west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "aortic root" 29 results
  • Valve-sparing Aortic Root Replacement: Operation Outcomes and Mid-term Follow-up of De Paulis Valsalva Graf

    ObjectiveTo explore the effect of the reimplantation procedure with the De Paulis Valsalva graft in patients with aneurysms. MethodsWe retrospectively analyzed the clinical data of 38 patients underwent valve-sparing aortic root replacement using De Paulis graft in our hospital between September 2005 and July 2013.There were 32 male and 6 female patients at age of 45.5±12.4 years. We compared the parameters of pre-operation and post-operation and followed up the patients for 5 years. ResultsThere were 2(5.3%) deaths in hospital. The follow-up time was 2-95 months with following-up rate of 92.1%(35/38). A total of 2 patients(5.3%) had grade 3 to grade 4 aortic insufficiency. And one of these patients received aortic valve replacement after 1 year. At 5 years of following-up, one patient died of septic shock due to pacemaker infection. One patient died of kidney failure due to renal artery dissection aneurysm affected with impaired renal function and long-term hemodialysis. ConclusionThe reimplantation type of valve-sparing procedure can be facilitated by the use of the De Paulis valsalva graft and can be performed with satisfactory perioperative and mid-term results.

    Release date: Export PDF Favorites Scan
  • Effect of sinus diameter on the opening and closing performance of aortic valve under the expansion of aortic root

    This study aims to explore the effect of aortic sinus diameter on aortic valve opening and closing performance in the case of no obvious disease of aortic valve and annulus and continuous dilation of aortic root. A total of 25 three-dimensional aortic root models with different aortic sinus and root diameters were constructed according to the size of clinical surgical guidance. The valve sinus diameter DS is set to 32, 36, 40, 44 and 48 mm, respectively, and the aortic root diameter DA is set to 26, 27, 28, 29 and 30 mm, respectively. Through the structural mechanics calculation with the finite element software, the maximum stress, valve orifice area, contact force and other parameters of the model are analyzed to evaluate the valve opening and closing performance under the dilated state. The study found that aortic valve stenosis occurs when the DS = 32 mm, DA = 26, 27 mm and DS = 36 mm, DA = 26 mm. Aortic regurgitation occurs when the DS = 32, 36 and 40 mm, DA = 30 mm and DS = 44, 48 mm, DA = 29, 30 mm. The other 15 models had normal valve movement. The results showed that the size of the aortic sinus affected the opening and closing performance of the aortic valve. The smaller sinus diameter adapted with the larger root diameter and the larger sinus diameter adapted with the smaller root diameter. When the sinus diameter is 40 mm, the mechanical performance of the valve are good and it can well adapt with the relatively large range of aortic root dilation.

    Release date:2019-12-17 10:44 Export PDF Favorites Scan
  • Outcomes and preoperative evaluation of transfemoral transcatheter aortic valve replacement (TAVR) in the treatment of pure native aortic valve regurgitation

    ObjectiveTo assess outcomes of transcatheter aortic valve replacement (TAVR) for pure native aortic valve regurgitation.MethodsA total of 129 patients underwent transfemoral TAVR in Fuwai Hospital from May 2019 to October 2020 were retrospectively analyzed. There were 83 males and 46 females with an average age of 72.26±8.97 years. The patients were divided into a pure native aortic valve regurgitation group (17 patients) and an aortic valve stenosis group (112 patients).ResultsThe incidence of valve in valve was higher in the pure native aortic valve regurgitation group (47.0% vs. 16.1%, P<0.01). There was no statistical difference between the two groups in conversion to surgery, intraoperative use of extracorporeal circulation, intraoperative left ventricular rupture, postoperative use of extracorporeal membrane oxygenation (ECMO), peripheral vascular complications, disabled stroke, death, or pacemaker implantation. There was no statistical difference in the diameter of annulus (25.75±2.21 mm vs. 24.70±2.90 mm, P=0.068) or diameter of outflow tract (25.82±3.75 mm vs. 25.37±3.92 mm, P=0.514) between the pure native aortic valve regurgitation group and the aortic valve stenosis group.ConclusionTransfemoral TAVR is a feasible method for patients with pure native aortic valve regurgitation. The diameter of annulus plane, the diameter of outflow tract and the shape of outflow tract should be evaluated.

