目的:探讨电子支气管镜在肺癌诊断中的价值。方法:对233例支气管镜下诊断肺癌的患者进行分析。结果:电子支气管镜下肺癌的诊断率为63.49%,其中中央型肺癌的诊断率为72.85%,周围型肺癌的诊断率为27.63%,该组病例以老年人多见, 肿瘤多位于叶支气管,右肺57.51%, 左肺42.49%,病理类型为鳞癌45.92%, 小细胞癌22.75%, 腺癌24.03%。电子支气管镜下主要特征:鳞癌以管内增殖型改变为主,表现为新生物形成,阻塞管腔,伴有糜烂、充血、水肿,小细胞癌以增殖型和浸润型为主,可见气管内新生物形成及节结样改变。腺癌以管内增殖型和肿块压迫管腔为主,可见管内新生物形成或支气管呈缝隙样狭窄,甚至闭塞。结论:与周围型肺癌相比电子支气管镜检查对中心型肺癌诊断的准确率较高, 其检查方法简单, 创伤性小, 是正确指导临床医生选择合理治疗方法的一种较好的辅助检查技术。
ObjectiveTo investigate the clinical efficacy of preoperative location of pulmonary nodules guided by electromagnetic navigation bronchoscopy (ENB). MethodsPatients who received preoperative ENB localization and then underwent surgery from March 2021 to November 2022 in the Department of Thoracic Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine were collected. The clinical efficacy and safety of ENB localization and the related factors that may affect the success of ENB localization were analyzed. ResultsInitially 200 patients were included, among whom 17 undergoing preoperative localization and biopsy were excluded and a total of 183 patients and 230 nodules were finally included. There were 62 males and 121 females with a mean age of 49.16±12.50 years. The success rate of navigation was 88.7%, and the success rate of ENB localization was 67.4%. The rate of complications related to ENB localization were 2.7%, and the median localization time was 10 (7, 15) min. Multi-variable analysis showed that factors related to successful localization included distance from localization site (OR=0.27, 95%CI 0.13-0.59, P=0.001), staining material (OR=0.40, 95%CI 0.17-0.95, P=0.038), and staining dose (OR=60.39, 95%CI 2.31-1 578.47, P=0.014). Conclusion ENB-guided preoperative localization of pulmonary nodules is safe and effective, and the incidence of complications is low, which can be used to effectively assist the diagnosis and treatment of early lung cancer.
目的探讨肋骨骨折导致的创伤性肺不张治疗中应用电子支气管镜肺段灌洗治疗的效果 方法回顾性分析新疆医科大学第六附属医院2009年10月至2013年4月肋骨骨折导致创伤性肺不张73例行电子支气管镜肺段灌洗治疗患者的临床资料,其中男52例、女21例,年龄29~83(36± 5)岁。按治疗方式将患者分为两组:灌洗组(37例)行电子支气管镜肺段灌洗,对照组(36例)采用肺不张的常规治疗。比较两组临床效果。 结果灌洗组呼吸频率及心率减慢,动脉血氧饱和度升至95%以上,肺复张明显好于对照组,差异有统计学意义(P < 0.05)。 结论电子支气管镜肺段灌洗治疗肋骨骨折导致的创伤性肺不张直视下诊断明确,起效快,创伤小,疗效确切。
目的:评价电子气管镜直视下置入镍钛合金支架治疗气道狭窄的疗效及安全性。方法:对我院3年来由各种原因引起的气管或支气管狭窄的21例患者行电子气管镜直视下经鼻置入国产镍钛合金支架术,观察置入支架前后症状、狭窄段气道直径变化、动脉血气变化情况及其并发症。结果:21例患者术后呼吸困难均明显改善,气道内径扩张及动脉血氧分压改善较术前均有统计学意义,未发生严重并发症。结论:电子气管镜直视下置入气道支架准确、迅速、安全,操作较方便,有助于延长患者的生存时间和提高生活质量,为进一步治疗创造条件。
Objective To explore the safety and efficacy for patients with central airway-pleural fistula (APF) treated by atrial septal defect (ASD) occluder. Methods This was a retrospective study. Between January 2017 and October 2021, a total of 16 patients with postoperative APF were treated with ASD occluder through bronchoscope under local anesthesia combined with sedation. The efficacy and complication were recorded during and after the procedure. Results Sixteen patients were recruited in this study and the average age was 60.7 years (range 31 - 74 years). The main etiology for APF was lobectomy/segmentectomy (n=12), pneumonectomy (n=2), radical esophagectomy (n=1) or decortication for chronic empyema (n=1). Totally, 4 fistulas were located in right main bronchus, 3 in left main bronchus, 3 in right upper bronchus, 1 in right middle bronchus, 2 in right lower bronchus and 3 in left upper bronchus. The median diameter of APF was 7.8 mm (ranged from 4 to 18 mm) and the median diameter of ASD occluder inserted was 10.0 mm (ranged from 6 to 20 mm). Successful occlusion of APF was observed in 15 patients (15/16) and 1 patient died of multiple organ failure caused by bacteremia 14 days after the procedure. Fourteen patients were recruited for long-term follow-up, on a median follow-up period of 16.2 months (ranged from 3 to 46 months). There were 12 patients of complete remission and 2 patients of partial remission and only one patient took a second operation due to the enlargement of fistula and translocation of occluder. At follow-up, 4 patients died and the reasons were directly related to the primary etiology, and no patient died due to APF recurrence. Conclusion Endobronchial closure of central APF using ASD occluder is a minimally invasive but effective modality of treatment with satisfactory long-term outcome.
ObjectiveTo evaluate the clinical efficacy of balloon bronchoplasty and metallic stents in lung transplant-related central airway stenosis.MethodsData of lung transplant recipients with central airway stenosis who underwent therapeutic bronchoscopic interventions between January 2011 and June 2019 at our institution were reviewed. The clinical follow-up included dyspnea index, forced expiratory Forced expiratory volume in one second (FEV1), six-minute walk distance (6MWD), and the rate of bronchoscopic dilation.ResultsThirty-four lung transplant recipients with airway stenosis were included in our study. All these patients were treated by balloon bronchoplasty through flexural bronchoscopy, and 7 additionally needed temporary metal stent implantation for 28 to 67 days in order to palliate recurrent central airway stenosis. The percentages of immediate efficacy were 86% (180/209) and 100% (7/7), respectively. After serial balloon dilatation, the recipients with central airway stenosis had significantly lower dyspnea index (3.24±0.55 vs. 1.91±0.62, P<0.01), higher FEV1 [(1.43±0.21)L vs. (1.72±0.27)L, P<0.01] and longer 6MWD [(317.3±61.7)m vs. (372.9±52.6)m, P<0.01]. Six recipients with central airway stenosis received 33 interventions in 6 months before stent implantation and 10 interventions in 6 months after stent extraction.ConclusionsLung transplant recipients with central airway stenosis have a good respond to balloon bronchoplasty and stent placement. Airway stenosis after lung transplantation can be successfully managed with bronchoscopic dilatation and temporary stent placement.