In order to seek a good method to treat the severe, complex damage of the digital flexor tendon, an anatomical study based on 30 cadavers was done, and the result showed that the source of the blood supply to the palmaris longus tendon was from the radial and ulnar arteries. Three cases of severe complex digital flexor tendon injuries were satisfactory. Its main advantages were: (1) The tendon transplant had its own blood supply and had no need to the revascularization, therefore the adhesion formed between the tendon and adjacent tisues might be less;(2) Besides reparing the tendon defect, it can simultaneously solve the problem of the defect of the soft tissues and the skin.
The digital defects which severely interfered with the hand functions must be reconstructed. The primary repair by vascularized skin flap with the dorsal branch of proper palmar digital nerve could be done. The vascularized flap was rich in blood circulation, perfect sensibility and a good contour, as well as preserving donor digital sensation. However, it was simple, safe, and with higher success. From 1989 to 1991, 10 cases of digital defects were treated, all of the patients gained very good results. The indication and technique of thismethod wasdiscussed in detail.
With the development of computer and digital technology, the application of computer-aided technology has become a new trend in the field of oral implant. Computer-guided oral implant surgery has the advantages of being safer and more accurate than traditional implant surgery, and it can truly realize the concept of restoration-oriented implant. However, computer-guided oral implant surgery has various steps which cause deviations accumulation, so that some clinicians remain sceptical about the accuracy of the technology. Currently, due to the lack of a quantitative system for evaluating the accuracy of computer-guided oral implantation, the implant deviation in each step is still inconclusively in the stage of research and debate. The purpose of this paper is to summarize the advantages and disadvantages, research progress, accuracy and influencing factors of computer-guided oral implantation, aiming to provide a reference for improving implant accuracy and guiding clinical design and surgery.
ObjectiveTo investigate the decompression and diverting effects of vascular anastomosis based on the digital arterial arch branch in replantation of free finger-pulp in distal phalanges. MethodsA retrospective analysis was performed on the clinical data of 12 patients (12 fingers) who underwent free finger-pulp replantation with anastomosis of proper palmar digital artery and the palmar digital artery arch branch in the distal end between December 2004 and March 2015. Of 12 cases, 9 were male and 3 were female, aged 15-39 years with an average of 32 years. The causes of injury included cutting injury in 4 cases, crush injury in 7 cases, and avulsion injury in 1 case. The thumb was involved in 2 cases, index finger in 4 cases, ring finger in 3 cases, middle finger in 1 case, and little finger in 2 cases. The free finger pulp ranged from 1.8 cm×1.5 cm to 2.8 cm×2.0 cm. The time from injury to operation ranged from 1.5 to 11.0 hours, with an average of 5.7 hours. No arterial arch or proper palmar digital arteriae anastomosis was excluded. ResultsFree finger-pulp survived in 11 cases after operation; venous crisis occurred in 1 case at 2 days after operation, and was cured after symptomatic treatment. Nine cases were followed up 6-18 months with an average of 10 months. The finger-pulp had good appearance, clear fingerprint, and soft texture. The two-point discrimination was 3.1-6.0 mm, with an average of 4.6 mm at 6 months after operation. The function of finger flexion and extension was normal. And according to upper extremity functional evaluation standard by hand surgery branch of Chinese Medical Association, the results were excellent in 7 cases, and good in 2 cases. ConclusionIn the replantation of amputated pulp with insufficiency of venous blood outflow, the anastomosis of digital arterial arch branch in the distal end can decompress and shunt arterial blood, adjust blood inflow and outflow, and solve the problems of insufficient quantity of the vein and venous reflux disturbance.
ObjectiveTo explore the application value of digital subtraction angiography (DSA) in repairing foot and ankle wounds with posterior tibial arterial perforator flaps. MethodsBetween January 2010 and May 2014, 12 cases of foot and ankle wounds were repaired using posterior tibial arterial perforator flaps. There were 7 males and 5 females with an average age of 36 years (range, 22-54 years). The causes were machine injury in 2 cases, falling injury in 3 cases, and traffic accident injury in 7 cases. The disease duration ranged from 7 to 45 days (mean, 16 days). The size of wound ranged from 6 cm×4 cm to 10 cm×5 cm. Preoperative DSA was performed to observe the orientation and distribution of the posterior tibial arterial perforator and the relationship between perforator vessels. Correspondently, the flaps were designed and harvested. The size of flap ranged from 7 cm×5 cm to 11 cm×6 cm. The donor sites were repaired with skin grafts. ResultsPosterior tibial arterial perforator vessels send out ascending branches and descending branches while going down in the superficial layer. All branches were connected to form vertical chain-form anastamosis, and its orientation was consistent with limb vertical axis. According to DSA results, the flaps were designed and harvested easily. All flaps survived after operation. Meanwhile, wounds healed by first intention. All skin grafts at donor site survived. All patients were followed up 6 months. The flaps had good appearance, color, and texture. No ulcer was found. Affected feet had normal walking function. ConclusionThe size, distribution, and chain-form anastamosis condition of the posterior tibial arterial perforator vessels can be accurately observed by DSA, which provides imaging evidence for harvesting posterior tibial arterial perforator flaps and improves the success rate for repairing foot and ankle wounds.
