west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "机器人" 300 results
  • Simulation design and experimental study of magnetic stimulation coil for robot pigeon

    To explore the feasibility of applying magnetic stimulation technology to the movement control of animal robots, the influence of coil radius, number of turns and other factors on the intensity, depth and focus of magnetic stimulation was simulated and analyzed for robot pigeons. The coil design scheme was proposed. The coil was placed on the head and one of the legs of the pigeon, and the leg electromyography (EMG) was recorded when magnetic stimulation was performed. Results showed that the EMG was significantly strengthened during magnetic stimulation. With the reduction of the output frequency of the magnetic stimulation system, the output current was increased and the EMG was enhanced accordingly. Compared with the brain magnetic stimulation, sciatic nerve stimulation produced a more significant EMG enhancement response. This indicated that the magnetic stimulation system could effectively modulate the functions of brain and peripheral nerves by driving the coil. This study provides theoretical and experimental guidance for the subsequent optimization and improvement of practical coils, and lays a preliminary theoretical and experimental foundation for the implementation of magnetic stimulation motion control of animal robots.

    Release date:2023-02-24 06:14 Export PDF Favorites Scan
  • Progress and prospect of robotic cardiac surgery

    Minimally invasive cardiac surgeries are the trend in the future. Among them, robotic cardiac surgery is the latest iteration with several key-hole incision, 3-dimentional visualization, and articulated instrumentation of 7 degree of ergonomic freedom for those complex procedures in the heart. In particular, robotic mitral valve surgery, as well as coronary artery bypass grafting, has evolved over the last decade and become the preferred method at certain specialized centers worldwide because of excellent results. Other cardiac procedures are in various stages of evolution. Stepwise innovation of robotic technology will continue to make robotic operations simpler, more efficient, and less invasive, which will encourage more surgeons to take up this technology and extend the benefits of robotic surgery to a larger patient population.

    Release date:2019-09-18 03:45 Export PDF Favorites Scan
  • Analysis of therapeutic effect of robot-assisted percutaneous screw in the treatment of thoracolumbar fractur

    Objective To explore the clinical effect of PSIS-A robot-assisted percutaneous screw in the treatment of thoracolumbar fracture. Methods Patients with thoracolumbar fracture who were hospitalized in Mianyang Orthopedic Hospital between August 2022 and January 2024 and required percutaneous pedicle screw f ixation were selected. Patients were divided into robot group and free hand group by random number table. Operative time, intraoperative bleeding, intraoperative radiation dose and time, implant accuracy rate, small joint invasion rate, Visual Analogue Scale score for pain and other indexes were compared between the two groups. Results A total of 60 patients were included. Among them, there were 28 cases in the robot group and 32 cases in the free hand group. On the third day after surgery, the Visual Analogue Scale score of the robot group was better than that of the free hand group (P=0.003). Except for intraoperative bleeding and radiation frequency (P>0.05), the surgical time, average nail implantation time, and intraoperative radiation dose in the robot group were all lower than those in the free hand group (P<0.05). The accuracy and excellence rate of nail planting in the robot group were higher than those in the free hand group (94.6% vs. 84.9%; χ2=7.806, P=0.005). There was no statistically significant difference in the acceptable accuracy rate (96.4% vs. 91.1%; χ2=3.240, P=0.072) and the incidence of screw facet joint invasion (7.2% vs.14.1%; χ2=3.608, P=0.058) between the two groups. Conclusion The application of PSIS-A type robot assisted percutaneous minimally invasive pedicle screw fixation in the treatment of thoracolumbar fr actures is promising.

    Release date:2024-11-27 02:31 Export PDF Favorites Scan
  • Effect of robotic-arm assisted total knee arthroplasty on femoral rotation alignment and its short-term effectiveness

