west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "对比剂" 12 results
  • Evaluation of Cirrhosis-Associated Hepatocellular Nodules by MR Imaging

    Release date:2016-09-08 11:05 Export PDF Favorites Scan
  • Magneticaly Labeled Stem Cells and Magnetic Resonance Imaging Tracking in Vivo

    Magneticaly labeled stem cells and magnetic resonance imaging(MRI) technology is an effective tracking method in vivo study, which has high spatial-temporal resolution. Gadolinium, which shows positive T1 signals and iron oxide showing negative T2 signals are the two often used contrast agents. The latter also include superparamagnetic iron oxide particle and ultrasmall superparamagnetic iron oxide particle. Transfection agents, e.g. poly-L-lysine and protamine sulfate,can enhance magnetical nanoparticles labeling stem cells. The biological characteristics of labeled stem cells did not seem to be altered. MRI can detect the labeled stem cells’ signals and also can track changes of signal in intensity and size with time past. In conclusion, MRI tracking magneticaly labeled stem cells represents a method for noninvasivly monitoring the existence and migration of engrafts.

    Release date:2016-08-30 06:04 Export PDF Favorites Scan
  • Value of Superparamagnetic Iron Oxide in the Experimental Autoimmnune Encephalomyelitis Model

    【摘要】 目的 在实验性自身免疫性脑脊髓炎(experimental autoimmune encephalomyelitis,EAE)模型中,比较常规T2加权成像(T2weighted imaging,T2WI)、钆二乙三胺五醋酸(gadoliniumdiethylenetriamine pentaacetic acid,GdDTPA)和超顺磁性氧化铁(superparamagnetic iron oxide,SPIO)增强图像之间的差异,探讨巨噬细胞在多发性硬化(multiple sclerosis,MS)炎性活动病灶中的细胞学标志。方法 在EAE模型临床症状的亚临床期、初发期、高峰期,13只复发缓解(relapsingremitting,RR)EAE大鼠模型组和13只正常对照组大鼠在注入对比剂之前均行常规T2WI扫描,接着分别在其尾静脉注入GdDTPA后5 min行T1加权成像(T1weighted imaging,T1WI),再注入SPIO,24 h后行T2WI扫描。扫描完毕后立即处死大鼠取脑,行脑组织切片的ED1免疫组织化学染色和Prussian blue染色。结果 EAE模型组大鼠在第11天出现临床症状(初发期),第14天达到高峰期;MRI检查:SPIO增强图像对EAE病灶的显示较常规T2WI和GdDTPA增强图像好。病理学检查:ED1染色,在SPIO显示为低信号的区域内出现了炎症细胞(以巨噬细胞为主)浸润;Prussian blue染色示病灶内巨噬细胞胞质内出现了蓝染颗粒,沉积部位与T2WI上低信号区对应。对照组大鼠均无异常。结论 SPIO较GdDTPA更好地显示EAE模型中炎性活动性病灶内血管周围以巨噬细胞为主的浸润。

    Release date:2016-09-08 09:37 Export PDF Favorites Scan
  • 碘对比剂渗漏患者原因分析及护理对策

    目的探讨患者行CT增强扫描后出现碘对比剂渗漏的原因及护理对策。 方法对2014年1月-5月45例行CT增强扫描检查后出现碘对比剂渗漏患者的临床资料进行回顾性分析。 结果1例碘对比剂渗漏患者出现继发性水疱,经采用冰盐水冷敷3 d后,其表皮小水疱自行吸收,未出现继发性感染、组织坏死等现象;其余44例患者经常规对症护理后,无不良后果。全体碘对比剂渗漏患者均完成增强CT 扫描检查,且图像合格。 结论对CT增强扫描的患者提前采取针对性的预防措施,可降低碘渗漏的发生率;对已发生碘渗漏的患者进行正确、有效的护理处置及后续随访指导,可减少患者的痛苦和组织损伤,并避免或降低潜在的医疗纠纷及投诉。

    Release date: Export PDF Favorites Scan
  • Efficacy of different pharmacological interventions in the prevention of contrast-induced acute kidney injury after percutaneous coronary intervention: an overview of systematic reviews

