Objective To investigate the therapeutic effect of long PHILOS locking compression plate on the proximal humerus and humeral shaft fractures. Methods From March 2005 to December 2007, 35 cases with the proximal humerus and humeral shaft fractures were treated with long PHILOS locking compression plate, including 16 males and 19 females aged 29-68 years old (average 54.5 years old). There were 34 cases of fresh and close fracture, and the time from injury to operation was 3-9 days. One case had delayed union of fracture 5 months after receiving T-plates and internal fixation with steel plate. For the proximal humerus fracture, 7 cases had 2 parts of fracture, 19 had 3 parts of fracture, and 9 had 4 parts of fracture according to Neer classification; while for the humeral shaft fracture, 3 cases were classified as A1, 5 as A2, 10 as B1, 3 as B2, 6 as B3, 7 as C1 and 1 as C3 according to AO classification. Postoperatively, Neer scoring system was employed to evaluate the function of shoulder joint and HSS scoring system was adopted to evaluate the function of elbow joint. Results All incisions healed by first intension, and 30 cases were followed up for 12-33 months (average 18.2 months). Postoperatively, 2 cases had symptoms of radial nerve paralysis, which disappeared within 3 weeks; 1 case suffered from humeral head necrosis and received the secondary operation of humeral head replacement; humeral head was reduced evenly in 1 case, and 2 cases felt chronic sl ight pain in shoulder joints and received no further treatment. X-ray films showed 29 cases had fracture heal ing 6 months after operation, and all the patients had bone union 12 months after operation except 1 case receiving humeral head replacement. No such compl ications as screw lossening and internal fixation loosening occurred. By Neer scoring system, 6 cases were graded as excellent, 19 as good, 3 as fair, 2 as poor, and the excellent and good rate was 83.3%. By HSS scoring system, 16 cases were gradedas excellent, 14 as good, and the excellent and good rate was 100%. Conclusion Applying long PHILOS locking compression plate in the treatment of the proximal humerus and humeral shaft fractures provides a sol id fixation and high satisfactory rate with minor compl ications.
Objective To investigate the key parameters of three-dimensional anatomy of the proximal humerus and compare the differences between male and female, and between left and right sides in Chinese by volume rendering technique with multi-slice spiral CT (MSCT) so as to provide a reference for a new prosthesis of the proximal humerus which can adjust to the anatomical characteristics of Chinese. Methods A total of 100 healthy volunteers were collected from Chongqing of China, including 59 males and 41 females with an average age of 40.4 years (range, 21-57 years). The humeral retroversion angle (RA), neck-shaft angle (NSA), medial offset (MO), and posterior offset (PO) were measured by volume rendering technique with MSCT. The average values were compared between male and female and between left and right sides, the correlation of these parameters was also analysed. Results In 100 volunteers (200 sides), the RA was (19.9 ± 10.6)°, the NSA was (134.7 ± 3.8)°, the MO was (4.0 ± 1.1) mm, and the PO was (2.6 ± 1.3) mm. There were significant differences in RA and MO between left and right sides (Plt; 0.05); there was no significant difference in NSA and PO between left and right sides (P gt; 0.05). The PO and RA of both sides in male were significantly larger than those in female (P lt; 0.05); the NSA and MO in male were similar to those in female (P gt;0.05). PO was correlated positively with RA (r=0.617, P=0.000); MO was not correlated with NSA (r= —0.124, P=0.081). Conclusion Because of significant side differences in RA and MO, and significant gender differences in RA and PO, the differences should be considered in the design of new proximal humeral prosthesis and proximal humerus reconstruction.
