Objective To compare the long-term results of vascularised fibulargraft and simple autologous fibular graft for reconstruction of wrist after distal bone tumor resection.Methods From January 1979 to September2002, 15 patients with wrist defects due to distal bone tumor resection were treated with vascularised fibular graft or simple autologous fibular graft and followed up 1 year. The results were graded with Enneking’s system and evaluated radiographicallyaccording to the “International Symposium on Limb Salvage”. The grade system included limb function, radiological examination and the function of ankle. Results The limb function of 8 patients with vascularised fibular graft restored to 80% of normal function and the bone union was achieved within 6 months. The limbfunction of 6 patients with simple autologous fibular graft restored to 67% of normal function. The bony union was achieved within 6 months in 4 cases with thebone graft less than 5 cm and in the 13th and 16th months in 2 cases with the bone graft more than 12 cm. Conclusion It is suitable to use the headof fibular boneas a substitute for the distal radius. The healing of vascularised fibular graft is very quick and haven’t the bone resorption. So in the procedure for reconstruction and limb salvage after bone tumor resection of distal radius, the free vascularised fibular graft with fibular head is an ideal substitute.
Objective To summarize the research progress of the artificial wrist joint prosthesis. Methods Domestic and abroad literature concerning artificial wrist joint prosthesis was reviewed and analyzed thoroughly. Results Artificial wrist joint prosthesis has been developed to the 4th generation. The artificial wrist joint arthroplasty has advantages of pain relief and functional improvement and can achieve ideal short-term effectiveness. But there are some problems, such as loosening, subsidence, fracture, and dislocation of prosthesis. The long-term effectiveness of the 3rd and 4th generation prosthesis still need to be followed up. Conclusion The biomechanics of wrist joint is extremely complicated, which results in less application and slow development of artificial wrist joint prosthesis. Early-term effectiveness of artificial wrist joint arthroplasty is basically satisfactory, but there are still some long-term complications. So the artificial wrist joint prosthesis remains to be developed.
Objective To investigate a new operative method to reconstruct wrist joint for treating the defect of the distal radius after excision of tumor.Methods From October 1999 to December 2001, 3 cases of giant cell tumor in the distal radius were resected and the wrist joint was reconstructed by transplanting the fibular head pedicled with the lateral inferior genicular artery. ResultsAfter followed up for 6 to 18 months, all patients achieved the bony healing within 4 months without tumor relapse and had good function of the wrist joint. Conclusion This operation is simple and reliable. The fibularhead can be cut according to the tumor size of the radius.
ObjectiveTo summarize the effectiveness of nitinol memory alloy two foot fixator with autologous cancellous bone grafting in treating old scaphoid fracture and nonunion.MethodsBetween January 2013 and January 2017, 11 patients of old scaphoid fracture and nonunion were treated with nitinol memory alloy two foot fixator and autologous cancellous bone grafting. All patients were male with an average age of 26.1 years (range, 18-42 years). The fractures were caused by sport in 3 cases, falling in 7 cases, and a crashing object in 1 case. The interval between injury and operation was 6-18 months (mean, 8.9 months). Postoperative outcome measures included operation time, fracture healing time, grip strength, range of motion (ROM) of flexion, extension, ulnar deviation, and radial deviation, Mayo score, visual analogue scale (VAS) score, and the Disabilities of the Arm, Shoulder, and Hand (DASH) score.ResultsThe operation time was 35-63 minutes (mean, 48 minutes). All incisions had primary healing with no infection and loosening or breakage of internal fixator. All patients were followed up 12-30 months (mean, 20.7 months). X-ray films showed that fracture healing was achieved in all patients with an average time of 15 weeks (range, 12-25 weeks). All internal fixators were removed after 10-12 months of operation (mean, 11.2 months). At last follow-up, the grip strength, ROMs of flexion, ulnar deviation, and radial deviation were superior to those before operation (P<0.05), no significant difference was found in ROM of extension between pre- and post-operation (t=0.229, P=0.824). There were significant differences in above indexes between affected and normal sides (P<0.05). At last follow-up, the Mayo, VAS, DASH scores were also significantly superior to those before operation (P<0.05).ConclusionFor the old scaphoid fracture and nonunion, Ni-Ti arched shape-memory alloy fixator and autologous cancellous bone grafting can obtain good effectiveness, which is an effective treatment.
