The purpose of this study is to analyze the biomechanics of ankle cartilage and ligaments during a typical Tai Chi movement–Brush Knee and Twist Step (BKTS). The kinematic and kinetic data were acquired in one experienced male Tai Chi practitioner while performing BKTS and in normal walking. The measured parameters were used as loading and boundary conditions for further finite element analysis. This study showed that the contact stress of the ankle joint during BKTS was generally less than that during walking. However, the maximum tensile force of the anterior talofibular ligament, the calcaneofibular ligament and the posterior talofibular ligament during BKTS was 130 N, 169 N and 89 N, respectively, while it was only 57 N, 119 N and 48 N during walking. Therefore, patients with arthritis of the ankle can properly practice Tai Chi. Practitioners with sprained lateral ligaments of the ankle joint were suggested to properly reduce the ankle movement range during BKTS.
Objective To investigate whether adding 1 transverse screw (TS) to the triangular parallel cannulated screw (TPCS) fixation has a mechanical stability advantage for Pauwels type Ⅲ femoral neck fractures by conducting finite element analysis on four internal fixation methods. Methods Based on CT data of a healthy adult male volunteer’s femur, three Pauwels type Ⅲ femoral neck fracture models (Pauwels angle 70°, Pauwels angle 80°, and Pauwels angle 70° combined with bone defect) were constructed using Mimics 21.0 software and SolidWorks 2017 software. Four different internal fixation models were built at the same time, including TPCS, TPCS+TS, three cross screws (TCS), and TPCS+medial buttress plate (MBP). The mechanical stability of different models under the same load was compared by finite element analysis. Results The femoral model established in this study exhibited a maximum stress of 28.62 MPa, with relatively higher stress concentrated in the femoral neck. These findings were comparable to previous studies, indicating that the constructed femoral finite element model was correct. The maximum stress of internal fixation in finite element analysis showed that TCS was the lowest and TPCS+MBP was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model. The maximum displacement of internal fixation in each fracture model was located at the top of the femoral head, with TCS having the highest maximum displacement of the femur. The maximum stress of fracture surface in finite element analysis showed that TCS was the lowest and TPCS was the highest in the Pauwels angle 70° model, while TPCS+MBP was the lowest and TPCS/TCS were the highest in the Pauwels angle 80° model and the Pauwels angle 70° combined with bone defect model, respectively. The maximum displacement of fracture surfece analysis showed that TPCS+MBP was the lowest and TCS was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model. Conclusion For Pauwels type Ⅲ femoral neck fractures, the biomechanical stability of TPCS+TS was superior to that of TPCS alone and TCS, but it has not yet reached the level of TPCS+MBP.
Due to the superior pigment and high flexural strength, machinable lithium disilicate ceramics can be used as a monolithic crown or veneering porcelains on the zirconia core to form the all-ceramic crowns by sintering or bonding procedures. This paper reports the research on the differences in stress distributions amongst these three types of all-ceramic crowns under typical loading conditions. Three-dimensional numerical models of the restored crown based on the first mandibular molar were developed. The vertical concentrated load and 8-point uniformly distributed load were applied, respectively. The maximum stress and stress distribution were resulted from finite element evaluation. It was found that the maximum tensile stress in 3 types of restored crowns subjected to the concentrate load was less than the flexural strength of IPS e.max. The stress distributions in the sintered and bonded double layered crowns were basically identical, and different from the monolithic crown. The stress magnitude in veneer porcelain of the bonded crown was greater than that in the sintered crown. The use of IPS e.max computer aided design monolithic crown as molar restorations should be careful to avoid high stress as the cyclic stress is a concern of fatigue which may influence the longevity of the restored crown. The bonded double layer crowns bear greater risks of veneer chipping compared with the sintered crowns. The conclusions of this study provide helpful guidelines in clinical applications for preparation of computer aided design/computer aided manufacture lithium disilicate all-ceramic restorations.
