west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "粉碎性骨折" 19 results
  • TREATMENT OF COMMINUTED FRACTURES AT DISTAL FEMUR AND PROXIMAL TIBIA WITH LESS INVASIVE STABILIZATION SYSTEMS

    Objective To study the clinical outcome of comminuted factures at distal femur and proximal tibia treated with AO less invasive stabilization systems (LISS). Methods The clinical data of 14 cases of distal femoral fracture and proximal tibial fracture from September 2003 to May 2005 were analyzed retrospectively. The injury was caused by traffic accident in 9 cases, by fall in 3 cases and by slipping in 2 cases. Of 14 cases, there were 5 open fractures and 9 close fractures, including 5 cases of distal femoral comminuted fracture and 9 cases of proximal shaft comminuted fractures. According to AO/OTA classification, the fractures were classified as 33C2 in 3 cases,33C3 in 2 cases,41A2 in 2 cases,41A3 in 2 cases,41B2 in 3 cases and 41C2 in 2 cases. All patients were treated by the internal fixation with LISS-distal femur or with LISS-proximal tibia. Healing of wounds, the X-ray films before and after operations, and therecovery of joint function were observed. Results The patients were followed up from 1 month to 20 months (11 months on average). Twelve cases achieved solid osseous unions from 3 months to 5 months postoperativly; 2 cases had a good reduction and recovered smoothly 2-3 months postoperatively. The results were excellent in 10 cases, good in 3 cases and fair in 1 case according to Johner-Wruhs knee scoring. The range of knee flexion-extension was 110-130° in 11 cases, 100° in 2 cases and 80° in 1 case. Conclusion LISS is an effective method of internal fixation for treating comminntedfracture of distal femur or proximal tibia. It has the advantages of less injury, satisfied reduction and reliable fixation.

    Release date:2016-09-01 09:26 Export PDF Favorites Scan
  • 锁骨粉碎性骨折合并锁骨下静脉损伤二例

    详见正文

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
  • MANAGEMENT OF INFERIOR POLAR COMMINUTED FRACTURES OF PATELLA AND PATELLAR TENDON INJURY

    Objective To investigate the treatment and effectiveness of inferior polar comminuted fractures of patella and patellar tendon injury. Methods Between January 2003 and December 2008, 5 patients with inferior polar comminuted fractures of patella and patellar tendon injury were treated with Nitinol Patellar Concentrator and fascia lata allograft. There were 3 males and 2 females with a mean age of 33.7 years (range, 20-48 years). The interval of injury and operation was 1-5 days. Fracture degree: 3 cases had 3 fractures of patella, 2 cases had 4 fractures; patellar tendon injury degree: 3cases had horizontal rupture of middle l igament, 1 case had obl ique rupture of tibial tubercle, and 1 case had longitudinal partial rupture. Results Heal ing of incision by first intention was achieved in all patients, and no compl ication of infection or deep venous thrombosis occurred. The X-ray films at 2 days after surgery showed that patella recovered to normal height, which meaned ratio of patella height to patellar tendon length recovered to 1 : 1. Five cases were followed up 18 months on average (range, 10-22 months). At 3-12 weeks after surgery, the knee function of the injury side almost reached that of the normal side in 4 patients, and the knee range of motion was about 100° in 1 patient. The fracture heal ing time was 3-5 months. At 12-15 months after surgery, patella holder was taken out and no lost of reduction or refracture occurred. During follow-up, there was no fracture displacement, loosening and breakage of implant, or rerupture of patellar tendon. According to ZHANG Chuncai’ s criterion for knee joint function, the results were excellent in 3 cases, good in 1 cases, and fair in 1 case with an excellent and good rate of 80%. According to XU Shaoting’s criterion for knee joint function, the results were excellent in 2 cases, good in 2 cases, and fair in 1 case with an excellent and good rate of 80%. Conclusion Nitinol Patellar Concentrator and fascia lata allograft is a new method to treat inferior polar comminuted fractures of patella and patellar tendon injury, and it can ensure the knee joint stabil ity in early motion after surgery.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • 自锁髓内钉在肱骨粉碎性骨折的应用

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • ANATOMICAL PLATE COMBINED WITH CORTICAL BONE PLATE ALLOGRAFTS FOR TREATMENT OF COMMINUTED FRACTURES OF FEMORAL CONDYLES

