west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "cannulated screw" 16 results
  • Application of three-dimensional printing technology for closed reduction and percutaneous cannulated screws fixation of displaced intraarticular calcaneus fractures

    Objective To evaluate the effectiveness of three-dimensional (3-D) printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation. Methods A retrospective analysis was performed of the 19 patients (19 feet) with intraarticular calcaneal fracture who had been treated between March 2015 and May 2016. There were 13 males and 6 females with an average age of 38.2 years (range, 24-73 years). There were 3 open fractures and 16 closed fractures. By Sanders classification, 12 cases were type Ⅱ, 7 cases were type Ⅲ. By Essex-Lopresti classification, 13 cases were tongue type, 6 cases were joint-depression type. The time from injury to surgery was 1-10 days (mean, 4.7 days). A thin slice CT scan was taken of bilateral calcaneus in patients. By using the mirror imaging technique, the contralateral mirror image and the affected side calcaneus model were printed according to 1∶1 ratio. The displacement of fracture block was observed and contrasted, and the poking reduction was simulated. Calcaneal fracture was treated by percutaneous minimally invasive poking reduction and cannulate screw fixation. The Böhler angle and Gissane angle at immediate after operation and last follow-up was measured on X-ray films, and compared with preoperative measurement. The functional recovery was evaluated by American Orthopaedic Foot and Ankle Society (AOFAS) scores. Results The operation time was 25-70 minutes (mean, 45 minutes). The intraoperative blood loss was 10-40 mL (mean, 14.5 mL). All the incisions healed by first intention and had no relevant postoperative complications such as skin necrosis, nail tract infection, and osteomyelitis. All the patients were followed up 12-25 months (mean, 14.6 months). All patients obtained fracture healing, and the fracture healing time was 8-14 weeks (mean, 10.3 weeks). No screw withdrawal or breakage occurred during follow-up; only 1 patient with Sanders type Ⅱ fracture, whose calcaneus height was partially lost at 6 weeks after operation, the other patients had no reduction loss and fracture displacement, and no traumatic arthritis occurred. The Böhler angle and Gissane angle at immediate after operation and last follow-up were significantly improved when compared with preoperative ones (P<0.05), but there was no significant difference between at immediate after operation and last follow-up (P>0.05). The AOFAS score was 76-100 (mean, 88.2), and the results were excellent in 10 feet, good in 7, and fair in 2, the excellent and good rate was 89.5%. Conclusion 3-D printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation can reduce the surgical trauma, improve the quality of reduction and fixation, and make the operation more safe, accurate, and individualized.

    Release date:2017-11-09 10:16 Export PDF Favorites Scan
  • Risk of micro-fracture in femoral head after removal of cannulated screws for femoral neck fracture

    ObjectiveTo explore the changes of bone and risk of micro-fracture in femoral head after removal of cannulated screws following femoral neck fracture healing under the impact force of daily stress.MethodsA total of 42 specimens of normal hip joint were collected from 21 adult fresh cadaveric pelvic specimens. Wiberg central-edge (CE) angle, bone mineral density, diameter of femoral head, neck-shaft angle, and anteversion angle of femoral neck were measured. Then, the 3 cannulated screws were implanted according to the AO recommended method and removed to simulate the complete anatomical union of femoral neck fracture. The morphology of screw canal in the femoral head was observed by CT. Finally, the specimens were immobilized vertically within the impact device in an upside-down manner, and the femoral heads were impacted vertically. Every specimen was impacted at 200, 600, and 1 980 N for 20 times with the impacting device. After impact, every specimen was scanned by CT to observe the morphology changes of screw canal in the femoral head. Micro-fractures in the femoral head could be confirmed when there was change in the morphology of screw canal, and statistical software was used to analyze the risk factors associated with micro-fractures.ResultsAfter impact at 200 and 600 N, CT showed that the morphology of screw canal of all specimens did not change significantly compared with the original. After impact at 1 980 N, there were protrusion and narrowing in the screw canal of the 22 femoral head specimens (11 pelvic specimens), showing obvious changes compared with the original screw canal, indicating that there were micro-fractures in the femoral head. The incidence of micro-fracture was 52.38% (11/21). logistic regression results showed that there was correlation between micro-fracture and bone mineral density (P= 0.039), but no correlation was found with CE angle, diameter of femoral head, neck-shaft angle, and anteversion angle (P>0.05).ConclusionThe micro-fractures in the femoral head may occur when the femoral head is impacted by daily activities after removal of cannulated screws for femoral neck fractures, and such micro-fractures are associated with decreased bone density of the femoral head.

