west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "aortic stenosis" 39 results
  • Surgical Results of Secondary Subaortic Stenosis after Congenital Heart Disease Operations

    Abstract: Objective To summarize surgical results of secondary subaortic stenosis (SSS) after congenital heart disease (CHD) operations,and analyze the pathogenesis of SSS. Methods We retrospectively analyzed clinical data of 19 patients who underwent surgical repair for SSS in Guangdong General Hospital from 1st June 2008 to 31st December 2012. There were 10 males and 9 females. CHD types included double outlet right ventricle,ventricular septal defect and partial atrioventricular septal defect,et al. The median age of the patients when they received their first CHD operations was 4 months (15 days to 5 year and 11 months). The median age of the patients when they received SSS repair was 5 years and 3 months (1 year to 15 years and 3 months). The median time interval from CHD operation to SSS repair was 4 years and 10 months (8 months to 13 years and 11 months). Results All the patients successfully received their SSS repair. There was no surgical death in this study. Median cardiopulmonary bypass time was 79 (39 to 172) minutes,and median aortic cross-clamp time was 42 (22 to 124) minutes. Median postoperative hospital stay was 7 (5 to 9) days. Postoperatively, 1 patient required permanent pacemaker implantation. All the patients were followed up after discharge for a median durationof 1 year and 10 months (5 months to 4 years and 4 months) . During follow-up, none of the patients had any clinical symptom,their heart function was normal,and there was no late death. One patient received another subaortic stenosis repair for gradually aggravating left ventricular outflow tract stenosis. Conclusions SSS is very rare after CHD operations. The pathogenesis of SSS is perhaps related to abnormal blood flows in the left ventricular outflow tract after CHD operations. The pathogenesis time of SSS and types of CHD leading to SSS cannot be predicted. Subaortic stenosis repair is a simple and safe procedure for SSS,but postoperatively left ventricular outflow tract stenosis may appear and aggravate again.

    Release date:2016-08-30 05:47 Export PDF Favorites Scan
  • Treatment and effect of cardiovascular surgery in patients with Williams syndrome

    ObjectiveTo analyze the effects of cardiovascular surgery on Williams syndrome (WS).MethodsThe clinical data of 68 WS patients undergoing cardiovascular surgery in the Department of Cardiac Surgery, Guangdong Provincial People's Hospital from January 2010 to January 2020 were retrospectively analyzed. There were 48 males and 20 females with a median age of 2.8 years ranging from 3 months to 33 years. Except one patient undergoing the coarctation repair, the rest 67 patients underwent surgical interventions to correct supravalvular aortic stenosis (SAVS) and pulmonary artery stenosis with hypothermic cardiopulmonary bypass, concommitant with 3 patients of relief of left ventricular outflow tract obstruction, 2 patients of relief of right ventricular outflow tract obstruction, 2 patients of mitral valvuloplasty, 3 patients of ventricular septal defect repair and 1 patient of arterial catheter ligation.ResultsTwo (2.9%) patients died of sudden cardiac arrest on the next day after surgery. One (1.5%) patient died of cardiac insufficiency due to severe aortic arch stenosis 3 years after surgery. The effect of SAVS was satisfactory. Two (2.9%) patients progressed to moderate aortic valvular regurgitation during postoperative follow-up. A total of 5 (7.4%) patients were re-intervened after operation for arch stenosis or pulmonary stenosis.ConclusionWS patients should be diagnosed early, followed up and assessed for cardiovascular system diseases, and timely surgical treatment has a good clinical effect.