Objective To investigate the long-term effectiveness of Ni-Ti memory alloy tripod fixator in the treatment of Kienböck disease. Methods The clinical data of 22 patients with Kienböck disease who were treated with Ni-Ti memory alloy tripod fixator between January 2011 and September 2013 and followed up more than 10 years was retrospectively analyzed. There were 14 males and 8 females with an average age of 45 years (range, 20-64 years). The Lichtman staging was stage Ⅲb. According to AO/Association for the Study of Internal Fixation (AO/ASIF) classification, there were 6 cases of type B1, 2 cases of type B2, 10 cases of type B3, and 4 cases of type C2. The disease duration ranged from 18 to 50 months, with an average of 30.7 months. The operation time, intraoperative blood loss, and complications were recorded. Wrist height ratio and scapholunate angle were measured by wrist anteroposterior and lateral X-ray films before and after operation. The grip strength of bilateral hands was measured by Jamar dynamometer. The wrist pain was evaluated by visual analogue scale (VAS) score, and the wrist function was evaluated by Mayo score, and the radial deviation, ulnar deviation, dorsiflexion, and palmar flexion range of motion of wrist were measured. Results The operation time was 45-60 minutes, with an average of 52.21 minutes; the intraoperative blood loss was 50-60 mL, with an average of 58.63 mL. No nerve or blood vessel injury occurred during operation. All patients were followed up 10-13 years (mean, 11.3 years). X-ray films at 3 months after operation showed that the density of lunate bone was lower than that before operation. Satisfactory fusion of the scapho-trapezio-trapezoeid joint was achieved at 3-6 months after operation (mean, 4.5 months), and the wrist height ratio and the scapholunate angle after fusion significantly improved when compared with those before operation (P<0.05). Wrist pain relieved, scaphoid rotation and dislocation improved, and no radiocarpal joint degeneration was found during follow-up, and no internal fixator loosening, breakage, or lunate bone necrosis occurred. At last follow-up, the wrist radial deviation, ulnar deviation, dorsiflexion, and palmar flexion range of motion, VAS score, and grip strength of the affected side significantly improved when compared with those before operation (P<0.05); the grip strength of the affected side recovered to 99.00%±1.25% of the healthy side. Mayo score ranged from 72 to 93, with an average of 85; 14 cases were rated as excellent, 5 good, and 3 satisfactory, the excellent and good rate was 86.4%. ConclusionIn the treatment of stage Ⅲb Kienböck’s disease, the scapho-trapezio-trapezoeid joint usion using Ni-Ti memory alloy tripod fixator can effectively reduce pain, improve hand function, and prevent further deterioration, and achieve good long-term effectiveness.
Objective To report the clinical experience of using Ilizarov wrist joint distraction technique in the treatment of a case of rheumatoid arthritis of the wrist. Methods In January 2019, a 49-year-old female patient with rheumatoid arthritis of the left wrist, complicated by ulnar impaction syndrome, was admitted for treatment. Preoperatively, the active range of motion of the left wrist was as follows: extension 0°-flexion 0°, pronation 65°-supination 35°, and grip strength of 4.0 kg. The visual analogue scale (VAS) score was 9, and the Cooney wrist function score was 15, indicating poor function. As conservative treatment failed to achieve symptom relief, Ilizarov wrist joint distraction surgery was performed. Postoperatively, joint distraction was applied at 2 mm increments on postoperative days 2 and 7, in 4 separate sessions. Results Postoperative X-ray film examination at 7 days revealed a distraction of 3.6 mm in the affected wrist joint compared to the contralateral side. The external fixator was removed 2.5 months postoperatively. At 22 months postoperatively, X-ray film and MRI examinations revealed that the joint space of the left wrist had returned to near-normal, with significant reduction in joint effusion and synovial proliferation. The active range of motion of the left wrist improved to extension 15°- flexion 30°, pronation 90°-supination 90°, with a grip strength of 18.0 kg. The wrist pain VAS score decreased to 0, and the Cooney wrist function score improved to 90, indicating excellent function. At 50 months postoperatively, follow-up X-ray film, MRI, and functional assessments showed the results similar to those at 22 months. Conclusion Ilizarov wrist joint distraction may be a viable treatment option for rheumatoid arthritis of the wrist.
Since 1985, on the basis of anatomical observation of 50 fresh adult specimens, we designed the transposition oF vascularized capitate bone carrying the dorsal branche of the anteriot interosses artery to replace the damaged lunate bone from avascular necrosis. The operation had been done in 6 patients and the follow-up observation (from 6 months to 4 years) showed that the operation was satisfactory. The anatomic basis, the advantages and disadvantages, and the surgical indications were discussed.
OBJECTIVE This paper is aimed to observe the long-term result of reconstruction of wrist joint by replacing distal end of radius with vascularized fibular head in patient of giant tumor. METHODS From July 1978 to November 1993, 12 cases of giant tumor of distal end of radius were treated by this procedure and followed up for 6 months to 15 years, and the movement range of wrist, grip strength, and pain were evaluated. RESULTS The painful wrist released in 11 cases, only one case still existed mild pain and felt discomfortable. The average range of movement of wrist joint was 34.05 degree in volar flexion, 52.80 degree in dorsal extension, 26.25 degree in ulnar deviation, and 19.75 degree in radial deviation, and average grip strength was 44.6 kg. Compared with the contralateral side, there were accounted for 46.2%, 72.7%, 76.1%, 80.6%, and 76.7% respectively. CONCLUSION Replacement of distal end of radius with fibular head to reconstruct wrist joint can restore function of carpal joint, which is proved to be a safe and effective method.