west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "超声检查" 116 results
  • 视网膜母细胞瘤的彩色多普勒超声诊断分析

    Release date:2016-09-02 06:11 Export PDF Favorites Scan
  • Multiple factor analysis of intraorbital hemodynamic results in diabetic retinopathy

    Objective To determine the affected factors of intraorbital hemodynamic results in diabetic retinopathy (DR) and the risk factors related to the occurrence of DR. Methods Posterior ciliary artery (PCA), central retinal artery (CRA), central retinal vein (CRV), and vortex vein (VV) of 68 patients with DR were measured by color Doppler flow image (CDFI). Thirty-one hemodynamic parameters, including systolic velocity, diastolic velocity, mean velocity, resistive index, pulsatility index and accelerative velocity of ophthalmic artery (OA), and other variates (blood pressure, blood sugar, gender, age, duration of the disease, and so on) were collected and clustered in a principal components analys is following a forward, stepwise logistic regression on these components. Results Nine principal components were extracted from 37 original variates, reflecting the velocity of OA, velocity of PCA, resistance of OA, velocity of CRA,resistance of CRA, resistance of PCA, time-related factor, venous drainage factor and gender factor, respectively. In the result of logistic regression, resistance of OA, velocity of CRA, resistance of PCA, time-related factor, and venous drainage factor were the risk factors related to DR. Conclusion The first risk factor affecting DR is time, and intraorbital hemodynamic abnormity influencing the development of diabetic retinopathy may be the increase of resistance of OA, decrease of velocity of CRA, decrease of resistance of PCA, and increase of venous drainage. (Chin J Ocul Fundus Dis,2004,20:98-100)

    Release date:2016-09-02 05:58 Export PDF Favorites Scan
  • 超声生物显微镜在睫状体及其相关疾病检查中的应用

    睫状体位于虹膜后,是常规眼科方法检查的ldquo;盲区rdquo;,由于它的隐蔽位置,使睫状体及其相关 疾病的临床检查和诊断十分困难。超声生物显微镜检查(ultrasound biomicroscopy,UBM)采用高频超声波作为检测能源,可穿过透明组织和非透明组织。因此,UBM不但能观察到虹膜表面的形态,还能观察到后房及虹膜后组织的情况,其令人满意的分辨力和清晰度,为临床检查睫状体的形态、位置以及病变提供了良好的工具。现对UBM在睫状体及其相关疾病检查中的应用及其临床意义作一综述。(中华眼底病杂志,2002,18:79-81)

    Release date:2016-09-02 06:01 Export PDF Favorites Scan
  • Ultrasound biomicroscopy in 34 cases of iris and ciliary tumor

    Objective To probe the significance of application of ultrasound biomicroscopy (UBM) in the diagnosis and management of the iris and ciliary tumors. Methods UBM (Mode 840, Humphrey, 50 MHz 5 mm×5 mm) was done in 34 cases (35 eyes) of iris and ciliary body tumors, and some of the affected eyes underwent B-scan or Doppler ultrasound and CT scan. Histopathological examination of the resected tumor tissues was performed in 21 eyes of the operation. Results Among this series of 35 eyes with iris and ciliary body tumors detected by UBM, the characteristics of locality and solidity of the tumors, i,e., anterior chamber in plantation cyst, cyst behind the iris, and solid tumors of iris and ciliary body, of 21 eyes undergone surgical treatment revealed the same results both in UBM and histopathological examinations. Conclusion UBM can supply precise informations in diagnosis and treatment of tumors of iris and ciliary body. (Chin J Ocul Fundus Dis, 2002, 18: 128-130)

    Release date:2016-09-02 06:01 Export PDF Favorites Scan
  • Imaging findings of cystic liver lesions

