west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "彩色多普勒超声" 53 results
  • Study on Evaluation of Hemodynamic Changes of Portal Veins in Patients with Liver Cirrhosis by Color Doppler

    目的 分析彩色多普勒超声对肝硬化患者门静脉血流改变的评价作用。 方法 选择2010年1月-2011年4月收治的50例肝硬化患者作为观察组,其中代偿期患者27例,失代偿期患者23例;同时设置健康对照组50名,比较两组的门静脉内径(Dpv)、门静脉平均血流速度(Vpv)、门静脉血流量(Qpv)。 结果 观察组患者的Dpv增宽,Vpv减慢,Qpv减少,与对照组比较,差异均有统计学意义(P<0.05);且失代偿期患者的改变更为明显,与代偿期患者间差异有统计学意义(P<0.05)。 结论 彩色多普勒超声检查门静脉血流改变可以对肝硬化患者进行初步确诊。

    Release date:2016-09-08 09:13 Export PDF Favorites Scan
  • Value of Color Doppler Ultrasonography and Plasma D-imer in Diagnosis of Lower Limb Venous Thrombosis

    Objective To explore the value of color Doppler ultrasonography and plasma D-dimer in diagnosis of lower limb deep venous thrombosis (DVT).Methods The clinical data of 70 cases of patients with lower limb DVT diagnosed clinically were retrospectively studied. The lower limb venous of each patient was examined by color Doppler ultrasonography and the plasma level of D-dimer were measured, furthermore the plasma levels of D-dimer in different phase and different type of thrombosis were compared. Results The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of plasma D-dimer and ultrasonography examination in lower limb DVT were 100%, 66.7%, 97.0%, 100%, and 97.1%, and 98.4%, 83.3%, 98.4%, 83.3%, and 97.1%, respectively. The plasma D-dimer in acute phase 〔(6 451±4 012.22) μg/L〕 and subacute phase 〔(2 063±1831.35) μg/L〕 of lower limb venous thrombosis were significantly higher than that in normal control group 〔(310±66.70) μg/L〕, Plt;0.01 and Plt;0.05, which was not different from that in chronic phase 〔(466±350.52) μg/L〕. Meanwhile, the plasma D-dimer in mixed limb venous thrombosis group 〔(4 464±3 753.16) μg/L〕 and central limb venous thrombosis group 〔(2 149±1 911.53) μg/L〕 were significantly higher than that in control group (Plt;0.05 and Plt;0.01), which was not different from that in peripheral limb venous thrombosis group 〔(560±315.62) μg/L〕. Conclusion Color Doppler ultrasonography is an optimal method and the plasma D-dimer is a predictive index in diagnosis of lower limb DVT.

    Release date:2016-09-08 10:54 Export PDF Favorites Scan
  • 经阴道腔内彩色多普勒超声诊断子宫切口瘢痕妊娠的价值评估

    【摘要】 目的 评估经阴道彩色多普勒超声对子宫切口瘢痕妊娠的诊断价值。 方法 对2004年9月-2011年2月经阴道彩色多普勒超声检查后并通过临床及病理确诊为子宫切口瘢痕妊娠的20例患者进行回顾性分析。 结果 20例患者中阴道彩色多普勒超声正确诊断17例(85.0%),误诊3例(15.0%)。 结论 阴道彩色多普勒超声检查对子宫切口部瘢痕妊娠的诊断有重要的价值,对临床选择正确的治疗方案有指导意义。

    Release date:2016-09-08 09:26 Export PDF Favorites Scan
  • 高尿酸血症与颈总动脉血管损害相关性的彩色多普勒超声研究

    目的 应用二维超声及 M 型超声探讨高尿酸血症与颈总动脉血管损害的相关性。 方法 选择 2011 年 1 月—2015 年 12 月无高血压、高血糖、高血脂及吸烟史患者 121 例,其中高尿酸血症患者 59 例,观察颈总动脉 118 根(高尿酸血症组);无高尿酸血症患者 62 例,观察颈总动脉 124 根(正常组)。应用二维超声分别观察颈总动脉斑块数量、测量两组患者颈总动脉内中膜厚度,应用二维引导的M型超声测量颈总动脉前壁搏动幅度(搏幅)和前壁搏幅达峰时间、前壁搏幅斜率。 结果 高尿酸血症组观察颈总动脉 118 根,共发现颈总动脉粥样斑块 83 个(70.3%);正常组观察颈总动脉 124 根,共发现颈总动脉粥样斑块 31 个(25.0%);两组粥样斑块数与颈总动脉总数之比差异有统计学意义(P<0.05)。高尿酸血症组与正常组颈总动脉内中膜厚度分别为(0.93±0.17)、(0.56±0.30)mm,前壁搏幅分别为(0.43±0.19)、(0.73±0.27)mm,前壁搏幅达峰时间分别为(64.5±13.3)、(64.5±14.8)ms,前壁搏幅斜率分别为(1.21±0.33)、(1.36±0.19)mm/s,两组颈总动脉内中膜厚度、血管前壁搏幅及血管前壁搏幅斜率差异有统计学意义(P<0.05),血管前壁搏幅达峰时间差异无统计学意义(P>0.05)。 结论 高尿酸血症与颈总动脉血管内皮损害及动脉粥样硬化有直接的相关性。

    Release date:2017-05-18 01:09 Export PDF Favorites Scan
  • 高频彩色多普勒超声诊断肌疝一例

    Release date:2016-09-08 09:16 Export PDF Favorites Scan
  • APPLICATION OF HIGH FREQUENCY COLOR DOPPLER ULTRASOUND IN ANTEROLATERAL THIGH FLAP SURGERY

