ObjectiveTo compared the macular blood flow parameters among myopic choroidal neovascularization (mCNV), high myopia (HM) and normal subjects.MethodsRetrospective study. Forty patients (40 eyes) diagnosed as mCNV (mCNV group) in the Eye Hospital of Wenzhou Medical University at Hangzhou from June 2016 to November 2018, age-matched, sex-matched and diopter-matched 40 HM patients (40 eyes, HM group), age-matched and sex-matched 40 healthy persons (40 eyes, normal group) were enrolled in this study. Retina superficial and deep vessel density, the area of foveal avascular zone (FAZ), a-circularity index (AI) and vessel density around the 300 μm width of the FAZ region (FD) on macular 3 mm×3 mm scan on OCTA of 3 groups were compared.ResultsThere were significant differences in the average retina superficial, deep vessel density, the area of FAZ, AI and FD among 3 groups (F=24.82, 9.18, 3.58, 7.68, 14.15; P<0.05). The average retina superficial and deep vessel density and FD in mCNV group were lower than those in HM group (P<0.05). The average retina superficial and deep vessel density and FD in HM group were lower than those in control group (P<0.05). The average area of FAZ in mCNV group was smaller than that in control group (P<0.05). The average AI in mCNV group was less than that in the other 2 groups (P<0.05).ConclusionsThe retina superficial, deep vessel density and FD decreased, the area and the form of FAZ remained unchanged in HM subjects comparing with normal subjects. While retina superficial, deep vessel density and FD decreased more, the area of FAZ reduced, the form of FAZ tend to be irregular in mCNV.
Objective To observe the therapeutic effect of pars plana vitrectomy (PPV) on myopic traction maculopathy (MTM).Methods The clinical data of 31 eyes of 29 patients with MTM diagnosed by timedomain optical coherence tomography (TDOCT) and slitlamp ophthalmoscopy were retrospectively analyzed. The cases were divided into 2 groups according to the stage of MTM: 12 eyes of 10 patients at the early stage of MTM were in group 1; 19 eyes of patients at the most Advanced stage of MTM were in group 2. All of these eyes had undergone PPV with 10%15% inert gas filling. The patients were followed postoperatively for 6 to 12 months with the average of 8 months, and the best corrected visual acuity, reattachment of macular and retina was examined. Results The improvement rate of visual acuity after surgery for 6 months was 100% in group 1, and 63.2% in group 2 had (12/19); the visual acuity in group 1 was apparently better than that in group 2 (Z=-5477, P=0000). The macular hole disappeared without exposure of the pigment epithelium in all eyes of Group 1, but only 3 eyes in Group 2. For Group 2 patients, 3 eyes had reattached retina with macular holes, and 3 eyes had detached retina with macular holes. The recovery of macular configuration in Group 1 was obviously better than that in Group 2 (Z=-4318, P=0000). Conclusion The surgical intervention of MTM before the formation of macular hole and retinal detachment may prevent the formation of macular holes.
ObjectiveTo observe the clinical efficacy of digital 3D heads-up display viewing system (3D viewing system) and intraoperative OCT (iOCT) in vitrectomy for myopic foveoschisis (MF).MethodsA retrospective, consecutive case series. From October 2018 to May 2019, Nineteen eyes of 19 consecutive patients with MF diagnosed in Xiamen Eye Center of Xiamen University who underwent vitrectomy were included in this study. There were 7 males and 12 females, with the mean age of 54.47±11.38 years. The average axial length was 30.40±2.30 mm, the mean logMAR BCVA was 0.56±0.31, the mean central foveal thickness (CFT) was 317.80±151.9.32 μm, the mean max retinal thickness (maxRT) was 556.7±143.7 μm. All the surgeries performed combined with 3D viewing system with iOCT. The standard 25G pars planar vitrectomy were performed with removing the posterior vitreous and indocyanine green (ICG) staining of internal limiting membrane (ILM) and air-fluid exchange. Thirteen of 19 eyes underwent fovea-sparing ILM peeling and the other 6 eyes not. The average follow-up was 4.2±1.4 months. All the patients were on regular follow-up to document the changes on BCVA, anatomical changes in macula, CFT and maxRT. Paired t test was used to compare BCVA, CFT and maxRT before and after surgery.ResultsThe fine images of macula were clearly shown on the 3D viewing system in all eyes. The electronic green filter enhanced the contrast sensitivity of ICG stained images. Clear images of macula were captured by iOCT in all eyes. The average surgical time was 35.5±8.2 min. On the last follow-up, 16 of 19 eyes with MF resolved. The mean CFT was 178.5±103.5 μm, the maxRT was 341.8±83.8.16 μm, and the mean logMAR BCVA was 0.35±0.22. The differences of CFT, maxRT and logMAR BCVA before and after surgery were statistically significant (t=4.181, 7.154, 5.129; P<0.001). Minimal invisible full thickness macular hole were detected in 2 eyes by iOCT and repaired with auto serum or ILM flap covering. There was no complication associated with the 3D viewing system.Conclusions3D viewing system provides improved contrast and crystal clear macular image stain with ICG in pathological myopia. iOCT can detect the minimal invisible full thickness macular hole during surgery. Both may contribute to improved MF closure rate and BCVA.