    ObjectiveTo summarize the effectiveness of anatomical plate combined with cortical bone plate allografts in the treatment of comminuted fractures of the femoral condyles. MethodsBetween January 2008 and December 2012, 18 patients with comminuted fractures of the femoral condyles were treated, including 13 males and 5 females with an average age of 45 years (range, 23-65 years). Fractures were caused by traffic accident in 11 cases, by falling from height in 4 cases, and by the other in 3 cases. The locations were the left side in 7 cases and the right side in 11 cases. Of 18 fractures, 12 were open fractures and 6 were closed fractures. The mean time from injury to operation was 6 days (range, 4-15 days). The fixation was performed by anatomical plate combined with cortical bone plate allografts, and autograft bone or allogeneic bone grafting were used. ResultsSuperficial local skin necrosis occurred in 1 case, and was cured after skin graft, and other incisions achieved primary healing. All patients were followed up 12-36 months (mean, 23 months). X-ray films showed that bone union was achieved within 3-12 months (5.6 months on average). No related complication occurred, such as fixation loosening, refracture, infection, or immunological rejection. According to Merchan et al. criteria for knee joint function evaluation, the results were excellent in 7 cases, good in 9 cases, fair in 1 case, and poor in 1 case at last follow-up; the excellent and good rate was 88.9%. ConclusionAnatomical plate combined with cortical bone plate allograft fixation is a good method to treat comminuted fractures of the femoral condyles. This method can effectively achieve complete cortical bone on the inside of the femur as well as provide rigid fixation.

    Release date: Export PDF Favorites Scan
  • TREATMENT OF FIRST METATARSAL DIAPHYSIS COMMINUTED FRACTURES WITH MINI-PLATE VIA MEDIAL APPROACH

    ObjectiveTo explore the effectiveness and operative methods to treat first metatarsal diaphysis comminuted fractures with mini-plate via medial approach. MethodsBetween January 2012 and January 2013, 15 patients with first metatarsal shaft comminuted fractures were treated. There were 11 males and 4 females (6 left feet and 9 right feet) with an average age of 38.6 years (range, 27-56 years). The injury causes included falling injury in 6 cases, crash injury of heavy object in 7 cases, and sprain in 2 cases. The left side was involved in 6 cases and the right side in 9 cases. The time from injury to operation was 8.5 days on average (range, 7-10 days). According to AO classification, all cases were rated as 81(T)-C2 type. The surgical treatments included open reduction and internal fixation with mini-plate by medial approach. ResultsPrimary healing of incision was obtained in all cases, and no infection occurred. Twelve patients were followed up 18 months on average (range, 12-24 months). All fractures healed well, and the mean time of bone union was 11.5 weeks (range, 10-14 weeks). No loosening or breakage of internal fixation was observed. At last follow-up, the patients could walk with full weight-bearing, and had no pain. According to American Orthopaedic Foot and Ankle Society (AOFAS) hallux metatarsophalangeal-interphalangeal scale, the mean score was 85.2 (range, 76-96). ConclusionAnatomic reduction and stable internal fixation are important for first metatarsal comminuted fracture, which is the key point for recovery of foot form and foot arch function. And the medial approach could achieve full exposure and improve the cosmetic results.

    Release date:2016-08-25 10:18 Export PDF Favorites Scan
  • EFFECTIVENESS OF DIGITAL CUSTOMIZED STEEL PLATE IN TREATMENT OF COMPLEX FRACTURES OF LIMBS

    ObjectiveTo observe the effectiveness of digital customized plate in the treatment of complex limb fracture. MethodsBetween January 2012 and May 2013, CT raw data of complex limb fracture were used to establish the fracture three-dimensional simulation model after reduction, and a customized personalized anatomic plate was designed and used for internal fixation after open reduction in 42 cases. There were 22 males and 20 females, aged 16-53 years (average, 37.4 years). The causes of injury were traffic accident in 21 cases, falling from height in 18 cases, crush by heavy objects in 3 cases, including 26 cases of fresh closed fracture and 16 cases of open fracture (9 cases of type Ⅰ and 7 cases of type Ⅱ according to Gustilo classification). According to AO classification, there were 15 cases of humerus comminuted fracture, 4 cases of radial comminuted fracture, 8 cases of femoral comminuted fracture, and 15 cases of tibia comminuted fracture. The interval of injury and operation was 6-28 days (mean, 10 days). ResultsReduction and internal fixation of fracture were successfully performed on 42 patients. The length and position of digital customized plate, direction and length of screw implant, number of screw were basically identical with preoperative design. The operation time was 35-120 minutes (mean, 70 minutes); the blood loss volume was 30-500 mL (mean, 180 mL); and X ray fluoroscopy frequency was 2-6 times (mean, 3 times). Superficial infection occurred in 2 cases, and was cured after dressing change; primary healing of incision was obtained in the other patients. Forty-two cases were followed up 6-24 months with an average of 11.5 months. The fracture healing time was 8-19 weeks (mean, 14 weeks) in 41 cases; delayed union occurred in 1 case at 44 weeks after operation. The fracture anatomical reduction was achieved in 19 cases, malunion in 3 cases, and functional reduction in the other patients. At last follow-up, no plate and screw loosening and breakage was observed. ConclusionDigital customized plate in treatment of complex fractures of limbs, especially for the multiple comminuted fracture of long bones of the limbs has the advantages of convenient operation, less trauma, fewer complications, and good effectiveness.