    Release date:2021-07-28 10:02 Export PDF Favorites Scan
  • Safety and effectiveness of the SAPIEN 3 transcatheter heart valve in the treatment of severe aortic stenosis: Early clinical outcomes of a multicenter study in China

    Objective To evaluate the safety and efficacy of transcatheter aortic valve replacement (TAVR) using the SAPIEN 3 system. MethodsThis was a prospective, multicenter, single arm study in 4 centers in China. The clinical data of 50 patients with high-risk symptomatic severe aortic stenosis who underwent TAVR using the SAPIEN 3 system from June 2017 to June 2019 were analyzed, including 27 males and 23 females aged 76.8±6.1 years. ResultsThe Society of Thoracic Surgeon score was 6.0%±2.8%. Totally, 20.0% of patients had severe bicuspid aortic stenosis. The operation time was 41.8±16.5 min and the hospital stay time was 8.5±5.0 d. At the postoperative 30-day follow-up, no all-cause mortality occurred and the device success rate was 89.5%. Major vascular complications occurred in one (2.0%) patient, stroke in one (2.0%) patient, new pacemaker implantation in one (2.0%) patient, as well as coronary artery obstruction in one (2.0%) patient. There was no moderate or moderate/severe paravalvular leak. The aortic pressure gradient was decreased from 49.2±16.2 mm Hg before the operation to 12.4±4.6 mm Hg at the postoperative 30-day follow-up, and the valvular area was increased from 0.6±0.3 cm2 to 1.3±0.3 cm2 (P<0.01). Moreover, the New York Heart Association classification in 83.7% of the patients was improved during the follow-up. ConclusionThis pre-marketing multicenter study has demonstrated the safety and effectiveness of transfemoral TAVR with the SAPIEN 3 transcatheter valve system in Chinese aortic stenosis patients at high risk for surgery.

    Release date:2022-05-23 10:52 Export PDF Favorites Scan
  • Outcomes of surgical treatment for congenital aortic stenosis in 145 children: A retrospective cohort study

    ObjectiveTo explore the experience of surgical repair for congenital aortic stenosis (AS) in our center.MethodsWe retrospectively reviewed the clinical data of 145 children diagnosed with AS, who underwent aortic repair from 2008 to 2019, with or without aortic insufficiency (AI), including 104 males and 41 females with a median age of 2.9 (0.6, 7.8) years. The preoperative and intraoperative data, early and long-term valvular function, long-term survival rate and freedom from reoperation and aortic valve replacment (AVR) were analyzed.ResultsThere were 120 patients receiving commissurotomy, 15 valvuloplasty with extra pericardium patch, and 25 AVR. The mean follow-up time was 0.25-11.20 (4.2±2.8) years. Survival rate at 10 years was 92.3%. Freedom from reoperation and AVR was 63.2% and 60.4% respectively. Multivariate analysis revealed that using a patch during surgery (P=0.036) was an independent risk factor for reoperation. A history of preoperative balloon dilation (P=0.029) and significant preoperative AI (P=0.001) contributed to AVR.ConclusionSurgical treatment of congenital aortic valve stenosis in children is a safe and effective method that provides enough time to achieve a more definitive solution. Using a patch during surgery increases reoperation hazard. A history of previous balloon dilation and significant preoperative AI may result in AVR during the follow-up.

    Release date:2021-07-02 05:22 Export PDF Favorites Scan
  • Midterm outcome of percutaneous balloon aortic valvuloplasty guided by single echocardiography for congenital aortic stenosis

    Objective To analyze the midterm outcome of patients with congenital aortic stenosis undergoing percutaneous balloon aortic valvuloplasty (PBAV) by single echocardiographic guidance. Methods The clinical data of 12 patients with congenital aortic stenosis who underwent PBAV by single echocardiographic guidance at Fuwai Hospital from January 2016 to November 2017 were retrospectively analyzed. There were 7 males and 5 females with an average age of 18.27±15.30 years. The preoperative peak pressure gradient was 61.8–110.0 (80.30±24.50) mm Hg, and 50% of patients had aortic regurgitation. Results All patients successfully underwent PBAV. Aortic annulus diameter was 18.65±3.17 mm and balloon diameter was 17.62±3.77 mm, with balloon diameter to annulus diameter ratio of 0.92±0.07. The peak transaortic gradient was 16-51 (36.72±12.33) mm Hg immediately after procedure, which was significantly different from the preoperation (P=0.000). During the follow-up period, the peak transaortic gradient was 21-58 (37.06±13.52) mm Hg, and there was no significant difference between the follow-up and immediate postoperation (P=0.310). Immediately after procedure and during follow-up, 58% of patients had aortic regurgitation, which was not statistically different from the preoperation (P=0.682). Conclusion Systematic use of Doppler echocardiographic guidance for PBAV is feasible, and that it is associated with a high success rate and a very low complication rate.

