find Keyword "aortic regurgitation" 19 results
  • Transapical transcatheter aortic valve replacement using Ken-Valve for pure severe aortic regurgitation: A case report

    Transcatheter aortic valve replacement (TAVR) has become the preferred treatment for severe aortic stenosis. The localization and anchor of many transcatheter heart valves available in the clinic today are dependent on the calcific aortic valve leaflet of patients. We reported here a successful case of transapical aortic valve implantation with Ken-Valve heart valve in an 82-year-old male patient with pure severe aortic regurgitation without native valve calcium. Postoperative follow-up (3 months after the surgery) showed that the cardiac function significantly improved. The echocardiography indicated that the Ken-Valve prosthesis worked well without perivalvular regurgitation. The short-term clinical effect was satisfactory. The Ken-Valve with three position anchors is proved to be suitable for the treatment of pure aortic regurgitation.

    Release date:2022-08-25 08:52 Export PDF Favorites Scan
  • The clinical effect of a combined technical system for bicuspid aortic valves repair

    ObjectiveTo summarize the clinical result of a combined technical system for bicuspid aortic valve (BAV) repair. MethodsPatients who diagnosed as BAV and sever aortic regurgitation (AR) underwent a strategy of combined repair technics including annuloplasty, sinus plasty, leaflet plasty, sinus-tubular junction (STJ) plasty depending on anatomy pathological characteristics between October 2019 and January 2021 were enrolled. The clinical data of the patients were analyzed.ResultsA total of 17 patients were enrolled. There were 11 males and 6 females with an average age of 18-49 (32.4±13.6) years. Fifteen patients had typeⅠand 2 patients had typeⅡBAV according to Sievers classification. Annuloplasty was applicated in 13 patients, sinus plasty in 8 patients, leaflet plasty in 17 patients, and STJ plasty in 11 patients, respectively. The cardiopulmonary bypass (CPB) time was 95 (84, 135) min, aortic cross-clamping time was 68 (57, 112) min, and the ICU stay time was 17 (12, 25) h. After the operation, mild AR was presented in 14 patients, moderate AR in 1 patient and severe AR in 2 patients. The latter 3 patients underwent second operation under CPB, after then, 1 patient had mild AR and 2 patients had moderate AR. The follow-up time was 13.1±4.6 months. At the latest follow-up, 12 patients had mild AR and 5 patients had moderate AR, and no patient had reoperation. ConclusionA combined technical system for BAV repair can be used effectively and safely with an acceptable short and middle-term result.

    Release date:2023-07-10 04:06 Export PDF Favorites Scan
  • Procedure specifications for transapical transcatheter aortic valve replacement

    Transcatheter aortic valve replacement (TAVR) techniques have been rapidly developed in recent years. Current guidelines and studies mainly focus on aortic stenosis patients treated by transfemoral approach, but they are not completely appropriate to patients with isolated aortic regurgitation or other patients who need transapical TAVR (TA-TAVR), which affects the standardized treatment of those patients. Therefore, our team pronounced the operational standards for TA-TAVR, based on fully reviewing the literatures worldwide, combined with the opinions of experts from 15 heart centers with rich experience in carrying out TA-TAVR in China. This standard aims to provide clinicians with standardized diagnosis and treatment principles of TA-TAVR and improve the quality of TA-TAVR in China.

    Release date:2023-03-24 03:15 Export PDF Favorites Scan
  • Risk factors and management experiences of stent valves detachment in transcatheter aortic valve implantation (TAVI)

    ObjectiveTo summarize and analyze the risk factors and management of artificial valve slippage in transcatheter aortic valve implantation (TAVI).MethodsWe retrospectively analyzed the clinical data of 131 patients undergoing TAVI surgery in our center from September 2017 to May 2019, including 62 patients through transapical approach and 69 patients through transfemoral artery approach.ResultsA total of 131 patients received TAVI surgery, among whom 4 patients had slipped during the operation, 2 patients via transfemoral artery approach, and another 2 patients via transapical. The average age was 77±9 years with one female (25%). Preoperative evaluation, higher position and poor coaxial were main risk factors for valve slip in TAVI.ConclusionValve slippage is also a serious complication in TAVI surgery. Reasonable and effective treatment can avoid thoracotomy.