    Release date:2020-09-28 02:45 Export PDF Favorites Scan
  • Treatment of Day type Ⅱ pelvic crescent fracture by using percutaneous cannulated screw fixation technique

    ObjectiveTo evaluate the feasibility and effectiveness of percutaneous cannulated screw fixation for the treatment of Day type Ⅱ pelvic crescent fracture.MethodsThe clinical data of 14 patients with Day type Ⅱ pelvic crescent fractures underwent closed reduction and percutaneous cannulated screw fixation between January 2009 and July 2016 were retrospectively analysed. There were 9 males and 5 females, aged 17-65 years (mean, 38 years). The causes of injury included traffic accident in 8 cases, falling from height in 3 cases, bruise injury in 3 cases; all were closed fractures. According to Tile classification, there were 8 cases of type B, 6 cases of type C. There were 13 cases combined with fracture of the anterior pelvic ring, including 8 cases of superior and inferior ramus of pubis fracture, 1 case of superior ramus of pubis fracture with symphysis separation, and 4 cases of symphysis separation. The interval of injury and admission was 1- 72 hours (mean, 16 hours), and the interval of injury and operation was 3-8 days (mean, 5 days). After operation, the reduction of fracture was evaluated by the Matta evaluation criteria, the clinical function was assessed by Majeed function assessment.ResultsThe operation time was 35-95 minutes (mean, 55 minutes), cumulative C-arm fluoroscopy time was 3-8 minutes (mean, 5 minutes), no iatrogenic vascular injury and pelvic organ damage occurred. Postoperative X-ray films at 2 days indicated that 2 cases of vertical shift and 2 cases of mild rotation were not completely corrected. Postoperative CT examination at 3 days indicated that 2 pubic joint screws broke through the obturator bone cortex. None of the pubic ramus screws entered into the acetabulum, but a screw of superior pubic branch broke through the posterior cortical of superior pubic branch, a screw of posterior ilium column broke through the medial bone cortex of the ilium, and no clinical symptom was observed. One patient suffered from wound infection in the pubic symphysis, then healed after 2 weeks of wound drainage, the other wounds healed by first intention. According to Matta criterion for fracture reduction, the results were excellent in 9 cases, good in 4 cases, and fair in 1 case with an excellent and good rate of 92.9%. All patients were followed up 8-24 months (mean, 14 months). All fractures healed at 4 months and restored to the normal walking at 6 months after operation, 3 patients suffered from slight pain in the sacroiliac joints and slight claudication when they were tired or walked for a long time and unnecessary for special treatment. One patient felt pain in the back of the iliac spine when he was lying down. During the follow-up, no screw loosening or other internal fixation failure occurred. At last follow-up, according to Majeed functional evaluation criteria, the results were excellent in 7 cases, good in 5 cases, and fair in 2 cases with an excellent and good rate of 85.7%.ConclusionThe percutaneous cannulated screw fixation is a safe treatment for Day type Ⅱ pelvic crescent fracture, which has a reliable fixation and good effectiveness.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • Dynamic hip screw combined with anti-rotation screw versus cannulated screw alone for femoral neck fracture in adults: a meta-analysis

