west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "起搏器" 19 results
  • An optimized segmentation of main vessel in coronary angiography images via removing the overlapping pacemaker

    Coronary angiography (CAG) as a typical imaging modality for the diagnosis of coronary diseases hasbeen widely employed in clinical practices. For CAG-based computer-aided diagnosis systems, accurate vessel segmentation plays a fundamental role. However, patients with bradycardia usually have a pacemaker which frequently interferes the vessel segmentation. In this case, the segmentation of vessels will be hard. To mitigate interferences of pacemakers and then extract main vessels more effectively in CAG images, we propose an approach. At first, a pseudo CAG (pCAG) image is generated through a part of a CAG sequence, in which the pacemaker exists. Then, a local feature descriptor is employed to register the relative location of pacemaker between the pCAG image and the target CAG image. Finally, combining the registration result and segmentation results of main vessels and pacemaker, interferences of pacemaker are removed and the segmentation of main vessels is improved. The proposed method is evaluated based on 11 CAG images with pacemakers acquired in clinical practices. An optimization ratio of the Dice coefficient is 12.04%, which demonstrates that our method can remove overlapping pacemakers and achieve the improvement of main vessel segmentation in CAG images.Our method can further become a helpful component in a CAG-based computer-aided diagnosis system, improving its diagnosis accuracy and efficiency.

    Release date:2022-12-28 01:34 Export PDF Favorites Scan
  • Rehabilitation experience of intraoperative temporary epicardial pacing lead implantation after cardiopulmonary bypass

    目的 探讨心脏外科体外循环术后留置心外膜临时起搏导线的康复经验。 方法 选取 2015 年 9 月至 2016 年 4 月 69 例体外循环术后留置心外膜临时起搏导线患者,其中男 26 例、女 43 例,平均年龄(50.2±11.5)岁。予术前及术后干预措施、出院指导和随访,评价康复效果。 结果 患者术后平均住院时间(9.8±2.6)d,69 例患者均顺利出院,其中 57 例患者顺利拔除心外膜临时起搏器导线,1 例患者因Ⅲ度房室传导阻滞继续留置临时起搏器电极,11 例患者残留临时起搏导线出院,出院后两周随访发现 2 例患者的临时起搏导线体内残端露出体表。 结论 心外膜临时起搏电极是心脏外科术后常见的风险防范手段之一,掌握临时起搏器导线的管理及临时起搏器应用的相关知识,合理管理能有效地降低术后并发症的发生,可促进患者术后康复。做好患者宣教,避免因沟通不畅导致的医患纠纷发生。

    Release date:2017-04-01 08:56 Export PDF Favorites Scan
  • Comparison of 1-year clinical results of transcatheter aortic valve replacement (TAVR) using prostheses with two different frame designs in 124 patients in a single center

    ObjectiveTo compare and analyze the clinical effects of two kinds of frame design valves after transcatheter aortic valve replacement (TAVR).MethodsWe retrospectively reviewed 124 patients who underwent TAVR and were followed up for 1 year. There were 71 males and 53 females aged 75.57±6.21 years. These patients were treated with Venus-A or Edwards Sapien aortic valves. The hemodynamics and cardiac function of these two kinds of transcatheter aortic valves (THV) were evaluated by echocardiography. The 30-day mortality and 1-year clinical effect of the patients were calculated.ResultsEight-one patients used Venus-A valve and 43 patients used Edwards Sapien valve. The aortic valve transaortic pressure gradient was reduced and the rate of perivalvular leakage was low (both 2.6%) in both groups, and there was no statistical difference between the two groups. The implantation rate of permanent pacemaker was 17.3% and 11.6%, respectively. The 1-month survival (94.0% and 93.0%) and 1-year survival (94.0% and 91.0%) rates were not statistically different.ConclusionThe two groups of THV with different stent structures have good short-term clinical effect and low implantation rate of permanent pacemaker.

    Release date:2021-07-28 10:22 Export PDF Favorites Scan
  • RESEARCH PROGRESS IN CARDIAC BIOLOGICAL PACEMAKER CREATED BY CELL TRANSPLANTATION

    Objective To review the current status and problems in developing cardiac biological pacemaker(CBP) by cell transplantation. Methods The l iterature over the past decade concerning CBP constructed through celltransplantation was reviewed and summarized. Results Experiments in vivo testified that the cell transplantation was feasible for CBP construction, and the transplantation of sinus atrial node cell and stem cell was still the predominant method for constructing CBP. However, such problems as difficult ampl ification of transferred cardio muscle cell, low success rate of CBP construction as well as unstable function of CBP make it lag behind the tremendous cl inical demands. The gene transfection technology might be one of the approaches to resolve these issues. Conclusion As one feasible method for CBP construction, the cell transplantation has a bright future in the cl inical appl ication and is worthy of further study.

