【摘要】 目的 探讨纳米羟基磷灰石/聚酰胺66(nano-hydroxyapatite polyamide66,n-HA/PA66)颈椎融合器在颈椎间盘突出症前路手术重建中的临床疗效。 方法 2008年12月-2010年6月,对14例颈椎间盘突出症患者行前路椎间盘切除、椎管减压,以n-HA/PA66椎间融合器支撑植骨、钢板螺钉内固定治疗。随访时间3~12个月,平均6.3个月;随访时以日本矫形外科学会(Japan Orthopaedic Assoctiation, JOA)评分改善率评价患者神经功能恢复情况,复查X线片评估椎间融合器植骨融合情况,包括椎间高度及椎间融合器下沉情况。 结果 14例患者均成功完成颈椎前路减压手术以及椎间融合器的安放固定。所有患者术前症状均得到不同程度的改善,术后3、6、12个月的JOA改善率分别为87.0%、94.0%、97.0%。影像学检查显示所有患者植骨融合,椎间高度及椎间融合器的位置维持良好,无下沉、移位。 结论 n-HA/PA66颈椎间融合器具有早期支撑稳定功能,可有效维持颈椎椎间高度;术后植骨融合率高且便于X线片观察,是颈椎间盘突出症患者前路手术植骨的理想支撑材料,但长期效果需进一步随访观察。【Abstract】 Objective To evaluate the clinical effect of artificial cervical vertebra fusion apparatus of n-HA/PA66 in anterior reconstruction of cervical intervertebral disc herniation. Methods From December 2008 to June 2010, 14 patients with cervical intervertebral disc herniation underwent anterior cervical discectomy,spinal canal decompression,spinal canal decompression and reconstruction by n-HA/PA66 composite artificial vertebral body combined with plate instrumentation. The patients were followed up for 3 to 12 months with an average of 6.3 months. Neurological function was evaluated by improvement rate of JOA score and situations of the supporting body was observed by X-ray in 3,6,and 12 months after the surgery.The intervertebral height,the 1ocations, and the fusion rate of the supporting body were assessed in order to evaluate the stability of the cervical spine and alignment improvements. Results All the patients had undergone the operation successfully.The preoperative symptoms improved to varying degrees.JOA improvement rate were 87.0%, 94.0%, and 97.0% 3,6,and 12 months after the operation,respectively.Imaging studies showed that in all cases graft fusion were achieved,and cervical alignments,intervertebral height,cervical spine stability and the locations of the artificial vertebral body were well maintained.No displacement and subsidence of the artificial vertebral body occurred. Conclusion n-HA/PA66 artificial vertebral body can provide early cervical spine support and stability and cervical intervertebral height.It has a high rate of graft fusion and is convenient to observe by X-ray.Therefore,n-HA/PA66 can be taken as an ideal graft for anterior degenerative cervical spine operation,but further follow-up study is still needed to evaluate the long-term effects.
Objective To investigate the effect of tissue engineering bone compounded in vitro by nanohydroxyapatite/collagen/ polylactic acid (nHAC/PLA) and recombinant human bone morphogenetic protein 2 (rhBMP-2) in repairing rabbit critical calvarial defects. Methods Forty eight New Zealand rabbits, weighting 2.0-2.5 kg, were made the models of critical cranial defects(15 mm in diameter) and divided into 4 groups randomly. Defects were repaired with autoflank bone in the positive control group; with no implant in the blank control group; with nHAC/PLA in the negative control; and with active nHAC/PLA(AnHAC/PLA) in the experimental group(the average quality of each AnHAC/PLA absorbed rhBMP-2 was 1.431 mg). The reapir results were observed through X-ray,HE dyeing and Masson’s trichrism dyeing after 8 and 16 weeks. Results The difference of bone formation was observed by X-ray block degree of skull defect area at 8 and 16 weeks. In the 8 th week and 16 th week, the radiopacities on cranial defect were 67.21%±2.06% and 86.48%±1.73% in the positive control group; 5.84%±1.92% and 9.48%±2.72% in the blank control group; 19.13%±2.51% and 35.67%±3.28% in the negative control group; and 58.84%±2.55% and 8561%±3.36% in the experimental group. There were significant differences between the negative control and the positive control group, and between the experimental group and the positive control group at 8 weeks(Plt;0.05) . There were significant differences between the negative control and blank group, and between the experiment and the blank group at 8 and 16 weeks(P<0.05). The histology observation showed that the width of bone trabecula at 16 weeks was more than that at 8 weeks and bone defectwas full of bone tissue in positive control group. The bone defect was full of fibrous tissue at 8 and 16 weeks, and there was no new bone in the blank group. The bone defect was full of remnant material and fibrous tissue in the negative control group. The implanted area was replaced by the new bone at 8 weeks and the new bone was lamellar at 16 weeks in the experimental group; the residual material was less in defect area and there were more osteoblasts surrounding. Conclusion The nHAC/PLA is a good scaffoldmaterial of rhBMP-2 and AnHAC/PLA has agood ability in repairing bone defect. So it is hopeful to be applied in the clnical repair of large bone defect.