Objective To investigate the therapeutic effect of V-Y advancement flap pedicled with dorsal cutaneous branch of digital artery for skin defect at the same dorsal finger. Methods Between January 2008 and February 2010, 15 cases of skin defect at the same dorsal finger were treated. There were 9 males and 6 females, aged 15-72 years (mean, 43 years). Defect was caused by saw machine in 6 cases, machines crush in 7 cases, and cutting nodule in 2 cases. The locationswere distal dorsal finger in 2 cases, middle dorsal finger in 6 cases, and proximal dorsal finger in 7 cases. All cases compl icated by exposure of tendon and bone. The size of defect ranged from 0.8 cm × 0.5 cm to 1.4 cm × 1.0 cm. The interval between injury and operation was 3-8 hours. All fingers were treated by V-Y advancement flap from the dorsal cutaneous branch of digital artery, which size was 1.2 cm × 0.8 cm-2.5 cm × 1.0 cm, and the donor site was directly sutured. Fracture reductionand Kirschner wire for internal fixation were performed in the patients with fracture; extensor tendon was repaired with 4-0 thread in the patients with tendon injury. Results All flaps survived completely. The incisions of donor and recipient sites healed by first intention. Ten cases were followed up 6 months to 2 years after operation. The flaps had good texture, color, and appearance; 2-point discrimination of the V-Y flap was 10-12 mm. X-ray examination showed that all finger fractures healedsuccessfully in 5 cases, with an average bone union time of 6 weeks (range, 5-8 weeks). According to the criteria for function assessment by total active motion, the results were excellent in 8 cases, good in 1, and fair in 1 with an excellent and good rate of 90%. Conclusion It is an ideal method to treat skin defect at the same dorsal finger with V-Y advancement flap pedicled with dorsal cutaneous branch of digital artery.
Objective To observe the complication after embolizing the bilateral internal il iac arteries and the median sacral artery of dogs by different combinations and embolization levels with gelfoam particle, and to provide a reference for safety appl ication of gelfoam in cl inic. Methods Sixteen common grade adult healthy dogs (weighing 10-13 kg, 14 males and 2females) were randomly divided into 5 groups. Under the monitoring of digital subtraction angiography (DSA), the embolization was performed with gelfoam particle (diameter, 50-150 μm) in bilateral internal il iac arteries and the main branch of the median sacral artery (group A, n=3), in bilateral internal il iac arteries and the first branch of the median sacral artery (group B, n=3), in the main branch of bilateral internal il iac arteries (group C, n=3), in the unilateral internal il iac artery and the main branch of the median sacral artery (group D, n=4), and in the main branch of unilateral internal il iac artery (group E, n=3). Under the DSA, the anatomic relationships of the abdominal aorta, bilateral external il iac arteries, bilateral internal il iac arteries, and median sacral artery were observed before embol ization. The survival dogs were observed and the specimens of bladder, rectum, sciatic nerve, and gluteal muscles were harvested for the general and histological observations at 3 days after embolization. Results In dogs, there was no common il iac artery; bilateral external il iac arteries originated from the abdominal aorta and the starting of the median sacral artery had variation. Seven dogs (3 in group A, 3 in group C, and 1 in group D) died within 2 days after embolization, and the others survived to the end of the experiment. In the dead dogs of groups A, C, and D, the darkening and necrosis of the rectum were observed; the bladder presented lamellar obfuscation and focal hemorrhage and edema; and the median urinary volume in bladder was 270.6 mL. In survival dogs, no obvious change was observed in the rectum; the bladder only manifested l ight edema; and the median urinary volume in bladder was 137.0, 220.5, and 28.0 mL, respectively in groups B, D, and E.The rectum and bladder of dead dogs in groups A, C, and D manifested the disrupted cells, generous inflammatory cells infiltration, and desquamation of epithel ial cells; the rectum and bladder of survival dogs in groups B, D, and E manifested l ight inflammatory cells infiltration and edema; the embol ized artery mainly focused on the arterioles whose diameter was 100-200 μm. The sciatic nerve and gluteal muscles of each group had no obvious change except for l ight edema. Conclusion When the internal il iac artery and median sacral artery are embol ized with gelfoam particle with a diameter of 50-150 μm, to ensure the safeness of pelvic organs, the embol ized artery can not exceed the first branch when the 3 arteries are embol ized at the same time, or reserve at least unilateral internal il iac artery when embol ized to the trunk , or it will result in pelvic organ necrosis and perforation.
