目的 探讨多层螺旋CT血管造影(CTA)在主动脉夹层中的诊断价值及临床应用。 方法 回顾性分析2010年2月-2011年4月35例行CTA检查的主动脉夹层患者,所有患者原始数据在图像后处理工作站采用多平面重建、容积再重建、最大密度投影等方法进行主动脉成像。由2名有经验的放射科副主任医师进行诊断。 结果 35例均可明确显示主动脉夹层的真假腔、内膜片及破裂口部位。Ⅰ型12例,Ⅱ型3例,Ⅲ型20例;累及左锁骨下动脉5例,左颈总动脉2例,无名动脉2例,腹腔干3例,肠系膜上动脉4例,左肾动脉3例,右肾动脉2例,右髂总动脉受累6例,左髂总动脉受累8例,其中双侧髂总动脉均受累4例;合并动脉瘤3例;壁内血肿4例;所有患者均显示了单一或多发破口。 结论 CTA及图像后处理技术能快速、准确地诊断主动脉夹层,为临床治疗方案选择提供重要的影像学依据。
Objective To explore the application value of artificial intelligence (AI) pulmonary artery assisted diagnosis software for suspected pulmonary embolism patients. Methods The data of 199 patients who were clinically suspected of pulmonary embolism and underwent pulmonary artery CT angiography (CTA) from June 2016 to December 2021 were retrospectively analyzed. Images of pulmonary artery CTA diagnosed by radiologists with different experiences and judged by senior radiologists were compared with the analysis results of AI assisted diagnostic software for pulmonary artery CTA, to evaluate the diagnostic efficacy of this software and low, medium, and senior radiologists for pulmonary embolism. The agreement of pulmonary embolism based on pulmonary artery CTA between the AI software and radiologists with different experiences was evaluated using Kappa test. Results The agreement of the AI software and the evaluation of pulmonary embolism lesions by senior radiologists based on pulmonary artery CTA was high (Kappa=0.913, P<0.001), while the diagnostic results of pulmonary artery CTA AI software was good after judged by senior radiologists based on pulmonary artery CTA (Kappa=0.755, P<0.001). Conclusions The AI software based on pulmonary artery CTA diagnosis of pulmonary embolism has good consistency with diagnostic images of radilogists, and can save a lot of reconstruction and diagnostic time. It has the value of daily diagnosis work and worthy of clinical promotion.
ObjectiveTo explore the value of multi-slice CT angiography (MSCTA) in peripancreatic vascular invasion of pancreatic carcinoma. MethodsThirty-eight patients with pancreatic carcinoma were detected by MSCTA technology before operation. The peripancreatic vascular invasion of pancreatic carcinoma was evaluated by multi-planar reconstruction (MPR) and maximum intensity projection (MIP) combined with axial image, and compared with the surgical results. ResultsThe MSCTA results showed that there were 12 patients (31.6%) with vascular invasion in 38 patients with pancreatic carcinoma, and the surgical results showed that there were 16 patients (42.1%) with vascular invasion. There was a b fit goodness of two results (kappa=0.665, P=0.000). The sensibility and specificity of MSCTA was 68.8% (11/16) and 95.5% (21/22), respectively. ConclusionsMSCTA technology has a high correct rate in evaluation of peripancreatic vessel encroached by pancreatic carcinoma, the MSCTA result has a b consistency to the surgical result. It has a value of clinical application in evaluation of peripancreatic vessel encroached by pancreatic carcinoma.
