west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "瓣中瓣" 19 results
  • 经导管主动脉瓣置换术中瓣膜假体脱位紧急瓣中瓣植入一例

    Release date:2025-02-25 09:39 Export PDF Favorites Scan
  • Clinical research status and progress of redo-transcatheter aortic valve replacement for structural biovalvular degeneration

    Biological valves can lead to structural valve degeneration (SVD) over time and due to various factors, reducing their durability. SVD patients need to undergo valve replacement surgery again, while traditional open chest surgery can cause significant trauma and patients often give up treatment due to intolerance. Research has shown that as an alternative treatment option for reoperation of thoracic valve replacement surgery, redo-transcatheter aortic valve replacement for SVD is safe and effective, but still faces many challenges, including prosthesis-patient mismatch, high cross valve pressure difference, and coronary obstruction. This article aims to review the strategies, clinical research status and progress of redo-transcatheter aortic valve replacement in SVD patients.

    Release date:2024-02-29 12:02 Export PDF Favorites Scan
  • Preliminary exploration of the domestic balloon-expandable valve in the treatment of degenerated tricuspid bioprosthetic valve via transcatheter "valve-in-valve" technology

    ObjectiveTo discuss the operation skill and clinical effects of using domestic balloon-expandable Prizvalve® transcatheter "valve-in-valve" to treat the degenerated bioprosthesis in the tricuspid position.MethodsAll the admitted surgical tricuspid valve bioprosthetic valve replacement patients were evaluated by computerized tomography angiography (CTA), ultrasound, and 3D printing technology, and 2 patients with a degenerated bioprosthesis were selected for tricuspid valve "valve-in-valve" operation. Under general anesthesia, the retro-preset Prizvalve® system was implanted into degenerated tricuspid bioprosthesis via the femoral vein approach under the guidance of transesophageal echocardiographic and fluoroscopic guidance.ResultsTranscatheter tricuspid valve implantation was successfully performed in both high-risk patients, and tricuspid regurgitation disappeared immediately. The operation time was 1.25 h and 2.43 h, respectively. There was no serious complication in both patients, and they were discharged from the hospital 7 days after the operation.ConclusionThe clinical effect of the degenerated tricuspid bioprosthetic valve implantation with domestic balloon-expandable valve via femoral vein approach "valve-in-valve" is good. Multimodality imaging and 3D printing technology can safely and effectively guide the implementation of this innovative technique.

    Release date:2021-07-28 10:22 Export PDF Favorites Scan
  • Valve-in-valve transcatheter mitral valve replacement for the treatment of degenerated mitral bioprostheses: a case report

    Surgical bioprosthetic valve in the mitral position typically degenerates in 10-15 years, when intervention is required again. In the past, redo surgical mitral valve replacement has been the only treatment choice for such patients suffering from bioprosthetic valve failure, despite the even higher risk associated with redo open-heart surgery. In recent years, transcatheter valve-in-valve implantation in the mitral position has evolved as an reasonable alternative to redo surgery for the treatment of surgical mitral bioprosthetic valve failure. Here we report an 81-year-old female patient with surgical mitral bioprosthetic valve failure, who successfully underwent valve-in-valve transcatheter mitral valve replacement via the transfemoral-transseptal approach. The procedure was successful owing to comprehensive CT imaging work-up, despite the technical challenges associated with bilateral giant atria and small left ventricle.

    Release date:2024-10-25 01:48 Export PDF Favorites Scan
  • Emergency transcatheter aortic valve replacement for surgical bioprosthesis structural valve degeneration: a case report

    “Valve-in-valve” technique is an effective method to treat the bioprosthesis structural valve degeneration. In this paper, an 82-year-old male patient with severe aortic valve regurgitation had underwent surgical aortic valve replacement. He had a bioprosthesis structural valve degeneration which caused severe aortic stenosis more than 3 years after surgery. His symptoms of chest distress and short breath were aggravated progressively, and not relieved by conventional treatment. As the deterioration in his unstabled circulation system, an emergency transcatheter aortic valve replacement was conducted for him. The operation was finally successful, the symptoms were relived significantly after operation, and then the follow-up indicated that he had a good recovery.

