west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "alignment" 36 results
  • EFFECT OF MEDIAL 1/3 ANATOMICAL ORIENTATION OF TIBIAL TUBERCLE ON ROTATIONAL ALIGNMENT OF Gemini MK-Ⅱ TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY

    ObjectiveTo investigate the effect of medial 1/3 anatomical orientation of the tibial tubercle on the rotational alignment of Gemini MK-Ⅱ tibial components in total knee arthroplasty (TKA). MethodsBetween March 2011 and December 2012, 61 cases (67 knees) of varus knee osteoarthritis underwent Gemini MK-Ⅱ knee arthroplasty, and the clinical data were retrospectively analyzed. There were 12 males and 49 females, with an average age of 67.6 years (range, 50-82 years). The body mass index ranged from 20.9 to 33.7 kg/m2 (mean, 28.2 kg/m2). Unilateral TKA was performed in 55 cases and bilateral TKA in 6 cases. The duration of knee osteoarthritis ranged from 2 to 30 years (mean, 12.1 years). According to radiographic changes, 56 knees were rated as Kellgren-Lawrence grade Ⅲ and 11 knees as grade IV. During TKA, the tibial rotational alignment was determined by medial 1/3 anatomical orientation of the tibial tubercle. The anteroposterior and lateral X-ray films and CT scan were taken to measure the tibial rotational angle (TRA) at pre-and post-operation and to analyze the relative factors for TRA by Pearson correlation analysis. ResultsAll the patients were followed up 18-41 months (mean, 20.5 months). The range of motion (ROM) significantly increased from (98.806±16.969)° preoperatively to (116.806±11.458)° at last follow-up (t=-11.760, P=0.000). The knee society score (KSS) significantly increased from 111.239±20.344 to 160.522±17.872 at last follow-up (t=-27.271, P=0.000). The anatomical tibiofemoral angle (ATFA), posterior condylar angle (PCA), and TRA were all improved after TKA, showing significant differences when compared with preoperative ones (P<0.05). Rotational malalignment was observed in 11 knees (16.42%) before TKA, and in 14 knees (20.90%) at 1 week after TKA, showing no significant difference (χ2=0.443, P=0.506). There were 8 knees (11.94%) of internal rotation (>8°) and 6 knees (8.96%) of external rotation (>8°). The postoperative tibial prosthesis TRA had no correlation with the preoperative ATFA and tibial plateau TRA, the postoperative PCA and ATFA (r=-0.174, P=0.159; r=0.220, P=0.074; r=0.237, P=0.053; r=-0.095, P=0.442). ConclusionIn patients with varus knee osteoarthritis, medial 1/3 anatomical orientation of the tibial tubercle will contribute to the development of tibial rotational malalignment when TKA is performed by using Gemini MK-Ⅱ tibial components.

    Release date: Export PDF Favorites Scan
  • INFLUENCES OF PREOPERATIVE SEVERE LOWER LIMB DEFORMITY ON PROSTHESIS INSTALLATION AND ALIGNMENT RESTORATION IN TOTAL KNEE ARTHROPLASTY

