Objective To evaluate the security and effectiveness of minimal invasive fixation with fluoroscopybased navigation in the management of pelvic fractures. Methods From April 2007 to June 2008, 22 patients with pelvic fractures were treated with percutaneous screw fixation under the guidance of a fluoroscopy-based navigation system after closed reduction. There were 13 males and 9 females, aged 21-65 years old. Fractures were caused by traffic accident in 17 cases, andfall ing from height in 5 cases. According to AO classification, there were 2 cases of A2.2 type, 2 cases of A2.3 type, 7 cases of B1.2 type, 3 cases of B2.2 type, 1 case of B3.3 type, 2 cases of C1.2 type, 3 cases of C1.3 type, and 2 cases of C2.3 type. The interval from injury to hospital ization was 4 hours to 3 days (mean 1.2 days). After 3-13 days of skeletal traction through tibial tubercle, the operation was performed. Results Totally 42 screws were inserted. The average time for operation was 20.4 minutes per screw. Forty-one screws were inserted correctly with a successful insertion rate of 97.6%, only 1 hollow screw was reinserted for deviation. No incision problem and implant failure occurred. All 22 patients were followed up 7 to 21 months with an average of 14.5 months. At last follow-up, fracture union was achieved in all patients with satisfactory screw fixation. According to Majeed functional scoring, the results were excellent in 18 cases and good in 4 cases, with an excellent and good rate of 100%. Conclusion The minimal invasive fixation with fluoroscopy-based navigation makes the surgery for the pelvic fracture more precise and time-saving, and improves cl inical results without an increasing rate of compl ications.
Objective To summarize the cl inical appl ication of minimally invasive percutaneous locking compression plate (LCP) internal fixation in the treatment of tibial fractures and to evaluate its cl inical effects. Methods From September 2005 to September 2007, 13 patients with tibial fractures were treated with indirect reduction and minimally invasive percutaneous LCP internal fixation, 8 males and 5 females, aged 18-35 years old (27 on average). Among them, the fractures were caused by traffic accidents in 3 cases, by fall ing in 5 cases, by fall ing from height in 4 cases and by bruise in 1 case. The fractures were located at 1/3 upper tibia in 2 cases, at 1/3 medium tibia in 6 cases and at 1/3 lower tibia in 5 cases. All fracture were closed ones. According to the AO classification, 4 cases were type A, 7 type B and 2 type C. The time between fractures and operation was from 3 hours to 5 days (2.5 days on average). Results All incisions obtained heal ing by first intention. All patients were followed up for 10-18 months (13 months on average). All fractures reached cl inical heal ing, and the heal ing time was 12-20 weeks (16 weeks on average). There was no delayed fracture heal ing, nonunion, infection and internal fixation failure. No compl ications such as rotation, crispatura deformity and internal fixation loosening were found. According to the HSS scoring, the function of the knee joint was graded 85-95 (90 on average), and the range of motion was 100-130° (120° on average). According to the AOFAS Ankie Hindfoot Scoring, the function of the ankle joint was graded 80-95 (92.4 on average). Nine cases were excellent, 4 good, and the choiceness rate was 100%. Conclusion Minimally invasive percutaneous LCP internal fixation is in accord with biological set principles and beneficial for tibial fracture heal ing and reconstruction of soft tissues.
