find Author "李真林" 35 results
  • 双源CT诊断肺动脉吊带畸形一例

    Release date:2016-09-08 09:27 Export PDF Favorites Scan
  • Influence of the abduction angle of the double upper limbs on liver non-enhanced CT image quality in patients with vehicle accident

    ObjectivesTo investigate the influence of the abduction angle of the upper extremities on the image quality of non-enhanced CT scan and clinical value of the patients who cannot lift with double upper limbs by vehicle accident.Methods60 patients with double upper limbs that could not lift by vehicle accidents were required to receive liver non-enhanced CT scan, the patients were divided into 3 groups according to the abduction angle (group A, B, C), 20 cases in each group, another 20 cases with standard pose as the control group (group D). The CT value and standard deviation of the liver region of interest, the erector and the background air were measured, and the contrast to noise ratio of liver images, image noise value were calculated, together with the assessment of image quality and statistic analysis.ResultsThe liver non-enhanced CT scan were completed successfully. The image quality of group D was significantly better than A, B, C (Z=–10.753, P<0.05;Z=–11.645, P<0.05;Z=–12.281, P<0.05), respectively. Group C was better than A and B (Z=–8.502, P<0.05;Z=–4.068, P<0.05), respectively. Group B was better than A (Z=–5.885, P<0.05). The CNR of the four groups of images increased gradually, group A (0.09±0.77), group B (1.56±0.83), group C (2.51±0.87), group D (2.59±0.97), respectively. There were significant differences between four groups (F=36.323, P<0.05). The image noise decreased systematically, group A (14.84±2.94), group B (13.04±1.59), group C (11.60±1.72), group D (10.44±1.13), respectively. There were significant differences between four groups (H=426.755, P<0.05).ConclusionOn the premise of safety inspection, with the enlargement of angle of the upper limbs of patients who cannot lift with double upper limbs by vehicle accidents, the image noise decreased and image quality is improved with the increase of signal noise ratio.

    Release date:2018-06-04 08:52 Export PDF Favorites Scan
  • The Application of 70 kV and Sonogram-affirmed Iterative Reconstruction Technique in CT Examination for Children with Congenital Heart Disease

    ObjectiveTo evaluate the value of 70 kV and sonogram-affirmed iterative reconstruction technique in CT examination for children with congenital heart disease. MethodsThirty children with congenital heart disease who underwent CT scan between January and September 2014 were included in this study. According to the different tube voltage, they were randomly divided into group A (80 kV) and group B (70 kV), with fifteen in each. All the children were scanned on a dual-source-CT (Siemens Definition Flash). Group A used filtered back projection reconstruction. Group B used sonogram-affirmed iterative reconstruction. We measured and calculated the pulmonary artery signal-to-noise ratio at the level of main pulmonary artery window, the signal-to-noise ratio of the ascending aorta, noise ratio contrast between the pulmonary artery and erector spinae and between the ascending aorta and erector spinae. The image quality for congenital heart disease was assessed by two senior radiologists. The measurement of radiation dose included effective dose (ED), volume CT dose index (CTDIvol) and dose length product (DLP). ResultsThere were no significant differences between group A and B in terms of pulmonary artery signal-to-noise ratio (14.54±3.77, 11.23±2.52), the signal-to-noise ratio of the ascending aorta (14.76±3.41, 12.31±3.47), the noise ratio contrast between pulmonary artery and erector spinae (12.04±3.96, 9.18±3.76) and between the ascending aorta and erector spinae (12.47±4.59, 9.77±4.41) (P > 0.05). There was significant difference between group A and group B in CTDIvol[(0.53±0.09), (0.38±0.03) mGy], DLP[(12.93±1.79), (6.67±0.72) mGy·cm], and ED[(0.34±0.05), (0.17±0.02) mSv] (P < 0.05). ConclusionThe application of 70 kV and sonogram-affirmed iterative reconstruction technique in CT examination for children with congenital heart disease can significantly reduce the radiation dose without any influence on image quality.

