west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Diagnostic test" 83 results
  • Evidence-Based Laboratory Medicine

    Release date:2016-08-25 03:33 Export PDF Favorites Scan
  • Evidence-Based Laboratory Medicine

    Release date:2016-09-07 02:27 Export PDF Favorites Scan
  • Diagnostic value of MR for pulmonary embolism: a meta-analysis

    ObjectiveTo systematic review the diagnostic value of magnetic resonance (MR) for pulmonary embolism (PE).MethodsWe electronically searched databases including EMbase, PubMed, The Cochrane Library, WanFang Data and CNKI from inception to November 2016, to collect the diagnostic studies about MR in the diagnosis of PE. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data, and assessed the risk of bias of included studies, and then meta-analysis was conducted using Stata 12.0 software.ResultsA total of 14 studies involving 1 042 patients were included. The pooled Sen, Spe, +LR, –LR and DOR were 0.90 (95%CI 0.83 to 0.94), 0.95 (95%CI 0.90 to 0.98), 19.8 (95%CI 8.5 to 46.1), 0.10 (95%CI 0.06 to 0.18), 189 (95%CI 69 to 521), respectively. The AUC of SROC were 0.97 (95%CI 0.95 to 0.98).ConclusionMR has a good diagnosis value for PE which can be regarded as an effective and feasible method for suspected PE patients, especially for those who has contraindication of computed tomographic pulmonary angiography.

    Release date:2017-07-19 10:10 Export PDF Favorites Scan
  • Diagnostic value of optical coherence tomography angiography in primary open-angle glaucoma: a meta-analysis

    ObjectiveTo systematically review the diagnostic value of optical coherence tomography angiography (OCTA) for primary open-angle glaucoma (POAG). MethodsThe CNKI, WanFang Data, VIP, CBM, PubMed, Embase, Web of Science, and Cochrane Library databases were electronically searched to collect diagnostic test on OCTA for POAG from inception to February 2024. Two reviewers independently screened literature, extracted data and assessed the risk of bias of the included studies. Meta-analysis was then performed by using Stata 15.0 software. ResultsA total of 12 diagnostic tests involving 993 subjects were included. Meta-analysis results showed that the sensitivity/specificity of OCTA for diagnosing peripapillary vessel density, retinal vessel density, and optic nerve fiber changes in patients with POAG were 0.77/0.92, 0.56/0.92, and 0.85/0.91, respectively, and the AUC of the SROC curve was 0.94, 0.92 and 0.95, respectively. ConclusionOCTA has high diagnostic accuracy for POAG. Due to the limited quality and quantity of the included studies, more high quality studies are needed to verify the above conclusion.

    Release date:2025-02-25 01:10 Export PDF Favorites Scan
  • Diagnostic Value of Gadoxetic Acid Disodium (Gd-EOB-DTPA) for the Detection of Liver Metastases: A Meta-analysis

    ObjectiveTo systematically review the diagnostic value of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) for liver metastases. MethodsWe searched databases including CNKI, CBM, VIP, WanFang Data, PubMed, EMbase and The Cochrane Library from January 2011 to December 2014 to collect diagnostic tests about Gd-EOB-DTPA for liver metastases. Two reviewers independently screened literature, extracted data, and assessed the risk of bias of included studies by using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) tool. Then, meta-analysis was performed by using Stata 12.0 software. ResultsA total of 15 studies from seven countries were included, involving 2 040 nodules from 701 patients. The results of meta-analysis showed that, the pooled sensitivity (Sen), specificity (Spe), positive likelihood ratio (+LR), negative likelihood ratio (-LR) and diagnostic odds ratio (DOR) of Gd-EOB-DTPA for liver metastases were 0.92 (95%CI 0.89 to 0.95), 0.94 (95%CI 0.89 to 0.97), 14.51 (95%CI 8.01 to 26.28), 0.08 (95%CI 0.06 to 0.12), and 177.98 (95%CI 89.50 to 353.94), respectively. The area under curve (AUC) of SROC was 0.97 (95%CI 0.95 to 0.98). The results of subgroup analysis showed that Gd-EOB-DTPA had better Sen in nodules >10 mm than the nodules ≤10 mm in diameter (>10 mm: pooled Sen=0.97, 95%CI 0.94 to 0.99; ≤10 mm: pooled Sen=0.75, 95%CI 0.65 to 0.85; P<0.001); The 3.0T MR had better Sen in diagnosing liver metastases compared with 1.5T MR (3.0T: pooled Sen=0.95, 95%CI 0.92 to 0.97; 1.5T: pooled Sen=0.90, 95%CI 0.87 to 0.94; P<0.001). ConclusionGdEOB-DTPA is of value for the detection of liver metastases. In particular, it is of high sensitivity for the detection of nodules larger than 10 mm, and for the cases using 3.0T high-field MR system. Due to limited quantity and quality of the included studies, more high-quality studies are required to verify the above conclusion.