Objective To compare the efficacy and indication of the three different surgical methods in the treatment of the senile osteoporotic comminuted proximal humerus fracture. Methods From January 2006 to April 2008, 70 senile patients with osteoporotic comminuted proximal humerus fracture were randomly divided into three groups to receive different surgical methods. There were 21 patients in the group A receiving Kirschner tension band or screw internal fixation, 37 patients in group B receiving internal fixation of locking proximal humeral plate, and 12 patients in group C receiving humeral head replacement. There were 36 males and 34 females aged 53-76 years old (average 61.9 years old). All the fractureswere closed, osteoporotic, and III and IV-part according to Neer classification. The disease course was 1-8 days (average 2.8 days). There was no significant difference among three groups in terms of basel ine information (P gt; 0.05). The effective antiosteoporosis therapy was given during perioperative period. Results All the incision healed by first intention. All patients reached anatomical or almost anatomical reduction without compl ications such as postoperative infection, neurovascular injury, and nonunion of bone. Seventy patients were followed up for 9-20 months (average 11.5 months). The heal ing time of the fracture was 8-12 weeks in group A and group B, the average heal ing time was 10.5 weeks in group A and 10 weeks in group B, and there was no significant difference between two groups (P gt; 0.05). Group C presented with no sign of prosthesis loosening or shoulder dislocation. Six cases in group A suffered from frozen shoulder, pain or acromion impingement syndrome 6 months after operation and obtained various degrees of improvement via functional exercises. One of them had humeral head avascular necrosis 12 months later and achieved fair recovery after performing humeral head replacement. Two cases in group B had frozen and painful shoulder 6 months after operation and achieved fair recovery after functional exercises. One cases in group C had frozen shoulder and poor performance of abduction and upl ifting and achieved improvement after exercises. The rest patients achieved satisfactory curative effects. The incidence of compl ication was 28.6% in group A, 5.4% in group B, and 8.3% in group C. The incidence of complication in group A was significantly higher than that of group B and group C (P lt; 0.05), and there was no significant difference between group B and group C (P gt; 0.05). Neer scale system was adopted to evaluate the postoperative shoulder function, the excellent and good rate was 66.7% in group A, 78.4% in group B, and 83.3% in group C. The excellent and good rate in group A was significantly less than that of group B and group C (P lt; 0.05), and there was no significant difference between group B and group C (P gt; 0.05). Conclusion The senile osteoporotic comminuted proximal humerus fracture treated by surgery can obtain satisfied results. Most patients can use locking plate fixation. Those with poor general condition can use Kirschner wire fixation with tension band or screws, but this method is subject to certain constraints. For some elder patients with humeral head necrosis and humeral head crushed, priority should be given to the use of humeral head replacement.
Objective To evaluate the effectiveness of locking plates for Neer 3- and 4-part proximal humerus fractures. Methods A retrospective analysis was made on the clinical data of 77 patients with 3- or 4-part proximal humerus fractures, who underwent open reduction and internal fixation of locking plates and were followed up more than 12 months between July 2008 and May 2011. There were 39 males and 38 females with an average age of 54.2 years (range, 18-81 years). Fractures were caused by falling in 47 cases, by traffic accident in 16 cases, by falling from height in 4 cases, by sporting in 5 cases, and by other reasons in 5 cases. The time between injury and operation was 2-16 days (mean, 4.5 days). According to Neer classification, there were 54 cases of 3-part fracture and 23 cases of 4-part fracture. The Constant scores, visual analogue score (VAS), and the complications were evaluated during follow-up. Results After operation, healing of incisions by first intention was obtained in 76 cases and healing by second intention in 1 case. All patients were followed up 12-36 months (mean, 18.5 months). At last follow-up, the Constant score was 71.1 ± 11.9; the results were excellent in 18 cases, good in 24 cases, fair in 25 cases, and poor in 10 cases with an excellent and good rate of 54.5%. The VAS score was 2.8 ± 2.2. Bone nonunion occurred in 2 cases; the other patients had bone union within 2-6 months (mean, 3.2 months). The complications occurred in 25 cases (32.5%). Revision surgery was performed in 15 patients (19.5%). Conclusion The treatment of Neer 3- and 4-part proximal humerus fractures remains challenging. Anatomic reduction, stable fixation, and reduced humeral head blood supply disruption may lead to a satisfactory outcome.
Objective To study the operative effect and complication of the prosthesis replacement of the proximal humerus with malignant tumor. Methods From October 1998 to August 2003, the prosthesis replacement was performed to treat the proximal femur with malignant tumor in 4 patients, including 2 patients with osteosarcoma (Enneking staging,ⅡA) and 2 patients with giancell tumor of the bone (ⅡA,ⅡB). By the International Society of Limb Salvage(ISOLS) criterion, the 2 cases of osteosarcoma were preoperatively scored as 4 and 5 points, and 2 cases of giant cell tumor of the bone were scored as 9 and 11 points. The patients’ psychological conditions as well as their limb pain, shape, locality, activity, and function werealso observed. Results The follow-up for 24-58 months (mean, 44 months) showed that there was no local recurrence or infection in all the patients except onepatient who had the loosening of the screws for the fixation 17 months after operation and had no treatment. After operation, all the patients had a better postoperative extention angle from 22° to 41°(mean, 25°), bending angle from 29° to 80°(mean, 35°), abduction angle from 5° to 28°, and circumgyrate angle from 15° to 22° in their shoulder joints. However, the shoulder joint function was still unstable to some extent and the joints had a decreased strength. By the criterion formulated by the ISOLS, the postoperative score for assessing the 2 patientswith osteosarcoma was increased by 16 points when compared with the preoperative score; the score for the 2 patients with giant cell tumor of the bone was increased by 9.5 points.Conclusion The prosthesis replacement to treat the malignant tumor of the proximal humerus is the good method of choice and has a good therapeutic result; however, there are more complications and so the method should be cautiously employed in the clinical practice.
