west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "糖化血红蛋白" 17 results
  • Diagnostic value of shear wave elastography combined with vascular endothelial growth factor B and hemoglobin A1c in early diabetic peripheral neuropathy

    Objective To analyze the diagnostic value of shear wave elastography (SWE) combined with vascular endothelial growth factor B (VEGF-B) and hemoglobin A1c (HbA1c) in early diabetic peripheral neuropathy (DPN). Methods A total of 100 patients with type 2 diabetes mellitus (T2DM) admitted to Mianyang Central Hospital between October 2020 and October 2023 were selected and divided into a T2DM with DPN group (n=31) and a T2DM without DPN group (n=69) based on the presence or absence of DPN. Additionally, 50 healthy individuals from the same hospital’s health examination center were included as a healthy control group. The basic clinical characteristics, mean elasticity (Emean) values of the left and right median and tibial nerves, serum VEGF-B, and HbA1c levels were compared among the three groups. The diagnostic efficacy of SWE, VEGF-B, and HbA1c for DPN was evaluated using receiver operating characteristic (ROC) curves, and Pearson correlation analysis was performed to assess the relationships between median/tibial nerve Emean and VEGF-B/HbA1c. Results The Emean values of the left and right median nerves, Emean values of the left and right tibial nerves, serum VEGF-B, and HbA1c levels in the T2DM with DPN group were significantly higher than those in the T2DM without DPN group and the healthy control group (P<0.05). The Emean values of the left and right median and tibial nerves, Emean values of the left and right tibial nerves, and HbA1c level in the T2DM without DPN group were significantly higher than those in the healthy control group (P<0.05), while no significant difference was observed in serum VEGF-B level between the T2DM without DPN group and the healthy control group (P>0.05). The area under the ROC curve for the combined diagnosis of DPN using SWE, VEGF-B, and HbA1c was 0.859 [95% confidence interval (0.828, 0.955)]. The sensitivity of the combined diagnosis (93.72%) was significantly higher than that of individual diagnoses (78.82%, 75.39%, and 71.05%, respectively; P<0.05), while the specificity (88.64%) showed no significant difference compared to individual diagnoses (80.18%, 78.96%, and 82.88%, respectively; P>0.05). Positive correlations were observed between median/tibial nerve Emean and VEGF-B/HbA1c levels (r=0.428, 0.395, 0.416, and 0.416, respectively; P<0.05). Conclusions Elevated median/tibial nerve Emean, serum VEGF-B, and HbA1c levels are closely associated with DPN. The combination of SWE, VEGF-B, and HbA1c improves diagnostic sensitivity for DPN, demonstrating significant clinical value.

    Release date:2025-05-26 04:29 Export PDF Favorites Scan
  • Influence of resistance training intensity on glycosylated hemoglobin in elderly patients with type 2 diabetes: a meta-analysis

    Objectives To systematically analyze the effect of high-intensity and low-intensity resistance training on glycosylated hemoglobin (HbA1c) in elderly patients with type 2 diabetes. Methods PubMed, EBSCO, Cochrane Library, Web of science, Wanfang, Chinese National Knowledge Infrastructure and Chongqing VIP were searched to collect randomized controlled trials of resistance training intervention in elderly patients with type 2 diabetes. The search time limit was from the establishment of the database to August 28, 2021, and the RevMan 5.3 and Stata 15.0 software were used for meta-analysis. Results A total of 415 patients in 8 articles were included in this study. A subgroup analysis based on control measures showed that compared with the resistance training group, the HbA1c level effect value of the non- training group was weighted mean difference (WMD) = −0.54% [95% confidence interval (CI) (−1.06%, −0.03%), P=0.04)], the HbA1c level effect value of the flexibility training group was WMD=−0.47% [95%CI (−1.05%, 0.12%), P=0.12], the HbA1c level effect value of the aerobic training group was WMD=−0.10% [95%CI (−0.71%, 0.51%), P=0.75]. Subgroup analysis of resistance strength showed that compared with the flexibility or non-resistance training group, both high-intensity [WMD=−0.99%, 95%CI (−1.16%, −0.81%), P<0.00001] and low- and medium-intensity resistance training [WMD=−0.29%, 95%CI (−0.58%, −0.01%), P=0.05] can reduce HbA1c. Compared with the high-intensity resistance training, the HbA1c level effect value of the low- and medium-intensity resistance training was WMD=0.03% [95%CI (−0.33%, 0.39%), P=0.88]. Compared with the low- and medium-intensity resistance training, the HbA1c level effect value of the low- and medium-intensity aerobic training was WMD=−0.10% [95%CI (−0.71%, 0.51%), P=0.75]. Among all the included studies, only the high-intensity resistance training group reported multiple adverse events.ConclusionsCurrent evidence suggests that elderly patients with type 2 diabetes are more suitable to choose low-to-medium-intensity resistance training to control HbA1c. It is recommended that elderly patients with type 2 diabetes take 60% to 75% of the maximum muscle strength of medium-intensity resistance training.

