As an emerging non-invasive brain stimulation technique, transcranial direct current stimulation (tDCS) has received increasing attention in the field of stroke disease rehabilitation. However, its efficacy needs to be further studied. The tDCS has three stimulation modes: bipolar-stimulation mode, anode-stimulation mode and cathode-stimulation mode. Nineteen stroke patients were included in this research (10 with left-hemisphere lesion and 9 with right). Resting electroencephalogram (EEG) signals were collected from subjects before and after bipolar-stimulation, anodal-stimulation, cathodal-stimulation, and pseudo-stimulation, with pseudo-stimulation serving as the control group. The changes of multi-scale intrinsic fuzzy entropy (MIFE) of EEG signals before and after stimulation were compared. The results revealed that MIFE was significantly greater in the frontal and central regions after bipolar-stimulation (P < 0.05), in the left central region after anodal-stimulation (P < 0.05), and in the frontal and right central regions after cathodal-stimulation (P < 0.05) in patients with left-hemisphere lesions. MIFE was significantly greater in the frontal, central and parieto-occipital joint regions after bipolar-stimulation (P < 0.05), in the left frontal and right central regions after anodal- stimulation (P < 0.05), and in the central and right occipital regions after cathodal-stimulation (P < 0.05) in patients with right-hemisphere lesions. However, the difference before and after pseudo-stimulation was not statistically significant (P > 0.05). The results of this paper showed that the bipolar stimulation pattern affected the largest range of brain areas, and it might provide a reference for the clinical study of rehabilitation after stroke.
It is very important for epilepsy treatment to distinguish epileptic seizure and non-seizure. In this study, an automatic seizure detection algorithm based on dual density dual tree complex wavelet transform (DD-DT CWT) for intracranial electroencephalogram (iEEG) was proposed. The experimental data were collected from 15 719 competition data set up by the National Institutes of Health (NINDS) in Kaggle. The processed database consisted of 55 023 seizure epochs and 501 990 non-seizure epochs. Each epoch was 1 second long and contained 174 sampling points. Firstly, the signal was resampled. Then, DD-DT CWT was used for EEG signal processing. Four kinds of features include wavelet entropy, variance, energy and mean value were extracted from the signal. Finally, these features were sent to least squares-support vector machine (LS-SVM) for learning and classification. The appropriate decomposition level was selected by comparing the experimental results under different wavelet decomposition levels. The experimental results showed that the features selected in this paper were different between seizure and non-seizure. Among the eight patients, the average accuracy of three-level decomposition classification was 91.98%, the sensitivity was 90.15%, and the specificity was 93.81%. The work of this paper shows that our algorithm has excellent performance in the two classification of EEG signals of epileptic patients, and can detect the seizure period automatically and efficiently.
Focused on the world-wide issue of improving the accuracy of emotion recognition, this paper proposes an electroencephalogram (EEG) signal feature extraction algorithm based on wavelet packet energy entropy and auto-regressive (AR) model. The auto-regressive process can be approached to EEG signal as much as possible, and provide a wealth of spectral information with few parameters. The wavelet packet entropy reflects the spectral energy distribution of the signal in each frequency band. Combination of them gives a better reflect of the energy characteristics of EEG signals. Feature extraction and fusion are implemented based on kernel principal component analysis. Six emotional states from a public multimodal database for emotion analysis using physiological signals (DEAP) are recognized. The results show that the recognition accuracy of the proposed algorithm is more than 90%, and the highest recognition accuracy is 99.33%. It indicates that this algorithm can extract the feature of EEG emotion well, and it is a kind of effective emotion feature extraction algorithm, providing support to emotion recognition.
Finger tapping test is a common testing item for patients with Parkinson's disease (PD) in clinical neurology. It mainly evaluates the fine motor function of patient's hand in three aspects:amplitude, speed and regularity of the movement. This paper focused on the quantitative assessment of regularity of finger tapping movement for PD patients. The movement signals of thumb and index finger were recorded by using inertial sensor unit in the process of tapping test. Two nonlinear dynamic indexes, approximate entropy (ApEn) and sample entropy (SampEn), were calculated, and then the values were statistically analyzed. The experimental results indicated that both indexes had significant differences between patient group and control group. Moreover, the indexes had relatively high correlation with the scores of corresponding unified Parkinson's disease rating scale (UPDRS) item rated by clinical clinician, which illustrated that these two indexes could reflect the injury level of the repetitive finger movement. So, as a reliable method, it can be provided to the clinical evaluation of hand movement function for PD patients.
Heart sound signal is a kind of physiological signal with nonlinear and nonstationary features. In order to improve the accuracy and efficiency of the phonocardiogram (PCG) classification, a new method was proposed by means of support vector machine (SVM) in which the complete ensemble empirical modal decomposition with adaptive noise (CEEMDAN) permutation entropy was as the eigenvector of heart sound signal. Firstly, the PCG was decomposed by CEEMDAN into a number of intrinsic mode functions (IMFs) from high to low frequency. Secondly, the IMFs were sifted according to the correlation coefficient, energy factor and signal-to-noise ratio. Then the instantaneous frequency was extracted by Hilbert transform, and its permutation entropy was constituted into eigenvector. Finally, the accuracy of the method was verified by using a hundred PCG samples selected from the 2016 PhysioNet/CinC Challenge. The results showed that the accuracy rate of the proposed method could reach up to 87%. In comparison with the traditional EMD and EEMD permutation entropy methods, the accuracy rate was increased by 18%–24%, which demonstrates the efficiency of the proposed method.