    Release date:2020-07-30 02:16 Export PDF Favorites Scan
  • Simultaneous TAVI and McKeown for esophageal cancer with severe aortic regurgitation: A case report

    A 71-year-old male presented with esophageal cancer and severe aortic valve regurgitation. Treatment strategies for such patients are controversial. Considering the risks of cardiopulmonary bypass and potential esophageal cancer metastasis, we successfully performed transcatheter aortic valve implantation and minimally invasive three-incision thoracolaparoscopy combined with radical resection of esophageal cancer (McKeown) simultaneously in the elderly patient who did not require neoadjuvant treatment. This dual minimally invasive procedure took 6 hours and the patient recovered smoothly without any surgical complications.

    Release date:2025-01-21 11:07 Export PDF Favorites Scan
  • Mid-to-long term fate of neo-aortic root after arterial switch operation for Taussig-Bing anomaly: A retrospective study in a single center

    ObjectiveTo explore growth pattern of neo-aortic root as well as development of neo-aortic regurgitation after arterial switch operation (ASO) for Taussig-Bing anomaly. MethodsFrom 2002 to 2017, the patients who received ASO, and were discharged alive from Shanghai Children’s Medical Center and followed up for more than 3 years were retrospectively involved in this study. ResultsA total of 127 patients were enrolled. There were 98 (77.2%) males, the median age at ASO was 73.0 d and the average weight was 4.7 kg. Forty-five (35.4%) children were complicated with mild or mild-to-moderate pulmonary insufficiency (PI) before ASO. The average follow-up time was 7.0 years. During the follow-up, 14 (11.0%) children presented moderate or greater neo-aortic regurgitation (neo-AR). The diameter of neo-aortic annulus and sinus of Valsalva was beyond normal range during the entire follow-up. The average diameter of neo-aortic annulus was 18.0 mm at 5 years and 20.5 mm at 10 years. The average diameter of sinus of Valsalva was 25.9 mm at 5 years and 31.1 mm at 10 years. Neo-AR continued to develop over time. The diameter of children who developed moderate or greater neo-AR was constantly larger than that of children who did not (χ2=18.3, P<0.001). Preoperative mild or mild-to-moderate PI was an independent risk factor for the development of moderate or greater neo-AR during mid-to-long term follow-up (c-HR=3.46, P=0.03). ConclusionThe diameters of neo-aortic annulus and sinus of Valsalva of Taussig-Bing children who receive ASO repair continue to expand without normalization. The dilation of annulus correlates with the development of neo-AR. PI before ASO repair increases the risk of neo-AR development.

    Release date:2024-04-28 03:40 Export PDF Favorites Scan
  • Application of reimplantation in the treatment of bicuspid aortic valve with aortic root aneurysm

