Objective To review the biomechanics of internal fixators for proximal humeral fractures, and to compare the mechanical stabil ity of various internal fixators. Methods The l iterature concerning the biomechanics of internal fixators for proximal humeral fractures was extensively analyzed. Results The most important things for best shoulder functional results are optimal anatomical reduction and stable fixation. At present, there are a lot of methods to treat proximal humeral fractures. Locking-plate exhibites significant mechanical stabil ity and has many advantages over other internal fixators by biomechanical comparison. Conclusion Locking-plate has better fixation stabil ity than other internal fixators and is the first choice to treat proximal humeral fractures.
Because of the complexity of proximal humeral fractures, the treatment of proximal humeral fractures has always been a challenge for clinicians. The MultiLoc intramedullary nail is a new type of internal fixation device which has been gradually used in the treatment of proximal humeral fractures in recent years. At present, it is mainly used in the Neer two- and three-part fractures, especially surgical neck fractures. Its flexible design can provide personalized and multi-plane fixation for fracture patients, “screw-in-screw” and medial supporting screw can effectively reduce the axial displacement and varus angle of humeral head, and minimally invasive surgical incision can reduce the injury of rotator cuff. This review focuses on the research status and related evidence of the design, operation, prognosis, and postoperative complications of MultiLoc intramedullary nail, in order to provide a theoretical basis for the application of MultiLoc intramedullary nail in fracture treatment, and enhance clinicians’ understanding of MultiLoc intramedullary nail as a new type of internal fixation device.
Objective To evaluate the cl inical and radiological outcomes of minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) in the treatment of proximal humeral shaft fracture. Methods From July 2004 to April 2008, 26 patients with displaced fractures of the proximal humeral shaft were recruited, including 8 males and 18 females. Age of patients averaged 66 years old (range, 34-82 years old). According to AO classification, there were 4 cases of type A1, 2 cases of type A2, 8 cases of type B1, 4 cases of type B2, 2 cases of type B3, 4 cases of type C1 and 2 cases of type C2. The time from injury to surgery averaged 2 days (range, 1-5 days). There were 8 osteoporotic fractures. Results All surgical wound healed primarily, and there was no wound infection. Three patients had postoperative radial nerve neurapraxia, which recovered at 4, 6, 8 months respectively. All patients were followed up for 6-24 months with an average of 14.1 months. Radiological examination revealed bony union within 6 months in 25 cases. There was 1 delayed union which remained asymptomatic and eventually healed at 8 months with acceptable Constant-Murley score. There were 3 cases of shoulder impingement syndrome diagnosed at 3 months post-operatively. After implant removal, they all achieved an acceptable Constant-Murley score. According to Constant-Murley scoring system, there were 11 excellent, 10 good and 5 acceptable results. The excellent or good rate was 80.8%. Conclusion MIPO technique using LCP is an effective method to treat proximal humeral shaft fractures, which facil itates functional recovery of the shoulder joint. During the surgery, it is important to achieve a good fracture reduction and to avoid compl ications.
Objective To compare the effectiveness of locking plate and intramedullary nail in treatment of Neer two- and three-part fractures of the proximal humerus in the elderly. Methods A retrospective analysis was conducted on 86 elderly patients with Neer two- and three-part fractures of the proximal humerus met the selection criteria between January 2015 and December 2018. Forty-six patients were treated with locking plate fixation (locking plate group), and 40 patients with intramedullary nail fixation (intramedullary nail group). There was no significant difference in gender, age, cause of injury, fracture side and type, time from injury to operation, and comorbidities between the two groups (P>0.05). Visual analogue scale (VAS) score, American Shoulder and Elbow Surgery (ASES) score, Constant-Murley score, and shoulder range of motion (forward flexion, abduction, and external rotation) were compared between the two groups. X-ray films were taken to assess the fracture healing, and the neck-shaft angle was measured at 2 days after operation and at last follow-up, and the difference between the two time points was calculated. Results Patients in both groups were followed up 18-40 months, with an average of 30.4 months. There was no significant difference in follow-up time between the two groups (t=−0.986, P=0.327). X-ray films reexamination showed that the fractures of two groups healed, and the healing time was (11.3±2.1) weeks in locking plate group and (10.3±2.0) weeks in intramedullary nail group, which had significant difference between the two groups (t=2.250, P=0.027). The difference of neck-shaft angle was (7.63±7.01)° in locking plate group and (2.85±2.82)° in intramedullary nail group, which had significant difference between the two groups (t=4.032, P<0.001). There was no significant difference in Constant-Murley score, ASES score, VAS score, and shoulder range of motion between the two groups at last follow-up (P>0.05). Complications occurred in 13 cases (28.3%) of locking plate group and in 4 cases (10.0%) of intramedullary nail group, and the difference between the two groups was significant (χ2=4.498, P=0.034). Conclusion Both locking plates and intramedullary nails can be used for the treatment of Neer two- and three-part fractures of the proximal humerus in the elderly. The intramedullary nail fixation surgery is more minimally invasive, which has fewer postoperative complications and faster fracture healing.