To explore the relationship between the drug-seeking behavior, motivation of conditioned place preference (CPP) rats and the frontal association cortex (FrA) electroencephalogram (EEG) sample entropy, we in this paper present our studies on the FrA EEG sample entropy of control group rats and CPP group rats, respectively. We invested different behavior in four situations of the rat activities, i.e. rats were staying in black chamber of videoed boxes, those staying in white chamber of videoed boxes, those shuttling between black-white chambers and those shuttling between white-black chambers. The experimental results showed that, compared with the control group rats, the FrA EEG sample entropy of CPP rats staying in black chamber of video box and shuttling between white-black chambers had no significant difference. However, sample entropy is significantly smaller (P < 0.01) when heroin-induced group rats stayed in white chamber of video box and shuttled between black-white chambers. Consequently, the drug-seeking behavior and motivation of CPP rats correlated closely with the EEG sample entropy changes.
Vigilance is defined as the ability to maintain attention for prolonged periods of time. In order to explore the variation of brain vigilance in work process, we designed addition and subtraction experiment with numbers of three digits to induce the vigilance to change, combined it with psychomotor vigilance task (PVT) to measure this process of electroencephalogram (EEG), extracted and analyzed permutation entropy (PE) of 11 cases of subjects' EEG and made a brief comparison with nonlinear parameter sample entropy (SE). The experimental results showed that:PE could well reflect the dynamic changes of EEG when vigilance decreases, and has advantages of fast arithmetic speed, high noise immunity, and low requirements for EEG length. This can be used as a measure of the brain vigilance indicators.
The linear analysis for heart rate variability (HRV), including time domain method, frequency domain method and timefrequency analysis, has reached a lot of consensus. The nonlinear analysis has also been widely applied in biomedical and clinical researches. However, for nonlinear HRV analysis, especially for shortterm nonlinear HRV analysis, controversy still exists, and a unified standard and conclusion has not been formed. This paper reviews and discusses three shortterm nonlinear HRV analysis methods (fractal dimension, entropy and complexity) and their principles, progresses and problems in clinical application in detail, in order to provide a reference for accurate application in clinical medicine.
Synchronization analysis of electroencephalogram (EEG) and electromyogram (EMG) could reveal the functional corticomuscular coupling (FCMC) during the motor task in human. A novel method combining Gabor wavelet and transfer entropy (Gabor-TE) is proposed to quantitatively analyze the nonlinearly synchronous corticomuscular function coupling and direction characteristics under different steady-state force. Firstly, the Gabor wavelet transform method was used to acquire the local frequency-band signals of the EEG and EMG signals recorded from nine healthy controls simultaneously during performing grip task with four different steady-state forces. Secondly, the TE of local frequency-band was calculated and the unit area index of the transfer (ATE) was defined to quantitatively analyze the synchronous corticomuscular function coupling and direction characteristics under steady-state force. Lastly, the effect of EEG and EMG signal power spectrum on Gabor-TE analysis was explored. The results showed that the coupling strength in the beta band was stronger in EEG→EMG direction than in EMG→EEG direction, and the ATE values in the beta band in EEG→EMG direction decreased with the force increasing. It is also shown that the difference in TE values of gamma band present a varying regularity as the increase of force in both directions. In addition, EMG power spectrum was significantly correlated with the result of Gabor-TE inspecific frequency band. The results of our study confirmed that Gabor-TE can quantitatively describe the nonlinearly synchronous corticomuscular function coupling in both local frequency band and information transmission. The analysis of FCMC provides basic information for exploring the motor control and the evaluation of clinical rehabilitation.
The purpose of this study is to compare the differences among neck muscle fatigue evaluation algorithms and to find a more effective algorithm which can provide a human factor quantitative evaluation method for neck muscle fatigue during bending over the desk. We collected surface electromyography signal of sternocleidomastoid muscle of 15 subjects using wireless physiotherapy Bio-Radio when they bent over the desk using memory pillows for 12 minutes. Five algorithms including mean power frequency, spectral moments ratio, discrete wavelet transform, fuzzy approximation entropy and the complexity algorithms were used to calculate the corresponding muscle fatigue index. The least squares method was used to calculate the corresponding coefficient of determination R2 and slope k of the linear regression of the muscle fatigue metric. The coefficient of determination R2 evaluates anti-interference ability of algorithms. The maximum vertical distance Lmax which is obtained by the Kolmogorov-Smirnov test for the slopes k evaluates the ability to distinguish fatigue of algorithms. The results indicate that in the aspect of anti-interference ability, the fuzzy approximation entropy has the largest R2 when using memory pillows with different heights. When the fuzzy approximate entropy is compared with average power frequency or the discrete wavelet transform, the differences are significant (P < 0.05). In terms of distinguishing the degree of fatigue, the approximate entropy is still the largest, with a maximum of 0.496 7. Fuzzy approximation entropy is superior to other algorithms in ability of anti-interference and distinguishing fatigue. Therefore, fuzzy approximation entropy can be used as a better evaluation algorithm in the evaluation of cervical muscle fatigue.