With the development of computer and digital technology, the application of computer-aided technology has become a new trend in the field of oral implant. Computer-guided oral implant surgery has the advantages of being safer and more accurate than traditional implant surgery, and it can truly realize the concept of restoration-oriented implant. However, computer-guided oral implant surgery has various steps which cause deviations accumulation, so that some clinicians remain sceptical about the accuracy of the technology. Currently, due to the lack of a quantitative system for evaluating the accuracy of computer-guided oral implantation, the implant deviation in each step is still inconclusively in the stage of research and debate. The purpose of this paper is to summarize the advantages and disadvantages, research progress, accuracy and influencing factors of computer-guided oral implantation, aiming to provide a reference for improving implant accuracy and guiding clinical design and surgery.
Objective To analyze the current state, evaluate the accuracy, and determine the influencing factors of diabetes-related subscriptions on the WeChat platform. Methods The top 100 WeChat platforms on the "China WeChat Platform New Rank Annual List 2020" were searched using the term "diabetes". We identified diabetes-related subscriptions published from June 1, 2021 to August 31, 2021. The accuracy of subscriptions was analyzed according to the consistency with clinical practice guidelines, and was independently assessed by two specialists. SPSS 22.0 software was used for data analysis. Results Sixty-eight subscriptions from 26 WeChat platforms were included. Twenty-five (36.8%) subscriptions were evaluated as inconsistent. The numbers of "wow" per thousand reads and "like" per thousand reads of inconsistent diabetic subscriptions were statistically higher than those of consistent diabetic subscriptions (P<0.05). Subscriptions with expert support (80.8% vs. 52.4%) and evidence support (91.7% vs. 57.1%) shared a higher consistency (P<0.05). Subscriptions with commercial promotion (16.7% vs. 67.7%) had a lower consistency (P=0.02). Conclusion Although some content is inconsistent with guidelines, diabetes-related subscriptions have a certain dissemination ability on the WeChat platform. Moreover, readers are more likely to "wow" or "like" for inconsistent subscriptions. Diabetes-related subscriptions on the WeChat public platform need supervision and can be further regulated by providing evidence support and regulating commercial promotion.
The Standards for reporting diagnostic accuracy studies (STARD) 2015 is a revision of the STARD 2003 on the checklist and flow chart, on the basis of the new evidences of potential bias and applicability, to better guide the application of diagnostic test in clinical practices. Currently, the interpretation and application in China is still based on STARD 2003. This review will describe the application status of the original version and introduce the updated standards for reporting diagnostic accuracy studies.
Objective To investigate the development and appl ication of the computer aided surgery systems in the joint surgery field. Methods The l iteratures were extensively reviewed to analysis the usefulness of current active, semi-active and passive computer aided surgery systems in solving the cl inical problems of joint surgery. Results Several computer aided surgery systems have met the high technique demands, such as the precision of anatomical position and orientation, the accuracy of normal l imb al ignment restoration, the optimum of instrumentation control in arthroplasty, peri-articular osteotomy and minimally invasive procedure. Conclusion Computer aided joint surgery systems facil itate precise surgical techniques to achieve ideal operative outcome.
By comparing the diagnostic accuracy of two or more tests in the same study, the one with the higher diagnostic accuracy can be screened. Therefore, it is extremely important to conduct the comparative diagnostic test accuracy study. This paper introduced the concept of the comparative diagnostic test accuracy study, compared it with single diagnostic test accuracy study, and described its role, study design, statistical analysis, current status, and challenges.
Objective To analyze the current state, evaluate the accuracy, and determine the influencing factors of hypertension-related subscriptions from official health WeChat accounts. Methods The 36 official health WeChat accounts on the WeChat official accounts monthly list │ September 2022 China WeChat Top 500·New Rank certification were searched using the term "hypertension". We identified diabetes-related subscriptions published from April 1, 2022 to September 30, 2022. The accuracy of subscriptions was analyzed according to the consistency with clinical practice guidelines and was independently assessed by two specialists. SPSS 22.0 software was used for data analysis. Results One hundred and one subscriptions from 36 official health WeChat accounts were included. Forty-seven (46.5%) subscriptions were evaluated as consistent, seven (6.9%) subscriptions were evaluated as inconsistent, and forty-seven (46.5%) subscriptions were evaluated as unconfirmed. The differences between the numbers of reads, "wow" and "like" per thousand reads, were statistically significant. Consistency rates were higher for tweets backed by evidence and experts, and for tweets posted by public figures with the accreditation type "government". Conclusion Hypertension tweets have a good audience base, some of the content is inconsistent with current clinical guideline recommendations, and readers have little ability to screen them. There is a need to develop and improve the review mechanism for writing and publishing hypertension tweets on WeChat.