Open reduction and internal fixation with plate and screw is one of the most widely used surgical methods in the treatment of proximal humeral fractures in the elderly. In recent years, more and more studies have shown that it is very important to strengthen the medial column support of the proximal humerus during the surgery. At present, orthopedists often use bone graft, bone cement, medial support screw and medial support plate to strengthen the support of the medial column of the proximal humerus when applying open reduction and internal fixation with plate and screw to treat proximal humeral fractures. Therefore, the methods of strengthening medial column support for proximal humerus fractures and their effects on maintaining fracture reduction, reducing postoperative complications and improving functional activities of shoulder joints after operation are reviewed in this paper. It aims to provide a certain reference for the individualized selection of medial support methods according to the fracture situation in the treatment of proximal humeral fractures.
ObjectiveTo investigate the clinical results of locking-plate with an intramedullary fibular allograft for type C2 proximal humeral fracture fixation. MethodsBetween January 2011 and August 2012, 16 patients with proximal humeral fractures (AO type C2) were treated by locking-plate with an intramedullary fibular allograft. The clinical data were retrospectively analysed. There were 5 males and 11 females with an average age of 64 years (range, 55-70 years). The injury causes were falling injury in 12 cases, traffic accident injury in 3 cases, and sports injury in 1 case. The duration between injury and operation ranged from 2 to 6 days (mean, 4.5 days). The imaging data were used to judge the fracture healing, and to measure the neck-shaft angle and the height of humeral head; the disability of arm, shoulder, and hand (DASH) score, short-form 36 health survey scale (SF-36), and Neer score were used to evaluate the function of the shoulder after surgery. ResultsPrimary healing of incision was obtained in all patients; no complication of vascular and nerve injury occurred. Sixteen cases were followed up 12-24 months (mean, 18 months). All fractures healed at 18-24 weeks (mean, 20 weeks). No complication occurred as follows:re-displacement, necrosis, rejection reaction, and loosening or extraction of screws. At last follow-up, the neck-shaft angle was 126.6-136.9° (mean, 132.5°), showing a little lost when compared with intraoperative angle (130.5-138.0°, 134.0° on average). At 12 months after surgery, the height loss of humeral head was 1.8-4.6 mm (mean, 2.0 mm); the passive anteflexion of the shoulder was 130-160° (mean, 148°); the active anteflexion was 120-145° (mean, 136°); the external rotation was 30-65° (mean, 56°); the internal rotation was 15-25° (mean, 19°). And the DASH score was 2-53 (mean, 12); the SF-36 score was 50-95 (mean, 89). According to Neer score for shoulder function, the results were excellent in 10 cases, good in 4 cases, fair in 1 case, and poor in 1 case, with an excellent and good rate of 87.5%. ConclusionLocking-plate with an intramedullary fibular allograft for type C2 proximal humeral fracture fixation has satisfactory clinical results because of stable fixation, high clinical outcome scores, and low internal fixation failure.
Objective To compare the effectiveness between operative and non-operative treatment for 3- and 4-part proximal humeral fractures in elderly patients. Methods Between January 2009 and January 2011, 35 patients with 3- or 4-part proximal humeral fractures were treated with open reduction and locking plate internal fixation (n=20, operative group) and with closed reduction and splint or cast fixation (n=15, non-operative group). There was no significant difference in gender, age, etiology, fracture type, and disease duration between 2 groups (P gt; 0.05). The postoperative rehabilitation protocol was performed in 2 groups. Results All patients of the operative group achieved healing of incision by first intention. All patients were followed up 16 months on average (range, 12-20 months). The X-ray films showed that the other fractures healed except 1 case (5.0%) nonunion in operative group. Varus malunion was found in 1 case (6.7%) of non-operative group and 2 cases (10.0%) of operative group. Humeral head necrosis was found in 1 case respectively in 2 groups (5.0% and 6.7%). There was no significant difference in complication incidence between 2 groups (P gt; 0.05). The Constant-Murley scores of non-operative group and operative group were 64.7 ± 9.9 and 66.8 ± 11.8 at last follow-up respectively, showing no significant difference (t=0.59, P=0.47). Conclusion Operative treatment has similar effectiveness to non-operative treatment for 3- and 4-part proximal humeral fractures. In elderly patients, non-operative treatment should be chosen.