    Release date:2022-05-24 03:47 Export PDF Favorites Scan
  • Transapical transcatheter valve-in-valve implantation treatment for patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement

    ObjectiveTo determine the clinical efficacy of transapical transcatheter mitral valve-in-valve treatment for patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement.MethodsThe clinical data of 9 patients who underwent transapical transcatheter mitral valve-in-valve implantation after aortic-mitral double valve replacement due to mitral bioprosthesis deterioration from May 2020 to January 2021 in our hospital were retrospectively analyzed, including 4 males and 5 females with a mean age of 72.44±7.57 years.ResultsSurgeries were performed successfully in all patients with no conversion to median sternotomy. The mean procedural time was 101.33±48.49 min, the mechanical ventilation time was 23.11±26.54 h, the ICU stay was 1.89±1.05 d and the postoperative hospital stay was 6.11±2.02 d. Residual mild mitral regurgitation was only observed in 1 patient. Only 1 patient needed postoperative blood transfusion. No major complications were observed in all patients. There was no death in postoperative 90 days.ConclusionFor patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement, transapical transcatheter mitral valve-in-valve implantation achieves good clinical results and effectively improves the hemodynamics without increasing the risk of postoperative left ventricular outflow tract obstruction. The surgery is feasible and effective.

    Release date:2021-07-28 10:22 Export PDF Favorites Scan
  • Transcatheter valve-in-valve implantation using the J-Valve for bioprosthetic degeneration at different anatomic positions: A single-center experience

    Objective To summarize the early results and clinical experience of using the J-Valve for transcatheter valve-in-valve implantation in patients with degenerated bioprosthesis at different anatomic positions. Methods A retrospective analysis was conducted to evaluate the short-term outcomes of 39 consecutive patients who underwent transcatheter valve-in-valve implantation using the J-Valve System in the Department of Cardiac Surgery of Guangdong Provincial People’s Hospital from April 2020 to August 2021 due to bioprosthetic degeneration at different anatomic positions. Among them, 35 patients underwent transcatheter mitral valve-in-valve (TMViV) implantation, 1 transcatheter aortic valve-in-valve (TAViV) implantation, 1 transcatheter tricuspid valve-in-valve (TTViV) implantation, 1 TMViV implantation with simultaneous TAViV implantation, and another one TMViV implantation with simultaneous transcatheter aortic valve replacement (TAVR) and perivalvular leakage (PVL) closure. Results Among the 35 patients who underwent isolated TMViV implantation, 17 were male and 18 were female with a mean age of 72.6±10.8 years. Mean duration between two operations was 10.5±2.7 years. The mean Society of Thoracic Surgeons and EuroSCORE Ⅱ scores were 12.95%±9.61% and 13.91%±8.94%, respectively. The device success rate was 97.1% and no death occured during the operation. One patient was transferred to thoracotomy due to device displacement, 1 was re-opened for uncontrolled bleeding, and 1 presented left ventricular outflow tract obstruction. One patient underwent craniotomy due to intracranial hemorrhage within 30 days after surgery, and no other complications occurred including death, stroke, permanent pacemaker implantation, cardiac tamponade, or re-hospitalization. The mean follow-up time was 6.0±4.4 months, the mean mitral valve gradient was significantly improved (10.4±2.0 mm Hg vs. 5.5±1.2 mm Hg, P<0.05), and the New York Heart Association class≤Ⅱ in all the patients at the last follow-up. Among the other 4 patients who did not undergo isolated TMViV implantation, the transapical TAViV implantation and the trans-right atrium TTViV implantation were successful without intra- or post-operative complications. The patient who underwent TMViV and TAViV implantation simultaneously via transapical approach died of severe pulmonary hemorrhage and multiple organ failure 16 days after surgery. The other patient who underwent transapical TMViV combined with TAVR and PVL closure died of septic shock 10 days after the surgery. Conclusion Transcatheter valve-in-valve implantation using the J-Valve system is shown to be a safe and effective procedure to treat mitral, aortic and tricuspid bioprosthetic valve dysfunction in high-risk patients, providing a new alternative to surgical surgery for degenerated bioprosthesis at different anatomic positions. However, simultaneous different valves intervention should be very cautious.

    Release date:2022-11-22 02:01 Export PDF Favorites Scan
  • Assessment of perioperative pulmonary fluid volume using remote dielectric sensing (ReDSTM) non-invasive lung fluid measurement technology in transcatheter tricuspid valve-in-valve implantation: The first case report

    One of its primary surgical treatments of tricuspid regurgitation is tricuspid valve biological valve replacement. Catheter tricuspid valve-in-valve implantation is a novel interventional alternative for biological valve failure. The non-invasive lung fluid measuring device remote dielectric sensing (ReDSTM) has been increasingly incorporated into clinical practice as a means of monitoring chronic heart failure in recent years. This report describes the process and outcomes of the first instance of perioperative lung fluid volume evaluation following transcatheter tricuspid valve implantation utilizing ReDSTM technology. The patient has a short-term, substantial increase in postoperative lung fluid volume as compared to baseline.

