west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Heart" 192 results
  • Detection method of early heart valve diseases based on heart sound features

    Heart valve disease (HVD) is one of the common cardiovascular diseases. Heart sound is an important physiological signal for diagnosing HVDs. This paper proposed a model based on combination of basic component features and envelope autocorrelation features to detect early HVDs. Initially, heart sound signals lasting 5 minutes were denoised by empirical mode decomposition (EMD) algorithm and segmented. Then the basic component features and envelope autocorrelation features of heart sound segments were extracted to construct heart sound feature set. Then the max-relevance and min-redundancy (MRMR) algorithm was utilized to select the optimal mixed feature subset. Finally, decision tree, support vector machine (SVM) and k-nearest neighbor (KNN) classifiers were trained to detect the early HVDs from the normal heart sounds and obtained the best accuracy of 99.9% in clinical database. Normal valve, abnormal semilunar valve and abnormal atrioventricular valve heart sounds were classified and the best accuracy was 99.8%. Moreover, normal valve, single-valve abnormal and multi-valve abnormal heart sounds were classified and the best accuracy was 98.2%. In public database, this method also obtained the good overall accuracy. The result demonstrated this proposed method had important value for the clinical diagnosis of early HVDs.

    Release date:2023-12-21 03:53 Export PDF Favorites Scan
  • Changes and Significancy of Adrenomedullin, Atrial Natriuretic Polypeptide and Heart Rate Variability in Patients with Obstructive Sleep Apnea-Hypopnea Syndrome

    Objective To investigate the changes and clinical relationship of plasma adrenomedullin( ADM) , atrial natriuretic polypeptide( ANP) , and heart rate variability( HRV) in patients with obstructive sleep apnea-hypopnea syndrome ( OSAHS) . Methods Seventy-five inpatients with OSAHS were enrolled in this study. According to the apnea hypopnea index ( AHI) by polysomnography, the subjects were divided into a mild group, a moderate group, and a severe group. Meanwhile, HRV was screened bydynamic electrocardiogram in sleep laboratory. HRV parameters were obtained including LF ( low frequency power) , HF( high frequency power) , pNN50( percentage of NN50 in the total number of N-N intervals) ,SDNN( standard deviation of the N-N intervals) , rMSSD( square root of the mean squared differences of successive N-N intervals ) . Plasma levels of ADM/ANP were measured by radioimmunoassay. Results The levels of SDNN ( P lt;0. 05) , rMSSD, pNN50, LF ( P lt; 0. 05) and HF were gradually reduced, and the levels of ADM ( P lt;0. 05) and ANP ( P lt; 0. 05) were increased with increasing severity of OSAHS. Linear correlation analysis demonstrated that SDNN was negatively correlated with ADM( r = - 0. 423, P lt;0. 05)and ANP( r = - 0. 452, P lt; 0. 05) , and LF was also negatively correlated with ADM( r = - 0. 348, P lt;0. 05) . Conclusion Lower HRV is associated with more sever OSAHS, and it may be modulated neurohumorally by ADM and ANP.

    Release date:2016-09-14 11:25 Export PDF Favorites Scan
  • A review of deep learning methods for non-contact heart rate measurement based on facial videos

    Heart rate is a crucial indicator of human health with significant physiological importance. Traditional contact methods for measuring heart rate, such as electrocardiograph or wristbands, may not always meet the need for convenient health monitoring. Remote photoplethysmography (rPPG) provides a non-contact method for measuring heart rate and other physiological indicators by analyzing blood volume pulse signals. This approach is non-invasive, does not require direct contact, and allows for long-term healthcare monitoring. Deep learning has emerged as a powerful tool for processing complex image and video data, and has been increasingly employed to extract heart rate signals remotely. This article reviewed the latest research advancements in rPPG-based heart rate measurement using deep learning, summarized available public datasets, and explored future research directions and potential advancements in non-contact heart rate measurement.

    Release date: Export PDF Favorites Scan
  • Clinical Application of Cardiopulmonary Bypass through Intubation of Femoral Artery and Vein for Completely Video Assisted Cardiac Surgery

    Objective To discuss the way and management of cardiopulmonary bypass (CPB) through intubation of femoral artery and femoral vein for completely video assisted cardiac operations, Methods CPB were set up through femoral artery and femoral vein in 85 patients on heart surgery by video assisted thoracotomy. Thirtyeight patients were diagnosed as atrial septal defect (ASD), forty-three patients were diagnosed as ventricular septal defect (VSD), and four patients were mitral valve stenosis and mitral incompetence (MS+MI),The video assisted thoracotomy was used to repair ASD, VSD and mitral valve replacement (MVR). Results For all patients the durations of CPB and aortic cross-clamping time was 30-179 min(91.7±27.4 min), 6-103 min(37.2±6. 1 min). In one patient, the CPB was set up again for repairing of residual leak. The endothelium of femoral artery was lacerated during withdrawing the cannula in 2 patients. Conclusion The video assisted thoracic operation with CPB and by intubation of femoral artery and femoral vein to perform heart operation are feasible and safe. All patients are recovered well.