    Objective To summarize ultrasonography, CT and (or) MRI imaging features of cystic liver lesions so as to improve its diagnostic accuracy. Methods The literatures relevant imaging studies of different types of cystic liver lesions at home and abroad were searched. Then with the etiology as clue, the imaging fetures of ultrasonography, CT and (or) MRI plain scan and enhancement scan were summarized. Results The cystic liver lesions had many types, their imaging findings were different and existed overlaps. The diagnosis and differential diagnosis of atypical cases were difficult. ① For the simple hepatic cyst, it was a round cystic mass with water-like echo, density and signal. The boundary was clear, and there was no separation in the cyst, without contrast enhancement. The sensitivity and specificity of diagnosing were higher by ultrasonography and MRI as compared with CT. ② For the bile duct hamartoma and Caroli diease, they were manifested as multiple cysts, widely distributed in the whole liver, without enhancement for the most lesions. The multiple cystic lesions without communicating with the bile duct was the key sign of differential diagnosis for these two dieases. ③ Enhancing mural nodules were more common in cystadenocarcinoma than cystadenoma. The accurate diagnosis of biliary cystadenoma depended on combination of ultrasonography, CT, and MRI findings. ④ For the cystic liver metastatic tumor, it was multiple cystic neoplasms in the liver parenchyma or around the liver. CT was the main method for the diagnosis, and which showed that the density was lower than that of the liver parenchyma, peripheral ring-enhanced lesion as enhanced scan. It was easy to distinguish with simple hepatic cyst by MRI. ⑤ For the cystic hepatocellular carcinoma, it presented as a multilocular cystic solid tumor. The presence of tumor thrombus in portal vein could help to the diagnosis. ⑥ For the undifferentiated embryonal sarcoma, CT plain scan showed the cystic low density mass with clear boundary, the edge with calcification, enhanced scan showed that the soft tissue composition presented continuous strengthening sign. There was no specific signal in MRI plain scan, and the periphery of the tumor was slowly strengthening. ⑦ For the liver abscess, it was easy to diagnose because it had different characteristic features in different pathological phase, but it was misdiagnosis of intrahepatic cholangiocarcinoma when its symptoms were atypical. ⑧ The ultrasonography and the CT were the optimal methods for the hepatic cystic echinococcosis and the hepatic alveolar echinococcosis respectively. The significances of imaging were to determine the activity of hydatid cyst and to identify anatomy structure among alveolar echinococcosis, bile duct and blood vessel, and judge invasion or not, MRCP was important for diagnosis. Conclusions Abdominal ultrasonography could be used as the first choice for diagnosis of cystic liver lesions, CT and MRI could be used as effective supplementary methods for it. A combination of various imaging techniques is key to diagnosis. Moreover, number and morphology of lesion, and solid component or not are important imaging features of diagnosis and differential diagnosis of cystic liver lesion.

    Release date:2017-05-04 02:26 Export PDF Favorites Scan
  • 彩色多普勒超声在胆囊小隆起性病变中的诊断价值

    目的 评价彩色多普勒超声在胆囊小隆起性病变中的诊断价值。 方法 2003年3月-2008年7月收治56例胆囊小隆起性病变患者,其中胆固醇息肉35例,胆囊炎性息肉8例,腺瘤7例,腺肌增生症4例,胆囊癌2例,观察病灶二维图像及彩血流分布及血流频谱特征,均经手术、病理证实。 结果 胆囊息肉常多发,基底窄或有蒂,CDFI不或很少显示血流信号。腺瘤单发为主,基底较宽或有蒂,CDFI不或很少显示血流信号;腺肌增生症(局限型)单发,基底较宽,CDFI不显示血流信号;胆囊癌基底宽,CDFI显示丰富血流信号,多普勒频谱呈低阻动脉频谱。 结论 彩色多普勒超声结合传统二维声像图对胆囊小隆起性病变有较高的诊断价值。

    Release date:2016-09-08 09:47 Export PDF Favorites Scan
  • Application of electrical impedance tomography on positive end-expiratory pressure setting in patients with acute respiratory distress syndrome

    Objective To explore the clinical application value of electrical impedance tomography (EIT) individualized adjustment of positive end-expiratory pressure (PEEP) in patients with acute respiratory distress syndrome (ARDS). Methods The ARDS patients requiring mechanical ventilation who admitted between April 2019 and March 2022 were recruited in the study. They were randomly divided into 3 groups with 12 cases in each group. Optimal PEEP was set using ARDSnet method (a control group), lung ultrasound scoring method (LUS group) and EIT adjustment method (EIT group). The changes of hemodynamics, blood gas analysis, respiratory mechanics, extravascular lung water index and other indicators of the patients were recorded at each time point. Results There was no significant difference in PEEP between the EIT group and the LUS group, but PEEP in both the EIT group and the LUS group was significantly higher than the control group (P<0.05). After 12 hours of treatment, the dynamic lung compliance of the control group did not change significantly, while the dynamic lung compliance ventilation of the LUS group and the EIT group was significantly improved for 12 hours, and the improvement in the EIT group was significantly better than that in the control group (P<0.05). After treatment, the oxygenation index in the three groups was significantly increased, and the oxygenation index in the EIT group was significantly higher than that in the control group (P<0.05). There was no significant difference in hemodynamics between the three groups before and after treatment (P>0.05). The extravascular lung water index of the three groups after treatment was significantly decreased, and the LUS group and the EIT group decreased more significantly than the control group (P<0.05). Conclusion In the PEEP setting of ARDS patients, the use of EIT personalized adjustment method can effectively improve the patient’s lung compliance and oxygenation index, and reduce extravascular lung water, without affecting hemodynamics.

