI showed no recurrence of tumors. At last follow-up, the thoracic Cobb angle was (12.3±4.1)°, showing no significant difference when compared with preoperative value (t=0.753, P=0.456). JOA score increased to 23.7±3.8, showing significant difference when compared with preoperative value (t=15.960, P=0.000). Among them, 14 cases were excellent, 18 were good, 6 were fair, and the excellent and good rate was 84.2%.ConclusionModified replanting PLC applying piezoelectric osteotomy and micro-reconstruction with titanium plate for the primary benign tumors in thoracic spinal canal can reconstruct the anatomy of the spinal canal, enable patients to recover daily activities quickly. It is an effective and safe treatment.

    Release date:2019-07-23 09:50 Export PDF Favorites Scan
  • CLINICAL STUDY ON MODIFIED LAMINOPLASTY WITH POSTERIOR COLUMN RESERVATION FOR TREATMENT OF LUMBAR SPINAL STENOSIS

    Objective To investigate the technique and effectiveness of modified laminoplasty for lumbar spinal stenosis (LSS) and to explore the application value of modified laminoplasty in maintaining the stability of the spine by comparing with the conventional laminectomy. Methods Fifty-six patients with LSS were included between June 2012 and July 2013, and they were divided into 2 groups: 27 patients underwent modified laminoplasty in group A, and 29 patients received conventional laminectomy in group B. There was no significant difference in sex, age, disease duration, narrow segment, visual analogue scale (VAS) score of low back pain and leg pain, Japanese Orthopaedic Association (JOA) score, and walking tolerance between 2 groups (P > 0.05). The postoperative VAS score of low back pain and leg pain, JOA score, walking tolerance, X-ray film, and CT were used to evaluate the clinical results. Results Dural tear occurred in 2 cases of group A and 1 case of group B and were repaired during operation. All incisions primarily healed without infection. The patients were followed up 24-31 months (mean, 24.7 months) in group A, and 24-37 months (mean, 26.2 months) in group B. The bone healing time was 6-12 months (mean, 9 months) in group A. CT showed healing at the junction of spinous process and vertebral plate in group A at 12 months after operation; new scar in varying degre es was observed in group B. At last follow-up, lumbar spondylolisthesis and instability occurred in 4 and 2 cases of group B respectively, and received re-operation. The change value of slip distance was (0.27±0.23) mm in group A and was (0.83±1.22) mm in group B, showing significant difference (t=-2.405, P=0.023). The postoperative JOA score, VAS score, and walking tolerance were significantly improved when compared with preoperative ones in 2 groups (P < 0.05). At last follow-up, group A was better than group B in VAS score of low back pain (P < 0.05), but no significant difference was found in the other indexes between 2 groups (P > 0.05). Conclusion The modified laminoplasty is better than the conventional laminectomy in relieving low back pain and maintaining the stability of the lumbar spine.

    Release date: Export PDF Favorites Scan
  • The application of ultrasonic bone curette in laminoplasty of spinal canal after resection of intraspinal tumors