    Release date: Export PDF Favorites Scan
  • DUAL PLATING FIXATION FOR DISTAL FIBULAR COMMINUTED FRACTURES

    ObjectiveTo evaluate the technique and effectiveness of dual plating fixation for distal fibular comminuted fractures. MethodsBetween November 2010 and November 2011, 16 patients with distal fibular comminuted fractures were treated, including 10 males and 6 females with an average age of 49.8 years (range, 35-65 years). All the patients had closed injury, which was caused by sprain in 9 cases, by traffic accident in 5 cases, and by falling in 2 cases. The average interval from injury to admission was 8 hours (range, 1-48 hours). Routine X-ray and CT scan were taken for confirmation of classification and involvement. According to Weber classification system, 11 cases were rated as type A, and 5 as type B; 5 cases had bimalleolar fractures with medial malleolar fracture, and 2 cases had trimalleolar fractures with posterior and medial malleolar fracture. Open reduction and dual plating fixation were performed after swelling was subsided. The X-ray films were taken during follow-up. The effectiveness was evaluated with visual analogue scale (VAS) and American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot and ankle score system at last follow-up. The range of motion (ROM) of the ankle and complications were also been recorded. ResultsDelayed healing of incision occurred in 1 patient with diabetes, who was cured after changing dressing; primary healing was obtained in the other patients. Twelve patients were followed up 18 months on average (range, 12-24 months). Radiographic examination demonstrated the mean time of bone healing was 12 weeks (range, 10-14 weeks). No complication of implant failure, malunion, nonunion, or post-traumatic arthritis occurred during follow-up. The AOFAS hindfoot and ankle score was 79.6±6.5, and the VAS score was 1.3±1.5. The ROM of the ankle was (70.0±8.0)° of flexion and (84.0±5.1)° of extension. ConclusionDual plating fixation for distal fibular comminuted fractures can obtain a rigid stabilization with a low complication incidence, so it is a safe and effective method.

    Release date: Export PDF Favorites Scan
  • PRELIMINARY APPLICATION OF THREE-DIMENSIONAL PRINTING PERSONALIZED EXTERNAL FIXATOR IN SERIOUS TIBIOFIBULA FRACTURES

    ObjectiveTo explore a new method of treating serious tibiofibula comminuted fracture by using three-dimensional (3-D) printing personalized external fixator. MethodsIn April 2015, a male patient (aged 18 years with a height of 171 cm and a weight of 67 kg) with left tibiofibula comminuted fracture was included in the study. Computer-assisted reduction technique combined with 3-D printing was used to develop a customised personalized external fixator for fracture reduction. The effectiveness was observed. ResultsThe operation time was about 10 minutes without fluoroscopy, and successful reduction was obtained. The patient had equal limb length after operation. X-ray films showed that the posterior angulation of distal fracture was corrected 37°, and the eversion angle was corrected 4°. The tibial fractures had good paraposition or alignment, and the lower limb force line was corrected completely. No new fracture displacement occurred. The clinical healing time of fracture was 3.5 months and the bone union was achieved after 8 months. The function of affected limb recovered well after operation. ConclusionA personalized external fixator for serious tibiofibula comminuted fracture reduction made by 3-D printing technique has the merits of easy manipulation, high individuation, accurate reduction, stable fixation, and no need of fluoroscopy.

    Release date: Export PDF Favorites Scan
  • 切开复位内固定治疗桡骨头粉碎性骨折

    目的 总结采用切开复位内固定治疗桡骨头粉碎性骨折的临床疗效。 方法 对2002 年1 月- 2006年6 月收治的15 例桡骨头粉碎性骨折采用切开复位内固定治疗。男11 例,女4 例;年龄21 ~ 45 岁。左侧10 例,右侧5 例。伤后至手术时间1 ~ 10 d,平均5.3 d。按照Mason 分型均为Ⅲ型。 结果 术后未见关节感染、神经损伤、金属异物反应、腕部畸形等并发症。术后患者均获随访,随访时间1 ~ 4 年,平均2.3 年。骨折均于术后6 个月内达骨性愈合。肘关节功能根据Broberg 和Morrey 评分标准进行评分,优5 例,良7 例,可2 例,差1 例,优良率为85.71%。 结论 切开复位内固定治疗桡骨头粉碎性骨折可获得良好的疗效。

    Release date:2016-09-01 09:19 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content