west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "interaction" 26 results
  • Identification of differentially expressed genes in peripheral blood of patients with idiopathic epilepsy by bioinformatics analysis

    ObjectiveTo investigate key differentially expressed genes (DEGs) in peripheral blood of idiopathic epilepsy patients, as well as their biological functions, cellular localization, involved signaling pathways, through bioinformatics analysis. So to provide new insights for the pathogenesis and prevention of idiopathic epilepsy.MethodsFirstly, we screened and downloaded microarray data including 6 peripheral blood samples of drug-naive patients with idiopathic epilepsy, 8 peripheral blood samples of responders of idiopathic epilepsy treated with Valproate (VPA), and 10 peripheral blood samples of non-responders of idiopathic epilepsy treated with VPA from Gene Expression Omnibus (GEO) data series GSE143272, which Public in January 2020. Secondly, we identified DEGs via the limma package and others in R software. Then we had gotten 74 DEGs, and subsequently conducted gene ontology and pathway enrichment analysis, PPI network analysis and hub gene analysis, using multiple methods containing DAVID, STRING, and Cytohubba in Cytoscape.ResultsWe had identified significant hub DEGs, including TREML3P, KCNJ15, ORM1, RNA28S5, ELANE, RETN, ARG1, LCN2, SLPI, HP, PGLYRP1, BPI, DEFA4, TCN1, MPO, MMP9, CTSG, CXCL8, RNASE3, RNASE2, S100A12, DEFA1B, DEFA1, DEFA3, CEACAM8, MS4A3, PTGS2, PI3, CCL3. The biological processes involved in these DEGs include immune response, inflammatory response, chemotaxis, etc. While, the molecular function is focused on peroxidase activity, chemokine activity, etc. Moreover, KEGG pathway enrichment analysis shows that DEGs were mainly involved in cytokine-cytokine receptor interaction, Toll-like receptor signaling pathway, chemokine signaling pathway and so on.ConclusionThese important key DEGs may be involved in the onset and development of idiopathic epilepsy through a variety of signaling pathways and complex mechanisms.

    Release date:2021-01-07 02:57 Export PDF Favorites Scan
  • Generalized interaction LASSO based on alternating direction method of multipliers for liver disease classification

    Features and interaction between features of liver disease is of great significance for the classification of liver disease. Based on least absolute shrinkage and selection operator (LASSO) and interaction LASSO, the generalized interaction LASSO model is proposed in this paper for liver disease classification and compared with other methods. Firstly, the generalized interaction logistic classification model was constructed and the LASSO penalty constraints were added to the interactive model parameters. Then the model parameters were solved by an efficient alternating directions method of multipliers (ADMM) algorithm. The solutions of model parameters were sparse. Finally, the test samples were fed to the model and the classification results were obtained by the largest statistical probability. The experimental results of liver disorder dataset and India liver dataset obtained by the proposed methods showed that the coefficients of interaction features of the model were not zero, indicating that interaction features were contributive to classification. The accuracy of the generalized interaction LASSO method is better than that of the interaction LASSO method, and it is also better than that of traditional pattern recognition methods. The generalized interaction LASSO method can also be popularized to other disease classification areas.

    Release date:2017-06-19 03:24 Export PDF Favorites Scan
  • Testing System Design and Analysis for the Execution Units of Anti-thrombotic Device

    In an anti-thrombotic pressure circulatory device, relays and solenoid valves serve as core execution units. Thus the therapeutic efficacy and patient safety of the device will directly depend on their performance. A new type of testing system for relays and solenoid valves used in the anti-thrombotic device has been developed, which can test action response time and fatigue performance of relay and solenoid valve. PC, data acquisition card and test platform are used in this testing system based on human-computer interaction testing modules. The testing objectives are realized by using the virtual instrument technology, the high-speed data acquisition technology and reasonable software design. The two sets of the system made by relay and solenoid valve are tested. The results proved the universality and reliability of the testing system so that these relays and solenoid valves could be accurately used in the anti-thrombotic pressure circulatory equipment. The newly-developed testing system has a bright future in the aspects of promotion and application prospect.

    Release date:2021-06-24 10:16 Export PDF Favorites Scan
  • Application of electronic skin in healthcare and virtual reality

    Electronic skin has shown great application potential in many fields such as healthcare monitoring and human-machine interaction due to their excellent sensing performance, mechanical properties and biocompatibility. This paper starts from the materials selection and structures design of electronic skin, and summarizes their different applications in the field of healthcare equipment, especially current development status of wearable sensors with different functions, as well as the application of electronic skin in virtual reality. The challenges of electronic skin in the field of wearable devices and healthcare, as well as our corresponding strategies, are discussed to provide a reference for further advancing the research of electronic skin.