    ObjectiveTo analyze systematic reviews (SRs) and meta-analyses on the efficacy of pharmacological interventions in the prevention of contrast-induced acute kidney injury (CI-AKI) after percutaneous coronary intervention (PCI). MethodsWe searched the PubMed, The Cochrane Library, EMbase, CNKI, CBM, WanFang Data, and VIP databases to identify SRs and meta-analyses on the pharmacological interventions aimed at preventing CI-AKI after PCI from inception of the databases to February 2022. Two researchers independently screened the literature and extracted data. The PRISMA statement, AMSTAR 2 tool, and GRADE system were adopted to evaluate the reporting quality, methodological quality, and evidence quality of the findings of the included SRs and meta-analyses. ResultsA total of 14 SRs and meta-analyses were identified. Among the drugs used were statins, N-acetylcysteine, sodium bicarbonate, Dan-hong injection, vitamins, salvianolate, adenosine antagonists, nicorandil, allopurinol, alprostadil, furosemide, trimetazidine, probucol, and brain natriuretic peptide. Most of the studies had relatively comprehensive coverage of the items, with the PRISMA scores ranging from 18 to 24.5. The main issues of reporting quality were protocol and registration, search, and funding. The methodological quality of the SRs and meta-analyses was generally low. Items 2 and 7 were the key items with poor scores, and the non-critical items with poor scores were items 3, 10, and 16. All drugs, except furosemide, decreased the incidence of CI-AKI. The quality of evidence ranged from medium to very low according to GRADE. Conclusion Most of the single drugs or drugs combined with hydration show the potential to prevent CI-AKI, however, the overall methodological quality of the included studies is relatively low, and the strength of evidence is generally low.

    Release date:2022-05-31 01:32 Export PDF Favorites Scan
  • Nursing of Coronary Angiography by 64 Slice Spiral CT

    目的:探讨64层螺旋CT冠状动脉成像(64-slice CTA)检查中护理工作的重要性及获得最佳图像的影响因素。材料与方法:对462例行64-slice CTA检查的患者进行有效的护理措施和细致的前期准备工作。结果:462例检查者中96%的病例达到诊断标准。结论:经过细致准备和护理,可以提高图像质量和冠脉疾病的诊断率。

    Release date:2016-09-08 10:00 Export PDF Favorites Scan
  • The Influence of Different Concentrations of Iodinated Contrast Agent on Image Quality of Galactography

    ObjectiveTo explore the influence of different concentrations of iodinated contrast agent on image quality of galactography. MethodsBetween June 2008 and October 2009, 50 non-pregnancy and non-lactation patients with mammary papilla discharge underwent breast galactography with digital mammography. All the patients' left breasts were in group L, and right breasts were in group R. The iohexol concentration of iopamidol injection was 370 mg/mL in group L and 300 mg/mL in group R. The image quality and the evaluation of average density of the two groups was analyzed and compared. ResultsThe image quality score of group L and R was 2.8±0.2 (P>0.05). The mean density of main duct of breast axial view in two groups was (4 020.25±96.26) and (3 984.75±117.67) HU, respectively; the mean density of the lateral oblique view was (4 067.13±24.69) and (3 971.25±167.32) HU, respectively; the mean density of the lateral view was (4 058.88±52.07) and (4 034.75±67.54) HU, respectively. There was no significant difference between the two groups (P>0.05). ConclusionNo obvious difference between the two concentrations of non-ionic iodinated contrast agents (300 and 370 mg/mL) in galactography diagnosis is found.

