west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "撕脱骨折" 37 results
  • A comparative study of absorbable screw fixation and absorbable screw combined with suture anchor fixation in treatment of avulsion fracture of posterior cruciate ligament at tibial insertion of knee joint

    ObjectiveTo compare the effectiveness of open reduction of posterior cruciate ligament (PCL) avulsion fracture at tibial insertion of knee joint with absorbable screws fixation and absorbable screw combined with suture anchor fixation. Methods The clinical data of 26 patients with PCL avulsion fracture at tibial insertion who met the selection criteria between March 2015 and October 2021 were retrospectively analyzed. Among them, 14 patients were fixed with simple absorbable screw (group A), and 12 patients were fixed with absorbable screw combined with suture anchors (group B). All patients were confirmed by X-ray film, CT, or MRI preoperatively, and got positive results in preoperative posterior drawer tests. There was no significant difference in gender, age, side of affected limb, time from injury to operation, comorbidities, and preoperative Meyers & McKeever classification, Lysholm score, and International Knee Documentation Committee (IKDC) score between the two groups (P>0.05). The operation time and postoperative complications were recorded and compared between the two groups. At last follow-up, Lysholm score and IKDC score were used to evaluate the improvement of knee function. ResultsThere was no significant difference in operation time between the two groups (P>0.05). All incisions healed by first intention, and no complication such as vascular and nerve injury or venous thrombosis occurred. All 26 patients were followed up 9-89 months, with an average of 55.3 months. The follow-up time of group A and group B was (55.7±23.2) and (56.8±29.3) months, respectively, with no significant difference (t=−0.106, P=0.916). Radiographs showed bone healing in both groups at 3 months after operation, and no complication such as infection and traumatic arthritis occurred. At last follow-up, the posterior drawer test was negative in both groups, and the Lysholm score and IKDC score significantly improved when compared with the pre-operative values (P<0.05). However, there was no significant difference in the improvement value between the two groups (P>0.05). ConclusionFor PCL avulsion fracture at tibial insertion of the knee joint, the open reduction and absorbable screw combined with suture anchor fixation can achieve reliable fracture reduction and fixation, which is conducive to the early rehabilitation and functional exercise, and the postoperative functional recovery of the knee joint is satisfactory.

    Release date:2023-05-11 04:44 Export PDF Favorites Scan
  • The Efficacy Analysis of Treatment of Medial Avulsion Fraction and Patellofemoral Ligament Injury of Patella Following Acute Traumatic Patellar Dislocation with Anchor

    目的:探讨带线锚钉治疗急性创伤性髌骨脱位后髌骨内侧缘撕脱骨折伴内侧髌股韧带损伤的疗效。方法:自2003年9月至2008年7月共收治28例急性髌骨脱位后髌骨内侧缘撕脱骨折伴内侧髌股韧带损伤患者。对28例患者均采用开放手术下带线锚钉固定髌骨骨折及修复内侧髌股韧带损伤。术后1年进行术后的髌骨骨折Levack功能评分。结果:所有患者术后随访时间12~30个月,平均(16±3.50)个月。术后1年的髌骨骨折Levack功能评分标准优23例,可3例,差2例,优秀率达82.14%。无再次髌骨脱位或伴脱位患者。结论:开放手术下带线锚钉治疗对髌骨骨折固定及内侧髌股韧带修复可靠,是治疗急性创伤性髌骨脱位后髌骨内侧缘撕脱骨折伴内侧髌股韧带损伤的有效方法。

    Release date:2016-09-08 10:12 Export PDF Favorites Scan
  • Treatment of Wehbe-Schneider typesⅠB and ⅡB bony mallet fingers with one-stage closed reduction and elastic compression fixation with double Kirschner wires

