ObjectiveTo evaluate the clinical value of multi-slice CT in the diagnosis of complications due to breast augmentation. MethodsWe collected the imaging data of 32 female patients who accepted multi-slice CT examination in the second People's Hospital of Chengdu after breast augmentation between February 2010 and February 2015. The position, shape, edge, internal density, leakage, rupture and hard nodules of the prosthesis were observed and analyzed carefully. ResultsIn the 32 patients with breast augmentation, 12 were normal with bilateral symmetry and without abnormal shape or density. Among the other 20 patients, 11 had capsular contracture, 5 had prosthesis leakage, rupture and hard nodules, 4 had breast infection, 1 had fibroadenoma, 1 had cystoma, and 5 had little calcified nodules in the breast tissue. ConclusionThe multi-slice CT scan can clearly and accurately show the position, shape and size of the breast prosthesis as well as the existence of leakage, rupture and hard nodules in the prosthesis. It plays a very important role in the diagnosis of the complications due to breast augmentation and can be effective guidance for clinical operation.
OBJECTIVE To review the history and current status of total wrist arthroplasty. METHODS The original articles about wrist arthroplasty in recent years were reviewed. RESULTS The properties of wrist prosthesis of different generations were reviewed, with the emphasis on the prosthesis design and biomechanical behaviours. The surgical techniques, complications and salvage procedures were also discussed. CONCLUSION Although wrist arthrodesis is highly successful in treating the end-stage wrist arthritis, total wrist arthroplasty using well-designed prosthesis remains an alternative for the patients with special demands of hand functions.
Objective To evaluate the clinical effect of Easy Prosthesis D-10 on open preperitoneal groin tension-free hernioplasty. Methods The operative time, operation-correlated complications, hospital stay and recent follow-up findings of 63 patients underwent preperitoneal groin tension-free hernioplasty were analyzed from October 2006 to April 2008. Results No case died in perioperative period. The average operative time was (47.6±10.5) minutes. None of incision infection and scrotal hydrocele occurred. The average hospital stay was (7.7±2.1) days. During follow-up period of 6 to 24 months, no recurrence, chronic pain and foreign body sensation were found. Conclusion The open preperioneal groin tension-free hernioplasty by Easy Prosthesis D-10 is safe and reliable, especially for the inguinal hernia with large hernia ring or defect of transversalis fascia and recurrent hernia.
After freatment of prosthesis replacement for 12 malignant tumer of the proximal humoral werereported. The operation were performed after the indications and methods of treatment had beendefined. All of the 12 cases were followed-up, in the average of 8 yeare. On functional evaluation , 8cases had satisfactory result , but per in 1 cases and 3 cases died from recurrence or metastasis withinfive years. The indieation of the procthetic replantation, the complications, and revision weredisecused.
Objective To study the effect of all-coated long stem prosthesis associated with allograft in revision total hip replacement (THR). Methods From January 1997 to January 2004, 20 patients with non-infectious loosened implant after primary THR were treated. There were 12 males and 8 females with a mean age of 65 years (58-77 years). The average period between primary THR and revision THR was 12 years (3-18 years). According to classification of Paprosky, there were10 cases of type II, 6 cases of type IIIA, 3 cases of type IIIB and 1 case of type IV. All-coated long stem prosthesis was used in all cases. Impacting bone grafting was done in 12 cases and impacting bone grafting associated with cortical strut grafting in 8 cases. The mean amount of morsel ized bone was 20 g (5-35 g), the length of cortical bone was 10-22 cm. Results All the incisions got heal ing by first intension. All patients were followed up for an average period of 36 months (16-48 months). Dislocation occurred at 5 days after operation and was cured with closed reduction and traction in 1 case. There was significant difference (P lt; 0.05) in the mean Harris score between preoperation (50.0 ± 2.3) and postoperation (90.0 ± 2.5). The X-ray checking showed that continuous radiolucent l ine of 3 mm occurred in 1 case, prosthesis subsidence of 5 mm and 7 mm in 2 cases and that no bone absorption was observed. Seven cases of cortical bone grafting union was achieved within 3 years except 1 case of cortical bone un-union. Conclusion It can obtained the initial stabil ization of prosthesis to use all-coated long stem prosthesis associated with allograft in revision THR to treat femur bone defect after THR. The short-term effects of the cl inical and X-ray checking are satisfactory, but future effect is to be observed.
OBJECTIVE There are various methods used to treat the Kienbock’s disease with various outcomes. This study investigated the effect of combining acrylic lunate prosthesis replacement with resection of articular branches to wrist from anterior and dorsal interosseous nerve. METHODS From January 1992 to January 1997, six cases were included. All of the patients were in stage III according to Lichtman’s classification. Besides replacement of the acrylic lunate prosthesis, segment of the pure sensory branches from anterior and posterior interosseous nerves were resected. RESULTS Follow-up for 10 to 54 months (an average of 32 months) the pain was relieved in all patients except one. The range of movement of wrists were as followings: The extension of the wrist was 20 to 35 degrees (an average of 26 degrees) and flexion was 20 to 35 degrees (an average of 32 degrees). There was no improvement in radial and ulnar deviation. CONCLUSION Lunate prosthesis replacement combined with resection of articular branches to wrist resulted in a painless wrist and was a satisfactory method.