To explore the possibil ity of treating mid-distal humeral shaft fractures associated with radial nerve palsies with minimal invasive plating osteosynthesis (MIPO) techniques. Methods From April 2003 to October 2006, 10 patients with mid-distal humeral shaft fractures associated with radial nerve palsies were treated. All patients were male, aged 19-58 years. According to AO/ASIF classification, there were 4 cases of B1 type, 2 cases of B3 type, 1 case of A2 type, 1 caseof B2 type, 1 case of C3 type and 1 case of A3 type. A straight 4.5 mm dynamic compression plate was placed on the anterior aspect of humerus through two small incisions located on the anterior side of proximal and distal part of the arm. The radial nerve exploration was performed through a lateral small incision made on the fracture site. The fractures were then reduced by manual manipulation and the plate was fixated to the main fragments with 3 screws in each end of the plate. The postoperative compl ications, the bone heal ing time, and the recovery time of the radial nerve functions were recorded. The functions of the affected shoulder and elbow were assessed with UCLA and Mayo elbow performance score system respectively. Results All incision healed by first intention. Ten patients were followed up 9-36 months with an average of 15.7 months. The X-ray films showed that the union of fractures was achieved 12-16 weeks (13.6 weeks on average). The function of the radial nerves recovered completely 12-36 weeks (17.8 weeks on average) in 9 patients. The abductions of the affected shoulder were 150-170° (165° on average). The ROM of the elbows were 130-140° (135.5° on average). According to the UCLA shoulder scoring system, 9 patients achieved the excellent result and 1 patient achieved the good result. All the patients had the excellent results according to Mayo elbow performance score system. Conclusion The mid-distal humeral shaft fractures associated with radial nervepalsies can be treated with MIPO technique and the good results can be obtained.
Objective To explore an effective micro-traumatechnic with small incision for hallux valgus. Methods From August 2002 to June 2004, 136 cases (263 feet) with hallux valgus were treated with micro-trauma technic with small incision and postoperative external elastic fixation. Of all the cases, 7 were males and 129 werefemales. Their ages ranged from 19 to 84 years. According to Coughlin classification, there were 24 gentle cases, 63 medium cases, and 49 severe cases. All the feet were with some degree of pain and flatfoot. Symptom, sign and theresults of X-ray were evaluated. Results Wound healed at stage Ⅰ.All cases were followed up for 8 to 26 months, 19 months on average. Hallux valgus of the 263 feet were completely healed, feet pain disappeared, and no nonunion or osteonecrosis was observed. Xray examination indicated that 105 feet’s hallux valgus angle was less than 12°, inter metatarsal angle less than 9°, and remedy subluxation of the tibial sesamoid less than 50%. Evaluation on the result indicated that there were 84 cases of excellent result, 48 cases of good result, 3 cases of fair result, and 1 case of poor result. The rate of excellent and good was 97%. Conclusion With less injury, less pain, complete restoration, and fewer possibility of relapse, microtrauma technic with small incision is effective in treating hallux valgus.
Objective To evalute the cl inical outcomes of two different surgical treatments for arachnoid cysts in sacral canal. Methods From January 2004 to March 2009, 55 cases of arachnoid cysts in the sacral canal were treated by traditonal simple sacral laminectomies with resection of the cysts (group A, 25 cases) and novel CT-guided percutaneous fibrin glue therapy of arachnoid cysts (group B, 30 cases). Of them, there were 23 males and 32 females, aging 15-66 years with an average of 42.6 years; the duration of symptoms was 6 months to 15 years with an average of 3.5 years. L5-S1 was involved in 22 cases, S1,2 in 25 cases, S2,3 in 12 cases, S2 in 8 cases, and presacral in 2 cases. The size of cysts was 1.5 cm × 1.0 cm to 6.0 cm × 2.8 cm. The MRI examination showed that all patients had cysts in the sacral canal. There were no significant difference (P gt; 0.05) in sex, ages, disease duration and cysts size between two groups. Preoperative data and postoperative lumbosacral pain and function improvement were analyzed and compared between two groups. Results All operations were performed successfully. The operative time, blood loss and hospital ization days of group B were significantly less than those of group A (P lt; 0.01). All 55 cases were followed up from 9 to 61 months (mean 23 months). In group A, postoperative cerebrospinal fluid leakage (25 cases), intracranial infection (2 cases), nerve injury (3 cases), and nerve root irritation (8 cases) occurred; in group B, mild meningitis (3 cases) and low grade fever (5 cases) occurred. Except for nerve injury, other compl ications were cured after symptomatic management. During the follow-up, 2 recurrent cases were found in group A and 1 case in group B. Of them, 2 recurrent cases were treated with CT-guided percutaneous fibrin glue therapy of arachnoid cysts, and cysts disappeared. For two groups, there were significant differences in Oswestry functional disabil ity index and visual analogue scale score between preoperation and postoperation (P lt; 0.01), and in the rate of score improvement between two groups (P lt; 0.01). According to the rating scale, the excellent and good rates of pain improvement were 64% in group A and 100% in group B; the excellent and good rates of function improvement were 24% in group A and 97% in group B. Conclusion CT-guided percutaneous fibrin glue therapy for arachnoid cysts in the sacral canal is a mini-invasive, safe, effective, and economical method, it may be better choices for the treatment of arachnoid cysts in the sacral canal.