    Objective To compare the efficacy and safety of dynamic hip screw (DHS) + anti-rotation screw and cannulated screw alone for femoral neck fracture in adults. Methods PubMed, Web of Science, Cochrane Library, China National Knowledge Infrastructure, SinoMed, Wanfang, and Chongqing VIP database were searched for the literature related to the comparison between DHS + anti-rotation screw and cannulated screw alone for femoral neck fracture in adults from the establishment of databases to 2022. RevMan 5.3 software was used for meta-analysis. Results Finally, 25 clinical studies were included, including 8 randomized controlled trials and 17 observational studies, 5 in English and 20 in Chinese. There were a total of 2099 patients, including 989 in the DHS + anti-rotation screw group and 1110 in the cannulated screw group. The meta-analysis results showed that the incidence of bone nonunion [odds ratio (OR)=0.29, 95% confidence interval (CI) (0.17, 0.48)], incidence of femoral head necrosis [OR=0.48, 95% CI (0.27, 0.88)], failure rate of internal fixation [OR=0.28, 95% CI (0.15, 0.51)] in the DHS + anti-rotation screw group were lower than those in the cannulated screw group (P<0.05). The surgical duration [mean difference (MD)=9.91, 95% CI (6.78, 13.05)], incision length [MD=1.25, 95% CI (0.15, 2.35)], and Harris score [MD=6.77, 95% CI (4.66, 8.88)] in the DHS + anti-rotation screw group were higher than those in the cannulated screw group (P<0.05). There was no statistically significant difference in intraoperative bleeding volume, Visual Analogue Scale score, hospital stay, and fracture healing time between the two groups (P>0.05). The incidence of bone nonunion in the DHS + anti-rotation screw group after Pauwels type Ⅲ fracture [OR=0.16, 95% CI (0.05, 0.50)] was lower than that in the cannulated screw group (P<0.05), and there was no statistically significant difference in the incidence of femoral head necrosis between the two groups (P>0.05). Conclusions For femoral neck fracture in adults, DHS + anti-rotation screw can reduce the incidence of bone nonunion, femoral head necrosis, and internal fixation failure compared with cannulated screw alone, and has a higher Harris score, but the surgical duration and incision are longer. Overall, DHS + anti-rotation screw are better at reducing the incidence of complications than cannulated screws alone.

    Release date:2023-04-24 08:49 Export PDF Favorites Scan
  • Efficacy of Percutaneous Cannulated Screw versus Plate Fixation for Ankle Fractures: A Meta-analysis

    ObjectiveTo systematically review the efficacy of percutaneous cannulated screw (PCS) versus plate fixation (PF) in the treatment of ankle fractures. MethodsThe Cochrane Library (Issue 5, 2014), PubMed, EMbase, CBM, CNKI, VIP and WanFang Data were searched up to May 28th 2014, for studies concerning the efficacy of percutaneous cannulated screw versus plate fixation for ankle fractures. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and assessed the methodological quality of included studies. Then, meta-analysis was performed by using RevMan 5.1 software. Result A total of 10 studies (3 RCTs and 7 CCTs) involving 627 patients were included. The results of meta-analysis showed that:compared with the PF group, the PCS group was superior in time of the operation (RCT:MD=-6.78, 95%CI -11.95 to -1.60, P=0.01; CCT:MD=-9.76, 95%CI -13.68 to -5.84, P<0.000 01), blood loss during the operation (RCT:MD=-36.14, 95%CI -40.02 to -32.17, P<0.000 01; CCT:MD=-34.80, 95%CI -37.78 to -31.81, P<0.000 01) and the time of the fracture healing (RCT:MD=-1.16, 95%CI -1.51 to -0.81, P<0.000 01; CCT:MD=-1.55, 95%CI -2.97 to -0.13, P=0.03); However, there were no statistical differences between the two groups in complication rate (CCT:OR=0.48, 95%CI 0.08 to 2.81, P=0.41), AOFAS score excellent rate (RCT:OR=2.11, 95%CI 0.81 to 5.49, P=0.12; CCT:OR=1.58, 95%CI 0.75 to 3.30, P=0.23), and postoperative malleolus pain rate (CCT:OR=0.68, 95%CI 0.00 to 148.82, P=0.89). ConclusionCurrent evidence shows that PCS is superior to PF in shorting time of the operation, reducing blood loss during the operation, and shorting time of the fracture healing. However, the complication rate, AOFAS score excellent rate, and postoperative malleolus pain rate are similar for each operation. Due to the quality limitation of the CCTs, the conclusion are needed to be verified by more high quality RCTs in future.