    Release date: Export PDF Favorites Scan
  • MRI常规扫描及弥散加权成像在宫颈癌评价中的价值

    MRI常规扫描凭借着较高的软组织分辨率对宫颈癌肿块在宫颈内部的生长情况、肿块对宫体的侵犯程度以及对宫旁癌周的侵犯、宫旁闭孔区淋巴结转移的评价方面具有较高准确性和特异性。MRI常规扫描可提高宫颈癌的定位、定性、分期的准确性,有助于临床国际妇产科联盟(FIGO)分期。MRI弥散加权成像,作为功能磁共振的一种,是唯一一种可以评价活体组织内水分子弥散状况的扫描方法,利用弥散加权成像获得表观弥散系数值可以对宫颈癌病灶组织病理学类型及分化程度、宫旁侵犯、淋巴结转移进行定量定性分析。将弥散加权成像与常规扫描结合起来在诊断宫颈癌、协助临床FIGO分期、制订优化个体化治疗方案及预后预测上有较大临床应用价值。

    Release date: Export PDF Favorites Scan
  • 多层螺旋CT辐射剂量控制与监督的临床意义

    【摘要】 多层螺旋CT检查已经成为临床诊断疾病的重要检查手段,然而CT检查产生的辐射剂量也越来越得到研究人员的关注。通过对MSCT辐射剂量的影响因素,降低MSCT辐射剂量的方法,合理选用CT检查,规范化设置CT检查方案,普及辐射防护知识,形成有效管理监督机制的论述、分析,探讨MSCT辐射剂量控制与监督的临床价值。

    Release date:2016-09-08 09:50 Export PDF Favorites Scan
  • Application of Single-dose Contrast-enhanced Magnetic Resonance in Carotid Arteriography

    目的 探讨常规注射速率下单倍剂量对比剂在颈部三维对比增强磁共振血管成像(3D-CEMRA)中的可行性及临床应用价值。 方法 2011年8月-11月,连续纳入30例临床怀疑颈动脉或椎动脉狭窄并要求颈部磁共振血管成像检查的患者,随机分成A、B两组(每组各15例)。使用西门子Magnetom Avanto 1.5 T磁共振成像仪及其配备的颈部线圈和头部线圈进行CEMRA成像。A组使用双倍剂量对比剂(0.2 mmol/kg),B组使用单倍剂量对比剂(0.1 mmol/kg)。用三维快速小角度激发序列进行颈部血管成像。由2位有丰富经验的高年资医生对两组原始图像的信噪比以及最大密度投影(MIP)图像的质量进行评价,并对结果进行统计学分析和处理。 结果 A、B两组的所颈动脉信噪比分别为189.95 ± 71.31、175.07 ± 68.61,差异无统计学意义(t=?0.566,P=0.576);所得的MIP图像质量均达到优良,差异无统计意义(χ2=0.180,P=0.671)。 结论 与双倍剂量相比,单倍剂量对比剂获得颈部血管的图像清晰,能够满足临床诊断要求。

    Release date:2016-09-08 09:16 Export PDF Favorites Scan
  • The progress in imaging evaluation of liver iron concentration

    ObjectiveTo summarize the methods and research progress of imaging evaluation of liver iron concentration.MethodsThe current status and progress of different imaging techniques in liver iron overload research were reviewed by studying the relevant literatures at home and abroad. The methods for determining liver iron concentration and their advantages and disadvantages were summarized.ResultsThe imaging methods for determining liver iron concentration mainly included traditional non-enhanced CT and dual energy CT examination, magnetic resonance signal intensity ratio, relative signal intensity index, T2 and R2 values, magnetic resonance spectroscopy, T2* and R2* values, susceptibility weighted imaging, and quantitative susceptibility mapping.ConclusionLiver iron quantification imaging method, including dual-energy CT and magnetic resonance imaging could non-invasively and accurately assess the liver iron overload.

    Release date: Export PDF Favorites Scan
  • Value of Multi-slice CT in Assessing the Features of Carotid Artery Plaques

    目的 探讨多层螺旋CT在评价颈动脉斑块特征中的价值。 方法 回顾性分析2011年7月-10月132例行CT颈部血管造影患者的影像资料。对颈动脉斑块特征进行评价,重建方法包括多层面重建、容积再现技术、最大密度投影及曲面重建。 结果 132例患者中,80例检出颈动脉斑块,最常出现钙化斑块的部位为海绵窦段和床突上段,右侧海绵窦段52例(65.0%)、左侧海绵窦段49例(61.3%),右床突上段37例(46.3%)、左侧床突上段30例(37.5%)。最常出现软斑块的部位为双侧颈总动脉,均为12例(15.0%)。最常出现混合斑块的部位为颈总动脉,右侧颈总动脉9例(11.3%)、左侧颈总动脉12例(15.0%)。颈动脉最容易轻度狭窄294处(294/1 440,20.4%),中、重度狭窄少见,分别为8处(8/1 440,0.5%)和6处(6/1 440,0.4%)。颈部动脉血管斑块最易出现钙化,总计249处(249/1 440,17.3%),其次是软斑块和混合斑块,均为39处(39/1 440,2.7%)。 结论 多层螺旋CT可准确评价颈动脉斑块特征。

