Since 1979, vascularized iliac bone graft based on the deep circumflex iliac vessels (DCIV) or the deep superior branches of superior gluteal vassels (SGV) was used to the treatment of bone defect, non-union of fracture, and aseptic necrosis of the femoral head in Ⅱ4 cases. Of these Ⅱ4 graftings, 68 were pedicled, 46 were microvascular free transfer. Early callus formation developed 6 weeks after surgery. Solid bony union was obtained in 3 months. Among 32 patients with aseptic necrosis of femoral head followed more tha 1 years, dior relief of pain and omprovement of X-ray findings were obtained in 31. The advantages of using vascularized iliac bone graft, especially based on the DCIV and SGV, are discussed. The author has a good opinion of vascularized iliac bone graft based on the SGV.
The minimally invasive cardiovascular surgery developed rapidly in last decades. In order to promote the development of minimally invasive cardiovascular surgery in China, the Chinese Minimally Invasive Cardiovascular Surgery Committee (CMICS) has gradually standardized the collection and report of the data of Chinese minimally invasive cardiovascular surgery since its establishment. The total operation volume of minimally invasive cardiovascular surgery in China has achieved substantial growth with a remarkable popularization of concepts of minimally invasive medicine in 2019. The data of Chinese minimally invasive cardiovascular surgery in 2019 was reported as a paper for the first time, which may provide reference to cardiovascular surgeons and related professionals.
目的 评价股浅静脉瓣膜环形缩窄术治疗原发性下肢深静脉瓣膜功能不全(primary deep venous insufficiency,PDVI)的疗效和应用价值。方法 2002年4月至2006年4月期间经顺行性静脉造影加Valsalva试验证实为PDVI者119例(158条),其中2002年4月至2004年1月收治者仅行大隐静脉高位结扎剥脱+交通支结扎术(前期治疗组),2004年2月至2006年4月收治者在前期治疗方法的基础上加行股浅静脉瓣膜环形缩窄术(后期治疗组),以CEAP(clinical,etiologic,anatomic,and pathophysiologic)临床分级与临床记分评价2组的疗效。结果 2组患者术后临床分级及临床记分均明显下降(前期治疗组由5.9±3.6降至2.1±1.3,P<0.01; 后期治疗组由6.4±3.5降至1.7±1.8,P<0.01),且后期治疗组较前期治疗组下降程度更大(P<0.01)。结论 股浅静脉瓣膜环形缩窄术有助于PDVI患者临床症状缓解,因此术前明确诊断为PDVI的患者,应行股浅静脉瓣膜环形缩窄手术。
Objective To introduce a novel approach using parallel placement of another oxygenator in the recirculation line as oxygen supply for oxygenator failure without circulatory arrest in cardiopulmonary bypass (CPB),and confirm its outcomes in an animal experiment. Methods A traditional piglet CPB model was established. Oxygenator failure model was established by reducing fraction of inspired oxygen (FiO2) from 80% to 21% after aortic cross-clamp and cardiac arrest in CPB. Another oxygenator was then parallel placed in the recirculation line to supply 100% oxygen.Dynamic changes in partial pressure of oxygen (PaO2),mixed venous oxygen saturation (SvO2),arterial oxygen saturation(SaO2) and blood pH of blood samples from the arterial perfusion duct were monitored with different blood flow of400 ml/min,800 ml/min and 1 100 ml/min. Results When FiO2 was reduced to 21%,PaO2 decreased to 64-67 mm Hg(P<0.001),SaO2 decreased significantly to 88%-90% (P<0.001),SvO2 decreased to 69%-72% (P<0.001),and blood pH decreased too,all indicating oxygenator failure. After parallel placement of another oxygenator in the recirculation line was performed,PaO2,SaO2 and SvO2 all significantly increased,as well as blood pH. When the blood flow in the recirculation line achieved 33% or above of overall arterial perfusion flow,clinical oxygen demand was generally satisfied. Conclusion Parallel placement of another oxygenator in the recirculation line may be utilized as a treatment strategy for oxygenator failure without circulatory arrest and changeover of failed oxygenator.
Facing the increasing cardiovascular disease burden and prevailing population risk factors, the cardiovascular surgery in China was also encountering challenges including imbalances in discipline development, significant divergencies in healthcare quality, lacking of clinical guidelines and domestic critical evidence. The concept of quality control and improvement has been practiced and tested in many disease specialties. Quality improvement programs are urgently needed in China to promote the universal cardiovascular surgery healthcare quality.
The incidence of cardiovascular disease remains high, and surgery is an important measure for the treatment of cardiovascular disease. However, cardiovascular surgery is complicated and difficult, and it is one of the departments with the highest rate of allogeneic blood transfusion. Allogeneic blood transfusion significantly increases the complications and mortality of patients, while autologous blood transfusion can effectively reduce allogeneic blood transfusion and adverse reactions. Autologous plateletpheresis technology is a popular autotransfusion method in recent years. This article reviews the autologous plateletpheresis technology and its clinical application in cardiovascular surgery.
目的交流腹主动脉瘤的诊断和外科治疗方法。方法对1991年2月至2002年7月我院外科治疗的30例肾下型腹主动脉瘤的临床资料进行回顾性分析。结果数字减影血管造影术诊断1例,MRI诊断2例,其余27例均经CT确诊。该30例中,腹主动脉瘤破裂6例,行急诊手术,死亡2例(死亡率33.3%); 24例未破裂者中, 22例行腹主动脉瘤切除和原位人造血管移植术,术后死亡2例(死亡率9.1%),另2例行腹主动脉瘤腔内人造血管移植术。结论及早术前诊断,恰当地选择手术时机、手术方式及正确的围手术期处理是提高手术成功率,减少术后并发症和死亡率的关键。
The cardiovascular surgery in China has reached a stable platform, with notable progress been achieved in the past several decades. However, significant divergency regarding the healthcare quality was also observed, which requiring effective intervention to start the transition from the focus on "quantity" to the pursuit of "quality". Quality improvement program, including the establishment of a national cardiovascular surgery database, the conformation of a standard key quality evaluation indicator system, and the conduction of quality intervention and improvement initiatives, are promising to consolidate and expand the advantages of cardiac surgery and lead to better patient outcomes.