    ObjectiveTo investigate the improvement of femoral rotation alignment in total knee arthroplasty (TKA) by robotic-arm assisted positioning and osteotomy and its short-term effectiveness.MethodsBetween June 2020 and November 2020, 60 patients (60 knees) with advanced osteoarthritis of the knee, who met the selection criteria, were selected as the study subjects. Patients were randomly divided into two groups according to the random number table method, with 30 patients in each group. Patients were treated with robotic-arm assisted TKA (RATKA) in trial group, and with conventional TKA in control group. There was no significant difference in gender, age, side and course of osteoarthritis, body mass index, and the preoperative hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), posterior condylar angle (PCA), knee society score-knee (KSS-K) and KSS-function (KSS-F) scores between the two groups (P>0.05). The clinical (KSS-K, KSS-F scores) and imaging (HKA, LDFA, MPTA, PCA) evaluation indexes of the knee joints were compared between the two groups at 3 months after operation.ResultsAll patients were successfully operated. The incisions in the two groups healed by first intention, with no complications related to the operation. Patients in the two groups were followed up 3-6 months, with an average of 3.9 months. KSS-K and KSS-F scores of the two groups at 3 months after operation were significantly higher than those before operation (P<0.05), but there was no significant difference between the two groups (P>0.05). X-ray re-examination showed that the prosthesis was in good position, and no prosthesis loosening or sinking occurred. HKA, MPTA, and PCA significantly improved in both groups at 3 months after operation (P<0.05) except LDFA. There was no significant difference in HKA, LDFA, and MPTA between the two groups (P>0.05). PCA in trial group was significantly smaller than that in control group (t=2.635, P=0.010).ConclusionRATKA can not only correct knee deformity, relieve pain, improve the quality of life, but also achieve the goal of restoring accurate femoral rotation alignment. There was no adverse event after short-term follow-up and the effectiveness was satisfactory.

    Release date:2021-07-29 05:02 Export PDF Favorites Scan
  • Application of robot-assisted endoscopic lumbar decompression and fusion in single segment lumbar fusion surgery

    Objective To explore the application of robot-assisted pedicle screw fixation combined with total endoscopic decompression and interbody fusion in single segment lumbar decompression and fusion. Methods A total of 27 cases undergoing single segment lumbar decompression and fusion between August 2020 and May 2021 in the People’s Hospital of Deyang City were retrospectively collected. They were divided into group A and B according to their surgery method. The patients in group A underwent robot-assisted pedicle screw fixation combined with total endoscopic decompression and interbody fusion surgery, while the ones in group B underwent traditional posterior decompression and fusion. The operation time, amount of bleeding, Visual Analogue Scale (VAS) score and Oswestry Disability Index (ODI) score before operation and one month and three months after operation, and success rate of screw placement were compared. Results There were 12 patients in group A, 5 males and 7 females, aged (59.83±6.79) years, and 15 patients in group B, 6 males and 9 females, aged (53.73±14.87) years. The amount of intraoperative bleeding [(195.00±45.23) vs. (240.00±47.06) mL] and postoperative hospital stay [(5.92±1.56) vs. (8.33±3.62) d] in group A were less than those in group B (P<0.05), while the operation time [(185.80±52.13) vs. (160.70±21.37) min] and the success rate of screw placement [100.0% (48/48) vs. 96.7% (58/60)] had no statistical difference between the two groups (P>0.05). The VAS score and ODI score of the two groups decreased significantly over time (P<0.05), but there was no significant difference in VAS score between the two groups at the same time point before operation, one month after operation, or three months after operation (P>0.05). The ODI score of group A was better than that of group B one month after operation (P=0.010), but there was no significant difference between the two groups before operation or three months after operation (P>0.05). Conclusion Compared with traditional open surgery, the application of robot-assisted total endoscopic lumbar decompression and fusion technology in single segment lumbar fusion has good early clinical outcome, high success rate of screw placement, and small trauma, which is beneficial to early functional recovery and has the significance of further exploring its application prospect.

    Release date:2022-11-24 04:15 Export PDF Favorites Scan
  • 天玑骨科机器人辅助四角融合经皮螺钉内固定技术介绍

    Release date:2023-06-07 11:13 Export PDF Favorites Scan
  • 机器人辅助下“比基尼”切口直接前入路人工全髋关节置换术治疗强直性脊柱炎骨性融合髋一例

    Release date:2022-05-07 02:02 Export PDF Favorites Scan
  • Research hotspots and trends of robot-assisted orthopedic surgery from 2003 to 2023