ObjectiveTo explore the biomechanical characteristics and clinical application effects of three-dimensional (3D) printed osteotomy guide plate combined with Ilizarov technique in the treatment of rigid clubfoot. Methods A retrospective analysis was performed on the clinical data of 11 patients with rigid clubfoot who met the inclusion criteria and were admitted between January 2019 and December 2024. There were 6 males and 5 females, aged 21-60 years with an average of 43.2 years. Among them, 5 cases were untreated congenital rigid clubfoot, 4 cases were recurrent rigid clubfoot after previous treatment, and 2 cases were rigid clubfoot due to disease sequelae. All 11 patients first received slow distraction using Ilizarov technique combined with circular external fixator until the force lines of the foot and ankle joint were basically normal. Then, 1 male patient aged 24 years was selected, and CT scanning was used to obtain imaging data of the ankle joint and foot. A 3D finite element model was established and validated using the plantar stress distribution nephogram of the patient. After validation, the biomechanical changes of the tibiotalar joint under the same load were simulated after triple arthrodesis and fixation. The optimal correction angle of the hindfoot was determined to fabricate 3D-printed osteotomy guide plates, and all 11 patients underwent triple arthrodesis using these guide plates. The functional recovery was evaluated by comparing the American Orthopaedic Foot and Ankle Society (AOFAS) score, International Clubfoot Study Group (ICFSG) score, and 36-Item Short Form Survey (SF-36) score before and after operation. Results Finite element analysis showed that the maximum peak von Mises stress of the tibiotalar joint was at hindfoot varus 3° and the minimum at valgus 6°; the maximum peak von Mises stress of the 3 naviculocuneiform joints under various conditions appeared at lateral naviculocuneiform joint before operation, and the minimum appeared at lateral naviculocuneiform joint at neutral position 0°; the maximum peak von Mises stress of the 5 tarsometatarsal joints under various conditions appeared at the 2nd tarsometatarsal joint at hindfoot neutral position 0°, and the minimum appeared at the 1st tarsometatarsal joint at valgus 6°. Clinical application results showed that the characteristics of clubfoot deformity observed during operation were consistent with the preoperative 3D reconstruction model. All 11 patients were followed up 8-24 months with an average of 13.1 months. One patient had postoperative incision exudation, which healed after dressing change; the remaining patients had good incision healing. All patients achieved good healing of the osteotomy segments, with a healing time of 3-6 months and an average of 4.1 months. At last follow-up, the AOFAS score, SF-36 score, and ICFSG score significantly improved when compared with those before operation (P<0.05). ConclusionThe 3D-printed osteotomy guide plate combined with Ilizarov technique has favorable biomechanical advantages in the treatment of rigid clubfoot, with significant clinical application effects. It can effectively improve the foot function of patients and achieve precise and personalized treatment.
Objective To investigate the validity of improving the femur’s mechanical characteristics by implanting calcium phosphate ceramic screws after removing dynamic hip screw (DHS). Methods The three dimensional finite element model of the femur was built based on the CT scanning of a normal male volunteer. Then the models of the femur with and without DHS were established. According to calcium phosphate ceramic screws with porosity and apparent elastic modulus, 80% and 0.1 GPa were set as group A, 50% and 1.0 GPa as group B, and 30% and 1.5 GPa as group C. Von Mises stress distribution and maximum stress were recorded when the joint was maximally loaded in a gait cycle. Results The Von Mises in normal femoral shaft was uniform; no phenomena of stress concentration was observed and the maximum stress located at the joint load-bearing site of the proximal femur. The stress concentration was observed in the femur without DHS, and the maximum stress located at the distal femur around the screw hole. By comparing several different calcium phosphate ceramic screws, the stress distribution of group B was similar to normal femur model, and the maximum stress located at the joint load-bearing site. The other screws of groups A and C showed varying degrees of stress concentration. Conclusion Implanting calcium phosphate ceramic screw can improve the mechanical characteristics of the femur after removing dynamic hip screw, and the calcium phosphate ceramic screw with 50% porosity and 1.0 GPa apparent elastic modulus is suitable for implanting.
We observed the effect of vibration parameters on lumbar spine under different vibration conditions using finite element analysis method in our laboratory. In this study, the CT-images of L1-L5 segments were obtained. All images were used to develop 3D geometrical model using the Mimics10.01 (Materialise, Belgium). Then it was modified using Geomagic Studio12.0 (Raindrop Geomagic Inc. USA). Finite element (FE) mesh model was generated by Hypermesh11.0 (Altair Engineering, Inc. USA) and Abaqus. Abaqus was used to calculate the stress distribution of L1-L5 under different vibration conditions. It was found that in a vibration cycle, tensile stress was occurred on lumbar vertebra mainly. Stress distributed evenly and stress concentration occurred on the left rear side of the upper endplate. The stress had no obvious changes under different frequencies, but the stress was higher when amplitude was greater. In conclusion, frequency and amplitude parameters have little effect on the stress distribution in vertebra. The stress magnitude is positively correlated with the amplitude.