ObjectiveTo investigate the effectiveness of limited open reduction via “door-shaft method” and internal fixation with locking plate for two- and three-part fractures of the proximal humerus.MethodsThe clinical data of 64 patients with proximal humeral fractures who were admitted between January 2013 and December 2016 and met the selection criteria were retrospectively analyzed. There were 23 males and 41 females, with an average age of 68.0 years (range, 50-89 years). The injuries were caused by falling in 57 cases, traffic accident in 5 cases, and falling from height in 2 cases. The interval between injury and operation was 1-7 days (mean, 2.1 days). According to Neer classification, there were 28 cases of two-part fractures and 36 cases of three-part fractures. According to the angulation direction of the proximal humeral neck shaft angle, there were 21 cases of adduction fractures and 43 cases of abduction fractures. The fractures were treated with limited open reduction via “door-shaft method” and proximal humerus internal locking systems for internal fixation. The operation time, intraoperative blood loss, number of fluoroscopy, hospital stay, and complications were recorded. The fracture healing was reviewed by X-ray film and the healing time was recorded. The shoulder joint function was evaluated by Neer score standard.ResultsThe operation time was 45-127 minutes, with an average of 82.3 minutes. The intraoperative blood loss was 30-125 mL, with an average of 62.7 mL. Intraoperative fluoroscopy was performed 30-69 times, with an average of 37.0 times. The hospital stay was 6-23 days, with an average of 10.3 days. All incisions healed by first intention. All patients were followed up 12-37 months, with an average of 18.3 months. X-ray film re-examination showed that all fractures healed, the healing time was 12-21 weeks, with an average of 14.3 weeks. After operation, 3 cases had shoulder stiffness and 1 case had fracture malunion. At last follow-up, the Neer score of shoulder joint function was 49-97, with an average of 83.1. Among them, 38 cases were excellent, 13 cases were good, 10 cases were fair, and 3 cases were poor. The excellent and good rate was 79.7%. The excellent and good rate of patients with two-part fractures was 82.1% (23/28), and the excellent and good rate of patients with three-part fractures was 77.8% (28/36).ConclusionThe “door-shaft method” not only reduces the difficulty of the Joystick technique in the reduction of proximal humerus fractures, but also provides auxiliary stability. It is used for limited open reduction and internal fixation with locking plate to treat the two- and three-part fractures of the proximal humerus, which can achieve good effectiveness.
ObjectiveTo observe the influence of different humeral neck-shaft angle on the efficacy in the treatment of proximal humeral fractures with locking plate. MethodsA total of 106 patients with proximal humeral fractures were treated by locking plate between March 2009 and March 2013, and the clinical data were retrospectively analyzed. Of 106 cases, 58 were male and 48 were female, aged from 26 to 71 years (mean, 52.3 years). The causes were traffic accident injury in 54 cases, falling injury from height in 23 cases, falling injury in 21 cases, and others in 8 cases. According to the Neer classification, there were 32 cases of two-part fractures, 65 cases of three-part fractures, and 9 cases of four-part fractures. The time from injury to operation was 1-7 days (mean, 2.7 days). According to neck-shaft angle by X-ray measurements at 1-3 days after operation, the patients were divided into 3 groups:valgus group (>145°), normal group (126-145°), and varus group (<126°) to observe the influence of neck-shaft angle on efficacy. ResultsAccording to postoperative humeral neck-shaft angle, there were 10 cases in valgus group, 75 cases in normal group, and 21 cases in varus group. There was no significant difference in general clinical data among 3 groups (P>0.05). The patients were followed up 6-12 months. The X-ray results showed fracture healing, and no significant difference was found in fracture healing time among 3 groups (P>0.05). After 6 months, the varus angle of femoral head and visual analogue scale (VAS) score of normal group were significantly lower than those of valgus group and varus group (P<0.05). The excellent and good rate of Constant-Murley score was 78.67% (59/75) in normal group, and it was significantly higher than that in valgus group (60.00%, 6/10) and varus group (42.86%, 9/21) (P<0.05), but there was no significant difference between valgus group and varus group (P>0.05). The complication rate was 28.57% (6/21) in varus group, was 10.67% (8/75) in normal group, and was 20.00% (2/10) in valgus group, showing no significant difference among 3 groups (χ2=4.31, P=0.12). ConclusionReconstruction of normal neck-shaft angle is the key to good shoulder function and clinical efficacy in the treatment of proximal humeral fracture.
ObjectiveTo evaluate the effectiveness of titanium elastic nails for severe displaced proximal humeral fractures in older children. MethodsBetween April 2009 and July 2012, 31 cases of severe displaced proximal humeral fractures were treated with closed or open reduction and fixation with 2 titanium elastic nails, and the clinical data were retrospectively analyzed. There were 23 boys and 8 girls, aged from 10 to 15 years (mean, 12.8 years). The causes of injury were sports injury (16 cases), traffic accident (11 cases), and falling from height (4 cases). The interval from injury to operation was 6 hours to 7 days (mean, 72 hours). According to Neer-Horwitz classification, 17 cases were rated as type III fracture and 14 cases as type IV fracture. There were 21 cases of metaphyseal fractures and 10 cases of epiphyseal fractures. ResultsSatisfactory reduction of fracture and stable fixation were obtained in all patients (closed reduction in 23 cases and open reduction in 8 cases). Primary healing was achieved in all incisions; no infection and neurovascular injury occurred. All patients were followed up 12-36 months with an average of 20 months. X-ray films showed that all fractures healed at 7-10 weeks (mean, 8 weeks). During follow-up, no disturbance of development or angulation deformity caused by premature physeal closure or bone bridge formation was observed. At last follow-up, the average Neer score of the shoulder was 95.7 (range, 83-100). The appearance and motion of the shoulder were normal. There was no significant difference in the upper extremity length between affected side and contralateral side[(67.68±2.56) cm vs. (67.61±2.54) cm; t=-1.867,P=0.072]. ConclusionTitanium elastic nails for severe displaced humeral fractures in older children is a safe and effective method with a low complication incidence.