west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "脊柱骨折" 21 results
  • Mid-term Efficacy of the Technique of Minimally Invasive Pedicle Screw Fixation on Thoracolumbar Burst Fracture

    目的 评价微创椎弓根钉内固定技术治疗胸腰椎爆裂骨折的中期临床疗效。 方法 2002年9月-2007年9月,采用微创椎弓根钉内固定技术治疗胸腰椎爆裂骨折30例。其中男16例,女14例;年龄18~65岁,平均39.8岁。骨折节段:胸11者3例, 胸12者13例, 腰1者12例, 腰者22例。所有骨折按AO分型,均为A3型。受伤至手术时间6 h~6 d,平均45 h。分析术后影像学指标、疼痛评分及功能障碍指数。 结果 患者均获随访,随访时间3~9年,平均5.2年。术后各时间点伤椎前缘高度及后凸Cobb角均较术前明显恢复(P<0.01)。术后伤椎高度随随访时间延长逐渐下降,后凸Cobb角逐渐增大。取出内固定物后、术后2年、末次随访时动力位X线片上骨折椎体前后相对滑移距离分别为(1.9 ± 0.3)、(2.1 ± 0.2)、(2.1 ± 0.3)mm,两两比较差异无统计学意义(P>0.05)。术后1、2年及末次随访时疼痛视觉模拟评分分别为(2.5 ± 1.2)、(2.5 ± 1.1)、(2.4 ± 1.3)分,两两比较差异无统计学意义(P>0.05)。末次随访时Denis腰痛分级:P1级13例,P2级12例,P3级5例。功能障碍指数为(11.4 ± 3.1)分,获优23例、良5例、可2例。 结论 单纯微创椎弓根钉内固定技术治疗胸腰椎爆裂骨折中期临床效果满意,脊柱稳定性良好。Objective To mid-term efficacy of the technique of minimally invasive pedicle screw fixation on thoracolumbar burst fracture. Methods From September 2002 to September 2007, 30 patients were treated with minimally invasive pedicle screw fixation for thoracolumbar fracture. There were 16 males and 14 females with the mean age of 39.8 years (range,18-65 years). The injured level of was T11 in 3 cases, T12 in 13 cases, L1 in 12 cases, and L2 in 2 cases. The type of thoracolumbar fractures of all the patients was A3 according to AO classification. The during from injury to operation was 6 hours to 6 days with an average of 45 hours. The index of image and pain and disability index were evaluated after operation. Results All patients were followed up for 3 to 9 years with the mean of 5.2 years. Their average sliding distance after operation for removing internal fixation was (1.9 ± 0.3), and (2.1 ± 0.2) mm 2 years after the operation and (2.1 ± 0.3) mm at the latest follow-up. There was no significant difference (P>0.05). Their average score was (2.51 ± 1.2) 1 year after the operation, was (2.42 ± 1.1) 2 year after the operation, and was (2.36 ± 1.3) at the latest follow-up (P>0.05). According to Denis score system to evaluate index of lumbago, there was P1 in 13 cases, P2 in 12 cases, and P3 in 5 cases. The score of Oswestry Disability Index (ODI) was 11.4 ± 3.1 at the latest follow-up. Twenty-one cases gotexcellent therapeutic result, five cases got good and two were moderate. Conclusions Minimally invasive pedicle screw fixation for the treatment of thoracolumbar burst fracture provide satisfactory clinical results. The vertebral body and adjacent vertebral body have a good stability.

    Release date: Export PDF Favorites Scan
  • FAILURE AND PREVENTION OF RECONSTRUCTION IN ANTERIOR STABILITY OF SPINE BY DUAL BLADE PLATE

    Abstract Dual-blade plate is widely used in reconstruction of anterior stability of spine. Two hundred and ninety-eight cases were followed up since 1984. Among them, 181 cases were fractureof thoracolumbar spine; 63 cases were tuberculosis of thoracolumbar spine; 43 cases were tumor of thoracolumbar spine; 5 cases were spondylisthesis of lumbar spine; 2 cases were ankylosing spondylitis accompanied with gibbosity; 2 cases were adolescent vertebral epiphysis; I case was hemivertebra; I case was dysplasia of the first lumbar vertebra acompanied with gibbosity. Most cases were successful following operation, but in some cases, the results were unsuccessful, mainly due to the position of the dualblade plate in the vertebral body was not satisfactory. The mistakes most commonly occurred were one or two blades, or a part of the blade going into the intervertebral space, and less commonly seen was deviation of the dual -blade plate from itscorrect orientation or a little side-bent of the blade. Split of the vertebra and fall off of the dual-blade plate were happened in few cases. The causeswere analyzed and ways of prevention were provided in this article.