    Objective To investigate the effectiveness of one-stage closed reduction and elastic compression fixation with double Kirschner wires for Wehbe-Schneider types ⅠB and ⅡB bony mallet fingers. Methods Between May 2017 and June 2020, 21 patients with Wehbe-Schneider type ⅠB and ⅡB bony mallet fingers were treated with one-stage closed reduction and elastic compression fixation using double Kirschner wires. There were 15 males and 6 females with an average age of 39.2 years (range, 19-62 years). The causes of injury were sports injury in 9 cases, puncture injury in 7 cases, and sprain in 5 cases. The time from injury to admission was 5-72 hours (mean, 21.0 hours). There were 2 cases of index finger injury, 8 cases of middle finger injury, 9 cases of ring finger injury, and 2 cases of little finger injury. The angle of active dorsiflexion loss of distal interphalangeal joint (DIPJ) was (40.04±4.02)°. According to the Wehbe-Schneider classification standard, there were 10 cases of typeⅠB and 11 cases of type ⅡB. The Kirschner wire was removed at 6 weeks after operation when X-ray film reexamination showed bony union of the avulsion fracture, and the functional exercise of the affected finger was started. Results The operation time was 35-55 minutes (mean, 43.9 minutes). The length of hospital stay was 2-5 days (mean, 3.4 days). No postoperative complications occurred. All patients were followed up 6-12 months (mean, 8.8 months). X-ray films reexamination showed that all avulsion fractures achieved bony union after 4-6 weeks (mean, 5.3 weeks). Kirschner wire was removed at 6 weeks after operation. After Kirschner removal, the visual analogue scale (VAS) score of pain during active flexion of the DIPJ was 1-3 (mean, 1.6); the VAS score of pain was 2-5 (mean, 3.1) when the DIPJ was passively flexed to the maximum range of motion. The angle of active dorsiflexion loss of affected finger was (2.14±2.54)°, showing significant difference when compared with preoperative angle (t=52.186, P<0.001). There was no significant difference in the active flexion angle between the affected finger (79.52±6.31)° and the corresponding healthy finger (81.90±5.36)° (t=1.319, P=0.195). At 6 months after operation, according to Crawford functional evaluation criteria, the effectiveness was rated as excellent in 11 cases, good in 9, and fair in 1, with an excellent and good rate of 95.24%. Conclusion For Wehbe-Schneider typesⅠB and ⅡB bony mallet fingers, one-stage closed reduction and elastic compression fixation with double Kirschner wires can effectively correct the deformity and has the advantages of simple surgery, no incision, and no influence on the appearance of the affected finger.

    Release date:2022-05-07 02:02 Export PDF Favorites Scan
  • Arthroscopic suspension fixation with Endobutton in treatment of tibial insertion avulsion fractures of posterior cruciate ligament

    Objective To investigate the effectiveness of arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of posterior cruciate ligament (PCL). Methods A retrospective analysis was conducted on the clinical data of 52 patients (52 knees) with tibial insertion avulsion fractures of PCL, who were treated by arthroscopic suspension fixation with Endobutton between June 2017 and October 2022. There were 29 males and 23 females, with an average age of 40.6 years (range, 19-66 years). There were 24 cases of traffic accident injuries, 17 cases of sports injuries, and 11 cases of fall injuries. The time from injury to operation ranged from 6 to 19 days (mean, 13.3 days). According to the Meyers-McKeever classification, there were 30 cases of type Ⅱ and 22 cases of type Ⅲ fractures. All patients exhibited positive posterior drawer test results. Preoperative knee joint function was assessed with Lysholm score (21.3±6.7), International Knee Documentation Committee (IKDC) score (20.7±5.8), and visual analogue scale (VAS) score (5.3±0.7); and knee joint range of motion was (41.73±3.17)°. Based on preoperative CT three-dimensional reconstruction measurements, the longitudinal diameter of the avulsed bone fragment ranged from 13 to 25 mm (mean, 18.1 mm). Operation time and occurrence of complications were recorded, and postoperative imaging was used to assess fracture healing. Knee joint function and pain severity were evaluated using knee joint range of motion, Lysholm score, IKDC score, and VAS score. Results The operation time ranged from 46 to 81 minutes (mean, 56.2 minutes). All patients were followed up 12-28 months (mean, 20.1 months). The iatrogenic fractures of bone fragments occurred during operation in 4 cases; and knee effusion occurred in 2 cases and anterior knee pain in 1 case after operation. All incisions healed by first intention. Imaging evaluations at 3 months after operation showed the fracture healing and no internal fixation failure. All patients demonstrated good knee function and had returned to normal activities at 12 months after operation. At last follow-up, the knee joint range of motion was (133.44±4.17)°, Lysholm score 93.6±3.1, IKDC score 93.4±2.5, and VAS score 1.0±0.6, with significant differences compared to preoperative scores (P<0.05). Conclusion Arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of PCL is simple to operate, and the knee joint function recovers well.