    Release date:2023-12-21 03:53 Export PDF Favorites Scan
  • Design of a Testing System for Antithrombotic Pressure Circulatory Equipment

    A new type of testing system used for antithrombotic pressure circulatory equipment has been developed, which realized a new method for the calibration of pressure sensor. Multi-path control and acquisition functions are achieved by this method based on human-computer interaction testing system. The precision of pressure sensor is obtained by polynomial fitting for each test point using linear interpolation method. The result showed that the precision test of pressure sensor could be realized easily and efficiently, using the developed testing system, and the parameters of pressure sensor could be calibrated effectively, so that it could be accurately used in the antithrombotic pressure circulatory equipment. The developed testing system has a prosperous future in the aspects of promotion and application.

    Release date: Export PDF Favorites Scan
  • Research on Three-dimensional Medical Image Reconstruction and Interaction Based on HTML5 and Visualization Toolkit

    Integrating visualization toolkit and the capability of interaction, bidirectional communication and graphics rendering which provided by HTML5, we explored and experimented on the feasibility of remote medical image reconstruction and interaction in pure Web. We prompted server-centric method which did not need to download the big medical data to local connections and avoided considering network transmission pressure and the three-dimensional (3D) rendering capability of client hardware. The method integrated remote medical image reconstruction and interaction into Web seamlessly, which was applicable to lower-end computers and mobile devices. Finally, we tested this method in the Internet and achieved real-time effects. This Web-based 3D reconstruction and interaction method, which crosses over internet terminals and performance limited devices, may be useful for remote medical assistant.

    Release date: Export PDF Favorites Scan
  • Finite element analysis of male lower urinary tract based on the collodion slice images

    Males typically have high rates of morbidity of primary bladder neck obstruction, while the existing urodynamic examination is invasive and more likely to cause false diagnosis. To build a non-invasive biomechanical detecting system for the male lower urinary tract, a finite element model for male lower urinary tract based on the collodion slice images of normal male lower urinary tract was constructed, and the fluid-structure interaction of the lower urinary tract was simulated based on the real urination environment. The finite element model of the lower urinary tract was validated by comparing the clinical experiment data with the simulation result. The stress, flow rate and deformation of the lower urinary tract were analyzed, and the results showed that the Von Mises stress and the wall shear stress at the membrane sphincter in the normal male lower urinary tract model reached a peak, and there was nearly 1 s delay than in the bladder pressure, which helped to validate the model. This paper lays a foundation for further research on the urodynamic response mechanism of the bladder pressure and flow rate of the lower urinary tract obstruction model, which can provide a theoretical basis for the research of non-invasive biomechanical detecting system.

    Release date:2018-08-23 05:06 Export PDF Favorites Scan
  • Construction of an intelligent data integration platform for clinical trials based on information interaction

    In order to promote the openness, transparency and standardization of clinical trials, improve the scientific and reliability of results, and reserve the manpower, material, and financial resources in the process of clinical trials, this study constructed an integrated intelligent management platform for clinical trials, which could carry out various types of clinical trials such as randomized controlled trials, non-randomized controlled trials, cohort studies, case-control studies, and cross-sectional studies simultaneously. The platform covers the whole process of scheme design, recruitment, follow-up, data analysis, and quality control. This paper mainly introduced the practical needs, design concept, basic framework and technical highlights to provide auxiliary tools for promoting the standardization and intelligence of clinical trials with energy saving and optimal efficiency.

    Release date:2022-01-27 05:31 Export PDF Favorites Scan
  • Protein Interaction Network Construction and Biological Pathway Analysis Related to Atherosclerosis

    Atherosclerosis is a complex disease characterized by lipid accumulation in the vascular wall and influenced by multiple genetic and environmental factors. To understand the mechanisms of molecular regulation related to atherosclerosis better, a protein interaction network was constructed in the present study. Genes were collected in nucleotide database and interactions were downloaded from Biomolecular Object Network Database (BOND). The interactional data were imported into the software Cytoscape to construct the interaction network, and then the degree characteristics of the network were analyzed for Hub proteins. Statistical significance pathways and diseases were figured out by inputting Hub proteins to KOBAS2.0. The complete pathway network related to atherosclerosis was constructed. The results identified a series of key genes related to atherosclerosis, which would be the potential promising drug targets for effective prevention.

    Release date: Export PDF Favorites Scan
  • Recent Technical Research Hot Spots and Development Progresses in Medical Whole-body Positron Emission Tomography

    Medical whole-body positron emission tomography (PET), one of the most successful molecular imaging technologies, has been widely used in the fields of cancer diagnosis, cardiovascular disease diagnosis and cranial nerve study. But, on the other hand, the sensitivity, spatial resolution and signal-noise-ratio of the commercial medical whole-body PET systems still have some shortcomings and a great room for improvement. The sensitivity, spatial resolution and signal-noise-ratio of PET system are largely affected by the performances of the scintillators and the photo detectors. The design of a PET system is usually a trade-off in cost and performance. A better image quality can be achieved by optimizing and balancing the key components which affect the system performance the most without dramatically increases in cost. With the development of the scintillator, photo-detector and high speed electronic system, the performance of medical whole-body PET system would be dramatically improved. In this paper, we report current progresses and discuss future directions of the developments of technologies in medical whole-body PET system.

    Release date:2021-06-24 10:16 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content