OBJECTIVE To review the physiological function of sodium hyaluronate in joints and its clinical applications. METHODS Many literatures were reviewed and analysed on therapeutic mechanism and the application foreground of sodium hyaluronate. RESULTS Extrinsic sodium hyaluronate plays an important role in improving synovial fluid and protecting cartilages as well as suppressing inflammation, so it is used in the treatment of joint diseases such as knee osteoarthritis, rheumatoid arthritis or temporomandibular osteoarthritis. CONCLUSION Sodium hyaluronate possesses a good applied prospect in joint diseases.
Objective To study the biological characteristic and potential of chondrocytes grafting cultured on fascia in repairing large defect of articular cartilage in rabbits. Methods Chondrocytes of young rabbits were isolated and subcultured on fascia. The large defect of articular cartilage was repaired by grafts of freeze-preserved and fresh chondrocytes cultured on fascia, and free chondrocytes respectively; the biological characteristic and metabolism were evaluated bymacroscopic, histological and immunohistochemical observations, autoradiography method and the measurement of nitric oxide content 6, 12, 24 weeks after grafting. Results The chondrocytes cultured on fascia maintained normal growth feature and metabolism, and there was no damage to chondrocytes after cryopreservation; the repaired cartilage was similar to the normal cartilage in cellular morphology and biological characteristics. Conclusion Chondrocytes could be cultured normally on fascia, which could be used as an ideal carrier of chondrocytes.
Objective To discuss the clinical application of preserving femoral neck in total hip arthroplasty and to analyze the early stage results.Methods From January 1999 to June 2001, 12 patients underwent total hip arthroplasty with preservation of femoral neck. We cut off the femoral head in infra-head position with improved Moore micro-incisions to reserve intact neck of femur. Thensuitable size of extra cup was selected and placed at 55° eversion angle. The internal cup, made from ultra high polymer poly thene and with ultra radius design, was placed at 45°eversion angle. Harris scores were recorded before operation, after operation and during the follow-up. During the follow-up, the X-rayfilms were taken to assess position, loosening of the prosthesis and ectopic ossification.Results All 12 patients were followed up 2-4.5years with an average of 3.1 years. The mean Harris score of hip elevated from 54 scores before operation to 92 scores of the last follow-up. Mild ectopic ossification occurred in 3 cases. There was no prosthesis loosening and femoral prosthesis setting, and only onepatient had mild bone absorption around femoral prosthesis.Conclusion Total hip arthroplasty with femoral neck preservation is a good option for the patients who need total hip arthroplasty for variable reasons, which is indicated for the patients whose femoral neck is intact with no osteoporosis.
ObjectiveTo investigate the cl inical characteristics, diagnosis, and treatment of metacarpophalangeal (MCP) joint locking with extension lag. MethodsBetween February 2009 and April 2014, 17 patients (17 fingers) with MCP joint locking with extension lag were treated. The patients included 4 males and 13 females, and the average age was 40.7 years (range, 20-72 years). The index finger was locked in 12 cases and the middle finger in 5 cases. All patients could not fully extend the MCP joint at about 30° flexion without flexion limitation of the interphalangeal joint. The range of motion (ROM) of the MCP joint was (41.2±5.1)°. The visual analogue scale (VAS) score was 2.7±0.5. X-ray and CT scanning showed that there was a bony prominence on radial condyle of the metacarpal head in 15 primary patients, and a hook like osteophyte on ulnar condyle in 2 degenerative patients. All patients were treated with close reduction first, and open reduction was conducted when the manipulation failed. ResultsSuccessful close reduction was achieved in 5 cases, and successful open reduction in 8 cases; 4 cases gave up treatment after failure for close reduction. All patients who achieved successful reduction were followed up 2.3 years on average (range, 6 months to 5 years and 2 months). The ROM of the MCP joint was increased to (80.4±6.6)° at last follow-up, showing significant difference when compared with ROM before reduction (t=-19.46, P=0.00). The VAS score decreased to 0.2±0.4 at last follow-up, also showing significant difference when compared with score before reduction (t=13.44, P=0.00). ConclusionAccessory collateral ligament caught at the bony prominence on the radial condyle of the metacarpal head is the most common cause of the MCP joint locking with extension lag. Close reduction is feasible, but recurrence of locking is possible. Surgical treatment is advised in the event of manipulation failure or recurrent locking.
ObjectiveTo introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. MethodsBetween July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P>0.05). The operation time, intraoperative blood loss, incision length, incision heal ing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. ResultsThe intraoperative blood loss in trial group was significantly less than that in control group (P<0.05). The incision length in trial group was significantly shorter than that in control group (P<0.05). Difference was not significant in operation time and the rate of incision heal ing between 2 groups (P>0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture heal ing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P>0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). ConclusionIt can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for tibial plateau fracture. Traction of joint capsule is helpful in the reduction and good recovery of joint surface collapse. In addition, the surgery without opening joint capsule can avoid joint stiffness and obtain better joint function.