目的 总结腔内修复术治疗主动脉夹层的经验。方法 选择2011年7月至2013年1月期间我院住院的胸主动脉夹层患者15例,术前均采用CTA评估,全部行腔内修复术。结果 15例患者采用腔内修复手术全部成功,手术时间95~165min,(120±26) min;失血量30~160mL,(68±34) mL。10例采用经股动脉入路,5例采用经股动脉及肱动脉入路。13例单一破口者各植入支架1枚,手术全部成功。15例患者未发生截瘫,无一椎基底动脉缺血症状,无下肢缺血改变,无伤口感染及腹股沟区淋巴瘘。2例存在Ⅱ型内漏,未经处理自行闭合。随访胸腹主动脉CTA扫描显示覆膜支架均未移位,未发现植入支架后并发近端夹层者。结论 腔内修复术治疗主动脉夹层是一种有效的治疗方法,具有安全性高、术后并发症少、治疗效果好等优点。
ObjectiveTo observe the morphological characteristics of internal carotid artery (ICA) siphon and ophthalmic artery (OA) in patients with non-arteritic anterior ischemic optic neuropathy (NAION) based on CT angiography (CTA) three-dimensional reconstruction of ICA siphon and OA models. MethodsA retrospective cohort study. From January 2017 to January 2019, 26 patients with 31 eyes (NAION group) who were diagnosed with NAION by ophthalmic examination at Beijing Friendship Hospital, Capital Medical Universitywere included in the study. Among them, there were 11 males with 13 eyes, and 15 females with 18 eyes; the age was 67.52±6.30 years old. Nineteen eyes of 19 non-affected contralateral eyes were selected as the contralateral eye group. Among them, there were 9 males with 9 eyes and 10 females with 10 eyes; the age was 65.95±5.66 years old. Twenty-six eyes of 26 age- and sex-matched subjects with normal fundus examination during the same period were selected as the normal control group. All subjects underwent best corrected visual acuity (BCVA), intraocular pressure, fundus photography and CTA examination. The data obtained from CT scans were reconstructed by 3D model, and the anatomical morphology of ICA siphon was divided into U-shape, V-shape, C-shape and S-shape; the diameter of ICA siphon portion and the diameter at the beginning of OA were measured. One-way analysis of variance was used to compare the diameter of the OA at the beginning of the OA and the diameter of the ICA siphon between the three groups of eyes. ResultsThe diameters at the beginning of OA in the NAION group, the contralateral eye group, and the normal control group were 1.17±0.20, 1.34±0.17, and 1.39±0.15 mm, respectively, and the differences among the three groups were statistically significant (F=12.325, P<0.05); there was no significant difference between the contralateral eye group and the normal control group (P=0.310). In the NAION group, the anatomical morphology of the ICA siphon was U-shaped and V-shaped in 20 (64.52%) and 8 (25.81%) eyes respectively, and S and C-shaped in 3 eyes (9.67%); in the contralateral eye group, in the control group, the ICA siphon shape of the eyes examined was U-shaped and V-shaped, and S-shaped and C-shaped were rare. The diameters of the ICA siphons in the NAION group, the contralateral eye group, and the normal control group were 3.50±0.69, 3.22±0.59, and 3.55±0.54 mm, respectively. There was no significant difference between the three groups (F=1.860, P=0.163). ConclusionU-shaped and V-shaped ICA siphons are more common in NAION-affected eyes; the diameter of the starting point of OA is significantly reduced.
ObjectiveTo study the value of CT angiography (CTA) in the surgical treatment of bone tumors with the temporary balloon blocking technique. MethodsA retrospective analysis was made on the clinical data of 36 bone tumor patients between April 2008 and October 2013. There were 22 males and 14 females, aged from 25 to 83 years (mean, 46 years). The tumor located at the sacrococcygeal region in 17 cases, at the ilium in 12 cases, at the pubis in 5 cases, and at the proximal femur in 2 cases. Before surgery, CTA was performed to measure the external diameter of aortaventralis and arteria iliac communis, and the distance between the low renal artery and the abdominal aortic bifurcation as well as mark the anatomical relationship between the low renal artery, the abdominal aortic bifurcation and bony landmarks of vertebral body. According to these data, suitable balloon was chosen and the balloon positioning was guided in the surgery to completely excise tumor assisted by balloon blocking technique. ResultsThe CTA results showed that the external diameter of aortaventralis and arteria iliaca communis was (1.545±0.248) cm and (1.060±0.205) cm respectively, and the distance between the low renal artery and the abdominal aortic bifurcation was (10.818±1.165) cm. The three-dimensional reconstruction showed that the opening of the low renal artery was mainly located at L1 (16/36, 44.4%) and the abdominal aortic bifurcation mainly located at L4 (22/36, 61.1%). Effective block of abdomial aorta was performed; the blood pressure obviously increased in 3 cases after balloon inflation, and pulse of the left dorsal artery of the foot decreased in 1 case after removal of balloon, which were relieved after expectant treatment. The operation time was 118-311 minutes; the intraoperative blood loss was 200-1 800 mL, 21 patients were given blood transfusion, and the amount of blood transfusion was 400-1200 mL; and the aortic clamping time was 40-136 minutes. All patients were followed up 5-44 months (mean, 21 months). According to Enneking standard, the results were excellent in 9 cases, good in 20 cases, fair in 5 cases, and poor in 2 cases at 3 months after operation. There were 10 cases of dysfunction of urination and defecation, 2 cases of tumor recurrence, and 3 cases of death after surgery. ConclusionCTA and three-dimensional reconstructions technique can accurately measure the external diameter of aortaventralis and arteria iliaca communis and the distance between low renal artery and abdominal aortic bifurcation and offer great help to choose appropriate balloon and locate the balloon during surgery. The balloon blocking technique under the assistance of CTA can obviously reduce intraoperative blood loss and tumor recurrence, supply a clear view in surgery and shorten the operation time.