    Release date:2016-09-01 09:17 Export PDF Favorites Scan
  • A comparative study of X-ray projection doses during leadless pacemaker and conventional single chamber ventricular pacemaker implantation

    ObjectiveTo compare the X-ray projection doses during leadless pacemaker implantation and conventional single chamber ventricular pacemaker (VVI) implantation. MethodsThis study included all patients who underwent leadless pacemaker implantation and VVI pacemaker implantation performed by the same principal investigator team using the same digital subtraction angiography (DSA) machine in the West China Hospital of Sichuan University from August 3rd, 2018 to February 18th, 2020. Among the enrolled patients, 27 who underwent leadless pacemaker implantation were included in the case group, whereas 38 who underwent conventional VVI implantation were included in the control group. Data regarding the intraoperative dose area product (DAP), air kerma (AK), duration of X-ray fluoroscopy, number of exposed sequences on the film, total number of frames on the film, operation time, and BMI were collected to investigate the causes of the differences. ResultsThe case group received a higher X-ray projection dose than the control group, and there were statistically significant differences between the two groups in terms of DAP, AK, duration of X-ray fluoroscopy, the number of exposed sequences on the film, the total number of frames on the film, and operation time (P<0.05). ConclusionPatients who underwent leadless pacemaker implantation are exposed to more radiation than those who underwent conventional VVI implantation.

    Release date:2022-10-25 02:19 Export PDF Favorites Scan
  • Surgical Treatment of Cardiac Complications Caused by Permanent Pacemaker Implantation

    Objective To investigate clinical features and treatment strategy of cardiac complications caused by permanent pacemaker (PPM) implantation.?Methods?We retrospectively reviewed clinical records of 10 patients with cardiac complications caused by PPM who received surgical treatment in General Hospital of People’s Liberation Army from January 2003 to May 2010. There were seven males and three females with an average age of 62.9 years. One patient had an Atrial demand inhibited pacemaker (AAI) PPM and the other nine patients had a DDD PPM. Cardiac complications included infective endocarditis (IE) in 5 patients, tricuspid insufficiency (TI) in 4 patients and pulmonary artery thrombosis in one patient. According to their respective situation, these patients underwent different surgical treatment such as tricuspid valve plasty (TVP), tricuspid valve replacement and/or removal of PPM lead and vegetations as part of intensive debridement of the infected area.?Results?Postoperatively, all the patients were successfully discharged. Five patients whose PPM lines and leads were preserved in the surgery had normal PPM function. Three PPM-dependent patients whose PPM leads were removed in the surgery received a PPM reimplantation later. Nine patients were followed up for an average of 5.5 months and all these patients had a significantly improved quality of life. One patient after TVP had mild TI during follow-up. Conclusion Surgical treatment should be performed as early as possible when infection is too severeto control in patients with IE caused by PPM. PPM-induced TI may be hard to be diagnosed preoperatively, and transesophageal echocardiography or surgical exploration should be considered to establish the diagnosis. Measures should be taken to protect PPM if PPM lines and leads are preserved during operation. Patients whose PPM lines and leads are removed during the surgery need to choose a suitable time for PPM reimplantation.

    Release date:2016-08-30 05:50 Export PDF Favorites Scan
  • Long-term effect of modified Morrow surgery on hypertrophic obstructive cardiomyopathy in children: A retrospective study in a single center

    Objective To analyze the long-term outcome of modified Morrow surgery (interventricular septal cardiomyectomy) in the treatment of hypertrophic obstructive cardiomyopathy (HOCM) in children. Methods The clinical data of the children with HOCM (aged≤14 years) who underwent modified Morrow surgery from January 2010 to August 2022 in Guangdong Provincial People's Hospital were retrospectively analyzed, including changes in hospitalization status, perioperative period, and long-term 15-lead electrocardiogram and echocardiography. Results A total of 29 patients were collected, including 22 males and 7 females, aged 10.00 (5.00, 12.00) years. Five (17.9%) patients had New York Heart Association (NYHA) heart function grade Ⅲ or Ⅳ. Ventricular septal cardiomyectomy was performed in all patients. All 29 patients survived and their cardiac function recovered after operation. Before discharge, right bundle branch block was observed in 2 patients and left bundle branch block in 6 patients. After surgery, in the left ventricular septal cardiomyectomy, the left atrial diameter decreased (P<0.001), left ventricular end-systolic diameter increased (P=0.009), the peak pressure gradient of left ventricular outflow tract decreased (P<0.001), and the thickness of ventricular septum decreased (P<0.001). The systolic anterior motion of mitral valve disappeared and mitral regurgitent jet area decreased (P<0.001). The flow velocity and peak pressure gradient of right ventricular outflow tract also decreased in the patients who underwent right ventricular septal cardiomyectomy. The average follow-up of the patients was 69.03±10.60 months. All the patients survived with their NYHA cardiac function grading Ⅰ or Ⅱ. No new-onset arrythmia event was found. Echocardiography indicated that the peak pressure gradient of the left ventricular outflow tract remained low (P<0.001). Moderate mitral regurgitation occurred in 2 patients, and left ventricular outflow tract obstruction with moderate mitral regurgitation occurred in 1 patient after simple right ventricular septal cardiomyectomy. Conclusion Right ventricular or biventricular obstruction is frequent in the children with HOCM and they usually have more symptoms before surgery. Modified Morrow surgery can effectively relieve outflow tract obstruction and improve their cardiac function. The long-term outcome is satisfactory. However, the posterior wall of the left ventricle remains hypertrophic. Also, there is an increased risk of a conduction block.