    Release date:2022-02-24 02:27 Export PDF Favorites Scan
  • Anti-interference hemoglobin analysis system by high performance liquid chromatography

    High performance liquid chromatography (HPLC) is currently the mainstream technology for detecting hemoglobin. Glycated hemoglobin (HbA1c) is a gold indicator for diagnosing diabetes, however, the accuracy of HbA1c test is affected by thalassemia factor hemoglobin F (HbF)/hemoglobin A2 (HbA2) and variant hemoglobin during HPLC analysis. In this study, a new anti-interference hemoglobin analysis system of HPLC is proposed. In this system, the high-pressure three-gradient elution method was improved, and the particle size and sieve plate aperture in the high-pressure chromatography column and the structure of the double-plunger reciprocating series high-pressure pump were optimized. The system could diagnose both HbA1c and thalassemia factor HbF/HbA2 and variant hemoglobin, and the performance of the system was anti-interference and stable. It is expected to achieve industrialization. In this study, the HbA1c and thalassemia factor HbF/HbA2 detection performance was compared between this system and the world’s first-line brand products such as Tosoh G8, Bio-Rad Ⅶ and D10 glycosylated hemoglobin analysis system. The results showed that the linear correlation between this system and the world-class system was good. The system is the first domestic hemoglobin analysis system by HPLC for screening of HbA1c and thalassemia factor HbF/HbA2 rapidly and accurately.

    Release date:2021-12-24 04:01 Export PDF Favorites Scan
  • 健康人群糖化血红蛋白参考范围的建立

    目的建立实验室糖化血红蛋白(HbA1c)水平的参考范围,并验证其临床效果。 方法选取2013年4-5月行常规体检的健康成年人共218人。另选取20例首次诊断为糖尿病患者。采用日本TOSOH公司HLC-723G7全自动糖化血红蛋白分析仪测量HbA1c水平,验证参考范围的临床效果。 结果HbA1c的分布呈正态分布,其均数为5.44%,标准差为0.34%,>35岁组HbA1c明显高于≤35岁组,差异有统计学意义(t=-3.952,P<0.05)。两组参考范围分别是4.82%~6.24%和4.81%~5.90%。 结论年龄是是影响HbA1c的重要生理因素,应根据不同年龄建立HbA1c的参考范围。

    Release date: Export PDF Favorites Scan
  • Correlation between HbA1c on admission and blood glucose fluctuations and adverse events after coronary artery bypass grafting in non-diabetic patients

    ObjectiveTo explore the relationship between glycated hemoglobin (HbA1c) level and blood glucose fluctuations after coronary artery bypass grafting (CABG) and adverse events in non-diabetic patients, thus providing theoretical support for intensive preoperative blood glucose management in patients undergoing CABG surgery.MethodsA total of 304 patients undergoing CABG with or without valvular surgery from October 2013 to December 2017 were enrolled in this prospective, single-center, observational cohort study. We classified them into two different groups which were a low-level group and a high-level group according to the HbA1c level. There were 102 males and 37 females, aged 36–85 (61.5±9.5) years in the low-level group, and 118 males and 47 females aged 34–85 (63.1±9.4) years in the high-level group. The main results were different in hospital mortality and perioperative complications including in-hospital death, myocardial infarction, sternal incision infection, new stroke, new-onset renal failure and multiple organ failure. To assess the effects of confounding factors, multivariate logistic regression analysis was used.Results Postoperative blood glucose fluctuation was more pronounced in the high-level group than that in the low-level group before admission [0.8 (0.6, 1.2) mmol/L vs. 1.0 (0.8, 1.8) mmol/L, P<0.01]. This study also suggested that the incidence of major adverse events was significantly lower in the low-level group compared with the high-level group (P=0.001). Multivariate logistic regression analyses to correct the influence of other confounding factors showed that HbA1c (OR=2.773, P=0.002) and postoperative blood glucose fluctuations (OR=3.091, P<0.001) could still predict the occurrence of postoperative adverse events.ConclusionHbA1c on admission can effectively predict blood glucose fluctuations in 24 hours after surgery. Secondly, HbA1c on admission and postoperative blood glucose fluctuations can further predict postoperative adverse events. It is suggested that we control the patient's preoperative HbA1c at a low level, which is beneficial to control postoperative blood glucose fluctuation and postoperative adverse events.