    Release date:2024-03-13 08:50 Export PDF Favorites Scan
  • BIOMECHANICAL STUDY ON SUTURE WITH NECKWEAR-KNOT-LOOPLIGATURE FOR TIBIAL EMINENCE AVULSION FRACTURES

    ObjectiveTo study the biomechanical stability of neckwear-knot-loop-ligature fixation for tibial eminence avulsion fractures by comparing with cannulated screw fixation and suture anchor fixation. MethodsTwenty-four fresh porcine knee joints were selected. After the model of tibial eminence avulsion fracture (type Ⅲ) was made, 24 samples were randomly divided into 3 groups: neckwear-knot-loop-ligature group (group A), cannulated screw group (group B), and suture anchor group (group C), 8 samples in each group. The Universal electromagnetic and mechanical testing machines were used for the biomechanical tests. After 200 cyclic tests, pull-out test was done until fixation failure. The maximum failure load, yield load, stiffness, and displacement were measured. ResultsFailure mode: the displacement was beyond limit in 8 samples of group A; screws extraction (5 samples) and bone fragment re-fracture (3 samples) were observed in group B; and suture anchor extraction (4 samples), suture rupture (3 samples), and suture thread cutting (1 sample) were found in group C. Biomechanical test: From groups A to C, the maximum failure load and yield load showed significant decreasing tendency (P<0.05), but the displacements showed significant increasing tendency (P<0.05). The stiffness also gradually decreased, but differences was not significant (P>0.05). ConclusionCompared with cannulated screw and suture anchor, neckwear-knot-loop-ligature fixation for tibial eminence avulsion fracture has good biomechanical performance and the advantages of firm fixation and simple operation.

    Release date: Export PDF Favorites Scan
  • EFFECTIVENESS OF ARTHROSCOPIC TREATMENT OF ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE WITH NON-ABSORBABLE SUTURE FIXATION COMBINED WITH MINI-PLATE

    Objective To evaluate the surgical techniques and effectiveness of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture with non-absorbable suture fixation combined with the mini-plate. Methods Between January 2009 and March 2012, 32 patients with ACL tibial eminence avulsion fractures were treated. There were 18 males and 14 females, aged 12-40 years (mean, 17.5 years). The injury causes included traffic accident injury in 15 cases, sport injury in 6 cases, and falling injury in 11 cases. The time from injury to operation ranged 7-18 days with an average of 9.5 days. Before operation, the results of Lachman test were all positive; the Lysholm score was 52.13 ± 4.22 and the International Knee Documentation Committee (IKDC) score was 44.82 ± 2.44. According to Meyers-McKeever classification criteria, there were 12 cases of type II and 20 cases of type III. After arthroscopic poking reduction of fracture, tibial eminence avulsion fractures were fixed with the Ethibond non-absorbable sutures bypass figure-of-eight tibial tunnel combined with the metacarpal and phalangeal mini-plate. Results Primary healing was obtained in all incisions; no joint infection or skin necrosis occurred after operation. All patients were followed up with an average time of 22.4 months (range, 12-50 months). The patients showed negative Lachman test at 12 weeks after operation. Except 3 patients having knee extension limitation at last follow-up, the knee extension range of motion (ROM) was normal in the other patients; the knee flexion ROM was normal in all patients. The Lysholm score and IKDC score were significantly improved to 94.19 ± 0.93 and 94.35 ± 1.22 at last follow-up, showing significant differences when compared with preoperative values (t=55.080, P=0.000; t=101.715, P=0.000). Conclusion The arthroscopic treatment of ACL tibial eminence avulsion fracture with Ethibond non-absorbable suture fixation combined with mini-plate is an effective procedure with the advantages of minimal trauma, reliable fixation, and satisfactory recovery of the knee joint function.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan
  • ARTHROSCOPIC TREATMENT OF ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE IN ADOLESCENTS WITH EPIPHYSEAL UNCLOSURE