    ObjectiveTo investigate the effect of preoperative valgus or varus deformity on the prosthesis installation and alignment restoration in total knee arthroplasty (TKA). MethodsBetween January 2012 and December 2013, 198 patients (245 knees) with osteoarthritis underwent primary TKA, and the clinical data were retrospectively analyzed. There were 23 males and 175 females, with the average age of 67 years (range, 43-90 years). Single knee and double knees were involved in 151 and 47 cases respectively. The disease duration was from 1 month to 30 years (mean, 8.99 years). The anteroposterior X-ray films of whole lower limbs were taken, and the femorotibial angle (FT) was measured before operation and at 1 week after operation; the mechanical femoral angle (MF) and the anatomical tibial angle (AT) at 1 week after operation were measured. The correlation analysis was made for pre-and post-operative FT, MF, and AT. According to the valgus or varus deformity before operation, all patients were divided into 5 groups:≥20° varus (group A), 10-20° varus (group B), ≤10° varus (group C), < 10° valgus (group D), and≥10° valgus (group E), and the above indicators were compared between groups. And the rate of the good limb alignment was recorded after operation. ResultsThe pre-and post-operative FT were (171.53±9.12) and (177.38±3.57)° respectively, and postoperative MF and AT were (89.00±2.68) and (88.62±2.16)° respectively. Preoperative FT was associated with postoperative FT and MF (r=0.375, P=0.000; r=0.386, P=0.000), but it was not correlated with AT (r=0.024, P=0.710). Postoperative FT was associated with MF and AT (r=0.707, P=0.000; r=0.582, P=0.000). Postoperative FT was significantly increased when compared with preoperative FT in each group (P < 0.05). There were significant differences in preoperative FT between groups (P < 0.05). There were significant differences in postoperative FT when compared group A with groups B, C, D, and E (P < 0.05), and when compared groups B and C with groups D and E (P < 0.05), but there was no significant difference between groups B and C, and between groups D and E (P>0.05). The rate of good alignment was 70.2% (172/245); it was 27.8% (5/18), 66.0% (62/94), 74.4% (67/90), 88.9% (32/36), and 85.7% (6/7) in groups A, B, C, D, and E respectively, showing significant differences between groups (P < 0.05). There was no significant difference in postoperative AT between groups (P>0.05). Except for between group D and group E (P>0.05), significant difference in MF was shown between the other groups (P < 0.05). ConclusionThe more severe deformity of lower limb before TKA, the higher risk of deviation for prosthesis installation and poor alignment in TKA.

    Release date: Export PDF Favorites Scan
  • ROTATIONAL LANDMARKS AND TOTAL KNEE ARTHROPLASTY IN OSTEOARTHRITIC KNEES

    Objective To investigate the rotational mismatch of total kneereplacement with medial 1/3 of tibial tuberosity as bony landmark in osteoarthritic patients with varus or valgus deformity. Methods Axial images on computed tomography of 62 knees (including 55 varus deformities and 7 valgus deformities) in 32 Chinese osteoarthritic patients who had total knee arthroplasty were analyzed, compared with that of 10 healthy knees. On images of the distal femur, the angle between the lines of surgical epicondylar axis(SEA) and posterior condylar axis was measured as posterior condylar angle (PCA), and on images of the proximal tibia, a baseline for the anteriorposterior axis of each component was drawn based on the SEA for the femur and the medial 1/3 of the tibial tuberosity for the tibia. The angle between these lines (Angle α) was defined as therotational mismatch between the components when they were aligned to the anatomic landmarks of each bone. Results The sulcus of medial epicondyle of femur could be identified on CT images of over 80% osteoarthritic knees; the median value of PCA was +2.36°, with an individual variation of 0° to +7.5°. Angle α was +6.45±3.68°(range, 0° to +11.8°) in 10 healthy knees, which increased significantly to +10.85±10.47°(range, 0° to +28.1°)in 55 varus knees (P<0.05), which also increased significantly to +11.6±7.3°(range, -6.5° to +26.8°) in 7 valgus knees (P< 0.05). Conclusion With the medial 1/3 of the tibial tuberosity as the rotational landmark for the tibial component, there was a tendency to align the tibial component in external rotational position relative to the femoral component in knees with normal alignment, the rotational mismatch increased in Chinese osteoarthritic knees with varus and valgus deformity.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • INFLUENCE OF POSTERIOR CONDYLAR OFFSET AND ANTEROPOSTERIOR FEMOROTIBIAL TRANSLATION ON KNEEFLEXION AFTER POSTERIOR CRUCIATE-SACRIFICING SELF ALIGNMENT BEARING TOTAL KNEE ARTHROPLASTY