    Release date:2019-09-18 03:45 Export PDF Favorites Scan
  • Study on the association between glycosylated hemoglobin level and poor prognosis of intravenous thrombolysis in patients with acute ischemic stroke

    ObjectiveTo explore the association between glycosylated hemoglobin level and poor prognosis in acute ischemic stroke (AIS) patients treated with intravenous thrombolysis.MethodsThe AIS patients treated with recombinant tissue-type plasminogen activator who were hospitalized in the Department of Neurology of the First Affiliated Hospital of Henan University of Science and Technology from September to December 2020 were retrospectively included. According to different levels of glycosylated hemoglobin, they were divided into pre-diabetic group (5.7%≤glycated hemoglobin≤6.4%), diabetic group (previously diabetic or glycosylated hemoglobin≥6.5%), and non-diabetic group (glycated hemoglobin <5.7%). The relevant information of the patients was collected, and a telephone follow-up was conducted 90 days after discharge. According to the modified Rankin Scale (mRS) score, the patients were divided into the good prognosis group (mRS score≤2) and the poor prognosis group (mRS score>2). Logistic regression analysis was used to determine the risk factors for the poor prognosis of intravenous thrombolysis in patients with AIS.ResultEventually 101 patients were included, including 44 in the non-diabetic group, 24 in the pre-diabetic group, and 33 in the diabetic group. And 64 patients were in the good prognosis group and 37 patients were in the poor prognosis group. Regression analysis results showed that diabetes was associated with poor prognosis 3 months after intravenous thrombolysis in patients with AIS [odds ratio=6.518, 95% confidence interval (1.568, 27.096), P=0.010]; and the higher the National Institutesof Health Stroke Scale score at admission was, the higher the risk of poor prognosis would be [odds ratio=1.421, 95% confidence interval (1.231, 1.640), P<0.001].ConclusionIn AIS patients who received intravenous thrombolysis, diabetes is associated with poor prognosis after 3 months.

    Release date:2021-07-22 06:28 Export PDF Favorites Scan
  • Correlation between Glycosylated Hemoglobin A1c and Severity of Coronary Artery Lesions in Young Men with Acute Myocardial Infarction

    Objective To investigate the correlation between glycosylated hemoglobin A1c (HbA1c) and severity of coronary artery lesions in young men with acute myocardial infarction (AMI). Methods Total 278 young men with AMI less than 45 years old were retrospectively studied, and all of them were admitted to hospital from January 2009 to December 2011, and had undergone coronary angiography. According to the results of coronary angiography, the patients were divided into three groups based on the number of artery lesions: the single group (156 cases), the double group (64 cases) and the triple group (58 cases). The relationship between the severity of coronary artery lesions and the following factors were observed: HbA1c, systolic blood pressure (SBP), diastolic blood pressure (DBP), hemoglobin (Hb), serum uric acid (UA), total cholesterol (TC), triglyceride (TG), high density lipoprotein cholesterol (HDL-C), low density lipoprotein cholesterol (LDL-C), body mass index (BMI), smoking history, drinking history and family history of early coronary artery disease. Results a) HbA1c levels were gradually raised in all the three groups, but the single group (6.39±1.67%) was significantly lower than the double group (6.91±1.63%) and the triple group (7.41±2.12%), with significant differences (Plt;0.05); the HbA1c level of the single group was significantly lower than the triple group in both the ST-segment elevation AMI (6.42±1.68% vs. 7.17±1.86%, Plt;0.05) and the non-ST-segment AMI (5.57±0.37% vs. 8.56±2.83%, Plt;0.05); the HbA1c level of the single group was significantly lower than the triple group in patients with diabetes millitus (8.31±1.83% vs. 8.59±2.02%, Plt;0.05) and in patients without diabetes millitus (5.56±0.33% vs. 5.74±0.37%, Plt;0.05); b) There were significant differences in SBP, TC, HDL-C, LDL-C and drinking history between the single group and the other two groups (all Plt;0.05), and there were significant differences in DBP and TG between the single group and the double group (all Plt;0.05); and c) The results of logistic regression analysis showed that, LDL-C (OR=1.790), HbA1c (OR=1.287) and SBP (OR=1.042) were the independent risk factors (all Plt;0.05) for multiple lesions in coronary arteries of young men with AMI. Conclusion Glycosylated hemoglobin A1c is an independent risk factor for multiple lesions in coronary arteries of young men with AMI.