    Release date:2016-09-01 11:11 Export PDF Favorites Scan
  • ADVANCEMENT IN THE REPAIR AND RECONSTRUCTION OF THE INJURED SPINE ANDSPINAL CORD

    Objective To investigate the latest research and the therapeutic development in the injuries to the spine and spinal cord. Methods Literature concerned was reviewed, combined with our own research and clinical experience, to summarize the trend of the researches and their clinical application in the treatment of the injured spine and spinal cord.Results Theposterior approach atlantoaxial stabilization technique changed the conventional wiring technique into the transarticular screw fixation to the plate and pedicle or the lateral mass screw fixation technique. Theclinical application of the transoralpharyngeal atlantoaxial reduction plate fixation technique showed a good effect on the reduction of atlantoaxial dislocation. However, there were no unified criteria for selection of the surgical approach, fixation level, and fusion mode in the treatment of thoracolumbar spinalfractures. Under optimal conditions, both the anterior and the posterior approaches could achieve good clinical effects on decompression and spinal reconstruction. The single level fixation technique showed some advantages in treating certaintypes of thoracolumbar spinal fractures when compared with the traditional cross-sectional fixation. The endoscopy-assistant and image-guiding spinal intervention techniques were evolved in China during these years. In the treatment of the obstinate painful osteoporotic vertebral compressive fracture, percutaneous vertebroplasty and kyphoplasty achieved good results in the pain relief and spinal reconstruction. Numerous basic and clinical researches have given us a further understanding of the medical protection of acute spinal cord injury, and biological treatments have given us new ideas on neural reparation and regeneration. Cell transplantation and gene therapy have become the most promising treatment strategies in this field.Conclusion With the rapid development of spine surgery, the repair and reconstruction ofthe injured spine and spinal cord made a great stride in the recent years.

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • Bilateral percutaneous balloon kyphoplasty through unilateral transverse process-extrapedicular approach for osteoporotic vertebral compression fracture of lumbar

    ObjectiveTo evaluate the feasibility and short-term effectiveness of bilateral percutaneous balloon kyphoplasty through unilateral transverse process-extrapedicular approach for osteoporotic vertebral compression fracture (OVCF) of lumbar.MethodsA retrospective analysis was made on the clinical data of 93 patients with OVCF of lumbar who met the selection criteria between January 2018 and June 2019. According to the different surgical methods, they were divided into group A (44 cases, treated with bilateral percutaneous balloon kyphoplasty through unilateral transverse process-extrapedicular approach) and group B [49 cases, treated with percutaneous kyphoplasty (PKP) via bilateral transpedicle approach]. There was no significant difference in gender, age, body mass index, T value of bone mineral density, injury cause, fractured level, time from injury to operation, comorbidities, and preoperative Cobb angle of injured vertebra, visual analogue scale (VAS) score, and Oswestry disability index (ODI) between the two groups (P>0.05). The operation time, intraoperative fluoroscopy times, bone cement injection amount, and incidence of bone cement leakage were recorded and compared between the two groups; Cobb angle of the injured vertebrae, VAS score, and ODI were measured before operation, at 2 days and 1 year after operation. The contralateral distribution ratio of bone cement was calculated according to the anteroposterior X-ray film at 2 days after operation.ResultsThe operation time and the intraoperative fluoroscopy times in group A were significantly less than those in group B (P<0.05). There was no bone cement adverse reactions, cardiac and cerebrovascular adverse events, and no complications such as puncture needles erroneously inserted into the spinal canal and nerve injuries occurred in the two groups. Bone cement leakage occurred in 6 cases and 8 cases in groups A and B, respectively, all of which were asymptomatic paravertebral or intervertebral leakage, and no intraspinal leakage occurred; the bone cement injection amount and incidence of bone cement leakage between the two groups showed no significant differences (P>0.05). The contralateral distribution ratio of bone cement in group A was significantly lower than that in group B (t=2.685, P=0.009). Patients in both groups were followed up 12-20 months, with an average of 15.3 months. The Cobb angle of the injured vertebrae, VAS score, and ODI in the two groups were significantly improved at 2 days after operation, however, the Cobb angle of the injured vertebra at 1 year after operation was significantly lost when compared with the 2 days after operation, the VAS score and ODI at 1 year after operation were significantly further improved when compared with the 2 days after operation, the differences were all significant (P<0.05). There was no significant difference in the Cobb angle of the injured vertebrae, VAS score, and ODI between the two groups at each time point after operation (P>0.05).ConclusionBilateral percutaneous balloon kyphoplasty through unilateral transverse process-extrapedicular approach is comparable to bilateral PKP in short-term effectiveness with regard to fracture reduction, reduction maintenance, pain relief, and functional improvement. It has great advantages in reducing operation time and radiation exposure, although it is inferior in bone cement distribution.