    ObjectiveTo evaluate the clinical results of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fractures in adolescents with epiphyseal unclosure. MethodsBetween January 2011 and October 2013, 35 knees with ACL tibial eminence avulsion fractures (35 patients with epiphyseal unclosure) were arthroscopically treated with suture fixation. There were 25 males and 10 females, aged 8-16 years (mean, 14.7 years). The causes included sports injury in 24 cases, traffic accident injury in 9 cases, and daily life injury in 2 cases. According to Meyers-McKeever classification criteria, there were 27 cases of type Ⅱ and 8 cases of type Ⅲ. Five cases had meniscus injury. The preoperative the International Knee Documentation Committee (IKDC) score was 48.7±3.2, and Lysholm score was 51.2±4.5. The time from injury to operation was 2-16 days (mean, 5 days). ResultsPrimary healing of incision was obtained in all patients. The mean follow-up time was 22.4 months (range, 12-32 months). Anatomical reduction was achieved in 28 cases and satisfactory reduction in 7 cases. X-ray films showed all fractures healing at last follow-up. There was no limb shortening deformity, varus knee, or valgus knee. Lachman test results were all negative. The other knees had normal range of motion except 1 knee with limited flexion, whose range of motion returned to 0-120° after treatment. At last follow-up, the IKDC score was significantly improved to 93.2±4.1 (t=-53.442, P=0.000), and the Lysholm score was significantly increased to 96.2±2.5 (t=-56.242, P=0.000). ConclusionThe arthroscopic fixation technique has satisfactory results for the reduction and fixation of ACL tibial eminence avulsion fracture in the adolescents with epiphyseal unclosure because of little trauma and quick recovery.

    Release date: Export PDF Favorites Scan
  • ARTHROSCOPIC REDUCTION AND FIXATION OF TIBIAL INTERCONDYLAR EMINENCE AVULSION FRACTURES USING NONABSORBABLE SUTURE WITH NECKWEAR KNOT LOOP LIGATURE

    Objective To investigate the effectiveness of percutaneous reduction by leverage and fixation using nonabsorbable suture with neckwear knot loop l igature to treat tibial intercondylar eminence avulsion fractures under the arthroscope. Methods Between February 2003 and December 2008, 28 patients with tibial intercondylar eminence avulsion fractures were treated, including 16 left knees and 12 right knees. There were 15 males and 13 females with an average age of19.5 years (range, 14-45 years). The injury causes included traffic accident injury in 11 cases, sport injury in 10 cases, and sprain injury in 7 cases. Based on Meyers-McKeever classification, there were 18 cases of type III and 10 cases of type IV. The X-ray films showed the tibial intercondylar eminence displaced fracture. The mean time between trauma and operation was 7 days (range, 4-12 days). All patients were treated surgically with an arthroscopically assisted reduction by leverage and fixation using 5-0 Ethibond suture with neckwear knot loop l igature. Results All incisions healed by first intention without infection or injuries of nerves and vessels. Twenty-eight patients were followed up 26 months on average (range, 12-66 months). The X-ray films showed fracture heal ing within 9-13 weeks (mean, 11 weeks). At last follow-up, all patients were able to return to their pre-injury activity and daily l ife. The knee joint was stable with no l imp or impingement of intercondylar fossa. The knee joint range of motion was 0-130°. The results of Lachman and anterior drawer tests were negative in all patients. At last follow-up, the Lysholm score was 93.5 ± 2.5, showing significant difference when compared with the preoperative one (29.0±2.2, t=53.000, P=0.000). Conclusion Percutaneous reduction by leverage and fixation using nonabsorbable suture with neckwear knot loop l igature is minimally invasive and satisfied reduction and fixation in treating the tibial intercondylar eminence avulsion fracture under the arthroscope, so it is benefit for early functional exercises, and can achieve excellent results.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • Application of three-dimensional printing technology in treatment of internal or external ankle distal avulsed fracture