    Release date:2023-05-26 05:38 Export PDF Favorites Scan
  • Application of Contrast-Enhanced Ultrasonography in Differential Diagnosis of Retroperitoneal Occupying Lesions

     Objective To evaluate the real-time contrast-enhanced ultrasonography (CEUS) in the differential diagnosis of retroperitoneal occupying lesions.  Methods Thirty patients with retroperitoneal occupying lesions, including 10 benign and 20 malignant lesions, were performed with CEUS, thus describing the perfusion of contrast agent, the entering style of contrast agent and the vascular morphous. And the entering styles were divided into two patterns: peripheral type or central type while the vascular morphous were divided into 4 levels: level 0, level 1, level 2 and level 3. All of these were compared between benign and malignant lesions. Compared the results of diagnosis malignant lesions by common ultrasonography with CEUS.  Results 1/5 case of benign substantive lesions presented as contrast agent perfusion defect, and 11/20 cases of substantive malignant lesions presented as contrast agent perfusion defect. 14/20 of malignant lesions were central type; 9/10 of benign lesions were peripheral type (P=0.005 2). In benign lesions, level 0 had 7/10, level 1 had 2/10 and level 3 had 1/10. In malignant lesions, level 0 had 1/20, level 1 had 3/20, level 2 had 8/20 and level 3 had 8/20, too (P=0.000 5). The rate of missed diagnosis was 40.00% and the accuracy was 66.67% by common ultrasonography, while the rate of missed diagnosis was 10.00% and the accuracy was 86.67% by CEUS combined with the entering style of contrast agent and the vascular morphous.  Conclusion The CEUS applies a new way to discriminate malignant from benign in retroperitoneal occupying lesions.

    Release date:2016-09-08 10:57 Export PDF Favorites Scan
  • Effectiveness comparison between ultrasound-guided and C-arm-guided in closed reduction and pinning for treatment of metacarpophalangeal fractures

    Objective To compare the effectiveness between ultrasound-guided and C-arm-guided in closed reduction and pinning for the treatment of metacarpophalangeal fractures. Methods The clinical data of 30 patients with metacarpophalangeal fractures between October 2015 and November 2016 were retrospectively analyzed. According to different treatments, the patients were divided into ultrasound group (using ultrasound-guided closed reduction and pinning, n=15) and C-arm group (using C-arm-guided closed reduction and pinning, n=15). There was no significant difference in gender, age, disease duration, causes of injury, injured finger, location of injury finger, fracture classification between 2 groups (P>0.05). The status and success rate of reduction were compared (excellent, good, and acceptable grades could be regarded as the successful reduction). The operation time, intraoperative fluoroscopy times, and fracture healing time were recorded. And the postoperative functional recovery was evaluated according to the total active movement (TAM) by the standard functional evaluation issued by Hand Surgery Association of Chinese Medical Association. Results The operation time of ultrasound group was longer than C-arm group, and the intraoperative fluoroscopy times was less than C-arm group, all showing significant differences (P<0.05). There was no signifi cant difference in the grade and the success rate of reduction between 2 groups (P>0.05). All the patients were followed up 6-18 months (mean, 10 months), without malunion, joint stiffness, tendon adhesions, and other complications. There was also no significant difference in the fracture healing time, the grade of TAM, and the excellent and good rate of TAM between 2 groups (P>0.05). Conclusion The treatment of ultrasound-guided closed reduction and pinning for metacarpophalangeal fractures is effective, which is a feasible auxiliary method of closed reduction and fixation for fracture. And less fluoroscopy can reduce the radiation damage of operation.

    Release date:2017-10-10 03:58 Export PDF Favorites Scan
  • 永存性原始玻璃体增生症影像学诊断

    Release date:2016-09-02 06:08 Export PDF Favorites Scan
12 pages Previous 1 2 3 ... 12 Next

Format

Content