    Release date: Export PDF Favorites Scan
  • Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures

    Objective To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures. Methods A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups (P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex. Results No significant difference was observed in operation time between the two groups (P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex (P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups (P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group (P<0.05). ConclusionCompared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.

    Release date:2025-06-11 03:21 Export PDF Favorites Scan
  • Arthroscopic treatment of anterior cruciate ligament tibial eminence avulsion fracture with double heads compressive cannulated screw fixation in adolescents

    ObjectiveTo discuss the effectiveness of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture in adolescents by using double heads compressive cannulated screw fixation.MethodsTwenty-four patients with ACL tibial eminence avulsion fractures were treated by arthroscopic reduction and internal fixation with double heads compressive cannulated screw fixation between June 2014 and June 2017. There were 15 males and 9 females with an average age of 12.3 years (range, 5-18 years). The body mass index was 19.3-26.4 kg/m2 (mean, 23.3 kg/m2). The injury causes included traffic accident injury in 10 cases, sports injury in 8 cases, and falling injury in 6 cases. According to the Meyers-McKeever classification, there were 19 cases of type Ⅱ and 5 cases of type Ⅲa. All patients’ drawer test and pivot shift test were positive. The interval between injury and operation was 3-14 days (mean, 6.2 days). During the follow-up period, the fracture healing condition of patients were determined by X-ray examination; Lysholm score, International Knee literature Committee (IKDC) score, and Tegner score were used to evaluate the knee function.ResultsPrimary healing of incision was obtained in all patients after operation. All the 24 patients were followed up 6-32 months (mean, 16.4 months). At 6 weeks after operation, 3 patients had difficulty in knee flexion. After the release of the knee joint by manipulation, the knee joint function recovered normally at 6 months after operation. At last follow-up, the X-ray films showed that all the fractures healed and no epiphyseal dysplasia, knee joint deformity, or leg length discrepancy occurred. The Lysholm score, IKDC score, and Tegner score were improved from preoperative 44.3±5.4, 43.7±4.4, and 3.0±1.3 to postoperative 93.1±4.3, 94.6±3.3, and 8.1±1.2, the differences were all significant (t=25.152, P=0.000; t=28.634, P=0.000; t=13.226, P=0.000).ConclusionThe arthroscopic reduction and internal fixation with double heads compressive cannulated screw in treatment of ACL tibial avulsion fracture (Meyers-McKeever type Ⅱ and Ⅲ) in adolescents has so many advantages, such as minimal trauma, simple operation, firm fixation, little effect on the epiphyseal plate, and has a good joint function recovery.

    Release date:2018-09-03 10:13 Export PDF Favorites Scan
  • Comparison of full thread compression cannulated screw and partial thread cannulated screw in treatment of femoral neck fracture