    ObjectiveTo explore the effectiveness and advantage of three-dimensional (3D) printing technology in treatment of internal or external ankle distal avulsed fracture.MethodsBetween January 2015 and January 2017, 20 patients with distal avulsed fracture of internal or external ankle were treated with the 3D guidance of shape-blocking steel plate fixation (group A), and 18 patients were treated with traditional plaster external fixation (group B). There was no significant difference in gender, age, injury cause, disease duration, fracture side, and fracture type between 2 groups (P>0.05). Recording the fracture healing rate, fracture healing time, the time of starting to ankle functional exercise, residual ankle pain, and evaluating ankle function recovery of both groups by the American Orthopaedic Foot and Ankle Society (AOFAS) score.ResultsAll patients were followed up 8-24 months, with an average of 15.5 months. In group A: all incisions healed by first intention, the time of starting to ankle functional exercise was (14±3) days, fracture healing rate was 100%, and the fracture healing time was (10.15±2.00) weeks. At 6 months, the AOFAS score was 90.35±4.65. Among them, 13 patients were excellent and 7 patients were good. All patients had no post-operative incision infection, residual ankle pain, or dysfunction during the follow-up. In group B: the time of starting to ankle functional exercise was (40±10) days, the fracture healing rate was 94.44%, and the fracture healing time was (13.83±7.49) weeks. At 6 months, the AOFAS score was 79.28±34.28. Among them, 15 patients were good, 2 patients were medium, and 1 patient was poor. During the follow-up, 3 patients (16.67%) had pain of ankle joint with different degrees. There were significant differences in the postoperative fracture healing rate, fracture healing time, the time of starting to ankle functional exercise, and postoperative AOFAS score between 2 groups (P<0.05).ConclusionApplication of 3D printing technology in treatment of internal or external ankle distal avulsed fracture is simple, safe, reliable, and effective. In particular, it is an ideal treatment for avulsed fracture.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • EFFECTIVENESS OF MINI INCISION AND ABSORBABLE SCREW FIXATION FOR TREATMENT OF ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE

    ObjectiveTo investigate the effectiveness of open reduction by mini incision and absorbable screw internal fixation for the treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture. MethodsBetween January 2006 and July 2012, 90 patients (90 knees) with ACL tibial eminence avulsion fracture were treated. There were 58 males and 32 females, aged from 10 to 58 years with an average of 33.7 years. The causes of injury were traffic accident injury in 60 cases, sports injury in 22 cases, and falling injury in 8 cases. The disease duration was 1-365 days with a median of 106 days. Combined injuries included 14 cases of meniscus injury, 5 cases of medial collateral ligament injury, and 3 cases of avulsion fracture of the anterior horn of the lateral meniscus. All patients underwent open reduction by mini incision and internal fixation with absorbable screw. Postoperative rehabilitation exercise was performed. ResultsTwo patients had delayed healing of incision, and others obtained primary healing. All the patients were followed up 6-72 months (mean, 40.1 months). X-ray examination showed that bone union was achieved in all patients at 3-12 months after operation; nail tail came off in 7 cases at 4-13 months after operation, and the nail tail was taken out under arthroscopy. At 6-12 months after operation, the range of motion (ROM), Tegner score, Lysholm score, and International Knee Documentation Committee (IKDC) score were significantly increased when compared with preoperative ones (P < 0.05). ConclusionA combination of open reduction by mini incision and absorbable screw internal fixation for the treatment of ACL tibial eminence avulsion fracture has the advantages of easy operation, firm fixation, and satisfactory functional rehabilitation, so it is a safe and effective method for the treatment of ACL tibial eminence avulsion fracture.

    Release date: Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content