ObjectiveTo research the procedure for creating an animal model of mitral regurgitation by implanting a device through the apical artificial chordae tendineae, and to assess the stability and dependability of the device. MethodsTwelve large white swines were employed in the experiments. Through a tiny hole in the apex of the heart, the artificial chordae tendineae of the mitral valve was inserted under the guidance of transcardiac ultrasonography. Before, immediately after, and one and three months after surgery, cardiac ultrasonography signs were noted. Results All models were successfully established. During the operation and the follow-up, no swines died. Immediately after surgery, the mitral valve experienced moderate regurgitation. Compared with preoperation, there was a variable increase in the amount of regurgitation and the values of heart diameters at a 3-month follow-up (P<0.05). ConclusionIn off-pump, the technique of pulling the mitral valve leaflets with chordae tendineae implanted transapically under ultrasound guidance can stably and consistently create an animal model of mitral regurgitation.
ObjectiveTo evaluate the safety and efficacy of transapical mitral valve repair with moderate-to-severe or severe mitral regurgitation (MR) by using LifeClip system. Methods We retrospectively analyzed the clinical data of 7 symptomatic patients with moderate-to-severe or severe MR who received transapical mitral valve repair by using the LifeClip system in our hospital from July to November 2021. There were 5 males and 2 females with an average age of 76.0±7.5 years. ResultsThere were 2 patients with degenerative MR and 5 patients with functional MR. All of the procedures were successful and 6 patients received 1 LifeClip while the other one patient received 2. The operation time was 135.7±46.9 min, the mechanical ventilation time was 12 (3, 14) h, and the hospital stay time was 18.1±4.1 d. No serious complications or death occurred during the perioperative or follow-up period. MR reduction by ≥2 grades was achieved in all the patients at the one-month follow-up. The classification of cardiac function was improved in varying degrees. Conclusion Transapical mitral valve repair using the LifeClip system shows good safety and efficacy for severe MR patients, and MR degree is significantly improved at early follow-up. However, the benefit of LifeClip should be validated in a larger sample size of Chinese population and through long-term follow-up.
ObjectiveTo compare the early clinical efficacy and safety of transapical transcatheter aortic valve implantation (TA-TAVI) with surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis (AS). MethodsA retrospective study was conducted on patients with severe AS admitted to the Department of Cardiovascular Surgery, The First Affiliated Hospital of University of Science and Technology of China from January 2020 to March 2024. According to the surgical method, patients were divided into a SAVR group and a TA-TAVI group, and the clinical data of the two groups were compared. ResultsA total of 71 patients were included, with 45 in the SAVR group, including 33 males and 12 females, aged 16-75 (60.89±10.88) years; 26 in the TA-TAVI group, including 15 males and 11 females, aged 61-83 (72.85±5.53) years. The results showed that postoperative aortic valve transvalvular flow velocity (2.31±0.38 m/s vs. 2.60±0.50 m/s, P=0.019) and transvalvular pressure gradient (21.09±6.03 mm Hg vs. 28.20±10.79 mm Hg, P=0.001) in the TA-TAVI group were lower than those in the SAVR group. In terms of left ventricular end-diastolic diameter, both preoperative (56.73±7.74 mm vs. 52.36±7.00 mm, P=0.017) and postoperative (52.61±7.18 mm vs. 48.04±4.78 mm, P=0.010) values in the TA-TAVI group were larger than those in the SAVR group. In terms of left ventricular ejection fraction, the preoperative value in the TA-TAVI group was lower than that in the SAVR group (58.00%±13.84% vs. 64.87%±7.63%, P=0.026), but there was no statistical difference between the two groups after surgery (P=0.670). The operation time and drainage volume on the first day after surgery in the TA-TAVI group were shorter or lower than those in the SAVR group (P<0.05). There was no statistical difference between the two groups in the postoperative hospital stay, ICU stay, or postoperative mechanical ventilation time (P>0.05). In addition, no serious complications occurred in patients after SAVR, while perivalvular leakage (2 patients), third-degree atrioventricular block (1 patient), and death (3 patients) occurred in the TA-TAVI group. ConclusionFor elderly patients with severe AS and poor cardiac function, TA-TAVI technology has minimal surgical trauma, high safety and effectiveness, and is a safe and effective treatment option besides traditional surgical operations.