    Release date:2021-08-30 02:26 Export PDF Favorites Scan
  • COMPARATIVE RESEARCH OF TRANSFORAMINAL LUMBAR INTERBODY FUSION AND POSTERIOR LATERALFUSION IN TREATMENT OF THORACOLUMBAR SPINE FRACTURE AND DISLOCATION

    Objective To compare the therapeutic effect of transforaminal lumbar interbody fusion (TLIF) and posterior lateral fusion (PLF) in treatment of thoracolumbar spine fracture and dislocation. Methods From January 2005 to July 2007, 35 patients (22 males, 13 females, aged 17-53 years old) with thoracolumbar spine fracture and dislocation (T11-L3) received posterior open reduction and pedicle nail-stick system internal fixation. Among which, 14 patients underwent TLIF(group TLIF), and the rest 21 patients underwent PLF (group PLF). According to AO classification, group TLIF had 3 cases of A3, 7 cases of B and 4 cases of C, while group PLF had 4 cases of A3, 10 cases of B and 7 cases of C. Based on American Spinal Injury Association (ASIA) Scoring Standard formulated in 2000, the motor score of group TLIF and group PLF was (50.6 ± 3.6) and (50.8 ± 4.2) points, respectively; and the sensory score was (170.5 ± 42.7) and (153.8 ± 23.7) points, respectively. No significant difference was noted between 2 groups in general information (P gt; 0.05). Results The operation time of group TLIF and group PLF was (316 ± 32) minutes and (254 ± 27) minutes, and the blood loss of group TLIF and group PLF was (487 ± 184) mL and (373 ± 72) mL, indicating there were significant differences between 2 groups (P lt; 0.05). Wounds of all patients were healed by first intention and there was no death, aggravation of neurological function impairment and compl ication of internal fixation instrument loosening and breaking. All 35 cases were followed up for 9-23 months with an average of 14.6 months. Postoperatively, the thoracolumbar bone fusion rate of group TLIF and group PLF was 100% and 85.7%, respectively, indicating there was a significant difference (P lt; 0.05). At 3 months after operation, the motor score of group TLIF and group PLF was increased by (10.4 ± 10.0) and (9.4 ± 9.3) points, respectively; and the sensory score was upgraded by (26.5 ± 22.8) and (28.8 ± 28.4) points, respectively, showing there were no significant difference (P gt; 0.05). At immediate moment, 3, 6 and 12 months after operation, the spine height restoration of group TLIF was (5.4 ± 2.1), (5.4 ± 1.9), (5.4 ± 1.4) and (5.3 ± 1.3) mm, respectively; while it was (5.3 ± 2.6), (5.3 ± 2.2), (4.8 ± 3.1) and (4.2 ± 3.6) mm for group PLF. Meanwhile, the Cobbangle recovery of group TLIF was (14.5 ± 3.5), (14.5 ± 3.6), (14.4 ± 3.4) and (14.4 ± 3.6)º, respectively; while it was (14.3 ± 2.7), (14.2 ± 3.1), (12.2 ± 2.8) and (11.7 ± 3.3)º for group PLF. Concerning the spine height restoration and the Cobb angle recovery, no significant difference was observed between 2 groups at immediate moment and 3 months after operation (P gt; 0.05), but significant differences were noted at 6 and 12 months after operation (P lt; 0.05). Conclusion For the treatment othoracolumbar spine fracture and dislocation, TLIF is superior to PLF in bony fusion and restoration of spine column height.