    Release date:2021-09-18 02:21 Export PDF Favorites Scan
  • Application of reimplantation in the treatment of bicuspid aortic valve with aortic root aneurysm

    Objective To evaluate the early clinical effect of reimplantation in the treatment of bicuspid aortic valve (BAV) with aortic root aneurysm. Methods The clinical data of 25 patients with BAV and aortic root aneurysm[mean diameter: 45-63 (52.68±5.55) mm] undergoing reimplantation in West China Hospital from November 2019 to May 2021 were retrospectively reviewed. There were 22 males and 3 females. The mean age was 15-65 (50.00±13.10) years and body surface area was 1.79±0.23 m2. ResultsThe pathological classification of BAV malformation was confirmed during the operation: Type 0 in 3 patients and Type 1 in 22 patients. There were 12 patients undergoing cusp central plication, and 2 patients were sutured with a closed fusion crest. Postoperative valve leaflet coaptation height was 0.78±0.15 cm, and effective height was 1.27±0.19 cm. In operation, maximum aortic valve flow velocity was 1.65±0.42 m/s, pressure difference was 5.46±3.05 mm Hg, and aortic valve annulus diameter was 21.32±0.95 mm. Cardiopulmonary bypass time was 225.84±35.34 min, and aortic block time was 189.60±26.51 min. In-hospital time was 11.64±3.07 d, ICU stay time was 2.64±0.99 d, and mechanical ventilation time was 1.48±0.87 d. The follow-up time was 17.20±4.70 months, and no death or major complications occurred during the follow-up in all patients. The cardiac function of the patients significantly improved postoperatively (P≤0.05). Echocardiography suggested that 12 patients had no aortic regurgitation, 10 minor aortic regurgitation, 3 mild aortic regurgitation, and no patients with moderate or more severe regurgitation. The diameter of the aortic sinus, left ventricular end-diastolic diameter and volume decreased during the follow-up, compared to preoperative ones (P≤0.05). The maximum flow velocity of the aortic valve was 1.54±0.36 m/s, and the pressure difference was 5.17±2.38 mm Hg during the follow-up. ConclusionReimplantation technology has a good clinical effect for highly selective BAV patients. It can effectively avoid long-term postoperative anticoagulation, but the maximum flow rate after surgery is slightly increased, which may be related to the configuration of BAV itself. While compared with valve replacement, the effect is still worthy of recognition.

    Release date:2022-10-26 01:37 Export PDF Favorites Scan
  • Modified Yacoub technique with aortic annuloplasty in patients with aortic root aneurysm

    ObjectiveTo evaluate the feasibility and safety of modified Yacoub technique with aortic annuloplasty in the patients with aortic root aneurysm and dilatation of aortic annular base.MethodsWe performed a retrospective review of 6 patients with aortic root aneurysm undergoing modified Yacoub technique with aortic annuloplasty from November 2017 to January 2019. There were 5 males and 1 female, with a mean age of 54.1±12.3 years. The preoperative cardiac function of 3 patients was in New York Heart Association (NYHA) classⅡand the other 3 patients were in class Ⅲ. There were two patients with bicuspid aortic valve, and no Marfan syndrome. There was aortic regurgitation in the patients measured by the echocardiogram, 1 in mild aortic regurgitation, 1 in moderate aortic regurgitation, and 4 in severe aortic regurgitation. The diameter of aortic annular base was 27.8±1.9 mm, and the largest diameter of aortic root was 49.8±3.7 mm. Six patients underwent modified Yacoub technique with aortic annuloplasty, including 5 patients who underwent aortic cusp repair at the same time.ResultsAll 6 identified patients survived. There was no severe complication (bleeding, stroke, or acute renal failure). The cardiopulmonary bypass time was 204.6±13.5 min, aortic cross-clamping time 168.0±17.1 min, mechanical ventilation time 21.3±19.5 h, ICU stay time 67.8±62.2 h. The follow-up time ranged from 4 to 18 months with an average time of 12.8±4.7 months. Patients' cardiac function improved postoperatively with four patients in NYHA classⅠand two patients with classⅡ. Two patients had no aortic valve regurgitation, four patients had mild regurgitation. Left ventricular end diastolic volume decreased significantly (118.6±20.4 mL vs. 169.1±58.4 mL, P<0.05).ConclusionThe modified Yacoub technique with aortic annuloplasty is effective and safe for the patients with aortic root aneurysm and dilatation of aortic annular base, and the early- and mid-term outcomes are satisfactory.