    Release date:2025-04-02 10:54 Export PDF Favorites Scan
  • Early and Mid-term Outcomes of Morphologic Tricuspid Valve Replacement with Preservation of Entire Valvular and Subvalvular Apparatus in Corrected Transposition of Great Arteries

    Abstract: Objective To investigate the early and mid-term outcomes of morphologic tricuspid valve replacement by means of intravalvular implantation in corrected transposition of great arteries(cTGA). Methods From January 2009 to January 2012,11 patients with cTGA were surgically treated in Fu Wai Hospital. There were 9 male patients and 2 female patients with their mean of age of(37.8±11.7)years and mean body weight of(73.0±11.3)kg. All the patients underwent morphologic tricuspid valve replacement with preservation of the entire valvular and subvalvular apparatus. Simultaneous surgical procedures included repair of ventricular septal defect in 2 patients,repair of atrial septal defect in 4 patients,pulmonary valvuloplasty in 1 patient,reconstruction of functional right ventricular outflow tract in 4 patients and repair of coronary-pulmonary artery fistula in 1 patient. Postoperative New York Heart Association (NYHA) classification, cardiothoracic ratio, morphological right ventricle ejection fraction, end-diastolic dimension of morphological right ventricle and left atrium were evaluated during follow-up. Results All the 11 patients were successfully surgically treated and followed up for an average duration of(13.0±10.6)months. There was no statistical difference between postoperative and preoperative average cardiothoracic ratio (0.54±0.06 vs. 0.57±0.09,t=1.581,P>0.05),morphologic right ventricle ejection fraction (52.8%±9.0% vs. 54.9%±9.5%, t =0.712,P>0.05),and end-diastolic dimension of . morphological right ventricle (54.3±7.5 mm vs. 56.9±9.2 mm,t =0.988,P>0.05). There was statistical difference between postoperative and preoperative average end-diastolic dimension of left atrium(42.1±8.9 mm vs. 53.4±11.1 mm,t =3.286,P<0.05)and NYHA classification(Z = -2.640,P<0.05). Conclusion Intravalvular implantation of morphologic tricuspid prosthesis can protect the physiological structure of morphologic right ventricular and prevent furtherdamage to its function caused by morphologic tricuspid valve insufficiency. Postoperative dimension of morphologic left atrium and cardiac function are significantly improved. The early and mid-term outcomes are satisfactory.

    Release date:2016-08-30 05:50 Export PDF Favorites Scan
  • Clinical efficacy of valve-in-valve transcatheter mitral valve replacement for degenerated mitral surgical bioprostheses

    Objective To evaluate the clinical efficacy of valve-in-valve transcatheter mitral valve replacement for the management of degenerated bioprosthetic mitral valves. Methods This study retrospectively analyzed the clinical data of patients who underwent transcatheter mitral valve replacement due to degenerated bioprosthetic mitral valves at the First Affiliated Hospital of Zhengzhou University from 2020 to 2023. The analysis included baseline characteristics, surgical details, perioperative complications, and hemodynamic changes during the early postoperative period and subsequent follow-up. Results A total of 31 patients were included in the study, comprising 7 males and 24 females, with an average age of (66.57±9.32) years. The average duration since the initial surgical placement of the bioprosthetic valves was (9.92±3.71) years. The procedures included 7 patients utilizing the transfemoral venous-atrial septal approach and 24 patients employing the transapical approach. All patients exhibited significant improvement in cardiac function postoperatively, with a reduction in the number of patients classified as New York Heart Association (NYHA) grade Ⅲ or Ⅳ and those with moderate to severe tricuspid valve regurgitation. Echocardiographic assessments revealed a decrease in peak flow velocity across the mitral valve and a reduction in the average transvalvular pressure gradient, while left ventricular ejection fraction remained unchanged. One patient experienced a recurrent stroke and died on the fifth postoperative day; however, the remaining patients were discharged without complications, including cardiac death, all-cause mortality, or outflow tract obstruction. During a median follow-up period of 12 months, no adverse events were reported, and hemodynamic stability was maintained. Conclusion Valve-in-valve transcatheter mitral valve replacement is a safe and effective option for patients with degenerated bioprosthetic mitral valves, demonstrating favorable hemodynamic outcomes and satisfactory short-term clinical results.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content