    Release date:2018-09-25 04:15 Export PDF Favorites Scan
  • Evaluation of coronary artery ostium obstruction caused by the commissure of transcatheter heart valve with the markers on transcatheter heart valve

    Objective To evaluate the coronary artery ostium obstruction caused by the commissure of transcatheter heart valve (THV) with the markers on THV under X-ray, which was identified by observing the position relationship between the commissure of THV and the coronary artery ostium from analyzing aortic root computed tomographic angiography (CTA) images after transcatheter aortic valve replacement (TAVR). Methods A retrospective analysis was performed on 25 patients undergoing TAVR who were checked with electrocardiographically gated CTA for the aortic root after the TAVR procedure between January 2020 and December 2021 in General Hospital of Northern Theater Command. The images of THV with the lowest position of non-coronary sinus and the right anterior oblique and caudal in most cases were observed when the THVs were deployed. The position relationships of the three markers on the THV after valve release were recorded, which were divided into three conditions, namely the three markers being averagely distributed, the middle marker being close to left, and the middle marker being close to right. Postoperative CTA images of the patients were analyzed. The angle between the commissure of THV and the coronary artery ostium was measured, and the angles in each group were presented as medium (lower quartile, upper quartile). Results A total of 17 patients were finally included. The angles between the commissure of THV and the left coronary artery ostium were 19.0 (16.0, 31.0)°, 36.0 (15.0, 44.0)°, and 3.0 (3.0, 5.0)° in the markers averagely distributed group (n=7), the middle marker close to left group (n=6), and the middle marker close to right group (n=4), respectively, which were significantly different (P=0.033). The angles between the commissure of THV and the right coronary artery ostium were 43.0 (25.0, 51.0)°, 47.0 (41.0, 57.0)°, and 13.0 (7.5, 21.0)° in the markers averagely distributed group, the middle marker close to left group, and the middle marker close to right group, respectively, which were significantly different (P=0.017). There was significant difference in the obstruction degrees of left coronary artery ostium by the commissure of THV (P=0.008), and no significant difference in the obstruction degrees of right coronary artery ostium (P=0.062). When the middle marker was close to right, there was no more than moderately obstruction on the right coronary artery ostium and no any obstruction on the left coronary artery ostium. When the middle marker was close to left, the obstruction rate of the left coronary artery ostium with more than moderate degree was 4/6 (66.7%) and it was 6/6 (100.0%) for the right coronary artery ostium. Conclusions The degree of coronary artery ostium obstruction by the commissure of THV can be accurately evaluated by using markers on THV. Among them, when the middle marker is close to right, the commissures of THV are least likely to block the coronary artery ostium.

    Release date:2022-05-24 03:47 Export PDF Favorites Scan
  • Mitral regurgitation during the transcatheter aortic valve replacement of a patient:a case report

    This article described the clinical diagnosis and treatment of a patient with bicuspid aortic stenosis occurring severe mitral regurgitation during transcatheter aortic valve replacement. Before transcatheter aortic valve replacement, the patient’s information about medical history, signs, evaluation of CT and echocardiography were collected. After discussion by the heart team, the trans-femoral aortic valve replacement was performed. After the valve was placed during the procedure, a severe mitral regurgitation occurred. No clear causes were found, and the patient’s hemodynamics was stable. The patient recovered well during follow-up, so surgery and other treatments were not considered. This article discussed the possible mechanism and solutions of mitral regurgitation during transcatheter aortic valve replacement, and owned certain value for similar cases to refer to.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan
  • Contrast-zero ultrasound-guided transcatheter aortic valve replacement: A case report