    Release date: Export PDF Favorites Scan
  • Feasibility Study of Gemstone CT Coronary Angiography with Low Tube Voltage and Low Concentration Contrast Medium

    ObjectiveTo assess the image quality and radiation dose of gemstone CT coronary angiography (CCTA) with low tube voltage and low concentration contrast medium. MethodsSixty-nine patients who underwent CCTA from January to March 2014 were randomly divided into group A and B. CCTA was performed in thirty-four patients in group A with tube voltage of 100 kV and concentration of contrast medium of 300 mgI/mL. And thirty-five patients in group B underwent CCTA with 120 kV and 370 mgI/mL. According to upgrading American Heart Association standard all segments and all vessels were evaluated. We measured the CT value of ascending aortic root, left main coronary artery, and the initial segment of left anterior descending branch, left circumflex, right coronary artery, and also adjacent tissues. Besides, we recorded CT dose volume index (CTDIvol) and the dose length product (DLP) and calculated effective radiation dose. ResultsThe image quality scores were not significantly different between two groups (P>0.05). The density in the contrast enhanced vessel lumens in group A were signifcantly higher than that in group B (P<0.05). There was no significant difference in signal to noise ratio and carrier to noise ratio between the two groups (P>0.05). Noise in group A was higher than that in group B (P<0.05). The CTDIvol and effective radiation dose in group A were significantly lower than those in group B (P<0.05). ConclusionThe combination of 100 kV with low concentration contrast medium (300 mgI/mL) still maintains the image quality, as well as significantly lowers the radiation dose and the dose of iodine.

    Release date: Export PDF Favorites Scan
  • Application of low-dose contrast agent combined with physiological saline in SOMATOM Definition Flash CT angiography for head and neck

    ObjectiveTo explore the clinical value of low-dose contrast agnet in CT angiography (CTA) for head and neck by SOMATOM Definition Flash CT.MethodsSixty consecutive patients with head and neck vessel diseases examined by CTA in the head and neck were chosen from West China Hospital of Sichuan University from March to July 2015, and then were randomly divided into two groups (the experimental group: n=30, 30 mL contrast medium; the control group: n=30, 50 mL contrast medium). Imaging post processing techniques included curved plannar reconstruction, volume rendering, and maximal intensity projection. CT values of the different level of carotid arteries (aortic arch, carotid bifuracation, and M1 segment of middle cerebral artery) were measured. The artifact of the remaining contract in the jugular vein and overall quality of the image were observed by two senior doctors using double blind method.ResultsAll the patients in the two groups completed CTA for head and neck successfully. The image qualities of the two groups satisfid clinical diagnostic requirements, and there was no difference in the image qualities between the two groups (P>0.05). The evaluation of venous pollution in the experimental group was lighter than that in the control group (P<0.05). The CT values of aortic arch, carotid bifuracation, and M1 segment of middle cerebral artery in the experimental group [(341.3±89.5), (391.0±103.7), (305.0±62.0) HU] were slightly lower than those in the control group [(437.3±83.7), (532.5±113.3), (396.6±93.1) HU], which were statistically significant (P<0.05).ConclusionLow-dose contrast in CTA for head and neck by SOMATOM Definition Flash CT can satisfy the clinical diagnostic requirements, and reduce the dose of contrast agent and venous pollution, with a good clinical value.

    Release date:2018-08-20 02:24 Export PDF Favorites Scan
  • Association of homocysteine and contrast-induced nephropathy: a meta-analysis

    ObjectivesTo evaluate the association between high homocysteine (Hcy) levels and risk of contrast-induced nephropathy (CIN).MethodsCNKI, VIP, WanFang Data, PubMed, The Cochrane Library and Web of Science databases were electronically searched to collect the case-control studies on the association between Hcy and risk of CIN from inception to November 30th, 2017. Two reviewers independently screened literature, extracted data and assessed the risk of bias of included studies. Meta-analysis was performed by using Stata 12.0 software.ResultsTen case-control studies involving 6 124 subjects were included. Meta-analysis showed that the high Hcy level was associated with an increased risk of CIN (OR=1.59, 95%CI 1.33 to 1.89, P<0.001), and the homocysteine level in CIN group was higher than that in non-CIN group (WMD=8.74, 95%CI 6.18 to 11.31,P<0.001).ConclusionsAccording to the current evidence, the high Hcy level is a risk factor for CIN. Due to limited quality and quantity of the included studies, more high quality studies are required to verify the above conclusion.

    Release date:2018-07-18 02:49 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content