    Release date:2020-03-25 09:52 Export PDF Favorites Scan
  • Bentall procedure for reoperation in the small aortic root or annulus

    ObjectiveTo investigate and evaluate the safety and efficacy of Bentall operation in the reoperation of patients with small aortic root or annulus.MethodsBentall procedure was performed in 24 patients with small aortic root or annulus in our hospital from September 2014 to December 2019. There were 18 males and 6 females with a mean age of 31-68 (45.70±15.27) years. All patients had undergone a previous replacement of the aortic valve including 20 patients receiving valve replacement, 2 patients aortic root replacement with a valved conduit and 2 patients bioprothesis replacement.ResultsThere was no early death in hospital and one death during the 30-day postoperative period. Re-thoracotomy due to bleeding was necessary in only 2 patients and no bleeding was related to the proximal anastomosis of the conduit. One patient performed pacemaker implantation for heart block after the procedure. The mean sizes of implanted aortic valve prosthesis were 22.75±1.78 mm. A mean gradient across the aortic valve prostheses in the postoperative echocardiographic examination was 11.17±2.24 mm Hg.ConclusionBentall procedure is safe and allows a larger size of prosthesis implantation in patients with small aortic annulus or root after previous aortic valve or complete root replacement, resulting in good postoperative hemodynamic characteristics and short-term clinical results.

    Release date:2022-05-23 10:52 Export PDF Favorites Scan
  • Clinical effectiveness of valve-sparing aortic root replacement in the treatment of patients with dilated aortic root after operation for tetralogy of Fallot

    Objective To evaluate the clinical effectiveness of valve-sparing aortic root replacement (VSARR) in the treatment of patients with dilated aortic root after operation for tetralogy of Fallot (TOF). Methods A retrospective analysis was conducted on clinical data of TOF patients with aortic root dilation who underwent VSARR in our hospital from 2016 to 2022. Results Finally 14 patients were collected, including 8 males and 6 females, with a median age of 22 years ranging from 12-48 years. Among them, 5 patients had severe aortic valve regurgitation, 4 moderate regurgitation, and 5 mild or no regurgitation. Six patients had sinus of valsalva dilation, and 8 significant dilation of the ascending aorta. One patient had residual shunt due to ventricular septal defect, and 9 severe pulmonary valve regurgitation. The David procedure was performed in 10 patients, Yacoub procedure in 2 patients, and Florida sleeve in 2 patients. There was no perioperative mortality in the group. The median follow-up time was 2.9 years (ranging from 0.4 to 6.0 years). One patient had mild aortic valve regurgitation, and the rest had minimal or no regurgitation. One patient had mild stenosis of the left ventricular outflow tract, and the rest patients had no obvious stenosis. Conclusion VSARR is a satisfactory treatment for aortic root dilation in patients with TOF, with no significant increase in the incidence of left ventricular outflow tract stenosis or aortic regurgitation during mid-term follow-up.