    Objective To conduct a systematic bibliometric analysis of recent research on robot-assisted orthopedic surgery, in order to reveal the research trends, hotspots, main contributors, and future development directions in this field. Methods On August 27, 2024, WoSCC (Web of Science Core Collection Database) was searched and relevant literature on robot-assisted orthopedic surgery from 2003 to 2023 was included. Excel 2016, VOSviewer (version 1.6.10), and CiteSpace (version 6.2.R6) were used for data collection and analysis. Results The total citation frequency of 1718 retrieved literature was 28978 times, with an average citation frequency of 16.87 times per article. The total citation frequency of articles in 2019 was the highest (4330 times), and the publication volume in 2023 was the highest (315 articles). Among the top 5 countries in terms of publication volume, the United States had the highest publication volume and total citation frequency, while China ranked second in terms of publication volume, but had the lowest average citation frequency per article. Analysis of cooperation between countries showed that the United States, China, Germany, and other countries had the most cooperation. Babar Kayani’s articles were cited the most frequently. Among the top 10 institutions in terms of publication volume, the Hospital for Special Surgery (United States) had the highest publication volume, the Pennsylvania State System of Higher Education (United States) had the highest total citation frequency for publications, and the average citation frequency of each article published by the University of Pittsburgh (United States) was the highest. The dynamic evolution of research hotspots suggested that early research mainly focused on the combination of traditional surgical techniques and navigation, while in recent years, research had mainly focused on computer-aided surgery, augmented reality, and medical robotics technology. Conclusions In recent years, significant progress has been made in the research of robot-assisted orthopedic surgery, with the United States taking a leading position in this field and having extensive global cooperation. Research hotspots show that with the continuous development of computer-aided surgery, augmented reality, and robotics technology, the field of orthopedic surgery is evolving towards more precise, individualized, and minimally invasive directions.

    Release date:2024-12-27 02:33 Export PDF Favorites Scan
  • Perioperative effects of da Vinci robot with totally no tube versus subxiphoid video-assisted thymectomy surgery for thymic tumors: A retrospective cohort study

    Objective To compare the clinical efficacy and safety of da Vinci robot with totally no tube (TNT) versus subxiphoid video-assisted thymectomy surgery (SVATS) in the treatment of thymic tumors. Methods From 2019 to 2021, a retrospective analysis was conducted on patients with thymic tumor resection in the Department of Thoracic Surgery, General Hospital of Northern Theater Command. All patients underwent total thymectomy and mediastinal fat removal, and they were divided into a TNT group and a SVATS group according to the operation method. The intraoperative blood loss, conversion rate, postoperative visual analogue score (VAS), postoperative hospital stay time and postoperative complications were compared between the two groups. Results We finally included 435 patiets. There were 168 patients with 83 males and 85 females at an average age of 61.920±9.210 years in the TNT group and 267 patients with 147 males and 120 females at an average age of 61.460±8.119 years in the SVATS group. There was no death or postoperative myasthenic crisis in both groups. There was no statistical difference in postoperative hospital stay (1.540±0.500 d vs. 3.400±0.561 d, P=0.000), intraoperative blood loss (13.450±5.498 mL vs. 108.610±54.462 mL, P=0.000), postoperative 24 h VAS score (4.960±1.757 points vs. 3.600±1.708 points, P=0.000), or postoperative complication rate (3.0% vs. 11.6%, P=0.001).Conclusion TNT is a more efficient, safe, and effective surgical approach for treating thymic tumors, which can shorten hospital stay time and reduce postoperative complications. However, SVATS can minimize postoperative pain.

    Release date:2023-06-13 11:24 Export PDF Favorites Scan
  • Clinical effect analysis of three-port Da Vinci robot-assisted radical resection of lung cancer

    ObjectiveTo investigate the clinical effect of three-port Da Vinci robot-assisted radical resection of lung cancer. MethodsThe clinical data of patients who underwent Da Vinci robot-assisted radical resection of lung cancer in the Second Department of Thoracic Surgery, the First Affiliated Hospital of Xiamen University from April 2021 to March 2022 were retrospectively analyzed. According to the number of surgical ports, they were divided into two groups: a three-port group (three-port Da Vinci robot-assisted radical resection of lung cancer), and a four-port group (traditional Da Vinci robot-assisted radical resection of lung cancer). The operation time, intraoperative bleeding, lymphadenectomy, total thoracic drainage, extubation time, postoperative complications and postoperative pain of the two groups were compared and analyzed. ResultsA total of 58 patients were included, including 19 males and 39 females, aged 31-79 years. There were 21 patients in the three-port group, and 37 patients in the four-port group. The visual analogue scores on the first and third day after the operation were 4.33±1.20 points and 2.24±0.77 points in the three-port group, and 5.11±1.22 points and 2.78±1.06 points in the four-port group, and there were statistical differences between the two groups (P<0.05). There was no significant difference between the two groups in terms of operation time, intraoperative bleeding, lymph node dissection, postoperative thoracic drainage, time of thoracic tube insertion or postoperative complications (P>0.05). ConclusionThree-port Da Vinci robot-assisted radical resection of lung cancer can reduce the postoperative pain without increasing the operation difficulty and complications, and can be widely used in the clinical practice.

    Release date:2023-05-09 03:11 Export PDF Favorites Scan
30 pages Previous 1 2 3 ... 30 Next

Format

Content