Objective To review the progress in the features, early cl inical outcomes, and cl inical appl ication of axial lumbar interbody fusion (AxiaLIF) for the minimally invasive treatment of lumbosacral degenerative diseases. Methods The l iterature about the features, early cl inical outcomes, and cl inical appl ication of AxiaLIF for the minimally invasive treatment of lumbosacral degenerative diseases in recent years was reviewed. Results Almost 9 000 procedures performed globally in recent years, AxiaLIF has shown its safety and effectiveness because of high fusion rates, short hospital ization days, and less iatrogenic compl ications in comparison with standard fusion procedures. ConclusionPostoperative long-term outcomes, biomechanics stabil ity, and extended appl ication of AxiaLIF still need a further study,though it suggests an original minimally invasive treatment of lumbosacral degenerative diseases.
Objective To assess the effectiveness of a novel minimally invasive Achilles tendon suture instrument in the treatment of fresh closed Achilles tendon rupture. Methods A retrospective study was conducted on 150 patients who underwent surgical intervention for fresh closed Achilles tendon rupture. Eighty patients were treated with the novel minimally invasive Achilles tendon suture instrument (minimally invasive group) and 70 patients with traditional open surgery (traditional group). The two groups were comparable in terms of gender, age, injured side, cause of injury, the interval between injury and operation, and the distance from the fracture end to the calcaneal tuberosity (P>0.05). The operation time, intraoperative blood loss, incision length, hospital stays, hospitalization expenses, and complications were recorded and compared. At 1 year after operation, the ankle joint function was evaluated by the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score. Results The minimally invasive group demonstrated significantly shorter operation time, smaller incision length, and lower intraoperative blood loss when compared with the traditional group (P<0.05). However, there was no significant difference in terms of hospital stays and hospitalization expenses between the two groups (P>0.05). All patients were followed up 12-24 months after operation (mean, 15.5 months). In the traditional group, 6 cases of incision necrosis and 7 cases of Achilles tendon adhesion occurred, while in the minimally invasive group, all incisions healed at first intention and no Achilles tendon adhesion occurred. The differences in the incidences of the two complications between the two groups were significant (P<0.05). At 1 year after operation, the AOFAS ankle-hindfoot score in the minimally invasive group was superior to that of the traditional group (P<0.05). Conclusion In comparison with traditional open surgery, the use of self-designed novel minimally invasive Achilles tendon suture instrument proves to be an ideal technique for treating fresh closed Achilles tendon ruptures. This approach offers the benefits of smaller incisions, fewer complications, and better postoperative functional recovery, without increasing hospital costs.
ObjectiveTo review and evaluate the technical advantages and disadvantages and research progress of percutaneous endoscopic lumbar interbody fusion. MethodsThe domestic and foreign related research literature on percutaneous endoscopic lumbar interbody fusion was extensively consulted. The advantages, disadvantages, and effectiveness were summarized. And the development trend of this technology was prospected. ResultsCompared with minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF), percutaneous endoscopic lumbar interbody fusion has less intraoperative and postoperative bleeding, better improvement of low back pain in the early stage after operation, and similar long-term effectiveness, fusion rate, and incidence of complication, but a longer learning curve. The operation time of biportal and large-channel uniportal endoscopic lumbar fusion is close to that of MIS-TLIF, but the operation time of small-channel uniportal endoscopic fusion is longer than that of MIS-TLIF. ConclusionPercutaneous endoscopic lumbar interbody fusion has the advantages of less trauma and good effectiveness, but its learning curve is long, and indications should be strictly selected for this operation. In the future, with the continuous development and complementation of various endoscopic fusion technologies, this technology will gain better application prospects.