ObjectiveTo analyze the effectiveness of proximal humeral internal locking system (Philos) plate for proximal humerus fracture. MethodsThirty-three patients with proximal humerus fracture were treated with open reduction and internal fixation with Philos plate between January 2009 and January 2014. There were 19 males and 14 females, aged 23-89 years (mean, 56.6 years). The left side was involved in 15 cases, and the right side in 18 cases. The injury causes included falling in 20 cases and traffic accident in 13 cases. All cases received X-ray and CT scan and three-dimensional reconstruction before operation. According to the Neer classification, 8 cases were rated as two-part fractures, 15 cases as three-part fractures, and 10 cases as four-part fractures. The interval time between injury and surgery was 1-7 days (mean, 3.67 days). Postoperative functional outcome was evaluated using the Constant-Murley score. ResultsInfection and liquefaction occurred in 2 cases respectively, which was cured after corresponding treatment; primary healing of wound was obtained in the other 29 cases. Five patients had shoulder pain. The patients were followed up 11-47 months (mean, 33 months). The mean time of fracture union was 7.5 months (range, 5-9 months) on the X-ray films. Humeral head necrosis occurred in 2 patients with Neer four-part fractures, and internal fixation failure occurred in 3 patients (2 screw broken and 1 plate broken) with four-part fractures (2 cases) and three-part fractures (1 case), which was cured after conservative treatment. At last follow-up, the mean Constant-Murley score was 70.5 (range, 42-90); the results were excellent in 3 cases, good in 21 cases, moderate in 6 cases, and poor in 3 cases. ConclusionSatisfactory results can be expected for proximal humeral fracture by using of the proximal humeral internal locking system plate based on strict indication and early rehabilitation training.
ObjectiveTo review the advancement made in the understanding of valgus impacted proximal humeral fracture (PHF). MethodsThe domestic and foreign literature about the valgus impacted PHF was extensively reviewed and the definition, classification, pathological features, and treatment of valgus impacted PHFs were summarized. Results PHF with a neck shaft angle ≥160° is recognized as a valgus impacted PHF characterized by the preservation of the medial epiphyseal region of the humeral head, which contributes to maintenance of the medial periosteum’s integrity after fracture and reduces the occurrence of avascular necrosis. Therefore, the valgus impacted PHF has a better prognosis when compared to other complex PHFs. The Neer classification designates it as a three- or four-part fracture, while the AO/Association for the Study of Internal Fixation (AO/ASIF) categorizes it as type C (C1.1). In the management of the valgus impacted PHF, the selection between conservative and surgical approaches is contingent upon the patient’s age and the extent of fracture displacement. While conservative treatment offers the advantage of being non-invasive, it is accompanied by limitations such as the inability to achieve anatomical reduction and the potential for multiple complications. Surgical treatment includes open reduction combined with steel wire or locking plate and/or non-absorbable suture, transosseous suture technology, and shoulder replacement. Surgeons must adopt personalized treatment strategies for each patient with a valgus impacted PHF. Minimally invasive surgery helps to preserve blood supply to the humeral head, mitigate the likelihood of avascular necrosis, and reduce postoperative complications of bone and soft tissue. For elderly patients with severe comminuted and displaced fractures, osteoporosis, and unsuitable internal fixation, shoulder joint replacement is the best treatment option. ConclusionCurrently, there has been some advancement in the classification, vascular supply, and management of valgus impacted PHF. Nevertheless, further research is imperative to assess the clinical safety, biomechanical stability, and indication of minimally invasive technology.
ObjectiveTo analyze the outcome and prognostic factors of using locking plate for treating proximal humerus fracture. MethodsBetween January 2005 and January 2012, 45 aged patients with a displaced 3-part or 4-part fracture of the proximal humerus were treated by locking plate. Range of motion and Constant-Mudey score were observed during the follow-up. ResultsForty-three patients were followed up from 12 to 48 months with an average of 18 months. The mean final Constant-Mudey score was 72.3±9.5 and 6 of them needed a second surgery. In addition to fracture type, other prognostic factors included redisplacement (4 cases, 9.3%), nonunion (3 cases, 7.0%), crashing (3 cases, 7.0%), necrosis of the humeral head (6 cases, 14.0%) and screw cut-out (5 cases, 11.6%). Among the patients with disrupted medial calcar, 4 needed a second surgery at the final follow-up, 3 had redisplacement, 2 had nonunion, and 2 had screw cut-out. ConclusionLocked screw-plates provide more secure fixation of fracture in aged patients, but the complication rate remains high. We suggest anatomic reduction, and plate and screws position, length of the screws, the medial cortical contact and stability may be the chief prognostic factors affecting the shoulder function following a proximal humeral fracture.