    Objective To observe the posterior condylar offset (PCO) changes and anteroposterior femorotibial translation, to investigate the influence of them on the maximum knee range of flexion (ROF) in patients with posterior cruciatesacrificingself al ignment bearing total knee arthroplasty (TKA). Methods The cl inical data were analyzed retrospectively from 40 patients (40 knees) undergoing primary unilateral TC-PLUSTM SB posterior cruciate-sacrificing self al ignment andbearing TKA for osteoarthritis between January 2007 and June 2009. There were 18 males and 22 females with an average age of 70.6 years (range, 56-87 years). The disease duration was 5-14 years (mean, 9.1 years). The locations were the left side in 11 cases and the right side in 29 cases. Preoperative knee society score (KSS) and ROF were 48.0 ± 5.5 and (77.9 ± 9.0)°, respectively. The X-ray films were taken to measure PCO and anteroposterior femorotibial translation. Multi ple regression analysis was performed based on both the anteroposterior femorotibial translation and PCO changes as the independent variable, and maximum knee flexion as the dependent variable. Results All incisions healed by first intention. The patients were followed up 12-19 months (mean, 14.7 months). At last follow-up, there were significant differences in the KSS (91.9 ± 3.7, t=— 77.600, P=0.000), the ROF [(102.0 ± 9.3)°, t=— 23.105, P=0.000] when compared with preoperative values. Significant difference was observed in PCO (t=3.565, P=0.001) between before operation [(31.6 ± 5.5) mm] and at last follow-up [(30.6 ± 5.9) mm]. At ast follow-up, the anteroposterior femorotibial translation was (— 1.2 ± 2.1) mm (95%CI: — 1.9 mm to — 0.6 mm); femoral roll forward occurred in 27 cases (67.5%), no roll in 1 case (2.5%), and femoral roll back in 12 cases (30.0%). By multiple regression analysis (Stepwise method), the regression equation was establ ished (R=0.785, R2=0.617, F=61.128, P=0.000). Anteroposterior femorotibial translation could be introducted into the equation (t=7.818, P=0.000), but PCO changes were removed from the equation (t=1.471, P=0.150). Regression equation was y=25.587+2.349x. Conclusion Kinematics after TC-PLUSTM SB posterior cruciate-sacrificing self al ignment bearing TKA with posterior cruciate l igament-sacrificing show mostly roll forwardof the femur relative to the tibia, which have a negative effect on postoperative range of motion. There is no correlation between PCO changes and postoperative change in ROF in TC-PLUSTM SB posterior cruciate-sacrificing self al ignment bearing TKA.

    Release date:2016-08-31 05:41 Export PDF Favorites Scan
  • Effect of three-dimensional printing guide plate on improving femoral rotational alignment and patellar tracking in total knee arthroplasty

    ObjectiveTo investigate the effect of three-dimensional (3D) printing guide plate on improving femoral rotational alignment and patellar tracking in total knee arthroplasty (TKA).MethodsBetween January 2018 and October 2018, 60 patients (60 knees) with advanced knee osteoarthritis who received TKA and met the selection criteria were selected as the study subjects. Patients were randomly divided into two groups according to the random number table method, with 30 patients in each group. The TKA was done with the help of 3D printing guide plate in the guide group and following traditional procedure in the control group. There was no significant difference in gender, age, disease duration, side, and preoperative hip-knee-ankle angle (HKA), posterior condylar angle (PCA), patella transverse axis-femoral transepicondylar axis angle (PFA), Hospital for Special Surgery (HSS) score, and American Knee Society (AKS) score (P>0.05).ResultsAll incisions healed by first intention and no complications related to the operation occurred. All patients were followed up 10-12 months, with an average of 11 months. HSS score and AKS score of the two groups at 6 months after operation were significantly higher than those before operation (P<0.05), but there was no significant difference between the two groups (P>0.05). Postoperative X-ray films showed that the prosthesis was in good position, and no prosthesis loosening or sinking occurred during follow-up. HKA, PCA, and PFA significantly improved in the two groups at 10 months after operation compared with those before operation (P<0.05). There was no significant difference in HKA at 10 months between the two groups (t=1.031, P=0.307). PCA and PFA in the guide group were smaller than those in the control group (P<0.05).ConclusionApplication of 3D printing guide plate in TKA can not only correct the deformity of the knee joint and alleviate the pain symptoms, but also achieve the goal of the accurate femoral rotation alignment and good patellar tracking.

    Release date:2020-04-15 09:18 Export PDF Favorites Scan
  • Early effectiveness of navigation-free robot-assisted total knee arthroplasty in treating knee osteoarthritis with extra-articular deformities