    Release date:2024-06-26 01:25 Export PDF Favorites Scan
  • 安置永久性心脏起搏器患者应用经尿道前列腺电切术的安全性探讨

    目的探讨对安置永久性心脏起搏器患者应用经尿道前列腺电切术(TURP)的安全性。 方法回顾2005年1月-2013年1月12例安置永久性心脏起搏器前列腺增生症者的TURP治疗。患者年龄71~83岁,安置永久性心脏起搏器1~9年,其中病态窦房结综合征7例,Ⅲ度房室传导阻滞4例,3束支传导阻滞1例;起搏器类型为房室全能型9例,心房按需型2例,心室按需型1例。 结果患者手术过程顺利,术中生命体征平稳,术后恢复良好。 结论安置心脏起搏器的前列腺增生症患者经过充分准备可以承受TURP治疗。

    Release date: Export PDF Favorites Scan
  • New-onset conduction block after transcatheter aortic valve replacement: A retrospective analysis in a single center

    ObjectiveTo investigate the new-onset conduction block after transcatheter aortic valve replacement (TAVR) and summarize the relevant experience. Methods The perioperative data of TAVR patients in the Second Hospital of Hebei Medical University from January 2016 to February 2023 were collected, and the new-onset incidence of conduction block after TAVR was analyzed retrospectively. Results Finally 352 patients were included, including 225 males and 127 females, with an average age of (67.2±5.1) years, among whom 256 patients were treated with Venus-A valves, 69 patients with Vita-Flow valves, and 27 patients with J-Valve valves. There were 38 (10.8%) patients of new-onset postoperative block. There were 6 (1.7%) patients of new-onset postoperative grade Ⅲ atrioventricular block, including 5 (2.0%) patients of Venus-A and 1 (1.4%) patient of Vita-Flow. Conduction function was restored in 2 patients within 14 days after surgery, and failed to be restored in 4 patients, who then received permanent pacemaker implantation in the Department of Cardiology. There were 27 (7.7%) patients of new left bundle branch block after surgery, including 22 (8.6%) patients of Venus-A, 4 (5.8%) patients of Vita-Flow and 1 (3.7%) patient of J-Valve; and conduction function was restored within 7 days after surgery in 23 patients, and 5 (1.4%) patients developed new right bundle branch blocks after surgery including 4 (1.5%) patients of Venus-A and 1 (1.4%) patient of Vita-Flow. Conclusion New-onset conduction block is a common complication after TAVR, and the new-onset rate of left bundle branch block is the highest, followed by the grade Ⅲ atrioventricular block. Mastering reasonable methods and applying appropriate strategies can effectively reduce the new-onset rate of postoperative conduction block and improve the overall success rate of TAVR surgery.

    Release date:2025-02-28 06:45 Export PDF Favorites Scan
  • Influence of balloon post-dilatation on cardiac conduction in patients undergoing transcatheter aortic valve replacement: A retrospective cohort study

    ObjectiveTo analyze the impact of balloon post-dilation on cardiac conduction in patients undergoing transcatheter aortic valve replacement (TAVR). MethodsFrom June 2021 to December 2022, patients with severe aortic valve stenosis or regurgitation who underwent TAVR surgery using domestically produced valves at Xijing Hospital, Air Force Military Medical University were selected. The occurrence of intraoperative and postoperative cardiac conduction block was recorded. According to whether balloon post-dilation was performed during the surgery, patients were divided into the post-dilation group and the non-post-dilation group. The baseline data, postoperative cardiac conduction block occurrence, and cardiac function of the two groups were analyzed. ResultsA total of 126 patients were included, including 83 males and 43 females, with an average age of (66.6±7.6) years. There were 30 patients in the post-dilation group and 96 patients in the non-post-dilation group. On the first day after TAVR, the average QRS intervals in the post-dilation group and the non-post-dilation group were (105.6±13.8) ms and (125.9±28.2) ms, respectively (P=0.017). At discharge, the average PR intervals in the two groups were (168.7±36.8) ms and (192.1±44.2) ms, respectively (P=0.024). After TAVR, 9 (7.1%) patients developed new atrioventricular block, 5 (4.0%) patients developed new complete right bundle branch block, and 33 (26.2%) patients developed new complete left bundle branch block. During hospitalization, 2 (1.6%) patients received permanent cardiac pacemakers, both of whom were in the non-post-dilation group. There was no statistical difference in postoperative left ventricular structure and function between the two groups (P>0.05). ConclusionPostoperative expansion using domestically produced interventional valves for TAVR do not increase the incidence of early atrioventricular block and permanent cardiac pacemaker implantation after valve implantation, and there are no significant changes in cardiac structure and function in patients with conduction block in the short term after surgery.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content