Objective To compare the effectiveness of simultaneous and delayed repair of combined full-thickness rotator cuff rupture in proximal humerus fracture. Methods Between January 2015 and January 2017, 44 patients with proximal humerus fractures complicated with full-thickness rotator cuff injuries were included. Twenty-four patients underwent open reduction and internal fixation (ORIF) and rotator cuff repair simultaneously (simultaneous operation group), and 20 patients underwent delayed arthroscopic rotator cuff repair more than 90 days after ORIF (delayed operation group). There was no significant difference in gender, age, cause of injury, and side of injury between the two groups (P>0.05). The fracture healing was observed by X-ray films. The shoulder function was assessed at 3, 6, and 12 months after operation by using the University of California at Los Angeles (UCLA) score. Results All incisions healed by first intention. All patients were followed up 12-24 months (mean, 17 months). Fractures all healed at 3 months after operation in simultaneous operation group. According to UCLA score, the patients had achieved significantly better outcomes in function, active forward flexion, strength of forward flexion, and subjective satisfaction in simultaneous operation group than in delayed operation group at 3, 6, and 12 months after operation (P<0.05). However, there was no significant difference in pain between the two groups (P>0.05). Conclusion For patients with proximal humerus fracture complicated with full-thickness rotator cuff rupture, performing ORIF and simultaneous repair of rotator cuff can improve shoulder function and achieve better effectiveness when compared with delayed repair of rotator cuff.
ObjectiveTo conduct a comprehensive analysis of proximal humeral anatomical characteristics in the Chinese population utilizing three-dimensional reconstruction technology, thereby establishing an evidence base for the enhancement of shoulder hemiarthroplasty procedures and the development of domestically manufactured prostheses. Methods The study cohort comprised 30 patients (60 shoulders) presenting with cervicoscapular pain between July 2023 and June 2025, with equal gender distribution (15 males and 15 females); age distribution ranged from 20 to 75 years (mean, 53.7 years). Data acquisition was performed via high-resolution CT imaging (technical parameters: slice thickness 0.625 mm, voltage 120 kV, current 150 mA, matrix 512×512). Subsequently, CT datasets were processed in DICOM format using Mimics17.0 software for three-dimensional reconstruction, followed by quantitative assessment via Imageware12.0 software to evaluate key proximal humeral parameters: humeral head dimensions (coronal diameter, sagittal diameter, surface curvature diameter, thickness), angular measurements [neck-shaft angle, retroversion angle (retroversion angle 1 was the angle between the humeral head axis and the line connecting the medial and lateral condyles, and retroversion angle 2 was the angle between the humeral head axis and the tangent of the trochlea)], and positional metrics (medial offset, posterior offset). Statistical analysis incorporated Pearson correlation coefficients to determine parameter relationships, with comparative evaluations conducted across demographic variables including gender, height, body mass, and age. Results Quantitative analysis yielded the following measurements: humeral head coronal diameter (41.8±3.6) mm, sagittal diameter (39.1±4.1) mm, surface curvature diameter (44.9±4.6) mm, thickness (17.2±1.8) mm, neck-shaft angle (128.4±4.2)°, retroversion angle 1 (16.9±8.9)°, retroversion angle 2 (21.4±11.3)°, medial offset (3.8±1.7) mm, and posterior offset (5.1±1.6) mm. Correlation analysis demonstrated the most pronounced positive relationship between humeral head surface curvature diameter and thickness (r=0.966), with additional significant positive correlations observed between surface curvature diameter and coronal diameter (r=0.842), posterior offset and retroversion angle (r=0.766), and coronal diameter and thickness (r=0.727). Demographic analysis revealed significantly greater dimensions in males compared to females for humeral head surface curvature diameter, coronal diameter, sagittal diameter, and thickness (P<0.05), with these parameters demonstrating progressive increases corresponding to height (P<0.05). With the exception of neck-shaft angle, all parameters exhibited a positive correlation with body mass. No significant age-related differences were detected across parameters (P>0.05). Conclusion The proximal humeral morphology in the Chinese population exhibits substantial variability, necessitating optimization of prosthetic designs based on population-specific anatomical metrics to enhance the efficacy of personalized clinical interventions.