    Objective To compare the effectiveness of full thread compression cannulated screw and partial thread cannulated screw in the treatment of femoral neck fracture. Methods A retrospective analysis was made on 152 patients with femoral neck fractures, who met the selection criteria, between April 2013 and February 2021. The fractures were fixed with the full thread compression cannulated screws in 74 cases (trial group) and the partial thread cannulated screws in 78 cases (control group). There was no significant difference in general data such as age, gender, body mass index, cause of injury, time from injury to operation, and the side, Garden typing, Pauwels typing of fracture between the two groups (P>0.05). The operation time, intraoperative blood loss, hospital stay, follow-up time, and Harris score were recorded in both groups. X-ray films were performed to evaluate the quality of fracture reduction and bone healing, the changes of neck-shaft angle, the changes of femoral neck, as well as the occurrence of internal fixation failure, screw back-out, and osteonecrosis of the femoral head. Results There was no significant difference in operation time and hospital stay between the two groups (P>0.05). However, the intraoperative blood loss in the trial group was significantly lower than that in the control group (P<0.05). Patients in both groups were followed up, with the follow-up time of (24.11±4.04) months in the trial group and (24.10±4.42) months in the control group, and the difference was not significant (P>0.05). Postoperative X-ray films showed that there was no significant difference in fracture reduction grading between the two groups (P>0.05). Six cases in the trial group developed bone nonunion and 7 cases in the control group, the fractures of the other patients healed, and the healing time was significantly shorter in the trial group than in the control group (P<0.05). There was no significant difference in the incidence of bone nonunion between the two groups (P>0.05). During follow-up, 2 cases in the trial group and 5 cases in the control group had osteonecrosis of the femoral head, the difference was not significant (P>0.05), and the patients with osteonecrosis of the femoral head were treated with secondary operation. The screw back-out occurred in 3 cases of the trial group and in 9 cases of the control group, showing no significant difference (P>0.05). But the screw back-out distance was significantly shorter in the trial group than in the control group (P<0.05). The incidence of internal fixation failure in the trial group (4 cases) was significantly lower than that in the control group (14 cases) (P<0.05). The incidence of femoral neck shortening and the change of neck-shaft angle at 1 year after operation were significantly lower in the trial group than in the control group (P<0.05). The Harris score at last follow-up was significantly higher in the trial group than in the control group (P<0.05). Conclusion Compared with the partial threaded cannulated screws, the full threaded cannulated compression screws can effectively maintain fracture reduction, avoid femoral neck shortening, and internal fixation failure. It is a better choice for femoral neck fracture.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
  • CLINICAL RESEARCH OF INDIVIDUAL PERCUTANEOUS CANNULATED SCREWS FIXATION FOR TREATMENT OF Herbert TYPE Ib SCAPHOID FRACTURE

    ObjectiveTo investigate the effectiveness of individual percutaneous cannulated screws fixation of computer-assisted design combined with three-dimensional (3D) guide plate by comparing with cast immobilization and open internal fixation for treatment of Herbert type Ib scaphoid fracture. MethodsBetween January 2010 and June 2015, 56 patients with fresh Herbert type Ib scaphoid fracture were treated with cast immobilization in 16 cases (external fixation group), with open reduction and internal fixation in 20 cases (open reduction group), and with individual percutaneous cannulated screws fixation of computer-assisted design combined 3D guide plate in 20 cases (minimal invasion group). There was no significant difference in gender, age, injury cause, side, disease duration, and classification of fractures between groups P>0.05).The time of bone union, bone nonunion rate, return-to-work time, wrist range of motion (ROM), and Mayo function score were recorded and compared. ResultsPrimary healing of incision was obtained in open reduction group and minimally invasion group, without related complications. The cases were followed up 10-24 months (mean, 16.6 months). The time of bone union and return-to-work time of minimal invasion group were significantly shorter than those of the other 2 groups (P<0.05), and the rate of bone nonunion was significantly lower than that of the other 2 groups (P<0.05). At last follow-up, the wrist ROM of minimal invasion group[(104.40±3.46)°] was significantly larger than that of external group[(94.20±2.42)°] and open reduction group[(96.40±2.66)°] (P<0.05). According to Mayo function score, the results were excellent in 6 cases, good in 5 cases, fair in 2 cases, and poor in 3 cases in external fixation group, with an excellent and good rate of 69%; the results were excellent in 9 cases, good in 7 cases, fair in 2 cases, and poor in 2 cases in open reduction group, with an excellent and good rate of 80%; the results were excellent in 16 cases, good in 3 cases, and fair in1 case in minimal invasion group, with an excellent and good rate of 95%; there was significant difference in excellent and good rate among groups (P<0.05). ConclusionIndividual percutaneous cannulated screws fixation of computer-assisted design combined with 3D guide plate has satisfactory effectiveness in the treatment of Herbert type Ib scaphoid fractures, with the advantages of mini-invasion, high accuracy, high rate of bone union, less complication, early return-to-work time.