ObjectiveTo compare the biomechanical differences between the kidney-shaped nano-hydroxyapatite/polyamide 66 (n-HA/PA66) Cage and the bullet-shaped n-HA/PA66 Cage. MethodsL2-L5 spinal specimens were selected from 10 adult male pigs. L2, L3 and L4, L5 served as a motor unit respectively, 20 motor units altogether. They were divided into 4 groups (n=5):no treatment was given as control group (group A); nucleus pulposus resection was performed (group B); bullet-shaped Cage (group C), and kidney-shaped Cage (group D) were used in transforaminal lumbar interbody fusion (TLIF) through left intervertebral foramen and supplemented by posterior pedicle screw fixation. The intervertebral height (IH) and the position of Cages were observed on the X-ray films. The range of motion (ROM) was measured. ResultsThere was no significant difference in the preoperative IH among 4 groups (F=0.166, P=0.917). No significant change was found in IH between at pre- and post-operation in group B (P>0.05); it increased after operation in groups C and D, but difference was not statistically significant (P>0.05). There was no significant difference in the postoperative IH among groups B, C, and D (P>0.05). The distance from Cage to the left margin was (3.06±0.51) mm in group C (close to the left) and (5.68±0.69) mm in group D (close to the middle), showing significant difference (t=6.787, P=0.000). The ROM in all directions were significantly lower in groups C and D than in groups A and B (P<0.05), and in group A than in group B (P<0.05). The right bending and compression ROM of group C were significantly higher than those of group D (P<0.05), but no statistically significant difference was found in the other direction ROM (P>0.05). ConclusionThe bullet-shaped and kidney-shaped Cages have similar results in restoring IH and maintaining the stability of the spine assisted by internal fixation. Kidney-shaped Cage is more stable than bullet-shaped Cage in the axial compression and the bending load opposite implant, it can be placed in the middle and back of the vertebral body more ideally.
Objective To assess the mid-term effectiveness of anterior decompression and fusion with nano-hydroxyapatite/polyamide 66 (n-HA/PA66) cage in treatment of cervical spondylotic myelopathy. Methods A retrospective study was made on 48 patients with cervical spondylotic myelopathy who underwent anterior decompression and fusion with n-HA/PA66 cage between August 2008 and January 2010. There were 33 males and 15 females with an average age of 54.5 years (range, 42-72 years). The disease duration was 3-12 months (mean, 6 months). The affected segments included 35 cases of single segment (C3, 4 in 7, C4, 5 in 18, and C5, 6 in 10) and 13 cases of double segments (C3-5 in 7 and C4-6 in 6). Of 48 patients, 28 was diagnosed as having intervertebral disc protrusion, 12 as having ossification of posterior longitudinal ligament, and 8 as having vertebral osteophyte; 35 patients underwent single segmental anterior corpectomy and fusion, and 13 patients underwent single segmental anterior discectomy and fusion. The pre- and post-operative radiographs (cervical anteroposterior and lateral X-ray films and three-dimensional CT scans) were taken to measure the segmental height and lordosis angle. Brantigan et al assessment standard and visual analogue scale (VAS) and Japanese Orthopaedic Association (JOA) scores were used to evaluate the graft fusion and the improvement of clinical symptoms, respectively. Results All patients were followed up for 46 months on average (range, 36-54 months). No cage breaking, displacement, or sliding was found. At last follow-up, 36 cases were rated as Brantigan grade E, 10 cases as grade D, and 2 cases as grade C; the fusion rate was 96%. Both segmental height and lordosis angle were corrected significantly at immediate and 6 months after operation and last follow-up than those before operation (P lt; 0.05), but no significant difference was found among different time points after operation (P gt; 0.05). At last follow-up, the cage subsidence was (1.3 ± 1.0) mm. The VAS and JOA scores at 6 months after operation and last follow-up were significantly improved when compared with preoperative scores (P lt; 0.05), and the scores at last follow-up were superior to ones at 6 months after operation (P lt; 0.05). Conclusion The mid-term effectiveness of anterior decompression and fusion with the n-HA/PA66 cage in patients with cervical spondylotic myelopathy is satisfactory because it can effectively restore and maintain segmental height and lordosis angle and promote osseous fusion.