    Release date:2016-09-08 09:18 Export PDF Favorites Scan
  • Assessment of Low-Dose Radiation in Coronary Artery Imaging by 64-Slices Multi-detector CT

    【摘要】 目的 评价64层螺旋CT低剂量冠状动脉血管成像的价值。 方法 2009年1-6月157例患者随机分为3组,常规剂量组(A组)管电流量采用1 000 mAs,两个低剂量组(B、C组)分别采用800、600 mAs。对3组的图像质量、噪声、CT剂量指数(CTDI)、剂量长度乘积(DLP)和有效剂量(ED)进行评估。 结果 A、B、C组图像噪声分别为20.50±3.23、23.02±3.05和26.28±2.58,组间差异均无统计学意义(Pgt;0.05);A、B、C组的CTDI分别为(58.7±0.23)、(46.98±2.27)、(35.28±3.56) mGy,DLP分别为(1 050.88±89.63)、(846.21±57.86)、(641.13±32.15) mGy?cm,ED分别为(14.78±2.56)、(11.85±1.87)、(8.98±1.15) mSv,B、C组的CTDI、DLP、ED均明显低于常规剂量A组(Plt;0.05),C组的CTDI、DLP、ED均为3组中最低值。 结论 64层螺旋CT冠状动脉血管检查,采用600 mAs管电流量获得的冠脉图像既可满足诊断需要,又可使患者接受的辐射剂量降低。【Abstract】 Objective To evaluate the best tube current for low-dose radiation CT in coronary artery imaging by 64-slices multi-detector CT. Methods From January to June 2009, a total of 157 consecutive patients were randomly divided into 3 groups: group A (conventional group): 1 000 mAs; group B: 800 mAs; group C: 600 mAs. The image quality, noise, CT dose index (CTDI), dose length product (DLP) and effective dose (ED) in each group were measured and compared respectively. Results The image noise scores in group A, B, and C were (20.50±3.23), (23.02±3.05) and (26.28±2.58), respectively. There was no statistically significant difference among the three groups in the two indexes (Pgt;0.05). The CTDI in group A, B and C were (58.7±0.23), (46.98±2.27), and (35.28±3.56) mGy, respectively; the DLP in each were (1 050.88±89.63), (846.21±57.86), and (641.13±32.15) mGy?cm, respectively; the Ed were (14.78±2.56), (11.85±1.87), and (8.98±1.15) mSv, respectively. All of the differences among the three groups in CTDI, DLP and ED were statistically significant (Plt;0.05). Conclusion The image with 600 mAs as tube current in the coronary artery imaging of 64-slices multi-detector CT could fulfill the need of the diagnosis, and the radiation dose is apparently lower than the conventional scan.

    Release date: Export PDF Favorites Scan
  • 迭代重建技术降低踝关节内固定金属伪影的价值

    目的 探讨迭代重建(iterative reconstruction,IR)技术在踝关节金属内固定术后数字化断层融合(digital radiographic tomosynthesis,DTS)检查中的临床应用价值。 方法 2014 年 10 月—2015 年 6 月采用 DTS 技术检查踝关节金属内固定术后复查患者 30 例,每例患者的原始数据分别采用 IR 算法和滤波反投影(filter back projection,FBP)算法进行重建。重建后图像根据图像噪声、内固定金属周围骨质清晰度和失真度,以 3 分法对图像质量进行主观评价,数值越高图像越清晰;测量螺钉伪影长度、螺钉与骨质结合程度作为客观数据评价,数据值越小图像质量越好。 结果 图像噪声、内固定周围骨质清晰度和失真度的主观评分:采用 IR 算法重建的图像中,优片 26 例(86.7%),良片 4 例(13.0%);采用 FBP 算法重建的图像中,优片 3 例(10.0%),良片 27 例(90.0%);两种算法重建图像优质率差异有统计学意义(χ2=21.043,P<0.001)。两种算法重建图像均无螺钉伪影。IR 算法重建图像螺钉与骨质结合紧密,间隙度为 0 mm;FBP 算法重建图像螺钉与骨质结合间隙度为 0.2~0.3 mm,系金属硬化束伪影。 结论 DTS 扫描 IR 技术能有效降低踝关节内固定金属伪影,图像质量明显优于 FBP 重建图像,踝关节金属内固定 DTS 检查 IR 技术有较高的临床应用价值。

    Release date:2017-03-27 11:42 Export PDF Favorites Scan