    Objective To evaluate the early clinical effect of reimplantation in the treatment of bicuspid aortic valve (BAV) with aortic root aneurysm. Methods The clinical data of 25 patients with BAV and aortic root aneurysm[mean diameter: 45-63 (52.68±5.55) mm] undergoing reimplantation in West China Hospital from November 2019 to May 2021 were retrospectively reviewed. There were 22 males and 3 females. The mean age was 15-65 (50.00±13.10) years and body surface area was 1.79±0.23 m2. ResultsThe pathological classification of BAV malformation was confirmed during the operation: Type 0 in 3 patients and Type 1 in 22 patients. There were 12 patients undergoing cusp central plication, and 2 patients were sutured with a closed fusion crest. Postoperative valve leaflet coaptation height was 0.78±0.15 cm, and effective height was 1.27±0.19 cm. In operation, maximum aortic valve flow velocity was 1.65±0.42 m/s, pressure difference was 5.46±3.05 mm Hg, and aortic valve annulus diameter was 21.32±0.95 mm. Cardiopulmonary bypass time was 225.84±35.34 min, and aortic block time was 189.60±26.51 min. In-hospital time was 11.64±3.07 d, ICU stay time was 2.64±0.99 d, and mechanical ventilation time was 1.48±0.87 d. The follow-up time was 17.20±4.70 months, and no death or major complications occurred during the follow-up in all patients. The cardiac function of the patients significantly improved postoperatively (P≤0.05). Echocardiography suggested that 12 patients had no aortic regurgitation, 10 minor aortic regurgitation, 3 mild aortic regurgitation, and no patients with moderate or more severe regurgitation. The diameter of the aortic sinus, left ventricular end-diastolic diameter and volume decreased during the follow-up, compared to preoperative ones (P≤0.05). The maximum flow velocity of the aortic valve was 1.54±0.36 m/s, and the pressure difference was 5.17±2.38 mm Hg during the follow-up. ConclusionReimplantation technology has a good clinical effect for highly selective BAV patients. It can effectively avoid long-term postoperative anticoagulation, but the maximum flow rate after surgery is slightly increased, which may be related to the configuration of BAV itself. While compared with valve replacement, the effect is still worthy of recognition.

    Release date:2022-10-26 01:37 Export PDF Favorites Scan
  • Transcatheter aortic valve replacement for aortic regurgitation complicated by Takayasu arteritis: A case report

    Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up period. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.

    Release date: Export PDF Favorites Scan
  • Advances of aortic valve repair for aortic regurgitation

    The first aortic valve repair was performed in 1958, but the clinical outcome was limited. Since the invention of prosthetic valves, aortic valve replacement has become and still maintained the dominated surgical treatment option. As the impact of the prosthetic valve-related event to quality of life of the patients and the studies of the mechanism of aortic regurgitation and the functional anatomy of aortic root grow, the application of aortic valve repair gets more popular, and the short- and mid-term outcomes are good.

    Release date:2018-01-31 02:46 Export PDF Favorites Scan
  • Short and mid-term outcomes of valve repair in patients with insufficient bicuspid aortic valves

    ObjectiveTo evaluate the short and mid-term outcomes of valve repair in patients with insufficient bicuspid aortic valves (BAV).MethodsThe clinical data of 27 consecutive patients with insufficient BAV undergoing valve repair in Shanghai Chest Hospital from September 2016 to January 2020 were retrospectively reviewed. There were 24 males and 3 females with a mean age of 38.5±14.6 years (range: 20-68 years). BAV of all patients was type 1 in Seviers' classification. There were 23 patients with left-right fusion and 4 patients with right-noncoronary fusion. There was aortic regurgitation in the patients measured by the echocardiogram, including moderate regurgitation in 3 patients, moderate-severe in 18 patients, and severe in 6 patients. The diameter of aortic annular base was 27.9±3.4 mm, and the largest diameter of aortic sinus was 39.9±7.6 mm. Left ventricular end diastolic diameter was 62.7±6.5 mm, and the volume was 197.9±53.6 mL.ResultsAll 27 patients completed the follow-up, and the mean time was 24.2±12.5 months (range: 12-51 months). No patient died or required aortic valve-related reoperation during the follow-up. The cardiac function of the patients significantly improved postoperatively (P<0.05). By echocardiography, 11 patients had no aortic regurgitation, 13 had mild aortic regurgitation, and 3 had moderate aortic regurgitation, and no patient had severe aortic regurgitation. Postoperative left ventricular end diastolic diameter and volume decreased, compared to preoperative ones (P<0.05).ConclusionIn patients with insufficient BAV, valve repair is safe and effective, and has excellent short and mid-term outcomes.

    Release date:2021-12-27 11:31 Export PDF Favorites Scan
2 pages Previous 1 2 Next