ObjectiveTo investigate the effectiveness of digital technology in repairing wounds of the hand and foot with anterolateral thigh flap. MethodsBetween September 2013 and September 2014, 16 cases of wounds of the hand and foot were treated with the anterolateral thigh flap. There were 10 males and 6 females, with an average age of 31 years (range, 20-52 years). The causes included traffic accident injury in 8 cases, crushing injury by machine in 6 cases, burning injury in 1 case, and animal biting injury in 1 case. The locations of soft tissue defect were the dorsum of the foot in 5 cases, the ankle in 4 cases, the planta pedis in 1 case, and the hand and forearm in 6 cases. The time was 2 hours to 45 days from injury to hospitalization (mean, 14.3 days). All defects were associated with exposure of bone and tendon. The size of wound was from 9.0 cm×4.0 cm to 29.0 cm×8.5 cm. CT angiography (CTA) was performed before operation, and the appropriate perforator as well as the donor site was selected. Then the Mimics15.0 software was used to reconstruct the data of CTA so as to locate the main perforators, design the three-dimensional models of the anterolateral thigh flap, and simulate operation. The flap was obtained according to preoperative plan during operation. The size of flaps varied from 11 cm×5 cm to 31 cm×10 cm. The donor sites were sutured directly in 14 cases and were repaired by free skin graft in 2 cases. ResultsThe lateral femoral circumflex artery identified by Mimics15.0 software before operation, as well as the starting position of its descending branch, the blood vessel diameter at start site, vascular distribution, the maximum cutting length of the vascular pedicle were consistent with the actual observation during operation. All flaps were harvested and were used to repair defect smoothly. Vascular crisis occurred in 1 flap after operation, and the other flaps survived successfully. The wounds and the incisions obtained healing by first intention, and grafted skin survived completely. All cases were followed up 6-17 months (mean, 9 months). Fifteen flaps had good shape;but a second-stage operation was performed to make the flap thinner in 1 case. At last follow-up, the results were excellent in 3 cases, good in 2 cases, and fair in 1 case according to total active motion (TAM) in 6 cases of hand and forearm injury;the results were excellent in 5 cases, good in 3 cases, and fair in 2 cases according to American Orthopaedic Foot and Ankle Society (AOFAS) in 10 cases of foot injury. The total excellent and good rate was 81.25%. ConclusionThe preoperative individualization design of the flap can be realized through CTA digital technology and Mimics15.0 software;it can reduce the operation risk.
ObjectiveTo explore the feasibility of three-dimensional (3-D) visualization reconstruction of the medial sural artery perforator flap based on digital technology. MethodsA series of Dicom images were obtained from three healthy adult volunteers by dual source CT angiography. Then the Mimics software was used to construct the medial sural artery model and measure the indexes, including the starting position of medial sural artery, external diameters of vascular pedicle, the number of perforators, location perforated deep fascia, and the maximum pedicle length of perforators based on medial sural artery perforator flap. ResultsThe 3-D visualization reconstruction models were successfully finished with Mimics software, which can clearly display the distribution, travel, and perforating point. Thirteen perforators were found in 6 legs, which started at the popliteal artery with a mean external diameter of 2.3 mm (range, 1.9-2.7 mm). Each specimen had 1-3 perforators, which located at the site of 6.2-15.0 cm distal to popliteal crease and 2.5-4.2 cm from posterior midline. The maximum pedicle length of medial sural artery perforator flap was 10.2-13.8 cm (mean, 11.8 cm). ConclusionThe 3-D visualization reconstruction models based on digital technology can provide dynamic visualization of the anatomy of the medial sural artery for individualized design of the medial sural artery perforator flap.