    Release date:2016-10-21 06:36 Export PDF Favorites Scan
  • Effectiveness of minimally invasive plate and medial supporting cannulated screw fixation via tarsal sinus approach for Sanders type Ⅱ and Ⅲ calcaneal fractures

    ObjectiveTo investigate the effectiveness of minimally invasive plate and medial supporting cannulated screw fixation via tarsal sinus approach in treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures. Methods A clinical data of 46 patients with Sanders type Ⅱand Ⅲ calcaneal fractures met the selective criteria between March 2016 and March 2021 was retrospectively analyzed. The factures were fixed with minimally invasive plate and medial supporting cannulated screws via tarsal sinus approach in 20 cases (group A) and with minimally invasive plate in 26 cases (group B). There was no significant difference between groups in term of the gender, age, injury causes, fracture type and side, the time from injury to operation, and preoperative calcaneal length and width, Böhler angle, Gissane angle, and visual analogue scale (VAS) score (P>0.05). The operation time, intraoperative blood loss, hospital stay, and the interval between operation and full weight-bearing were recorded. The pain improvement of patients was evaluated by VAS scores before operation and at 48 hours after operation. The ankle joint function was evaluated by American Orthopaedic Foot and Ankle Society (AOFAS) score at 3 and 12 months after operation. Besides, the calcaneal length and width, Böhler angle, and Gissane angle were measured by X-ray films before and after operation. Furthermore, the difference (loss value) between 3, 12 months and 1 day after operation was calculated. Moreover, the fracture healing and healing time was observed. ResultsAll operations of two groups were successfully completed. The incisions healed by first intention, and no vascular/nerve injury or incision infection occurred. The operation time of group A was significantly longer than that of group B (P<0.05). There was no significant difference in the intraoperative blood loss, hospital stay, and the interval between operation and full weight-bearing (P>0.05). All patients were followed up 12-36 months (mean, 14.8 months). The VAS scores at 48 hours after operation were significantly lower than those before operation in the two groups (P<0.05); there was no significant difference in the difference of pre- and post-operative VAS score between groups (P>0.05). The AOFAS scores at 12 months after operation were significantly higher than those at 3 months after operation in the two groups (P<0.05); and there was no significant difference between groups at 3 and 12 months (P>0.05). X-ray films showed that the fractures of the two groups healed and there was no significant difference in healing time (P>0.05). There was no significant difference in calcaneal length and width and Gissane angle between groups at each time point (P>0.05), but there was significant difference in Böhler angle between groups at 12 months (P<0.05). The imaging indexes of the two groups significantly improved at each time point after operation when compared with those before operation (P<0.05). There was no significant difference between different time points after operation (P>0.05) in the imaging indexes of group A. There were significant differences in the calcaneal length, calcaneal width, and Gissane angle of group B between 12 months and 1 day, 3 months after operation (P<0.05), and there was no significant difference between 1 day and 3 months after operation (P>0.05). The differences in Böhler angle of group B between different time points after operation were significant (P<0.05). There was no significant difference between groups in the loss of all imaging indexes at 3 months after operation (P>0.05). The losses of calcaneal width, Böhler angle, and Gissane angle in group A at 12 months after operation were significantly smaller than those in group B (P<0.05), and there was no significant difference in the loss of calcaneus length between groups (P>0.05). ConclusionCompared with only minimally invasive plate fixation, the combination of minimally invasive plate and medial supporting cannulated screw fixation via tarsal sinus approach for Sanders type Ⅱ and Ⅲ calcaneal fractures has the advantages of less trauma, less incision complications, reliable fracture reduction and fixation, and good long-term stability.

    Release date:2023-01-10 08:44 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content