ObjectiveTo introduce implantation methods of different types of congenital heart disease occluder for the treatment of bronchopleural fistula (BPF) and its preliminary efficacy.MethodsThree patients who diagnosed with BPF and treated by congenital heart disease occluder were reviewed. The clinical data was analyzed after comprehensively reviewing of relevant literature.ResultsAll the three patients were treated with postoperative BPF and empyema. The diameter of the fistula ranged from 3 to 8 mm. We used occlusive devices for congenital heart diseases such as atrial septum (ASD), ventricular septum (VSD) defect or patent ductus arteriosus (PDA), respectively. After treatment, all three patients were cured of BPF and empyema caused by BPF in a short time, and the thoracic drainage tube was successfully removed. During the follow-up period from 7 to 25 months, no significant long-term complications were observed.ConclusionThe use of ASD, VSD and PDA occluder for the treatment of BPF with a fistula more than 3 mm is effective and safe.
Objective To access the feasibility, effectiveness and safety of transcatheter closure of ventricular septal defects(VSD) in 17patients. Methods Seventeen patients, aged 4 23 years, were selected by transthoracic echocardiography. The location of VSD was perimembranous in 16 patients and was muscular in 1 patient. And 1 patient with aneurysm formation. All cases had no severe pulmonary hypertension or right to left shunt. Membranous VSD underwent transcatheter closure with Amplatzer membranous VSD occluder or membranous VSD occluder made in China. Muscular VSD was closed by Amplatzer patent ductus arteriosus occluder. Results The VSD diameter ranged from 2.3 10.5 mm(5.75±2.10 mm). The device diameter ranged from 412 mm (7.12±1.67 mm). After application of the prosthesis there was no residual shunt in all patients. One patient developed grade I atrioventricular block and complete right bundle branch block. Two patients developed right bundle branch block after 3 4 days. No other compli...更多cations were observed in 1 12 months follow up. Conclusion The transcatheter closure of VSD appears to be a safe and effective method.
Atrial septal defect (ASD) is a congenital heart disease that causes blood communication between the left and right ventricles due to partial atrial septal tissue defects, accounting for about 13% of all heart malformations. Secondary ASD is the most common type of ASD and can generally be treated with minimally invasive closure. At present, the commonly used minimally invasive methods in clinical practice mainly include X-ray-guided percutaneous occlusion, transesophageal ultrasound-guided transthoracic occlusion and ultrasound-guided percutaneous occlusion. This review focuses on the basic research process of occluder materials, and advantages and disadvantages of three different surgical methods.
ObjectiveTo evaluate the efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with transthoracic echocardiography (TTE).MethodsFrom February 2016 to November 2018, 98 patients of pure PDA were selected, including 43 patients of funnel type and 55 patients of tube type. There were 38 males and 60 females at age of 2-48 (9.8±10.4) years. All patients underwent TTE-guided retrograde closure of the PDA through the femoral artery to establish a femoral-abdominal aorta-thoracic aorta-ductus arteriosus-aorta-right ventricle trajectory.Under the guidance of TTE, a suitable closure umbrella was placed through the femoral artery. One month, 3 months, 6 months, 12 months after the surgery, the patients received out-patient clinical follow-up.ResultsNinety eight patients were successfully occluded by TTE. The occluder was replaced many times in an adult PDA patient, but finally it was successfully plugged. The operation time was 33.2±5.8 min. The lumbar diameter was 12±6 mm. And the postoperative murmur disappeared. Ultrasound showed no shunt between the aorta and the pulmonary artery, and the postoperative hospital stay was 3-4 days. No shunt signal was found in 1, 3, 6, 12 months follow-up. Left atrial anteroposterior diameter (25.8±6.1 mm vs. 30.6±8.4 mm) and left ventricular end diastolic diameter (38.5±9.1 mm vs. 45.2±11.5 mm) were significantly smaller (P < 0.05).ConclusionTTE-guided transcatheter closure of PDA via femoral artery is a safe and effective method to avoid the damage of X-ray and contrast medium. The prospect of clinical application is good.
Objective To explore the safety and efficacy for patients with central airway-pleural fistula (APF) treated by atrial septal defect (ASD) occluder. Methods This was a retrospective study. Between January 2017 and October 2021, a total of 16 patients with postoperative APF were treated with ASD occluder through bronchoscope under local anesthesia combined with sedation. The efficacy and complication were recorded during and after the procedure. Results Sixteen patients were recruited in this study and the average age was 60.7 years (range 31 - 74 years). The main etiology for APF was lobectomy/segmentectomy (n=12), pneumonectomy (n=2), radical esophagectomy (n=1) or decortication for chronic empyema (n=1). Totally, 4 fistulas were located in right main bronchus, 3 in left main bronchus, 3 in right upper bronchus, 1 in right middle bronchus, 2 in right lower bronchus and 3 in left upper bronchus. The median diameter of APF was 7.8 mm (ranged from 4 to 18 mm) and the median diameter of ASD occluder inserted was 10.0 mm (ranged from 6 to 20 mm). Successful occlusion of APF was observed in 15 patients (15/16) and 1 patient died of multiple organ failure caused by bacteremia 14 days after the procedure. Fourteen patients were recruited for long-term follow-up, on a median follow-up period of 16.2 months (ranged from 3 to 46 months). There were 12 patients of complete remission and 2 patients of partial remission and only one patient took a second operation due to the enlargement of fistula and translocation of occluder. At follow-up, 4 patients died and the reasons were directly related to the primary etiology, and no patient died due to APF recurrence. Conclusion Endobronchial closure of central APF using ASD occluder is a minimally invasive but effective modality of treatment with satisfactory long-term outcome.