    Release date: Export PDF Favorites Scan
  • Surgical strategy and clinical outcomes of reoperative aortic root replacement after prior aortic valve replacement

    ObjectiveTo summarize the surgical strategy of reoperative aortic root replacement after prior aortic valve replacement (AVR), and analyze the early and mid-term outcomes.MethodsFrom April 2013 to January 2020, 75 patients with prior AVR underwent reoperative aortic root replacement in Fuwai Hospital. There were 54 males and 21 females with a mean age of 56.4±12.7 years. An emergent operation was performed in 14 patients and an elective operation in 61 patients. The indications were aortic root aneurysm in 38 patients, aortic dissection involving aortic root in 30 patients, root false aneurysm in 2 patients, prosthesis valve endocarditis with root abscess in 2 patients, and Behçet's disease with root destruction in 3 patients. The survival and freedom from aortic events during the follow-up were evaluated with the Kaplan-Meier survival curve and the log-rank test.ResultsThe operative procedures included prosthesis-sparing root replacement in 45 patients, Bentall procedure in 26 patients, and Cabrol procedure in 4 patients. Operative mortality was 1.3% (1/75). A composite of adverse events occurred in 5 patients, including operative death (n=1), stroke (n=1), and acute renal injury necessitating hemodialysis (n=3). The follow-up was available for all 74 survivors, with the mean follow-up time of 0.5-92.0 (30.3±25.0) months. Four late deaths occurred during the follow-up. The survival rate at 1 year, 3 years and 6 years was 97.2%, 91.4% and 84.4%, respectively. Aortic events developed in 2 patients. The rate of freedom from aortic events at 1 year, 3 years, and 6 years was 98.7%, 95.0% and 87.7%, respectively. There was no difference in rate of survival or freedom from aortic events between the elective patients and the emergent patients.ConclusionReoperative aortic root replacement after prior AVR can be performed to treat the root pathologies after AVR, with acceptable early and mid-term outcomes.

    Release date:2023-02-03 05:31 Export PDF Favorites Scan
  • Aortic-mitral annular enlargement technique in re-valve surgery: A retrospective study in a single center

    Objective To investigate and evaluate the safety and efficacy of the aortic-mitral annular enlargement technique (double annular enlargement) in patients with small-size valve prostheses after prior valve surgery. MethodsThe clinical data of patients who underwent double valve annular enlargement in Wuhan Asia Heart Hospital from April 2020 to April 2022 were retrospectively analyzed. Results A total of 30 patients were collected, including 2 males and 28 females aged 9-78 (52.71±3.53) years. All patients had previous heart valve surgery, including 1 patient receiving the third heart surgery. All patients were operated on successfully and there were no postoperative in-hospital deaths. There was no postoperative bleeding which needed a secondary open-chest hemostasis, and one patient underwent permanent pacemaker implantation due to postoperative sick sinus syndrome. The mean diameter of the implanted prosthetic aortic valve was 24.23±1.60 mm, which was significantly larger than that of the preoperative aortic valve (21.03±1.90 mm, P<0.001). The mean diameter of the implanted prosthetic mitral valve was 28.33±1.21 mm, which was significantly larger than that of the preoperative mitral valve (25.43±0.84 mm, P<0.001). The mean peak gradient difference across the prosthetic aortic valve on postoperative echocardiography was 18.17±6.44 mm Hg, which was significantly lower than that of the preoperative aortic valve (82.57±24.48 mm Hg, P<0.001). The mean peak gradient difference of the postoperative prosthetic mitral valve was 12.73±5.45 mm Hg, which was significantly lower than that of the preoperative mitral valve (19.43±8.97 mm Hg, P=0.003). Conclusion The double annular enlargement technique is safe and effective for reoperation in patients with a history of valve surgery with a small aortic root to obtain both a larger size prosthetic valve for a larger orifice area and stability of the mitral-aortic valve union, resulting in good postoperative hemodynamic characteristics and clinical outcomes.

    Release date:2024-05-28 03:37 Export PDF Favorites Scan
  • Progress in Valve-sparing Aortic Root Replacement

    Abstract: Replacement of the aortic valve and aortic root has been the standard surgical strategy for patients with aortic root aneurysm for many years. Along with the increasing knowledge about the aortic root anatomy and physiology, and complications after aortic valve replacement, the technique of valve-sparing aortic root replacement has developed greatly. We focus on the etiology and classification aortic valve insufficiency, the valve-sparing techniques and clinical outcomes of valve-sparing aortic root replacement in this review.

    Release date:2016-08-30 05:49 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next