ObjectiveTo preliminarily investigate morghological changes of rabbits reshaping ear cartilage assisted by microdissection needle and explore feasibility of new therapy for ear deformity.MethodsThe bilateral ears of 5 male New Zealand rabbits (aged, 5-6 months) were fixed maintaining the curvature and randomly divided into 2 groups (5 ears in each group). The ears were stimulated by microdissection needle in experimental group and were not treated with stimulation in control group. The skin reaction in the experimental group was observed immediately and at 4 weeks after stimulation. Then, the fixtures were removed at 4 weeks, and the shapes of the ears were observed. The cartilages were harvested from the ears to examined morphological changes after HE staining, and measured the chondrocyte layer thickness.ResultsAll rabbits survived until the end of the experiment. The skin has healed completely after 4 weeks in experimental group. After removing fixtures, the ears in the two groups all maintained certain forms momentarily; while 24 hours later, the ears in the control group mostly recovered original form, and the ears in the experimental group still maintained certain molding form until 8 weeks. HE staining showed there were smooth cartilage and uniform distribution of cells in the control group; the matrix staining was basically consistent; and the skin was normal appearance with epidermis, dermis, and cartilage of normal aspect. But the proliferation of chondrocyte with more layers of cells were observed in the experimental group. In addition, there were degeneration and injury of cartilage cells and connective tissue with necrotic cells and inflammatory cells at needle insertion sites. The chondrocyte layer thickness was (385.714±2.027) μm in the control group and (1 594.732±1.872) μm in the experimental group, there was significant difference between the two groups (t=–759.059, P=0.000).ConclusionRabbit ear cartilage can be effectively reshaped by microdissection needle. Proliferation of chondrocyte and changes in matrix can be found during the reshaping process.
ObjectiveTo explore the clinical application of the comprehensive guidance technologies, such as cone beam computed tomography (CBCT), virtual bronchoscopic navigation (VBN), and superimposed high-frequency jet ventilator for respiratory control in the biopsy of peripheral pulmonary nodules (PPNs). MethodsThe clinical information of 3 patients with PPNs diagnosed by CBCT combined with VBN and superimposed high frequency superposition jet ventilator in Shanghai Changhai Hospital were retrospectively analyzed. Results Clinical data of 3 patients were collected. The average diameter of PPNs was (25.3±0.3) mm with various locations in left and right lung. The first nodule was located in the apex of the left upper lung, and the biopsy was benign without malignant cells. The lesion was not enlarged during the 5-year follow-up. The second one was located in the left lingual lung, and the postoperative pathology was confirmed as mucosa-associated lymphoma. The third one was located in the anterior segment of the right upper lung. After the failure of endobronchial procedure, percutaneous PPNs biopsy under CBCT combined with VBN was performed, and the pathological diagnosis was confirmed as primary lung adenocarcinoma. Postoperative pneumothorax complication occurred in the third patient with right lung compression rate approximately 20%. ConclusionsThe application of CBCT, combined with VBN and the superimposed high frequency jet ventilator for respiratory control can potentially improve the accuracy and safety in the diagnosis of PPNs. Multi-center clinical trials are needed to verify its further clinical application.
Obstractive To observe the clinical effects and safety of endobronchial electrocautery treatment for tracheobronchial obstructive lesions in inoperable tracheobronchial squamous cell carcinoma.Methods Ninety-five patients with advanced and inoperable tracheobronchial squamous cell carcinoma were included. Thirty-four patients with central airway obstruction were treated with endobronchial electrocautery plus chemotherapy ( group A) and 61 patients without central airway obstruction were treated with chemotherapy alone ( group B) . The chemotherapy consisted of cisplatin or carboplatin, plus another thirdgeneration chemotherapy agent. Results In groug A, there were mean improvements in FEV1 of 41. 1% and in peak expiratory flow( PEF) of 65. 6% . There was no significant difference in the survival rates of the patients with and without central airway obstruction. Median survival time of group A was 11. 3 months and those of group B was 11. 6 months. 3, 6, and 12-month survival rates in group A were 87% , 68% and 39% respectively, and those in group B were 93% , 76% , and 45% respectively. Conclusion Endobronchial electrocautery is an effective and safe approach for inoperable tracheobronchial obstructive malignancies with few complications.
Objective To investigate the hot topics of research on evidence-based medicine in 2002. Method To search MEDLINE for papers on evidence-based medicine published in 2002, identify high-frequency subject headings related to research on evidence-based medicine, and cluster the high-frequency subject headings according to rates they appeared in common papers. Results 545 papers, 1 554 subject headings, 30 high-frequency subject headings on evidence-based medicine, and nine clustering categories of high-frequency subject headings were identified through search. Conclusions Both high-frequency subject headings and their clustering categories suggested that “evidence-based practice guidelines and their innovation”, “evidence-based health research and health policy”, “methodology on systematic reviews and randomized clinical trials”, “method of evidence-based decision making and its application in various subjects”, were the hot topics of evidence-based medicine. They provided useful references for Chinese medical professionals to practice evidence-based medicine.
Objective To explore the change of EEG waveform recorded by clinical EEG under different filtering parameters. Methods22 abnormal EEG samples of epilepsy patients with abundant abnormal waveforms recorded in Peking University first hospital were selected as the case group (abnormal group), and 30 normal EEG samples of healthy people with matched sex and age were selected as the control group (normal group). Visual examination and power spectrum analysis were then performed to compare the difference of wave forms and spectrum power under different settings of filter parameter between the two groups. ResultsThe results of visual examination show that, lower high-frequency filtering has an effect on the fast wave composition of EEG and may distort and reduce the spike wave. Higher low-frequency filtering has an effect on the overall background and slow wave activity of EEG and may change the amplitude morphology of some slow waves. The results of power spectrum analysis show that, Compare the difference between the EEG normal group and the abnormal group, the main difference under the settings of 0.5~70Hz was on the θ and α3 frequency band, different brain regions were slightly different. In the central region, the difference in the high frequency band (α3, γ1, γ2) decreases or disappears with the decrease of the high frequency filtering. In the rest of the brain, the difference in the δ band appears gradually with the increase of the low frequency filtering. Compare the difference between frontal area and occipital area under different filter set, for the normal group, under the settings of 0.5 ~ 70 Hz, the difference between two regions is mainly on the θ, γ1 and γ2 band. When high frequency filter reduces, the difference between two regions on high frequency band (γ1, γ2) are gradually reduced or disappeared. And when low frequency filter increases, the difference on δ band appears. For the abnormal group, the difference between frontal and occipital region under the settings of 0.5 ~ 70 Hz is mainly on γ1 and γ2 bands. When the high-frequency filter decreases, the difference between two regions on high-frequency bands are gradually decreased or disappeared. All the results can be corrected by FDR. ConclusionThe results show that the filter setting has a significant influence on EEG results. In clinical application, we should strictly set 0.5 ~ 70 Hz bandpass filtering as the standard.