    Release date:2016-08-25 02:39 Export PDF Favorites Scan
  • Study on the correlation between the time within the glucose target range, the level of glycosylated hemoglobin and the risk of diabetic retinopathy

    ObjectiveTo observe and analyze the correlation between time within target glucose range (TIR) and hemoglobin A1c (HbA1c) and the risk of diabetic retinopathy (DR). MethodsA retrospective clinical study. From March 2020 to August 2021, 91 patients with type 2 diabetes mellitus (T2DM) who were hospitalized in Department of Endocrinology and Metabolic Diseases, Affiliated Hospital of Weifang Medical University, were included in the study. All patients underwent Oburg's no-dilatation ultra-wide-angle laser scan ophthalmoscopy, HbA1c and continuous glucose monitoring (CGM) examinations. According to the examination results and combined with the clinical diagnostic criteria of DR, the patients were divided into non-DR (NDR) group and DR group, with 50 and 41 cases respectively. The retrospective CGM system was used to monitor the subcutaneous interstitial fluid glucose for 7 to 14 consecutive days, and the TIR was calculated. Binary logistic regression was used to analyze the correlation between TIR, HbAlc and DR in patients with T2DM0. At the same time, a new indicator was generated, the predicted probability value (PRE_1), which was generated to represent the combined indicator of TIR and HbA1c in predicting the occurrence of DR. The receiver operating characteristic curve (ROC curve) was used to analyze the value of TIR, HbAlc and PRE_1 in predicting the occurrence of DR. ResultsThe TIR of patients in the NDR group and DR group were (81.58±15.51)% and (67.27±22.09)%, respectively, and HbA1c were (8.03±2.16)% and (9.01±2.01)%, respectively. The differences in TIR and HbA1c between the two groups of patients were statistically significant (t=3.501,-2.208; P=0.001, 0.030). The results of binary logistic regression analysis showed that TIR, HbA1c and DR were significantly correlated (odds ratio=0.960, 1.254; P=0.002, 0.036). ROC curve analysis results showed that the area under the ROC curve (AUC) of TIR, HbA1c and PRE_1 predicting the risk of DR were 0.704, 0.668, and 0.707, respectively [95% confidence interval (CI) 0.597-0.812, P=0.001; 95%CI 0.558-0.778, P=0.006; 95%CI 0.602-0.798, P=0.001]. There was no statistically significant difference between TIR, HbA1c and PRE_1 predicting the AUC of DR risk (P>0.05). The linear equation between HbAlc and TIR was HbAlc (%) = 11.37-0.04×TIR (%). ConclusionsTIR and HbA1c are both related to DR and can predict the risk of DR. The combined use of the two does not improve the predictive value of DR. There is a linear correlation between TIR and HbAlc.

    Release date:2022-02-17 02:00 Export PDF Favorites Scan
  • 糖化血红蛋白检测结果的置信区间

    目的 应用生物学变异和分析变异探讨糖化血红蛋白(glycosylated hemoglobin,HbA1c)测定结果对糖尿病诊断治疗的影响。 方法 以三级质量规范为标准,应用 HbA1c 生物学变异和参考变化值,分析实验室测量固有分析变异(analytical variance,CVA)、个体内生物学变异(within-individual variation,CVI)以及偏倚对 HbA1c 测定结果的影响。 结果 HbA1c 的测定结果随 CVA 的增加而导致的额外偏倚不呈线性增加。不同的生物学变异质量规范要求对 HbA1c 测定结果的影响有差异。不同的 CVA 对非糖尿病个体和糖尿病患者的 HbA1c 测定结果离散范围影响不同。HbA1c 检测要求分析方法的 CVA<3%。 结论 糖尿病诊断和治疗并不能单独依赖 HbA1c 测定结果的实际数值为判断标准。应结合 CVA 及 CVI 对于 HbA1c 测定值偏倚的影响给出测定值,并附上置信区间。

    Release date:2017-07-21 03:43 Export PDF Favorites Scan
  • 高原人群糖化血红蛋白的研究进展

    在多项血糖监测的指标中,糖化血红蛋白(hemoglobin A1c,HbA1c)目前是在评价血糖管理、治疗方案有效性及防控糖尿病并发症中运用最广泛且最重要的指标。然而高原低氧、低气压及民族等因素对 HbA1c 水平影响的结论仍存在争议,该文就高原环境及民族差异对 HbA1c 的具体影响及可能的机制进行了综述。

    Release date:2017-12-25 06:02 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content