    Objective To evaluate the early effectiveness of navigation-free robot-assisted total knee arthroplasty (TKA) compared to traditional TKA in the treatment of knee osteoarthritis combined with extra-articular deformities. Methods The clinical data of 30 patients with knee osteoarthritis combined with extra-articular deformities who met the selection criteria between June 2019 and January 2024 were retrospectively analyzed. Fifteen patients underwent CORI navigation-free robot-assisted TKA and intra-articular osteotomy (robot group) and 15 patients underwent traditional TKA and intra-articular osteotomy (traditional group). There was no significant difference in age, gender, body mass index, affected knee side, extra-articular deformity angle, deformity position, deformity type, and preoperative knee range of motion, American Knee Society (KSS) knee score and KSS function score, and lower limb alignment deviation between the two groups (P>0.05). The operation time, intraoperative blood loss, and complications of the two groups were recorded and compared. The knee range of motion and lower limb alignment deviation were recorded before operation and at 6 months after operation, and the knee joint function was evaluated by KSS knee score and function score. Results There was no significant difference in operation time between the two groups (P>0.05); the intraoperative blood loss in the robot group was significantly less than that in the traditional group (P<0.05). Patients in both groups were followed up 6-12 months, with an average of 8.7 months. The incisions of all patients healed well, and there was no postoperative complication such as thrombosis or infection. At 6 months after operation, X-ray examination showed that the position of the prosthesis was good in both groups, and there was no loosening or dislocation of the prosthesis. The knee joint range of motion, the lower limb alignment deviation, and the KSS knee score and KSS function score significantly improved in both groups (P<0.05) compared to preoperative ones. The changes of lower limb alignment deviation and KSS function score between pre- and post-operation in the robot group were significantly better than those in the traditional group (P<0.05), while the changes of other indicators between pre- and post-operation in the two groups were not significant (P>0.05). Conclusion Compared to traditional TKA, navigation-free robot-assisted TKA for knee osteoarthritis with extra-articular deformities results in less intraoperative blood loss, more precise reconstruction of lower limb alignment, and better early effectiveness. However, long-term effectiveness require further investigation.

    Release date:2025-01-13 03:55 Export PDF Favorites Scan
  • Research status of commissural alignment between biological valve and autologous valve in transcatheter aortic valve replacement

    Commissural misalignment of biological valve and autologous valve during transcatheter aortic valve replacement may affect the filling of coronary artery, reduce the feasibility of redo-aortic valve intervention and damage the valve function, which will adversely affect long-term prognosis of patients. Some studies have obtained achievement by changing the axial direction of valve and using individualized computer simulation technology to improve the alignment technology. However, there are still many unknown problems about the impact of commissural misalignment on patients, and accurate commissural alignment techniques still need to be further explored. This article systematically expounds the possible impact of commissural misalignment between biological valve and autologous valve in transcatheter aortic valve replacement, possibly effective accurate commissural alignment techniques and related research progress.

    Release date:2022-05-24 03:47 Export PDF Favorites Scan
  • Imaging study on effect of femoral intramedullary guide on the alignment of femoral prosthesis in unicompartmental knee arthroplasty

    ObjectiveTo explore the imaging features of intramedullary guide rod and its influence on the alignment of the femoral prosthesis in unicompartmental knee arthroplasty (UKA). MethodsBetween August 2016 and November 2016, 50 patients (50 knees) with primary anteromedial osteoarthritis were treated with UKA by Oxford MicroPlasty minimally invasive replacement system. There were 10 males and 40 females. The age ranged from 62 to 77 years with an average of 68.8 years. Preoperative varus and flexion deformity angles were (5.22±3.46)° and (7.42±2.65)°, respectively. The knee range of motion (ROM) was (106.85±7.62)°. The Hospital for Special Surgery (HSS) score was 68.26±4.65. The angles between the femoral intramedullary guide rod and the anatomical axis of femur on the coronal and sagittal planes, the femoral component valgus/varus angle (FCVA), the femoral component posterior slope angle (FCPSA), knee varus deformity angle, and knee flexion deformity angle were measured by intra- and post-operative X-ray films. The postoperative ROM and HSS score were measured. ResultsIntraoperative X-ray films measurement showed that the lateral side angles between femoral intramedullary guide rod and femoral anatomical axis were observed on coronal plane, and the angles ranged from 0.28 to 2.06° with an average of 0.96°. While the posterior side angles were observed on sagittal plane, and the angles ranged from 0.09 to 0.48° with an average of 0.23°. The angulations (>1°) between femoral intramedullary part guide rod and outside part of the rod were confirmed in 12 cases (24%) on coronal plane. Postoperative femoral prosthesis were mild varus in 38 patients (76%). The FCVA ranged from –1.76 to 4.08° with an average of 2.21°. The FCPSA ranged from 7.12 to 13.86° with an average of 9.16°. All patients were followed up 22-26 months, with an average of 24.5 months. The incisions healed by first intention. At last follow-up, the varus and flexion deformity angles were (1.82±1.05) and (2.54 ± 1.86)°, respectively. ROM was (124.62±5.85)° and HSS score was 91.58±3.65. There were significant differences between pre- and post-operative parameters (P<0.05). No complication such as dislocation or aseptic loosening of the prosthesis occurred during the follow-up. ConclusionUKA by Oxford MicroPlasty minimally invasive replacement system can obtain accurate femoral prosthesis position with the help of intramedullary guide system, and the effectiveness is excellent.