Objective To compare the digital drainage system and the traditional drainage system in the patients after lung surgery, and to evaluate the advantages of digital drainage system. Methods A retrospective analysis of consecutive 42 patients with lung surgery between September 2016 and May 2017 in Beijing University International Hospital was done. There were 30 males and 12 females with a median age of 34 years ranging 19-81 years. After the surgery 21 patients adopted Thopaz digital drainage device (a DDS group), and the other 21 patients adopted traditional drainage (a TDS group). Duration of air leakage and chest tube placement, length of hospital stay, thoracic drainage volume within 48 h and hospitalization expenses in the two groups were compared. Results The patients in the two groups were all successfully discharged. Compared with the TDS group, duration of air leakage and chest tube placement and length of hospital stay significantly shortened in the DDS group (35.6±16.3 h vs. 48.2±20.1 h, P=0.02; 50.0±16.1 h vs. 62.0±20.4 h, P=0.03; 5.9±2.3 d vs. 7.8±3.5 d, P=0.02), and thoracic drainage volume within 48 h and hospitalization expenses showed no significant statistical difference between the two groups. Conclusion Using digital drainage system after lung surgery can significantly shorten the duration of air leakage and the postoperative drainage, at the same time, without increasing the overall hospitalization expenses.
To assess the rel iabil ity of diabetic cutaneous ulcer surface area (DCUSA) measurement usingdigital planimetry method (A) and transparency tracing method (B). Methods Images of diabetic cutaneous ulcers from35 inpatients with diabetic skin ulcers from September 2005 to April 2007 were taken by a digital camera once a week or twice a week over a period of 12 weeks, resulting in 305 photographs; the ulcers were traced on a grid with acetate wound tracings, simultaneously. A total of 305 pairs of DCUSA which were calculated respectively throughout digital camera combined with Image J medical imaging software and transparency tracing with grid sheet by two independent observers sequentially were obtained. The intraclass correlation coefficients (ICCs, one-way random effect model) was used as an indicator of chancecorrected agreement to estimate the relative rel iabil ity for the interobserver data. Multiple l inear regression analysis was also used to measure the relationship of these two methods. Results DCUSA obtained from method A and obtained from method B was (4.84 ± 7.73) cm2 and (5.03 ± 7.89) cm2, respectively; no significant difference was found (P gt; 0.05). ICCs was high (ICCs=0.949 for method B and 0.965 for method A), indicating that the relative rel iabil ity for the interobserver was excellent. The method A were highly correlated with measurements obtained from method B (r = 0.957, P lt; 0.05). Conclusion The digital planimetry method described in this study represents a simple, practical, without any wound damage and contamination, and inexpensive technique to accurately evaluate the areas of diabetic cutaneous ulcers. The photographic technique combined with Image J medical imaging software should be considered for wound measurement.
ObjectiveTo investigate the accuracy of preoperative digital-template planning in total hip arthroplasty (THA) via direct anterior approach (DAA) and its effect on the short-term effectiveness.MethodsThe clinical data of 77 patients (109 hips) with osteonecrosis of femoral head who underwent THA via DAA between January 2016 and May 2018 was retrospectively analyzed. According to the type of template, patients were divided into digital-template group (group A, 40 patients, 56 hips) and conventional-template group (group B, 37 patients, 53 hips). There was no significant difference in age, gender, body mass index, the stages of osteonecrosis of femoral head, and preoperative Harris hip score (HHS) (P>0.05). The operation time, intraoperative blood loss, frequencies of intraoperative fluoroscopy, and complications were recorded. Otherwise, the consistency rate of preoperative planning and practical prosthesis size was analyzed. Position of acetabular prosthesis and femoral prosthesis alignment were measured on anteroposterior X-ray film of the pelvis at 3 months after operation. HHS was used to evaluate clinical function.ResultsThe consistency rate of preoperative planning and practical acetabular prosthesis size was significantly higher in group A (80.4%, 45/56) than that in group B (62.3%, 33/53), showing significant difference (χ2=4.38, P=0.04). But there was no significant difference in the consistency rate of preoperative planning and practical femoral prosthesis size between group A (83.9%, 47/56) and group B (79.2%, 42/53)(χ2=0.40, P=0.53). The prosthesis abductions were (40.7±6.4)° in group A and (38.8±7.3)° in group B; the femoral prosthesis alignment deviations were (0.1±1.8)° in group A and (0.3±1.7)° in group B. There was no significant difference in the prosthesis abduction and femoral prosthesis alignment deviation between 2 groups (P>0.05). No prosthesis sinking or loosening occurred during follow-up. The operation time and frequencies of intraoperative fluoroscopy were less in group A than those in group B (P<0.05). But there was no significant difference in intraoperative blood loss between 2 groups (t=1.92, P=0.06). The complication occurred in 1 hip of group A and 6 hips of group B, with no significant difference (P=0.06). All patients were followed up 6-22 months (mean 13.8 months) in group A and 6-24 months (mean, 14.6 months) in group B. At last follow-up, the HHS scores were 91.8±3.1 in group A and 92.6±4.2 in group B, and the difference was not significant (t=1.14, P=0.26).ConclusionPreoperative digital-template planning in THA via DAA is accurate, which can reduce the operation time and frequencies of intraoperative fluoroscopy without enhancing the risk of complication.