    Release date:2016-09-01 09:19 Export PDF Favorites Scan
  • Clinical Application of Percutaneous Vertebroplasty in Treatment of Senile Osteoporosis Spinal Compression Fractures

    目的 探讨经皮穿刺椎体成形术治疗老年性骨质疏松性椎体压缩骨折的临床疗效。 方法 2006年1月-2009年1月收治患者147例(214个椎体)脊柱骨折者,男56例,女91例;年龄61~80岁,平均69岁。脊柱骨折部位为T8~L3,其中胸椎98个,腰椎116个。采用C形X线机透视引导下于俯卧位或侧卧位进行经皮穿刺椎体成形术,注射聚甲基丙烯酸甲酯(PMMA,骨水泥)。测量并计算术前和术后椎体前/后缘高度比值,疗效评价按WHO标准。 结果 118例获随访,随访时间3~7个月,平均4个月。147例214个椎体均手术成功,骨水泥注射量1.0~8.0 mL/椎体。术后2~4 h疼痛开始缓解,无显著危害性并发症发生,术前和术后椎体前/后缘高度比值无显著性差异,118例随访3~7个月疗效评价按WHO标准完全缓解加部分缓解率为100%。 结论 经皮穿刺椎体成形术是一种治疗老年性骨质疏松性椎体压缩骨折的微创手术,能够有效缓解骨质疏松性椎体骨折引起的疼痛,维持椎体稳定性,恢复椎体的高度,是一种简单、安全、有效的方法。

    Release date:2016-09-08 09:49 Export PDF Favorites Scan
  • Clinical application of percutaneous pedicle screw placement guided by ultrasound volume navigation combined with X-ray fluoroscopy: a prospective randomized controlled study

    Objective To explore the feasibility and accuracy of ultrasound volume navigation (UVN) combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation through a prospective randomized controlled study. Methods Patients with thoracic and lumbar vertebral fractures scheduled for percutaneous pedicle screw fixation between January 2022 and January 2023 were enrolled. Among them, 60 patients met the selection criteria and were included in the study. There were 28 males and 32 females, with an average age of 49.5 years (range, 29-60 years). The cause of injury included 20 cases of traffic accidents, 21 cases of falls, 17 cases of slips, and 2 cases of heavy object impact. The interval from injury to hospital admission ranged from 1 to 5 days (mean, 1.57 days). The fracture located at T12 in 15 cases, L1 in 20 cases, L2 in 19 cases, and L3 in 6 cases. The study used each patient as their own control, randomly guiding pedicle screw implantation using UVN combined with X-ray fluoroscopy on one side of the vertebral body and the adjacent segment (trial group), while the other side was implanted under X-ray fluoroscopy (control group). A total of 4 screws and 2 rods were implanted in each patient. The implantation time and fluoroscopy frequency during implantation of each screw, angle deviation and distance deviation between actual and preoperative planned trajectory by imaging examination, and the occurrence of zygapophysial joint invasion were recorded. Results In terms of screw implantation time, fluoroscopy frequency, angle deviation, distance deviation, and incidence of zygapophysial joint invasion, the trial group showed superior results compared to the control group, and the differences were significant (P<0.05). Conclusion UVN combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation can yreduce screw implantation time, adjust dynamically, reduce operational difficulty, and reduce radiation damage.

    Release date:2023-10-11 10:17 Export PDF Favorites Scan
  • Curative effect of mini-incision common vertebral pedicle screw internal fixation on thoracoclumbar fractures without neurological injury

    Objective To explore the short-term therapeutic effect of mini-incision common vertebral pedicle screw internal fixation on thoracoclumbar fractures without neurological injury. Methods The data of 61 patients with thoracolumbar fractures without neurological injury treated with mini-incision common vertebral pedicle screw internal fixation (the mini-incision group, n=32) or percutaneous pedicle screw fixation (the percutaneous group, n=29) from February 2014 to January 2016 was retrospectively collected and analyzed. Total incision length, operation time, blood loss, fluoroscopy times, postoperative bed rest time, hospitalization costs, Visual Analogue Scale (VAS) score, Oswestry Disability Index (ODI), vertebral Cobb angle of correction, and accuracy rate of screw placement were compared between the two groups. Results All the patients were followed up for 6 to 24 months with a mean of 13.4 months. There were no complications such as incision infection and neurovascular injury except for 2 screws breakage in one patient in the percutaneous group. In the mini-incision group, the average total incision length was longer than that in the percutaneous group [(7.33±0.53) vs. (6.38±0.44) cm], while the average operation time was shorter than that in the percutaneous group [(62.66±4.75) vs. (72.93±5.09) minutes]; the differences were statistically significant (P<0.001). In the mini-incision group, the average frequency of fluoroscopy was fewer [(5.63±0.61)vs. (19.07±1.60) times] and the average hospitalization costs was lower [(23.3±1.5) thousand yuan vs. (39.5±1.6) thousand yuan] than those in the than that in the percutaneous group; the differences were statistically significant (P<0.001). No significant difference was found in blood loss, postoperative bed rest time, VAS score, ODI, vertebral Cobb angle of correction, and accuracy rate of screw placement between the two groups (P>0.05). Conclusions Mini-incision common vertebral pedicle screw internal fixation for thoracoclumbar fractures without neurological injury has the advantages of short operation time, less fluoroscopy times, low hospitalization costs and high fixation strength. It may obtain a good short-term effectiveness.