    Objective To investigate the effectiveness of high frequency color Doppler ultrasound for detecting perforators in the anterolateral thigh (ALT) flap surgery. Methods Between February 2011 and July 2012, 8 patients underwent high frequency color Doppler ultrasound to detect the perforator anatomy before ALT flap surgery. There were 5 males and 3 females, aged 21-46 years (mean, 34 years). Defects were caused by excision of squamous cell carcinoma in 2 cases, by scalp avulsion in 2 cases, by soft tissue necrosis after neck trauma in 1 case, by excision of groin fibrosarcoma in 1 case, by excision of groin melanoma in 1 case, and by malformation of the face in 1 case. The defect size varied from 12 cm × 7 cm to 22 cm × 18 cm. The perforator with wider caliber, faster flow speed, and shorter intramuscular trajectory was selected, and the flap was designed according to the observed results, which size varied from 14 cm × 9 cm to 25 cm × 20 cm. The donnor sites were repaired by free skin graft. Results Totally, 19 perforators in the flap area were detected by high frequency color Doppler ultrasound, and 18 were identified during operation, with an accuracy rate of 94.7%. The point going out muscle, the travel and direction of perforators observed during operation were basically in accordance with those detected by high frequency color Doppler ultrasound. The other flaps survived, and obtained healing by first intention except 1 flap which had partial fat necrosis with healing by second intention. The skin graft at donor site survived. All patients followed up 4-16 months (mean, 8 months). The flaps had good color and texture. Conclusion High frequency color Doppler ultrasound is a valuable imaging modality for the preoperative assessment of the vascular supply for ALT flap.

    Release date:2016-08-31 04:06 Export PDF Favorites Scan
  • 微小肝癌诊治体会(附1例报告)

    Release date:2016-08-29 03:18 Export PDF Favorites Scan
  • 股动脉穿刺后假性动脉瘤的超声诊断与治疗

    目的评价彩色多普勒超声在股动脉穿刺后股动脉假性动脉瘤形成的诊断及治疗中的临床应用价值。 方法回顾性分析2011年1月-2013年11月10例股动脉穿刺后假性动脉瘤形成的彩色多普勒超声声像图表现,总结在超声引导下对假性动脉瘤进行压迫治疗的操作方法,并对治疗结果追踪复查。 结果10例患者超声均查见股动脉周围无回声团块或混合回声团,并在瘤体内查见涡流血流信号及破口处出现“双期双向”血流频谱。10例假性动脉瘤患者行超声引导下压迫治疗,7例1次按压成功,3例重复多次按压成功。 结论彩色多普勒超声诊断假性动脉瘤准确率高,是首选的检查方法。超声引导下压迫治疗股动脉穿刺后假性动脉瘤,是一种有效的治疗方法,可以作为首选。

    Release date: Export PDF Favorites Scan
  • Ultrasound imaging manifestations of idiopathic uveal effusion syndrome

    Objective To observe the ultrasonographic features of idiopathic uveal effusion syndrome (IUES). MethodsA retrospective controlled study. From January 2012 to December 2023, 13 patients with IUES (26 eyes) diagnosed by ophthalmology examination in Department of Ophthalmonogy of Beijing Tongren Hospital (IUES group) and 22 healthy people with 30 eyes (control group) were included in the study. Both eyes of all participants were examined by color Doppler ultrasound (CDU) and ultrasonic biomicroscopy (UBM). The thickness of the ocular wall at 300 μm on the temporal side of the optic disc was measured by CDU. UBM was used to measure the thickness of the nasal and temporal scleral processes. Corneal thickness (CT), anterior chamber depth (AD), lens thickness (LT) and axial length (AL) were measured by A-mode ultrasound. There were no significant differences in age (t=0.842), sex component ratio (χ2=0.540), eye difference (χ2=0.108) and AL (t=0.831) between IUES group and control group (P>0.05). The CDU and UBM imaging features and biometrics of IUES affected eyes were observed. Independent sample t test was used for comparison between groups. ResultsCDU examination results showed that in 26 eyes of IUES group, choroidal detachment occurred in 20 eyes (76.9%, 20/26), which showed arc-shaped band echo connected with peripheral and equatorial eye wall echo, with uniform low echo area below, and blood flow signal could be seen on the band echo. The echo thickened and decreased in 4 eyes (15.3%, 4/26). Nine eyes (33.3%, 9/26) were accompanied by retinal detachment, which showed that the posterior pole vitreous echo was connected to the optic disc echo, and the blood flow signal was seen on the ribbon echo. UBM results showed ciliary detachment in 22 eyes (84.7%, 22/26), showing a spongy thickening of the ciliary body with interlamellar echo separation and an echoless area between the sclera. Ciliary body echo thickened and decreased in 2 eyes (7.7%, 2/26). Shallow space between ciliary body and sclera was observed in 2 eyes (7.7%, 2/26). Compared with the control group, CT (Z=2.054), LT (Z=1.867), scleral thickness (Z=2.536) and ocular wall thickness (Z=2.094) were thickened in IUES group, and AD (Z=1.888) were decreased, with statistical significance (P<0.05). ConclusionsThe CDU of IUES is characterized by a thickened echo of the ocular wall and a uniform low echo area under the detached choroid. UBM is characterized by a spongy thickening of the ciliary body echo with interlaminar echo separation.

    Release date:2025-05-14 02:04 Export PDF Favorites Scan
  • 彩色多普勒超声诊断露脑畸形伴羊膜带综合征一例

    Release date: Export PDF Favorites Scan
6 pages Previous 1 2 3 ... 6 Next

Format

Content