目的 比较克氏针张力带与锁骨钩钢板治疗RockwoodⅢ型肩锁关节脱位的临床疗效。 方法 1999年1月-2007年3月,收治肩锁关节脱位患者29例,分别采用克氏针张力带联合喙锁韧带重建(克氏针组10例)和锁骨钩钢板(钢板组19例)治疗。其中男18例,女11例;年龄19~50岁,平均38.2岁。患者均为新鲜RockwoodⅢ型肩锁关节脱位,受伤至手术时间1~16 d,平均3 d。两组患者性别、年龄、受伤至手术时间等一般资料比较差异无统计学意义(P>0.05)。进行两组患者术后临床及影像学评估比较。 结果 25例患者(克氏针组10例,钢板组15例)获随访,随访时间2~12年,平均6年。术后克氏针组发生克氏针弯曲5例、断裂1例;钢板组切口浅表感染2例,经换药后治愈,其余患者切口Ⅰ期愈合。两组患者肩锁关节均获得良好功能,组间比较差异无统计学意义(P>0.05)。影像学方面:与克氏针组相比,在患肢负重位时钢板组喙锁间隙间距增加了23%(P<0.05),非负重位两组间距差异无统计学意义(P>0.05)。术后8~12周出现喙锁韧带钙化,钢板组12例、克氏针组2例(P<0.05)。术后6个月出现肩锁关节骨性关节炎,钢板组2例、克氏针组1例(P>0.05)。肩关节功能与影像学结果无相关性(r=0.096,P>0.05)。 结论 克氏针张力带联合喙锁韧带重建和锁骨钩钢板固定治疗RockwoodⅢ型肩锁关节脱位均可获得良好的临床功能。与克氏针张力带相比,锁骨钩钢板固定具有手术操作简便、疗效确切、并发症少、能够早期康复锻炼等优点。
ObjectiveTo investigate the short-term effectiveness of arthroscopic assisted double Endobutton “8” buckle fixation in the treatment of Rockwood Ⅲ type acute acromioclavicular joint dislocation.MethodsThe clinical data of 12 patients with Rockwood Ⅲ type acute acromioclavicular joint dislocation who were treated with arthroscopic assisted double Endobutton “8” buckle fixation between June 2016 and June 2019 were analyzed retrospectively. There were 8 males and 4 females, with an average age of 47.0 years (range, 36-58 years). There were 4 cases of left shoulder and 8 cases of right shoulder. The causes of injury included traffic accident injury in 7 cases and falling injury in 5 cases. The average time from injury to operation was 5.0 days (range, 3-14 days). Before operation and at last follow-up, the shoulder joint activity was recorded; the improvements of function and pain were evaluated by Constant score and visual analogue scale (VAS) score, respectively; the reduction was evaluated by measuring the coracoid spacing of the affected side on the anteroposterior X-ray film of shoulder joint.ResultsAll 12 cases were followed up 6-36 months, with an average of 20.6 months. All the incisions healed by first intention. There was no complications such as clavicle and coracoid fractures and Endobuton displacement. At last follow-up, the range of motion of the abduction improved from preoperative (77.5±4.5)° to (162.5±6.5)°, the range of motion of forward flexion improved from (84.1±5.2)° to (169.5±5.8)°, the Constant score improved from 42.5±2.3 to 92.4±2.3, the VAS score improved from 5.4±0.8 to 0.6±0.5, and the coracoid spacing reduced from (20.5±1.4) mm to (9.2±0.6) mm, all showing significant differences (P<0.05).ConclusionArthroscopic assisted double Endobutton “8” buckle fixation for the treatment of Rockwood Ⅲ type acute acromioclavicular joint dislocation is safe, less invasive, and quicker recovery. It can effectively alleviate shoulder pain, significantly improve the mobility of the shoulder joint, and achieve good short-term effectiveness.
Objective To investigate arthroscopic treatment for acute acromioclavicular dislocation by using Twin Tail TightRope combined with distal joint capsular repair. Methods The clinical data of 40 patients with acromioclavicular dislocation treated between February 2016 and December 2017 were retrospectively analyzed. The patients were divided into arthroscopic group (20 cases, using arthroscopic Twin Tail TightRope combined with distal joint capsular repair for anatomical repair of stable structure of acromioclavicular joint) and control group (20 cases, treated with clavicular hook plate internal fixation) according to different surgical methods. There was no significant difference in gender, age, cause of injury, Rockwood classification, time from injury to operation, preoperative visual analogue scale (VAS) score and Constant score between the two groups (P>0.05), which were comparable. Postoperative VAS score and Constant score were used to assess shoulder function and re-dislocation was also observed. Results The incisions of the two groups healed by first intention, and no early postoperative complications occurred. All patients were followed up 12-18 months (mean, 13.5 months). Postoperative X-ray films showed good anatomical reduction in both groups, but the clavicular hook had a presense in the subacromial space in control group. All patients in arthroscopic group achieved satisfactory shoulder function and returned to work after operation; there was no obvious pain, no complications such as exposure of implant after operation, and no need to remove the implant. In the control group, 4 patients had obvious subacromial impingement pain after operation, and 1 patient had re-dislocation after removal of internal fixator at 1 year after operation; the rest had no complications related to internal fixation, and the internal fixators were removed at 1.0-1.5 years after operation, without re-dislocation. The VAS score and Constant score at 3 months and 1 year after operation in both groups significantly improved when compared with those before operation, and further improved at 1 year after operation (P<0.05). The VAS score and Constant score at 3 months and 1 year after operation in arthroscopic group were significantly better than those in control group (P<0.05). Conclusion Arthroscopic treatment for acute acromioclavicular joint dislocation by using Twin Tail TightRope combined with distal capsular repair is more effective than traditional incision surgery and can obtain more satisfactory results in patient compliance and function recovery because of minimally invasive surgery.