    Release date:2017-12-25 06:02 Export PDF Favorites Scan
  • THE CLINICAL EFFECT OF ANTIROTATION REDUCTION INTERAL FIXATOR ON THE TREATMENT OF FRESH THORACOLUMBAR SPINE FRACTURE

    Objective To evaluate the effect of self-designed antirotation reduction internal fixator(ARRIF) on treating different spine segment fracture.Methods From August 1999 to March 2003, 76 patients(48 males and 28 females, aged from 22 to 59 with an average of 34.1) with thoracolumbar fracture were operatively treated by ARRIF. The follow-up period ranged from 6 to 21 months(15 months in average). Classification according to injury segment: flexion compression racture 27 cases, burst fracture 42 cases, flexion distraction injury 3 cases, flexion revolving type fracture dislocation 2 cases, shear force type dislocation 2 cases. Classification according Frankel’s grade:A grade 16 cases, B grade 15 cases, C grade 27 cases, D grade 10 cases, E grade 8 cases.Operation duration, volume of bleeding, incidence postoperation complication and effect of reduction fixation were observed. Results The operation duration of ARRIF was 1.2 h in average, and there was about 200 ml volume of bleeding during operation. The nerve function showed one Frankel’s grade improvement after operation were as follows:A grade 8 cases(50%), B grade 11 cases (73.3%), C grade20 cases(74.1%), D grade 3 cases (30%); 2 Frankel’s E cases have no nerve function changes.The nerve function damage have no aggravation in all the patients,the postoperation Cobb’s angle was averagely corrected 22°. The horizontal displacement of dislocation vertebrae was averagely corrected 28% in sagittal plane, the statistical analysis had significant variance(Plt;0.01).ARRIF had no complications of the breakage of screws and rods. Conclusion ARRIF proves to be a valid internal fixator in reducing and fixing different thoracic lumbar segment spine fracture.

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • Application of Artificial Vertebral Body of Biomimetic NanoHydroxyapatite/Polyamide 66 Composite In Anterior Surgical Treatment of Thoracolumbar Fractures

    Objective To study the clinical effects of the artificial vertebral body of the biomimetic nanohydroxyapatite/polyamide 66 (nHA/PA66) compositefor the structural reconstruction and the height restoring of the vertebral body in the thoracolumbar fractures by the anterior surgical procedures. Methods From December 2003 to January 2006, 42 patients with thoracolumbar fractures received the anterior surgical procedures to decompress and reconstruct the spinal vertebral structure with the artificial vertebral body of the nHA/PA66 composite. Among the patients, there were 28 males and 14 females, aged 1767 years, averaged 43.6 years. The thoracolumbar fractures developed at T12 in 5 patients, at L1 in 17, at L2 in 14, and at L3 in 6. The height of the anterior border of thevertebral body amounted to 29%-47% of the vertebral body height, averaged 40.6%.The Cobb angle on the sagittal plane was 2138° averaged 27.6°. According tothe Frankel grading scale, the injuries to the nerves were as the following: Grade A in 7 patients, Grade B in 19, Grade C in 8, Grade D in 6, and Grade E in 2. Results All the 42 patients were followed up for 625 months. Among the patients, 36 were reconstructed almost based on the normal anatomic structure, and 6 were well reconstructed. The mean height of the anterior border of the vertebralbody was 40.6% of the vertebral body height before operation but 91.7% after operation. And the reconstructed height of the vertebra was maintained. The mean Cobb angle on the sagittal plane was 27.6°before operation but 13.4° after operation. All the patients had a recovery of the neurological function that had a 1grade or 2grade improvement except 7 patients who were still in Grade A and 2 patients who were in Grade D. The implant was fused 35 months after operation. No infection, nail break, bar/plate break or loosening of the internal fixation occurred. Conclusion The artificial vertebral body of the biomimetic nHA/PA66 composite can effectively restore the height and the structure of the vertebra, can be fused with the vertebral body to reconstruct the spinal structural stability effectively, and can be extensively used in the clinical practice.

    Release date:2016-09-01 09:20 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content