ObjectiveTo explore the evaluation value of preoperative multislice spiral computed tomography angiography (MSCTA) for normative radical gastrectomy. MethodsThe anatomic distributions of celiac trunk and its three branches and their tributaries (common hepatic artery, right hepatic artery, left hepatic artery, splenic artery, and left gastric artery) of 86 patients with gastric cancer were comprehended by preoperative MSCTA, which were verified during the surgery. Simultaneously preoperative TNM staging was evaluated by MSCTA, which compared with postoperative pathological results. ResultsThe accuracy rate of preoperative MSCTA evaluating the distribution of celiac trunk and its three branches and their tributaries was 100%. Abnormal hepatic arteries were found in 22 cases by MSCTA, the mutation rate was 25.58%. Abnormal right hepatic arteries were found in 11 cases (12.79%), abnormal left hepatic arteries in 7 cases (8.14%), both abnormal right and left hepatic arteries in 1 case (1.16%), and abnormal common hepatic arteries in 3 cases (3.49%). Straight splenic arteries were found in 24 cases (27.91%), slightly curved splenic arteries in 44 cases (51.16%), and significantly curved splenic arteries in 18 cases (20.93%). Compared with postoperative pathological results, the accuracy rates of preoperative MSCTA evaluating gastric cancer T, N, and M staging were 75.58%(65/86), 74.42%(64/86), and 91.86%(79/86), respectively. ConclusionsPreoperative MSCTA is an objective way to assess the distributions of celiac artery trunk and related tributaries of patients with gastric cancer. Also, it is an accurate method to evaluate the preoperative TNM stage of gastric cancer, which can help to make an individual operative plan and avoid the intraoperative injury of the artery.
Objective To investigate the accuracy of color Doppler ultrasound (CDU) and CT angiography (CTA) in the preoperative evaluation of perforator vessels in free posterior interosseous artery perforator (PIAP) flaps. Methods Between January 2020 and December 2023, 19 patients with hand skin and soft tissue defects caused by trauma were admitted. There were 11 males and 8 females, with a median age of 45 years (range, 26-54 years). The interval between injury and admission was 5-11 days (mean, 7.2 days). The skin and soft tissue defects were located on the dorsum of the hand in 8 cases and on the fingers in 11 cases. The size of defect ranged from 4.0 cm×2.5 cm to 7.5 cm×3.5 cm. After locating the perforator vessels through CDU and CTA before operation, the free PIAP flaps were designed to repair hand defects, with the size of 4.5 cm×3.0 cm-7.5 cm×4.0 cm. The defects of donor sites were directly sutured. The number and diameter of perforator vessels in the posterior interosseous artery detected by CDU and CTA were compared. The differences in localization of perforator vessels using CDU and CTA and their clinical effects were also compared to calculate the accuracy and recognition rate. During follow-up, the survival of the skin flap was observed, and the Vancouver scar scale (VSS) score was used to evaluate the healing of the donor site, while the visual analogue scale (VAS) score was used to evaluate the patient’s satisfaction with the appearance of the skin flap. Results The number and the diameter of PIAP vessels was 5.8±1.2 and (0.62±0.08) mm assessed by CDU and 5.2±1.0 and (0.60±0.07) mm by CTA, showing no significant difference between the two methods (P>0.05). The number, course, and distribution of perforator vessels of the PIAP vessels observed during operation were basically consistent with those detected by preoperative CDU and CTA. Compared with intraoperative observation results, the recognition rates of dominant perforating vessels by CDU and CTA were 95.0% (18/19) and 89.5% (17/19), respectively, and the accuracy rates were 100% (19/19) and 84.2% (16/19), with no significant difference between the two methods (P>0.05). All flaps survived after operation, and all wounds and incisions at donor sites healed by first intention. All patients were followed up 6-13 months (mean, 8.2 months). At last follow-up, the skin flaps had elasticity and soft texture, with the patient satisfaction VAS score of 9.2±0.8. The donor sites had no obvious scar hyperplasia with the VSS score of 11.7±0.9. Conclusion CDU and CTA accurately identify the dominant perforator vessels and provide reliable information for vessel localization, facilitating precise flap harvesting and minimizing donor site injury. However, CDU offers superior visualization of distal end of perforator vessels in the forearm compared to CTA.