    Release date: Export PDF Favorites Scan
  • Diagnostic Value of Plasma Soluble Triggering Receptor Expressed on Myeloid Cells-1 for Sepsis: A Systematic Review

    Objective To evaluate the diagnostic value of soluble triggering receptor expressed on myeloid cells-1 (sTREM-1) for sepsis. Methods Such databases as The Cochrane Library (Issue 4, 2012), PubMed, EMbase, CBM, CNKI, VIP and WanFang Data were searched to collect the diagnostic tests on sTREM-1 for sepsis published before April 2012. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted the data, and assessed the methodological quality. Then, Meta-Disc software (Version 1.5) was used to conduct analyses, draw the summary receiver operating characteristic (SROC) curve, and calculate the area under curve and Q index. Results A total of 11 studies involving 1 615 patients were included. The value of sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, area under of SROC curve, and Q index were 69%, 71%, 3.7, 0.34, 14.73, 0.875, and 0.805, respectively. Conclusion This meta-analysis shows that sTREM-1 as a single indicator has moderate accuracy for early diagnosing sepsis. It should be combined with other diagnostic indicators to further improve the sensitivity and accuracy in diagnosing sepsis.

    Release date: Export PDF Favorites Scan
  • Advances in Research on Bias Sources in Diagnostic Test

    Diagnosis is the critical component of health care and the studies of diagnostic test can provide important evidence for clinical decisions. Studies of diagnostic test are subject to different sources of bias in design, performance and reporting of studies. Therefore, researchers who understand various sources of bias can reasonably perform the diagnostic test and evaluate its quality, and will provide scientific evidences for clinical practice.

    Release date:2016-09-07 11:06 Export PDF Favorites Scan
  • Diagnostic value of vascular endothelial growth factor-D for the diagnosis of lymphangioleiomyoatosis: a Meta-analysis

    Objective To evaluate the diagnostic value of vascular endothelial growth factor (VEGF)-D detection for the diagnosis of lymphangioleiomyomatosis (LAM) by Meta-analysis. Methods Literatures published before August 2017 were retrieved from PubMed, Embase, China Biology Medicine database, China National Knowledge Internet, Wangfang, and VIP database to retrieve the study about VEGF-D detection for LAM. The studies were screened according to the inclusive and exclusive criteria, the data were extracted, the quality was assessed and the Meta-analysis was performed with related statistical software. Results Six primary studies were included and 521 patients met the inclusion criterion. The Meta-analysis showed the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio of 0.75 [95% confidence interval (CI) (0.70, 0.79)], 0.95 [95%CI (0.91, 0.98)], 16.20 [95%CI (8.70, 30.19)], 0.20 [95%CI (0.10, 0.40)] and 89.49 [95%CI (38.46, 208.22)], respectively. The area under the curve was 0.953 9. Conclusions VEGF-D detection showes a good diagnostic value for LAM. A positive result is more clinical meaningful compared with a negative result, helping for the confirmation of the disease.

    Release date:2018-01-23 02:34 Export PDF Favorites Scan
  • Summary ROC curve-diagnostic test method of Meta-analysis

    In this paper, we introduce theory and practice method about combining independent studies of Diagnostic test into a summary ROC curve. This is a useful and easily applied by clinicians to analyse the data of diagnostic test. It’s referance for user and doer of EBM in China.

    Release date:2016-08-25 03:33 Export PDF Favorites Scan
  • The Effectiveness of NT-proBNP in Diagnosing Heart Failure

    Objective To evaluate the diagnostic value of N terminal pro-brain natriuretic peptide (NT-proBNP) for heart failure (HF) and the relationship between NT-proBNP and HF. Methods Applying electrochemiluminescence immunoassay on Elecsys 2 010 quantitatively detects NT-proBNP in HF patients with varing heart damage. Results ① Using 155 pg/ml as the cutoff for diagnosis of HF, the sensitivity and specificity are both 80 %, positive likelihood ratio (PLR) is more than 4.0; when NT-proBNP is more than 350 pg/ml, PLR is more than 14. ② NT-proBNP significantly increases in HF patients,and has significant difference compared with disease control group, Plt;0.05. In dilated cardiomyopathy (DCMP) and acute myocardial infarction (AMI) NT-proBNP is the highest, in coronary heart disease (CHD) and hypertension it’s the smallest. With rising NYHA classes, NT-proBNP increases exponentially. The correlation between NT-proBNP and heart function is good, rs=0.859 (Plt;0.01). Conclusions NT-proBNP for diagnosing HF has a high sensitivity and specificity and can effectively evaluate heart function. With worsening of heart damage, NT-proBNP shows exponential or linear increase.

    Release date:2016-09-07 02:25 Export PDF Favorites Scan
9 pages Previous 1 2 3 ... 9 Next

Format

Content