Objective To study the operative effect and complication of the prosthesis replacement of the proximal humerus with malignant tumor. Methods From October 1998 to August 2003, the prosthesis replacement was performed to treat the proximal femur with malignant tumor in 4 patients, including 2 patients with osteosarcoma (Enneking staging,ⅡA) and 2 patients with giancell tumor of the bone (ⅡA,ⅡB). By the International Society of Limb Salvage(ISOLS) criterion, the 2 cases of osteosarcoma were preoperatively scored as 4 and 5 points, and 2 cases of giant cell tumor of the bone were scored as 9 and 11 points. The patients’ psychological conditions as well as their limb pain, shape, locality, activity, and function werealso observed. Results The follow-up for 24-58 months (mean, 44 months) showed that there was no local recurrence or infection in all the patients except onepatient who had the loosening of the screws for the fixation 17 months after operation and had no treatment. After operation, all the patients had a better postoperative extention angle from 22° to 41°(mean, 25°), bending angle from 29° to 80°(mean, 35°), abduction angle from 5° to 28°, and circumgyrate angle from 15° to 22° in their shoulder joints. However, the shoulder joint function was still unstable to some extent and the joints had a decreased strength. By the criterion formulated by the ISOLS, the postoperative score for assessing the 2 patientswith osteosarcoma was increased by 16 points when compared with the preoperative score; the score for the 2 patients with giant cell tumor of the bone was increased by 9.5 points.Conclusion The prosthesis replacement to treat the malignant tumor of the proximal humerus is the good method of choice and has a good therapeutic result; however, there are more complications and so the method should be cautiously employed in the clinical practice.
ObjectiveTo explore the association between wearing dentures and the risk of head and neck cancer using meta-analysis. MethodsPubMed, EMbase, CNKI, and WanFang Data were searched up to April 30th, 2014, for cohort studies and case-control studies about the association between wearing dentures and the risk of head and neck cancer. Literature screening according to the inclusion and exclusion criteria, data extraction and methodological quality assessment of included studies were completed by two reviewers independently. Then meta-analysis was conducted using Comprehensive Meta-Analysis v 2.2 software. ResultsEight case-control studies in 7 reports were finally included. The results of meta-analysis revealed that, low-degree association existed between wearing dentures and the risk of head and neck cancer (OR=1.08, 95%CI 1.00 to 1.16); and the results of further subgroup analysis (according to gender, cancer lesions, confounders adjustment, and publication years) also showed no significant difference. ConclusionWearing dentures is not significantly associated with the risk of head and neck cancer (no difference regarding gender or cancer lesions). Due to limitations of this meta-analysis, high-quality studies with large sample size are needed to further verify the above conclusion.
Objective To introduce the occurrence mechanisms, prevention, and treatment measures of prosthetic aseptic loosening. Methods The recent original articles about prosthetic aseptic loosening were extensively reviewed and analyzed. Results Prosthetic aseptic loosening was a very complex process involving many mechanical and biological aspects. The main mechanical factors included prosthetic materials, shapes and sizes, implant fixation methods (including surfacetreatments), cl inical installation, interface micromotion, stress shielding, implant wear, interface integrity, and peri prosthetic high hydraulic pressure, etc.; the main biological factors included the types and sizes of wear particles, cell-activated responses, cytokine release, enzyme activation and allergic reactions to wear particles, etc.. Many measures should be adopted to effectively prevent and treat it, including improving materials and designs of prostheses, fixation techniques, surgical techniques, and drug treatments. Conclusion Prosthetic aseptic loosening is still a troublesome compl ication after joint replacements in orthopaedics, and more attention should be paid for its effective prevention and treatment.
Objective To study the clinical feasibility of the prosthetic composites of the intercalary allograft and the segmental allograft in reconstruction of the skeletal defect after the limb tumor resection. Methods Between August 1999 and December 2003, 28 patients with skeletal defects after the limb tumor resection were treated with the intercalary allograft or the segmental allograft megaprosthesis composite for reconstruction of skeletal defects. The bone involvements were observed in 16 patients with osteosarcoma, 4 patients with parosteal osteosarcoma, 5 patients with Ewing sarcoma, and 3 patients with soft tissuesarcoma. Preoperative biopsy was performed on all the patients, and the pathological result was confirmed after surgery. According to the Enneking system, 5 patients were grouped in ⅠB and 23 patients in ⅡB. The patients with osteosarcomaor Ewing sarcoma received the standard chemotherapy before and after operation.Eighteen and ten patients received the segmental allograft prosthetic compositereplacement and the intercalary allograft with the interlocking intramedullary nail fixation, respectively. The functional outcome was evaluated by the MSTS score. Results According to the follow-up for 5-48 months (average, 24 months), local recurrence was observed in 1 patient who underwent amputation eventually. Of the 28 patients, 3 developed nonunion of the allografthost junction accompanied by severe resorption and 2 developed deep infection. No allograft fracture was seen in the patients. Most of the patients achieved a good functional result with an average MSTS score of 23.4. ConclusionThe prosthetic composite replacement of the intercalary allograft and the segamental allograft can be used n the skeletal defect reconstruction after the limb tumor resection. The stablecontact in the allografthost junction and the b intramedullary internal fixation can help to reduce the complication rate of the allograft.