ObjectiveTo introduce the role of three dementional computed tomograph (3D-CT) for patients underwent transcatheter aortic valve implantation (TAVI) procedure in perioperative evaluation. MethodsFrom April 2014 to June 2015, we retrospectively analyzed clinical data of 28 patients with severe aortic stenosis underwent successful TAVI procedure using new second-generation device, who were enrolled in this study including 12 males and 16 females at mean age of 72.8±4.5 years. We used 3D-CT to get the perioperative relative evaluation, including valve morphology and calcification degree, annular diameter, aoronary ostium height, ascending aorta, aortic sinus diameter, left ventricular-aortic angle, optimal intraoperative angiogram projection angle. Based on the evaluation by 3D-CT image, the prosthesis size, balloon size, best intraoperative imaging projection angle and approach of apex were then chosen. ResultsAll patients with severe aortic stenosis underwent successful TAVI procedure with mean logistic Euro-SCORE I:26.2%±7.9%. CT image revealed that mean aortic annular diameter was 24.6±1.8 mm with mean valve prosthesis size 25.8±1.1 mm and pre-dilation balloon size 23.1±1.2 mm and 76.8% patients were of tricuspid aortic valve with severe calcification and 25% patients were of asymmetric calcification. Optimal intraoperative angiogram image was achieved in 92.9% patients with the help of preoperative CT image. There was a statistic difference in mean transvalvular gradient after valve implantation (54.1±15.3 mm Hg vs. 13.1±8.5 mm Hg, P<0.05). And there was no mortality or severe complication postoperatively. Conclusion3D-CT image palys an important role during perioperative evaluation of TAVI procedure and it can be helpful for Chinese doctors to operate TAVI successfully.
An 81-year-old male patient was admitted to Guangdong Provincial People's Hospital due to chest distress and shortness of breath after activity for half a year. Examination after admission revealed severe aortic insufficiency, tricuspid aortic valve and extremely horizontal aorta with an aortic root angulation of 99°. The Society of Thoracic Surgeons score was 7%. And taking the strong demand of the patient and his family into consideration, we decided to perform transapical transcatheter aortic valve replacement after multidisciplinary evaluation. The procedure was successfully performed by means of low deployment land zone and traction of pre-exist Prolene suture. Three-month follow-up confirmed the normal function of aortic prosthetic valve without residual regurgitation. This case provides a reference for the interventional treatment in patients with extremely horizontal aorta.
Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up period. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.
ObjectiveTo compare the in-hospital outcomes of transapical transcatheter aortic valve replacement (TA-TAVR) for bicuspid aortic valve (BAV) patients and tricuspid aortic valve (TAV) patients. MethodsPatients (including BAV and TAV patients) who underwent TA-TAVR with the J-ValveTM in West China Hospital from July 2014 to July 2020 were included consecutively. The clinical outcomes of the patients were analyzed. ResultsA total of 354 patients were included in the study, 75 in the BAV group and 279 in the TAV group. There were 229 males and 125 females with a mean age of 72.2±6.0 years. No death occurred during the procedure, and the overall technical success rate was 97.7%. The all-cause in-hospital mortality rate was 1.4%. Twenty (26.7%) patients with BAV and 46 (16.5%) patients with TAV had mild or higher perivalvular leaks immediately after the procedure. No patients with BAV required permanent pacemaker implantation postoperatively, while 13 (4.7%) TAV patients required permanent pacemaker implantation, with an overall pacemaker implantation rate of 3.7%. One (1.3%) BAV patient and 7 (2.5%) TAV patients developed acute kidney injury postoperatively. One (1.3%) BAV patient and 1 (0.4%) TAV patient developed perioperative myocardial infarction. The average postoperative hospital stay was 7.6±3.6 d for BAV patients and 8.6±6.1 d for TAV patients. There was no statistical difference in primary or secondary in-hospital outcomes between BAV and TAV patients (P>0.05). ConclusionCompared to TAV patients, BAV patients have similar in-hospital outcomes, with a low incidence of adverse clinical outcomes, which provides preliminary evidence for its implementation in Chinese patients with a high proportion of BAV.
ObjectiveTo investigate the reliability and safety of the technique of percutaneous left ventricular transapical access guided by cardiac three dimensional CT angiography (3D-CTA) combined with echocardiography applied in structural heart defects.MethodsThe clinical data of 9 patients (7 males and 2 females with a median age of 50 years ranging from 43 to 64 years) with paravalvular leaks closed by percutaneous left ventricular transapical access in West China Hospital, from April 2015 to August 2018, were retrospectively analyzed. We applied preoperative cardiac 3D-CTA to define the puncture site and trace, which was established by combining with real-time guidance of transesophageal echocardiography (TEE/3D-TEE), and an occluder was deployed at the apical access point for hemostasis with real-time guidance of transthoracic echocardiography (TTE).ResultsThe puncture needles were successfully introduced into the left ventricular cavity at one time in all patients without injury of lung tissue, coronary artery or papillary muscle. There was no occluder displacement or apex bleeding. One patient developed pleural effusion caused by intercostal artery injury.ConclusionThat cardiac 3D-CTA is used to define puncture sites and trace with advantages of simplicity and repeatability. A safe access and secure exit of left ventricle can be achieved by combining with real-time guidance of echocardiography. There are acceptable technology-related complications.