    Release date:2019-01-03 04:07 Export PDF Favorites Scan
  • The Nursing Experience of Preoperative Treatment for Urethral Injury with Ureteroscopic Urethral Realignment

    ObjectiveTo explore the nursing experience of preoperative treatment for urethral injury with ureteroscopic urethral realignment. MethodsThe key points of the nursing experience of preoperative treatment for 58 cases of urethral injury with ureteroscopic urethral realignment were retrospectively analyzed. The patients were treated between January 2008 and December 2012. ResultsUrethra catheterization of the 58 patients receiving the ureteroscopic urethral realignment was all successful. The catheter was extracted 4-8 weeks after the treatment, and then the urethra was dilated for two years. All patients had normal urination without any surgery complications during the 5-28-month clinical follow-up. ConclusionUrinary tract infections can be prevented effectively under professional and meticulous preoperative treatment. The incidence of urethral stricture can be reduced greatly. The quality of the patients' life can be improved a lot.

    Release date: Export PDF Favorites Scan
  • Effect of different electrical stimulation waves on orientation and alignment of adipose derived mesenchymal stem cells

    ObjectiveTo investigate the effect of different electrical stimulation waves on orientation and alignment of adipose derived mesenchymal stem cells (ADSCs).MethodsADSCs were isolated from 5-week-old Sprague Dawley rats (weight, 100-150 g) and cultivated. The cells at passages 3-5 were inoculated to prepare cell climbing slices, subsequently was exposed to direct-current electrical stimulations (ES) at electric field strengths of 1, 2, 3, 4, 5, and 6 V/cm on a homemade electric field bioreactor (groups A1, A2, A3, A4, A5, and A6); at electric field strength of 6 V/cm, at 50% duty cycle, and at frequency of 1 and 2 Hz (groups B1 and B2) of square wave ES; at electric field strength of 6 V/cm, at pulse width of 2 ms, and at frequency of 1 and 2 Hz (groups C1 and C2) of biphasic pulse wave ES; and no ES was given as a control (group D). The changes of cellular morphology affected by applied ES were evaluated by time-lapse micropho-tography via inverted microscope. The cell alignment was evaluated via average orientation factor (OF). The cytoske-leton of electric field treated ADSCs was characterized by rhodamine-phalloidin staining. The cell survival rates were assessed via cell live/dead staining and intracellular calcium activities were detected by calcium ion fluorescent staining.ResultsThe response of ADSCs to ES was related to the direct-current electric field intensity. The higher the direct-current electric field intensity was, the more cells aligned perpendicular to the direction of electric field. At each time point, there was no obvious cell alignment in groups B1, B2 and C1, C2. The average OF of groups A5 and A6 were significantly higher than that of group D (P<0.05), but no significant difference was found between other groups and group D (P>0.05). The cytoskeleton staining showed that the cells of groups A5 and A6 exhibited a compact fascicular structure of cytoskeleton, and tended to be perpendicular to the direction of the electric field vector. The cellular survival rate of groups A4, A5, and A6 were significantly lower than that of group D (P<0.05), but no significant difference was found between other groups and group D (P>0.05). Calcium fluorescence staining showed that the fluorescence intensity of calcium ions in groups A4, A5, and A6 was slightly higher than that in group D, and no significant difference was found between other groups and group D.ConclusionThe direct-current electric field stimulations with physiological electric field strength (5 V/cm and 6 V/cm) can induce the alignment of ADSCs, but no cell alignment is found under conditions of less than 5 V/cm direct-current electric field, square wave, and biphasic pulse wave stimulation. The cellular viability is negatively correlated with the electric field intensity.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content