    Objective To explore the practicability and safety of ultrasonic bone curette in the laminoplasty of spinal canal after resection of intraspinal tumors. Methods The clinical data of 17 patients with thoracolumbar intraspinal tumors treated with ultrasonic bone curette after resection of intraspinal tumors between December 2015 and April 2017 were retrospectively analyzed. All patients were male, aged 42-73 years with an average of 57.4 years. The disease duration was 2-47 months with an average of 21.1 months. Among them, there were 4 cases of thoracic intrathoracic tumors (T10 in 1, T12 in 3) and 13 cases of lumbar intrathoracic tumors (L1 in 5, L2 in 4, L3 in 2, and L4 in 2). Postoperative pathological diagnosis showed that 8 cases were schwannoma, 4 cases were meningioma, 2 cases were neurofibroma, 2 cases were dermoid cyst, and 1 case was ependymoma. Spinal nerve function was evaluated preoperatively according to Frankel classification criteria, with 2 cases of grade B, 7 cases of grade C, and 8 cases of grade D. During the operation, the time of single segmental vertebral canal posterior wall incision, the overall operation time, intraoperative blood loss, intraoperative dural injury, and cerebrospinal fluid leakage, spinal cord and nerve root injury were recorded. At 3-6 months after operation, the tumor and bone healing were observed according to MRI and CT three-dimensional reconstruction, and the spinal nerve function was evaluated by Frankel classification. Results The time of ultrasonic osteotomy for the posterior wall of a single segmental vertebral canal was 3.4-5.7 minutes, with an average of 4.1 minutes. The overall operation time was 135-182 minutes, with an average of 157.3 minutes. The intraoperative blood loss was 300-500 mL, with an average of 342.6 mL. There was no accidental dural injury, and cerebrospinal fluid leakage, nerve root injury, or spinal cord injury. The incision healed by first intention after operation. All the 17 patients were followed up 9-18 months, with an average of 12.7 months. MRI examination showed no tumor recurrence, and CT three-dimensional reconstruction showed good bone healing in all patients. During the follow-up, there was no loosening or rupture of the internal fixator and there was no re-compression of the spinal cord. At last follow-up, according to Frankel classification, there were 1 case as grade B, 5 cases as grade C, 7 cases as grade D, and 4 cases as grade E. Conclusion The application of ultrasonic bone curette in laminoplasty of spinal canal after resection of intraspinal tumors can preserve the integrity of the bone ligament structure of posterior column, maintain the volume of vertebral canal, and has high safety, practicability, and good postoperative effectiveness.

    Release date:2019-01-03 04:07 Export PDF Favorites Scan
  • CLINICAL ANALYSIS OF C5 NERVE ROOT PALSY IN HINGE SIDE AND DIFFERENT ANGLES IN LAMINA OPEN-DOOR AFTER EXPANSION OF OPEN-DOOR CERVICAL LAMINOPLASTY

    Objective To evaluate and compare the relation of the cl inical results of expansion of open-door cervical laminoplasty (EOLP), C5 nerve root palsy in hinge side, and reclose of the opened laminae with different angles in lamina opendoor.Methods Between July 2006 and January 2009, 198 patients with cervical myelopathy were treated by EOLP. Accordingto different opening angles which were measured by CT scan after operation, the patients were divided into group A (gt; 30°, 76 patients including 44 males and 32 females) and group B (15-30°, 122 patients including 71 males and 51 females). There was no significant difference in gender, age, disease duration, and segmental lesions between 2 groups (P gt; 0.05). The Japanese Orthopaedic Association (JOA) score before and after operation was used for neurological assessment and improvement rate, and the postoperative C5 nerve root palsy and reclose of the opened laminae were recorded. Results There was no significant difference in operation time, bleeding volume, and hospital ization days between 2 groups (P gt; 0.05). After 3 weeks of operation, C5 nerve root palsy in the hinge side occurred in 7 patients (9.2%) of group A, and in 2 patients (1.6%) of group B, were restored after symptomatic treatment, showing significant difference between 2 groups (χ2= 4.568, P= 0.033). All patients were followed up 24 to 48 months. Between group A and group B, no significant difference was found in JOA improvement rate at 24 months after operation (P gt; 0.05), and in JOA score at preoperation and at 24 months after operation (P gt; 0.05), but JOA score was significantly improved at 24 months after operation when compared with preoperative score in the same group (P lt; 0.05). The function of l imb l ifting restored in 9 cases of C5 nerve root palsy at 24 months after operation; CT examination revealed that no reclose occured in group A and reclose occurred in 4 cases (3.3%) of group B, but no persistent symptoms or worsen situationwere found during follow-up. Conclusion Different angles in lamina open-door have the same cl inical result; C5 nerve palsy has good prognosis. The opening angle between 15° and 30° will reduce the incidence of C5 nerve root palsy in the hinge side, but the open side should be firmly fixed to prevent further reclose of the opened laminae.

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format