Objective To introduce the application of transcatheter closure of multi-fenestrated atrial septal defect (ASD) via femoral vein under ultrasound guidance with amplatzer cribriform occluder (ACO) and atrial septal defect occluder (ASDO), as well as to assess its feasibility, effectiveness and safety. Methods The clinical data of 48 patients with fenestrated ASD occluded via femoral vein under ultrasound guidance from December 2015 to May 2018 in our hospital were retrospectively analyzed, including 17 males and 31 females, aged 10 months to 51 years, an average of 11.50±13.86 years, and weighting 6-79 (27.00±20.14) kg. Among 48 patients with fenestrated ASD, 12 patients had double-foramen and 13 atrial septal aneurysm combined with defects and 23 multi-foramen. All patients underwent transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE) to complete the closure of fenestrated ASD. Ultrasound, electrocardiogram and chest X-ray were reviewed the next day after surgery to evaluate the curative effect. Results Forty-eight patients with ASD were treated with 49 occluders, due to one patient with two occluders. There were 29 ASDO (8-26 mm) and 20 ACO (18-34 mm). During the operation, TTE/TEE examination showed that 48 patients were completely occluded, 13 patients showed fine bundle shunt in the unreleased push notification rod, and 9 patients had fine bundle shunt after the release of push notification rod. Fine bundle shunt was found in 8 patients 24 hours after operation, and microshunt was found in 3 patients 1 year after operation. All the patients were followed up. The occluder position was good. The right heart was reduced in different degrees, and the X-ray showed that the pulmonary blood was reduced in different degrees. No arrhythmia was found by electrocardiogram after operation. Conclusion It is a safe and effective method to use ACO and ASDO to occlude ASD through femoral approach under ultrasound guidance.
Currently, transcatheter intervention is the preferred treatment for patients with anatomically suitable atrial septal defects. However, the use of nickel-titanium alloy occluders in interventional procedures results in lifelong presence of the implant in the body, leading to complications such as metal allergies and arrhythmias in some patients. To overcome the short-term and long-term complications associated with the presence of metal, and to avoid radiation exposure and metal toxicity, this paper reports a case of successful transcatheter closure of atrial septal defect in a pediatric patient with metal allergies using fully biodegradable occluder under ultrasound guidance, achieving excellent results by interventional therapy.
Transcatheter intervention for congenital heart disease has been developed for 40 years in China, it has experienced the transition of learning to self-dependent innovation, and witnessed the intervention therapy system starting from scratch and gradually reaching the top level and gaining high achievements in the world scale. With the continuous development of interventional technology and devices, cutting-edge ideas and viewpoints are constantly discussed. This review summarized the development of intervention techniques and devices, hoping to provide some experience for the further development of transcatheter interventions for congenial heart disease.
ObjectiveTo investigate clinical outcomes and safety of transesophageal echocardiography (TEE)-guided occlusion of infundibular ventricular septal defect (VSD) via minithoracotomy. MethodsClinical data of 21 pediatric patients with infundibular VSD who underwent TEE-guided occlusion via minithoracotomy in Children's Hospital of Hebei Province from January to June 2013 were retrospectively analyzed. There were 10 male and 11 female patients with their age of 8-24 (16±8) months and body weight of 9±3 kg. The size of VSD was 4.5±2.5 mm. TEE was used to evaluate the position of the occluder, its influence on the atrioventricular valves and aortic valve, and the presence of residual shunt. ResultsThere was no perioperative death or complication. VSD occlusion was successfully performed in 20 out of 21 patients (95.2%). One patient received conversion to open VSD repair under extracorporeal circulation because VSD size was too big. Mean time of delivery of occluders was 32±16 minutes, the size of the occluders was 5±3 mm, and length of hospital stay was 6-8 days. All the patients were followed up for 3-6 months after discharge. During follow-up, echocardiography showed clear echo and normal position of the occluders, and there was no mild or more severe residual shunt or valvular regurgitation. ConclusionTEE-guided occlusion of infundibular VSD via minithoracotomy is easy to perform and safe with satisfactory clinical outcomes.