Objective To study the clinical effects of the artificial vertebral body of the biomimetic nanohydroxyapatite/polyamide 66 (nHA/PA66) compositefor the structural reconstruction and the height restoring of the vertebral body in the thoracolumbar fractures by the anterior surgical procedures. Methods From December 2003 to January 2006, 42 patients with thoracolumbar fractures received the anterior surgical procedures to decompress and reconstruct the spinal vertebral structure with the artificial vertebral body of the nHA/PA66 composite. Among the patients, there were 28 males and 14 females, aged 1767 years, averaged 43.6 years. The thoracolumbar fractures developed at T12 in 5 patients, at L1 in 17, at L2 in 14, and at L3 in 6. The height of the anterior border of thevertebral body amounted to 29%-47% of the vertebral body height, averaged 40.6%.The Cobb angle on the sagittal plane was 2138° averaged 27.6°. According tothe Frankel grading scale, the injuries to the nerves were as the following: Grade A in 7 patients, Grade B in 19, Grade C in 8, Grade D in 6, and Grade E in 2. Results All the 42 patients were followed up for 625 months. Among the patients, 36 were reconstructed almost based on the normal anatomic structure, and 6 were well reconstructed. The mean height of the anterior border of the vertebralbody was 40.6% of the vertebral body height before operation but 91.7% after operation. And the reconstructed height of the vertebra was maintained. The mean Cobb angle on the sagittal plane was 27.6°before operation but 13.4° after operation. All the patients had a recovery of the neurological function that had a 1grade or 2grade improvement except 7 patients who were still in Grade A and 2 patients who were in Grade D. The implant was fused 35 months after operation. No infection, nail break, bar/plate break or loosening of the internal fixation occurred. Conclusion The artificial vertebral body of the biomimetic nHA/PA66 composite can effectively restore the height and the structure of the vertebra, can be fused with the vertebral body to reconstruct the spinal structural stability effectively, and can be extensively used in the clinical practice.
【Abstract】 Objective To investigate the anti-infection and bone repair effects of cationic l i posome-encapsulatedvancomycin combined with the nano-hydroxyapatite/chitosan/konjac glucomannan (n-HA/CS/KGM) composite scaffold invivo. Methods Fifty-one 6-month-old New Zealand white rabbits, weighing 1.5-3.0 kg, were selected to prepare chronicinfectious tibia bone defect model by using Staphylococcus aureus. After 4 weeks, 48 survival rabbits were randomly divided into 4 groups (n=12). After debridement, defect was treated with nothing in group A, with n-HA/CS/KGM composite scaffold in group B, with vancomycin and n-HA/CS/KGM composite scaffold in group C, and with cationic l i posome-encapsulated vancomycin and n-HA/CS/KGM composite scaffold in group D. After 8 weeks of treatment, general observation, X-ray, HE staining, the bacterial culture, and the measurement of the longest diameter of bone defect were done. Results At 4 weeks after modeling, 48 rabbits were diagnosed as having osteomyelitis, including periosteal new bone formation, destruction of bone, and soft tissue swell ing. The Norden score was 3.83 ± 0.52. At 8 weeks after treatment, sinus healed in groups C and D, but sinus was observed in groups A and B; the gross bone pathologieal scores of group D were significantly better than those of groups A and B (P lt; 0.05). Bone defects were repaired completely in group D, the results of the longest diameter of bone defects in group D was significantly better than those in the other 3 groups (P lt; 0.05). New bone formation was observed in groups C and D, but periosteal reactionand marrow low-density shadow were observed in groups A and B; Norden score in group D was significantly better than those in groups A, B, and C (P lt; 0.05). HE staining showed that there were a large number of trabecular bone formation and fibrosis, with no obvious signs of infection in groups C and D, but neutrophil accumulation was observed in groups A and B; Smeltzer scores in groups C and D were significantly better than those in groups A and B (P lt; 0.05). Bacteriological results showed higher negative rate in groups C and D than in groups A and B (P lt; 0.05). Conclusion Cationic l iposome-encapsulated vancomycin and n-HA/CS/KGM composite scaffold can be a good treatment for infectious bone defects in rabbits, providing a new strategy for the therapy of bone defects in chronic infection.