Objective To evaluate the clinical valueof the revision of total hip replacement(THR), to analyse the reason of the rev isions, and to discuss the main difficulties and measures to manage it.Methods From June 1998 to January 2002, 15 cases (15 hips) were revised on totalhip replacement. The reasons for revision in the cases were as follows:failure of primary operative techenique, loosening and sinking of the components, displacement of the prosthesis, erosion of the acetabulum, as well as fracture of the femoral stem. The main difficulties of the revision were:poor health condition of the patients; the remove of the prosthesis of the primary THR,especially the broken femoral stem and the cements; the loss of localbone. The measures to remove the broken femoral stem were described.ResultsAll cases were followed up 2.4 years on average: 2 patients died from heart disease and cerebrovascular disease respectively, while the good results were achieved in the others.No infection, dislocation, loosening, and other complications occurred. The good effects were related with following factors:mild degree of illness; no severe bone defect; most of the first femoral head replacement.Conclusion The revision of THRis a more difficult operation, so that the special instrument and equipment andoperative experience are required.
Objective To investigate the development and appl ication of the computer aided surgery systems in the joint surgery field. Methods The l iteratures were extensively reviewed to analysis the usefulness of current active, semi-active and passive computer aided surgery systems in solving the cl inical problems of joint surgery. Results Several computer aided surgery systems have met the high technique demands, such as the precision of anatomical position and orientation, the accuracy of normal l imb al ignment restoration, the optimum of instrumentation control in arthroplasty, peri-articular osteotomy and minimally invasive procedure. Conclusion Computer aided joint surgery systems facil itate precise surgical techniques to achieve ideal operative outcome.
The surgical installation accuracy of the components in unicompartmental knee arthroplasty (UKA) is an important factor affecting the joint function and the implant life. Taking the ratio of the medial-lateral position of the femoral component relative to the tibial insert (a/A) as a parameter, and considering nine installation conditions of the femoral component, this study established the musculoskeletal multibody dynamics models of UKA to simulate the patients’ walking gait, and investigated the influences of the medial-lateral installation positions of the femoral component in UKA on the contact force, joint motion and ligament force of the knee joint. The results showed that, with the increase of a/A ratio, the medial contact force of the UKA implant was decreased and the lateral contact force of the cartilage was increased; the varus rotation, external rotation and posterior translation of the knee joint were increased; and the anterior cruciate ligament force, posterior cruciate ligament force and medial collateral ligament force were decreased. The medial-lateral installation positions of the femoral component in UKA had little effect on knee flexion-extension movement and lateral collateral ligament force. When the a/A ratio was less than or equalled to 0.375, the femoral component collided with the tibia. In order to prevent the overload on the medial implant and lateral cartilage, the excessive ligament force, and the collision between the femoral component and the tibia, it is suggested that the a/A ratio should be controlled within the range of 0.427−0.688 when the femoral component is installed in UKA. This study provides a reference for the accurate installation of the femoral component in UKA.
ObjectiveTo evaluate the middle- and long-term effectiveness of primary total hip arthroplasty (THA) in patients with chronic autoimmune inflammatory diseases. MethodsBetween January 1990 and June 2006, 42 patients (51 hips) with chronic autoimmune inflammatory diseases underwent THA. There were 15 males (18 hips) and 27 females (33 hips) with an average age of 36.9 years (range, 22-70 years). The locations were the left side in 29 hips and the right side in 22 hips. Of 42 cases, there were 11 cases of systemic lupus erythematosus (13 hips), 16 cases of rheumatoid arthritis (22 hips), and 15 cases of ankylosing spondylitis (16 hips). The causes of THA included avascular necrosis of the femoral head in 26 cases (34 hips), ankylosis of the hip in 15 cases (16 hips), and fracture of the femoral neck in 1 case (1 hip). The Harris score was 32.49 ± 9.50. The physical component summary (PCS) and mental component summary (MCS) of short form 36 health survey scale (SF-36) scores were 25.53 ± 4.46 and 42.28 ± 6.27, respectively. ResultsAll incisions healed primarily. All 42 patients were followed up 5-21 years (mean, 9.1 years). At last follow-up, the Harris score was 89.25 ± 8.47; PCS and MCS of the SF-36 were 51.35 ± 4.28 and 55.29 ± 8.31, respectively; and significant differences in the scores were found between pre- and post-operation (P lt; 0.05). Complications included limp (4 cases), prosthesis dislocation (2 cases, 2 hips), periprosthetic fracture (1 case, 1 hip), aseptic loosening (2 cases, 2 hips), and ectopic ossification (3 cases, 3 hips). ConclusionTHA seems to be a good choice for patients with chronic autoimmune inflammatory diseases.
In order to characterize the characteristics of pathological tremor of human upper limb, a simulation system of pathological tremor of human arm was provided and its dynamic response was analyzed. Firstly, in this study, a two-degree-of-freedom human arm dynamic model was established and linearized according to the arbitrary initial angle of joints. After solving the analytical solutions of steady-state responses of the joints, the numerical solution was used to verify it. The results of theoretical analysis show that the two natural frequencies of the developed dynamic model are 2.9 Hz and 5.4 Hz, respectively, which meet the characteristic frequency range of pathological tremors. Then, combined with the measured parameters of human arm, a tremor simulation system was built, and the measured results of joint responses are in good agreement with the theoretical and simulation analysis results, which verifies the effectiveness of the theoretical model. The results show that the human arm pathological tremor simulation system designed in this paper can characterize the frequency and response amplitude of the human upper limb pathological tremor. Moreover, the relevant research lays a theoretical foundation and experimental conditions for the subsequent development of wearable tremor suppression devices.