    Release date:2016-08-30 06:26 Export PDF Favorites Scan
  • Learning Curve of Allogeneic Mouse Model of Peritoneal Heart Transplantation

    Allogeneic mouse model of peritoneal heart transplant is a microscopic surgery on small animal with complex techniques. For a beginner, a learning curve of this surgical technique has to be experienced. The learning curve contains three stages:(1) to be familiar with the local anatomy of either donor or recipient mouse; (2) to be capable of collecting donor heart and well preparing the major peritoneal vessels of recipient; (3) to be skillful in the anastomosis of major vessels. The bottleneck of the learning curve is the valid skill of vascular anastomosis. The stepwise essentials are to "understand, be familiar, be accurate, and be quick" in the learning curve.

    Release date:2016-10-02 04:56 Export PDF Favorites Scan
  • Cardiac Protection of High Thoracic Epidural Anesthesia for Patients with Acute Coronary Syndrome or Heart Failure: A Systematic Review

    Objective To evaluate the cardiac protection function of high thoracic epidural anesthesia (HTEA) for patients with acute coronary syndrome or heart failure. Methods A literature search was conducted with computerized database on PubMed, EBSCO, Springer, Ovid, and CNKI from 1990 to May 2010. Further searches for articles were conducted by checking all references describing cardiac protection studies with HTEA. All included articles were assessed and data were extracted according to the standard of Cochrane review. The homogeneous studies were pooled using RevMan 4.2.10 software. Results A total of 28 articles involving 1 041 patients were included. The results of meta-analyses showed that, a) cardiac function: HTEA could significantly improve ejection fraction of left ventricle (WMD= – 10.28, 95%CI – 14.14 to – 6.43) and cardiac output (WMD= – 1.26, 95%CI – 1.63 to – 0.89), contract left ventricular diastolic dimension (WMD= 5.02, 95%CI 3.72 to 6.32), increase E peak (WMD= – 17.50, 95%CI – 29.40 to – 5.59) and decrease A peak (WMD= 27.36, 95%CI 24.46 to 30.26); b) ischemic degree for patients with heart failure: the change of NST-T (WMD= 1.45, 95%CI 1.12 to 1.78) and ∑ST-T (WMD= 1.02, 95%CI 0.78 to 1.26) got significantly decreased after HTEA; c) ischemic degree for patients with acute coronary syndrome: HTEA could obviously lessen the times (WMD= 4.24, 95%CI 0.48 to 8.00) and duration (WMD= 23.29, 95%CI 4.66 to 42.11) of myocardial ischemia, decrease the times of heart attack (WMD= 3.44, 95%CI 0.92 to 5.97), and decrease the change of NST-T (WMD= 1.10, 95%CI 0.84 to 1.36) and ∑ST-T (WMD= 1.33, 95%CI 1.01 to 1.65); d) hemodynamic change for patients with acute coronary syndrome: HTEA could obviously decrease heart beat (WMD= 8.44, 95%CI 3.81 to 13.07) and systolic arterial pressure (WMD= 2.07, 95%CI 0.81 to 3.34), but not decrease the diastolic blood pressure (WMD= 2.06, 95%CI – 0.52 to 4.64) so as to avoid influencing the infusion of coronary artery; and e) influence on Q-T interval dispersion: HTEA could significantly decrease Q-Td (WMD= 9.51, 95%CI 4.74 to 14.27), Q-Tcd (WMD= 11.82, 95%CI 5.55 to 18.09), and J-Td (WMD= 9.04, 95%CI 2.30 to 15.79). Conclusions High thoracic epidural anesthesia can obviously improve the systolic and diastolic function of left ventricle, decrease the heart beat and stabilize hemodynamic change, lessen the times and duration for myocardial ischemia, reserve the ST segment change, contract Q-T interval dispersion, which has to be further proved with more high quality studies.