    Conventional transcatheter aortic valve replacement is normally recommended with transthoracic echocardiography, and contrast agent mediated fluoroscopy under anesthesia to guide a better implantation of the transcatheter valve. However, iodine-containing contrast agent possibly damages the patient’s kidney, and even induces the acute kidney injury. We reported a 75-year-old patient diagnosed with severe aortic valve stenosis, moderate regurgitation, and chronic renal failure. We performed the aortic valve replacement under the guidance of fluoroscopy and transesophageal ultrasound without contrast agent. Seven days after surgery, the patient recovered well and discharged with alleviated aortic stenosis and fixed transcatheter aortic valve.

    Release date:2023-03-01 04:15 Export PDF Favorites Scan
  • Preliminary clinical outcomes of the domestic Renatus® balloon-expandable valve system for the treatment of severe aortic stenosis: A prospective cohort study

    Objective To evaluate the early clinical outcomes of the Renatus® balloon-expandable valve in the treatment of severe aortic stenosis. MethodsFrom November 2021 to April 2022, a total of 38 patients who received Renatus® balloon-expandable valve for severe aortic stenosis in Guangdong Provincial People's Hospital were included. There were 22 males and 16 females, with an average age of 73.7±5.3 years. Mean aortic gradient and peak aortic jet velocity at baseline, post-procedure, and follow-up were compared. Clinical outcomes including all-cause mortality, perivalvular leakage, serious adverse cardiovascular events and the occurrence of permanent pacemaker implantation were assessed. ResultsAll patients completed the procedure successfully without conversion to thoracotomy or perioperative death. The post-implant mean aortic pressure gradient was decreased from 41.5 (27.8, 58.8) mm Hg to 6.0 (3.0, 8.0) mm Hg, and the peak aortic jet velocity was also decreased from 4.1±0.9 m/s to 1.7±0.4 m/s (P<0.001). Pacemakers were required in 2 (5.3%) patients. The median follow-up time was 27.5 (23.0, 87.5) d, with a follow-up rate of 100.0%. The mean aortic gradient was 8.0 (7.0, 10.8) mm Hg and peak aortic jet velocity was 2.0±0.3 m/s, showing significant improvement compared with those in the preoperative period (P<0.001). No severe aortic regurgitation or paravalvular leak was observed. There was no serious cardiovascular adverse event or reoperative event during the study period. ConclusionTranscatheter aortic valve replacement with the domestic Renatus® balloon-expandable valve system is a safe and effective procedure for selected patients with severe aortic stenosis who are at high risk or not candidates for surgical aortic valve replacement.

    Release date:2023-03-01 04:15 Export PDF Favorites Scan
  • A case of transcatheter aortic valve replacement of severe aortic stenosis with extremely low left ventricular ejection fraction

    An 82-year-old male was hospitalized complaining of dyspnea for 1 year and aggravating for 2 weeks. He had been treated in other hospitals for several times due to such situation and his symptom could be relieved by diuretics. After admission, he was diagnosed as severe aortic stenosis with extremely low left ventricular contractile function; transthoracic echocardiography showed a left ventricular ejection fraction of only 16.1%. He was classified as a typical case of severe aortic stenosis with “low transaortic velocity and low transaortic gradient” since the transaortic velocity being 2.36 m/s and transaortic gradient being 22/14 mm Hg (1 mm Hg=0.133 kPa). Dobutamine-stress echocardiography suggested that the patient’s left ventricular reserve function was extremely poor and the potential benefits of valvular surgery were finite as the former data being 2.59 m/s and 27/16 mm Hg respectively. In consideration of progressive exacerbation of the patient’s symptoms, we eventually conducted transcatheter aortic valve replacement surgery with the support of extracorporeal membrane oxygenation. His symptoms such as dyspnea disappeared after the surgery and clinical parameters had also got a significant improvement.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content