Objective To investigate the safety of nano-hydroxyapatite/polyamide 66 (n-HA/PA66) bioactive support in bone grafting and fusion for elderly patients with lumbar tuberculosis, and to analyze its effectiveness and advantages by comparing with autologous iliac bone grafting. Methods A retrospective analysis was performed on 48 elderly patients with lumbar tuberculosis who met the selection criteria between January 2017 and January 2020. The patients all underwent one-stage posterior pedicle screw internal fixation combined with anterior lesion removal and bone grafting and fusion, of which 23 cases applied n-HA/PA66 bioactive support+allogeneic bone graft (n-HA/PA66 group) and 25 cases applied autologous iliac bone graft (autologous iliac bone group). There was no significant difference between the two groups in gender, age, bone density, disease duration, lesion segment, and preoperative pain visual analogue scale (VAS) score, Japanese Orthopaedic Association (JOA) score, and Cobb angle (P>0.05). The operation time, intraoperative blood loss, and postoperative complications, as well as the VAS score, JOA score, American Spinal Injury Association (ASIA) spinal cord injury grading, Cobb angle, and bone fusion were recorded and compared between the two groups. Results The operations were completed successfully in both groups. n-HA/PA66 group had significantly less operation time and intraoperative blood loss than the autologous iliac bone group (P<0.05). All patients were followed up 12-24 months, with an average of 15.7 months. And the difference in follow-up time between the two groups was not significant (P>0.05). Postoperative complications occurred in 3 cases (13%) in the n-HA/PA66 group and 10 cases (40%) in the autologous iliac group, and the difference in the incidence of complications between the two groups was significant (χ2=4.408, P=0.036). The postoperative VAS scores and JOA scores significantly improved when compared with the preoperative scores in both groups (P<0.05), and the difference was significant (P<0.05) between 2 weeks after operation and the last follow-up. The difference in VAS score at 2 weeks after operation was significant between the two groups (P<0.05), and there was no significant difference (P>0.05) at the other time points. At last follow-up, according to the ASIA grading, the effective improvement rate was 86% (18/21) in the n-HA/PA66 group and 90% (18/20) in the autologous iliac group, with no significant difference (χ2=0.176, P=0.675). Imaging review showed that grade Ⅰ bony fusion was obtained in both groups, and the fusion time of bone graft in the n-HA/PA66 group was significantly longer than that in the autologous iliac bone group (P<0.05). There was no significant difference in the Cobb angle at each time point between the two groups (P>0.05). No recurrence of tuberculosis, loosening or fracture of the internal fixator, or displacement of the bone graft was observed during follow-up. Conclusion In elderly patients with lumbar spine tuberculosis, the n-HA/PA66 bioactive support combined with allogeneic bone graft can effectively restore and maintain the fusion segment height and physiological curvature of the lumbar spine, and the fusion rate of bone graft is similar to that of autologous iliac bone, which can achieve better effectiveness.
Objective To evaluate the short-term effectiveness of nano-hydroxyapatite/polyamide-66 (n-HA/PA66) intervertebral cage for lumbar interbody fusion in the patients with lower lumbar degenerative diseases. Methods Between January and October 2011, 20 patients with lower lumbar degenerative diseases underwent transforaminal lumbar interbody fusion with n-HA/PA66 intervertebral cage. There were 8 males and 12 females, aged 22-80 years (mean, 51 years). The disease duration was 1 to 24 months (mean, 4 months). L4, 5 fusion was performed in 8 cases, L5, S1 fusion in 9 cases, and L4-S1 fusion in 3 cases. Among 20 cases, 3 were diagnosed as having recurrent lumbar disc protrusion, 5 as having lumbar degenerative spondylolisthesis, 9 as having lumbar isthmic spondylolisthesis, and 3 as having lumbar spinal stenosis. The intervertebral height and lordosis were measured on X-ray film to assess the surgical correction and postoperative sustain while osseous fusion was observed on 3-dimensional CT. The Oswestry disability index (ODI) and short-form 36 health survey scale (SF-36) scores were obtained to assess the status of clinical recovery. Results All patients had incision healing by first intention. The pain and numb were relieved in varying degrees after operation. No cerebrospinal leakage, nerve root injury, or wound infection was occurred. All patients were followed up 6-9 months (mean, 7 months). No cage displacement or collapse was found. The intervertebral height and lordosis of single fusion segment were significantly improved at 3 days and 3, 6 months after operation when compared with those at preoperation (P lt; 0.01); there was no significant difference among each time point after operation (P gt; 0.05). The fusion rate was 74% at 3 months after operation and 96% at 6 months after operation, with an average of 4 months (range, 3-9 months) for interbody fusion. The ODI and SF-36 scores were significantly improved at 3 days and 6 months after operation when compared with the scores at preoperation (P lt; 0.01); there was no significant difference among each time point after operation (P gt; 0.05). Conclusion The interbody fusion with n-HA/PA intervertebral cage is effective and safe to treat the lower lumbar degenerative diseases. The n-HA/PA66 intervertebral cage is an ideal device of interbody fusion with high fusion rate, low subsidence rate, and high transmission X-ray, but the long-term effectiveness need further observation.