Objective To investigate the impact of bone mass and volume of low-density zones beneath the tibial plateau on the maximum von Mises stresses experienced by the cartilage and meniscus in the knee joint. Methods The study included one healthy adult volunteer, from whom CT scans were obtained, and one patient diagnosed with knee osteoarthrisis (KOA), for whom X-ray films were acquired. A static model of the knee joint featuring a low-density zone was established based on a normal knee model. In the finite element analysis, axial loads of 1 000 N and 1 800 N were applied to the weight-bearing region of the upper surface of the femoral head for model validation and subsequent finite element studies, respectively. The maximum von Mises stresses in the femoral cartilage, as well as the medial and lateral tibial cartilage and menisci, were observed, and the stress percentage of the medial and lateral components were concurrently analyzed. Additionally, HE staining, as well as alkaline magenta staining, were performed on the pathological specimens of patients with KOA in various low-density regions. ResultsThe results of model validation indicated that the model was consistent with normal anatomical structures and correlated with previous calculations documented in the literature. Static analysis revealed that the maximum von Mises stress in the medial component of the normal knee was the lowest and increased with the advancement of the hypointensity zone. In contrast, the lateral component exhibited an opposing trend, with the maximum von Mises stress in the lateral component being the highest and decreasing as the hypointensity zone progressed. Additionally, the medial component experienced an increasing proportion of stress within the overall knee joint. HE staining demonstrated that the chondrocyte layer progressively deteriorated and may even disappear as the hypointensity zone expanded. Furthermore, alkaline magenta staining indicated that the severity of microfractures in the trabecular bone increased concurrently with the expansion of the hypointensity zone. Conclusion The presence of subtalar plateau low-density zone may aggravate joint degeneration. In clinical practice, it is necessary to pay attention to the changes in the subtalar plateau low-density zone and actively take effective measures to strengthen the bone status of the subtalar plateau low-density zone and restore the complete biomechanical function of the knee joint, in order to slow down or reverse the progression of osteoarthritis.
Astronauts who are exposed to weightless environment in long-term spaceflight might encounter bone density and mass loss for the mechanical stimulus is smaller than normal value. This study built a three dimensional model of human femur to simulate the remodeling process of human femur during bed rest experiment based on finite element analysis (FEA). The remodeling parameters of this finite element model was validated after comparing experimental and numerical results. Then, the remodeling process of human femur in weightless environment was simulated, and the remodeling function of time was derived. The loading magnitude and loading cycle on human femur during weightless environment were increased to simulate the exercise against bone loss. Simulation results showed that increasing loading magnitude is more effective in diminishing bone loss than increasing loading cycles, which demonstrated that exercise of certain intensity could help resist bone loss during long-term spaceflight. At the end, this study simulated the bone recovery process after spaceflight. It was found that the bone absorption rate is larger than bone formation rate. We advise that astronauts should take exercise during spaceflight to resist bone loss.
Objective To establish the finite element model of Y-shaped patellar fracture fixed with titanium-alloy petal-shaped poly-axial locking plate and to implement the finite element mechanical analysis. Methods The three-dimensional model was created by software Mimics 19.0, Rhino 5.0, and 3-Matic 11.0. The finite element analysis was implemented by ANSYS Workbench 16.0 to calculate the Von-Mises stress and displacement. Before calculated, the upper and lower poles of the patella were constrained. The 2.0, 3.5, and 4.4 MPa compressive stresses were applied to the 1/3 patellofemoral joint surface of the lower, middle, and upper part of the patella respectively, and to simulated the force upon patella when knee flexion of 20, 45, and 90°. Results The number of nodes and elements of the finite element model obtained was 456 839 and 245 449, respectively. The max value of Von-Mises stress of all the three conditions simulated was 151.48 MPa under condition simulating the knee flexion of 90°, which was lower than the yield strength value of the titanium-alloy and patella. The max total displacement value was 0.092 8 mm under condition simulating knee flexion of 45°, which was acceptable according to clinical criterion. The stress concentrated around the non-vertical fracture line and near the area where the screws were sparse. Conclusion The titanium-alloy petal-shaped poly-axial locking plate have enough biomechanical stiffness to fix the Y-shaped patellar fracture, but the result need to be proved in future.
The mechanical properties of nitinol iliac vein stent (NIVS) have been studied by many scholars at home and abroad, but the study on the mechanical properties of iliac vein stent under different release scales has not been reported yet. Based on the finite element analysis method, the mechanical properties of three self-developed NIVS were studied to reveal the influence of stent diameters (12, 14, 16 mm) and different release scales (80%, 90%) on its strength, fatigue life and vein wall biomechanical properties. With an increases in the release scales, the equivalent elastic strain, fatigue strength safety factors, and vessel wall equivalent stress exhibited a downward trend, while the most stressed cross-section coincided with the arc of stent-connecting rods. Through 30, 60 and 90 days’ animal test, a narrowed vascular model was established in the iliac veins of 12 pigs, and the developed iliac vein stents were implanted to comprehensively evaluate the safety and effectiveness of the stent, and at the same time the mechanical properties of stents were verified to provide important reference for the type inspection and clinical trials of follow-up products.