Objective To compare and evaluate the sensitivity, specificity, accuracy, negative and positive predictive values, negative and positive likelihood ratios of colposcopically directed biopsy and diagnostic cone biopsy in patients with cervical intraepithelial neoplasia. Methods We searched PubMed, CBMdisc, CMCC, CNKI, and VIP to March 2004, and Cochrane Library (Issue 4, 2003). Related journals published from 1970 to 2003 and unpublished papers were hansearched. Diagnostic studies which employed colposcopically directed biopsy or diagnostic cone biopsy and compared with golden standard (pathological diagnosis of specimens obtained through therapeutic conization or hysterectomy) were included and meta-analysis was performed. Participants were clinically suspected of pre-cancerous cervical lesions. Quality of studies was assessed, and SROC curve by Diagnostic and Screening Group of the Cochrane Collaboration was used to perform meta-analysis. Parameters were sensitivity, specificity, accuracy, predictive values, and likelihood ratio. Results Twenty six studies (3 376 patients ranging from 2 to 604 patients/per study) met the inclusion criteria. The quality of studies was generally poor.Before sensitivity analysis, superiority of diagnostic cone biopsy (sensitivity and specificity: 0.83) was shown over colposcopically directed biopsy (sensitivity and specificity: 0.76) (P<0.001); while after sensitivity analysis the results reversed (sensitivity of diagnostic cone biopsy was 0.58 and its specificity was 0.61; sensitivity and specificity of colposcopically directed biopsy increased to 0.84) (Plt;0.001). Conclusions No definite conclusioncan be drawn as to which method is superior. To make further analysis, more studies with high quality are needed.
Objective To elaborate on the statistical analysis methods for evaluating the accuracy of imaging diagnostic tests in a multiple-reader multiple-case (MRMC) design through formula derivation and real cases. Methods This study consisted of two parts: theoretical derivation and a real case study. The theoretical part discussed in detail the principles and procedures of MRMC statistical analysis methods, particularly the Obuchowski-Rockette (OR) and Dorfman-Berbaum-Metz (DBM) methods. The real case included 100 subjects, of whom 67 had disease. Four readers interpreted all the cases based on both traditional film imaging methods and digital imaging methods. OR and DBM methods were employed for data analysis. Results The real case showed that the OR and DBM methods had a high degree of consistency, with only slight differences in the confidence intervals. Conclusion It is recommended to use the OR and DBM methods for the statistical analysis of imaging diagnostic test accuracy, ensuring that the impact of reader factors on the evaluation results is fully considered. The results from the OR and DBM methods are relatively similar; when applying these methods in practice, one should consider the specific characteristics of the data and the research design to choose the appropriate analysis method. Besides, there are still challenges when applying the OR and DBM methods, such as software implementation and missing data handling, which require further exploration.
It is a challenge for clinicians and diagnostic systematic reviewers to determine the best test in clinical diagnosis and screening. Meanwhile, it also becomes the new chance and challenge for diagnostic test meta-analysis. Network meta-analysis has been commonly used in intervention systematic reviews, which can compare the effect size of all available interventions and to choose the best intervention. Network meta-analysis of diagnostic test can be defined as comparing all available diagnostic technologies in the same conditions based on the common reference tests. In order to provide the guide for diagnostic systematic reviewers, we aims to introduce four methods of conducting diagnostic test accuracy network meta-analysis, and to explore two ranking methods of network meta-analysis of diagnostic test accuracy.
Objective To evaluate the accuracy of the related parameters measured by spinal virtual surgery system (SVSS) three-dimensional (3D) techniques by comparing with the parameters measured by multi-spiral CT (MSCT) workstation. Methods Seven vertebrae specimens of adult men were scanned with MSCT, and the messages were sent toMSCT workstation and SVSS. The 3D image of spine was reconstructed by using volume rendering and multi-planar reformation; based on the parameter requirement of lower cervical pedicle fixation, 10 related parameters were measured. Then SPSS11.0 analyzer software was used to analyze the parameters measured by 2 systems. Between June 2009 and March 2010, 6 patients who received screw insertion in lower cervical spines were given MSCT scanning, then the messages were sent to SVSS 3D reconstruction to evaluate the situation and to collect the parameters of pedicle screw insertion. Results SVSS measurement showed that 1 pedicle was clausura (C3) and the diameters of 4 pedicles in coronal view were lee than 3 mm (C4 in 1, C5 in 2, C6 in 1), which did not fit for screw insertion; the results were similar to those by MSCT measurement. A total of 66 lower cervical pedicle were measured successfully. Significant differences were found in 14 parameters as follows between 2 systems (P lt; 0.05): the left pedicle height of C3, the both sides pedicle width of C4, the right pedicle spongy width of C4, the left X-direction entrance of C6, the both sides Y-direction entrance of C3, total pedicle length of sagittal view in both sides pedicle of C3 and the left pedicle of C5, total pedicle length of axial view in C3 pedicles, the left pedicle of C5, and the right pedicle of C6. There was no significantdifference in the other parameters (P gt; 0.05). In 6 cl inical cases, 34 screws were inserted, the postoperative MSCT scanning showed that 30 screws were placed successfully. The rate of accuracy was 88.24%. According to the Richter’s perforation classification, perforation at grade I and at grade II occurred in 2 cases (5.88%), respectively. Conclusion The accuracy of the parameters measured by SVSS is similar to that by MSCT.