Objective To develop the plastic nano-hydroxyapatite (nano-HA)/poly (3-hydroxybutyrate-hydroxyvalerate) polyethylene glycol(PHBV-PEG) gentamicin (GM) drug delivery system(DDS)(nano-HA/PHBV-PEG-GM-DDS) for treating osteomyelitis and find its releasing character in vivo. Methods The plastic nano-HA/PHBV- PEG-GM-DDS was prepared using nanoHAas the core carrier of GM, nano-HA with PHBV and PEG as coating and plastic fibrin glue(FG) as microsphere scaffold. The morphological features of nano-HA,drug loaded nano-HA and drug loaded nano-HA/PHBVPEG microsphere were examined by electron microscope.The GM concentration in blood, cortex bone and cancellousbone was detected at 12 different time points by the method of K-B after the plastic nano-HA/PHBV-PEGGM-DDS was implanted into the femora of 36 rabbits. Its GM releasing character was assayed in vivo. Results Nano-HA was similar to a blackjack, and its length was less than 60 nm. Drug loaded nano-HA appeared natural crystal condensate, of which surface adsorbed massive GM. The average grain diameter was 200.5 nm. Drug loaded nanoHA/PHBV-PEG microsphere had a shrinkable porous structure, of which surface configuration was consistent. The average grain diameter was 34.5 μm. The GM concentration and the antibacterial annulus was in the linear correlation. The correlation coefficient was 0.998. In cortex and cancellous bone tissue, the GM concentration was about 95.50±16.50 μg/ml and 80.20±13.80 μg/ml from the plastic nano-HA/PHBV-PEG-GM-DDS on the 1st day, then decreased gradually. After 56 days of operation, the GM concentration still exceeded the minimum inhibitory concentrationfor the staphylococcus aureus, but the peak level of serum GM concentration wasunder the nephrotoxicity concentration. Conclusion Plastic nano-HA/PHBV-PEG-GM-DDS was a good drug delivery system with sustained antibiotic effect in vivo. It was an effective method for the treatment of osteomyelitis.
Objective To fabricate a nanohydroxyapatite-chitosan(nano-HA-CS) scaffold with high porosity by a simple and effective technique and to evaluate the physical and chemical properties and the cytocompatibility of the composite scaffold. Methods The threedimensional nano-HA-CS scaffolds with high porosity were prepared by the in situ hybridization-freeze-drying method. The microscopic morphology and components of the composite scaffolds were analyzed by the scanning electron microscopy (SEM), the transmission electron microscopy(TEM), the X-ray diffraction(XRD)examination, and the Fourier transformed infrared spectroscopy(FTIR). The calvarial osteoblasts were isolated from the neonatal Wistar rats. The serial subcultured cells (3rd passage) were respectively seeded onto the nanoHACS scaffold and the CS scaffold, and then were cocultured for 2, 4, 6 and 8 hours. At each time point,four specimens from each matrix were taken to determine the celladhesion rate. The cell morphology was observed by the histological staining and SEM. Results The macroporous nanoHACS scaffolds had a feature of high porosity with a pore diameter from 100 to 500 μm (mostly 400500 μm). The scaffolds had a high interval porosity; however, the interval porosity was obviously decreased and the scaffold density was increased with an increase in the contents of CS and HA. The SEM and TEM results showed that the nanosized HA was synthesized and was distributed on the pore walls homogeneously and continuously. The XRD and FTIR results showed that the HA crystals were carbonatesubstituded and not wellcrystallized. The cytocompatibility test showed that the seeded osteoblasts could adhere the scaffolds, proliferating and producing the extracellular matrix on the scaffolds. The adherence rate for the nanoHACS scaffolds was obviously higher than that for the pure CS scaffolds. Conclusion The nano-HA-CS scaffolds fabricated by the in situ hybridization-freeze-drying method have a good physical and chemical properties and a good cytocompatibility; therefore, this kind of scaffolds may be successfully used in the bone tissue engineering.