    Release date:2016-09-07 11:09 Export PDF Favorites Scan
  • Efficacy of MitraClip Therapy in Heart Failure Patients with Mitral Insufficiency: A Meta-analysis

    ObjectiveTo systematically review the efficacy of MitraClip therapy in heart failure patients with mitral insufficiency. MethodsDatabases including PubMed, The Cochrane Library (Issue 11, 2014), EMbase, CBM, CNKI, VIP and WanFang Data were searched from October 2005 to October 2015 to collect before-after controlled studies about the efficacy of MitraClip therapy in heart failure patients with mitral insufficiency. Two reviewers independently screened literature, extracted data and assessed the methodological quality of included studies. Then, meta-analysis was performed using RevMan 5.2 software. ResultsA total of 9 studies involving 782 patients were included. The results of meta-analysis showed that, compared with their conditions before treatment, patients after the MitraClip implantation had a declined NYHA class Ⅲ-Ⅳ ratio (RD=0.72, 95%CI 0.60 to 0.85, P<0.000 01), increased left ventricular ejection fraction (LVEF) (MD=-2.97,95%CI -5.06 to -0.89,P<0.005) and improved performance in 6 min walk-test (6-MWT) (MD=-88.73, 95%CI -157.16 to -20.31, P=0.01). ConclusionMitraClip therapy can, to a certain extent, improve the cardiac function of patients with heart failure and mitral insufficiency. However, further studies are needed to confirm its effects on improving the long-term survival of patients.

    Release date: Export PDF Favorites Scan
  • Efficacy and safety of SGLT2 inhibitors for heart failure: a network meta-analysis

    Objective To systematically review the efficacy and safety of different SGLT2 inhibitors in the treatment of heart failure. Methods The Cochrane Library, Web of Science, PubMed and EMbase databases were searched for randomized controlled trials on the efficacy and safety of SGLT2 inhibitors in patients with heart failure from inception to July 2, 2021. Two researchers independently screened literature, extracted data and evaluated the risk of bias of the included studies. Network meta-analysis was then performed using Stata 16.0 software. Results A total of 16 randomized controlled trials, including 15 312 patients, involving 5 interventions, namely dapagliflozin, empagliflozin, canagliflozin, sotagliflozin and ertugliflozin were included. Results of network meta-analysis showed that there was no significant difference in the compound outcome of hospitalization for heart failure or cardiovascular death, hospitalization for heart failure, all-cause mortality, risk of cardiovascular mortality and serious adverse reactions among patients with heart failure among 5 different SGLT2 inhibitors (P>0.05). Compared with placebo, both selective and non-selective SGLT2 inhibitors improved the risk of hospitalization for heart failure, hospitalization for heart failure, or compound cardiovascular mortality (P<0.05), while only selective SGLT2 inhibitors improved the risk of cardiovascular mortality, all-cause mortality, and serious adverse events (P<0.05). However, there was no significant difference between them (P>0.05). The area under the cumulative ordering probability curve of selective and non-selective SGLT2 inhibitors ranked first and second, except for the combined outcome of heart failure or cardiovascular death. Conclusion The current evidence indicates that there is no significant difference in the efficacy and safety of the 5 different SGLT2 inhibitors in the treatment of heart failure, and there is no significant difference between selective SGLT2 inhibitors and non-selective SGLT2 inhibitors. Due to the limited quantity and quality of included studies, more high-quality studies are needed to verify the above conclusion.

    Release date:2022-03-29 02:59 Export PDF Favorites Scan
  • Progress in Early Diagnosis and Treatment of Severe Heart and Great Vessel Injury

    Severe heart and great vessel injuries were a fatal traumatic entity. How to improve the survival rate of these victims still was a challenge to date. This paper included: the pathogenesis and resuscitation of commotio eordis ; traumatic pericardial rupture associated with heart luxation and/or diaphragmatocele in pericardial cavity; indication selection of emergency room thoracotomy for severe heart injury and traumatic aortic disruption treated with endovascular stent graft. For the purpose of increasing our recognition of the severe trauma and making the early diagnosis and management as early as possible. The main relative references published in recently 5 years were reviewed.

    Release date:2016-08-30 06:22 Export PDF Favorites Scan
  • Progress of the Third Generation Blood Pumps

    Abstract: The ventricle assist device has emerged as an important therapeutic option in the treatment of both acute and chronic heart failure. The blood pumps which are the major components of ventricle assist devices have also progressed to the third generation. The magnetic and/or liquid levitation technologies have been applied into the third generation blood pumps. The impellers which drive blood are levitated in the blood pumps. The third generation blood pumps are mainly composed of the levitation system and the driving system. The development of the third generation blood pumps has three stages: the stage of foreign motor indirectly driving the impeller with the levitation and driving system separated, the stage of motor directly driving the impeller with the levitation and driving system separated, and the stage of levitation system integrated with the driving system. As the impellers do not contact with other structures, the third generation blood pumps possess the advantages of low thrombosis, less hemolysis and high energy efficiency ratio. Currently most of the third generation blood pumps are in the research stage, but a few number of them are used in clinical trials or applying stage. In this article, the history, classification, mechanism and research situation of the third generation blood pumps are reviewed.

    Release date:2016-08-30 06:02 Export PDF Favorites Scan
20 pages Previous 1 2 3 ... 20 Next

Format

Content