With the development of surgical technology and the need of clinical, transesophageal echocardiography is more and more favored by clinicians. Although the transesophageal echocardiography has developed more than 20 years, yet it has not been widely used in operation at present in domestic. In addition, its application in surgery of children is more rare. It has been confirmed that intraoperative use of transesophageal echocardiography has good safety and wide range of application. We will summarize indications, complications, and the progress of the current technology from the scope of transesophageal echocardiography in pediatric surgery.
Currently, transcatheter intervention has emerged as a first-line treatment for coarctation of the aortic. Due to the radiation exposure associated with catheter interventional therapy, there are numerous restrictions, which harms both patients and medical personnel and is dependent on sizable radiation apparatus. Here, we report for the first time a case of echo-guiding percutaneous aortic stent implantation for a 27 years female patient of reproductive age. After discharge, the patient's aortic coarctation pressure decreased to 18 mm Hg, and the surgical results were satisfactory.
【摘要】随着超声心动图的普及与发展,无症状性类风湿性关节炎心脏瓣膜改变的检出率逐渐增多。临床应重视类风湿性关节炎心脏瓣膜损害以及超声心动图在这类疾病中的诊断价值,以期改善患者预后。【Abstract】 Objective More and more cardiac valve changes are detected in asymptomatic patients with rheumatoid arthritis by echocardiography. It is essential to pay attention to the clinical features of heart valves damage and the diagnostic value of echocardiography on that in order to improve the prognosis of patients.
ObjectiveTo explore the value of transthoracic echocardiography (TTE) to monitor and evaluate aortic insufficiency (AI) within one year after the implantation of the left ventricular assist device (LVAD).MethodsWe retrospectively collected and analyzed the TTE data of 12 patients who received LVAD implantation from 2018 to 2020 in our hospital. All patients were males, with an average age of 43.3±8.6 years. We analyzed temporal changes in the aortic annulus (AA), aortic sinus (AoS), ascending aorta (AAo), the severity of AI and the opening of aortic valve before operation and 1 month, 3 months, 6 months and 12 months after LVAD implantation.ResultsAll 12 patients survived within 1 year after LVAD implantation. One patient was bridged to heart transplantation 6 months after implantation, and two patients did not receive TTE after 3 and 6 months. Compared to pre-implantation, AoS increased at 1 month after implantation (31.58±5.09 mm vs. 33.83±4.69 mm). The inner diameters of AA, AoS and AAo increased at 3, 6 and 12 months after LVAD implantation compared to pre-implantation (P<0.05), but all were within the normal range except for one patient whose AoS slightly increased before operation. After LVAD pump speed was adjusted, the opening of aortic valve improved. The severity of AI increased at 6 and 12 months after LVAD implantation compared to pre-implantation, and increased at 12 months compared to 6 months after LVAD implantation (P<0.05).ConclusionTTE can evaluate aortic regurgitation before and after LVAD implantation and monitor the optimization and adjustment of LVAD pump function, which has a positive impact on the prognosis after LVAD implantation.
Abstract: Right ventricular dysfunction or right heart failure is a complex clinical syndrome and often leads to a poor prognosis and high mortality. In order to detect right ventricular dysfunction at an early stage, provide a therapy guidance and evaluate treatment outcomes, right ventricular function evaluation has aroused more and more concern in clinical physicians. With the advantages of being non-invasive, accuracy and repetitiveness, echocardiography is used extensively in the assessment of heart function. In this review, we focus on how to use echocardiography to evaluate right ventricular function easily, efficiently, accurately and sensitively, and provide a good foundation for its further clinical application.
Objective To introduce the application of transcatheter closure of multi-fenestrated atrial septal defect (ASD) via femoral vein under ultrasound guidance with amplatzer cribriform occluder (ACO) and atrial septal defect occluder (ASDO), as well as to assess its feasibility, effectiveness and safety. Methods The clinical data of 48 patients with fenestrated ASD occluded via femoral vein under ultrasound guidance from December 2015 to May 2018 in our hospital were retrospectively analyzed, including 17 males and 31 females, aged 10 months to 51 years, an average of 11.50±13.86 years, and weighting 6-79 (27.00±20.14) kg. Among 48 patients with fenestrated ASD, 12 patients had double-foramen and 13 atrial septal aneurysm combined with defects and 23 multi-foramen. All patients underwent transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE) to complete the closure of fenestrated ASD. Ultrasound, electrocardiogram and chest X-ray were reviewed the next day after surgery to evaluate the curative effect. Results Forty-eight patients with ASD were treated with 49 occluders, due to one patient with two occluders. There were 29 ASDO (8-26 mm) and 20 ACO (18-34 mm). During the operation, TTE/TEE examination showed that 48 patients were completely occluded, 13 patients showed fine bundle shunt in the unreleased push notification rod, and 9 patients had fine bundle shunt after the release of push notification rod. Fine bundle shunt was found in 8 patients 24 hours after operation, and microshunt was found in 3 patients 1 year after operation. All the patients were followed up. The occluder position was good. The right heart was reduced in different degrees, and the X-ray showed that the pulmonary blood was reduced in different degrees. No arrhythmia was found by electrocardiogram after operation. Conclusion It is a safe and effective method to use ACO and ASDO to occlude ASD through femoral approach under ultrasound guidance.
Echocardiography is an important imaging technique in transcatheter edge-to-edge mithal valve repair (TEER). During the operation, mitral leaflets capture and clamping have the highest requirements for ultrasound image quality and should be performed under the guidance of high-quality commissural view. However, standard commissural view cannot be obtained in some patients due to cardiac enlargement, transposition or limited esophageal acoustic window. In this condition, the optimal view can be obtained by Multivue technology. This paper reports a case of successful mitral valve TEER under the real-time guidance of Multivue technology, and summarizes the key points of this technology.