To investigate an effect of tranexamic acid on blood loss associated with total knee arthroplasty (TKA).Methods From June 2005 to June 2006, 102 patients (43 males, 59 females; aged 59-77 years, averaged 68 years) underwent TKA. Of the 102 patients, 59 had osteoarthritis, 23 had rheumatoid arthritis, and 20 had traumatic arthritis.The illness course ranged from 2 to 12 years. They were randomized divided into Group A and Group B of 51 patients each. The patients in Group A received tranexamic acid, and the patients in Group B received an equal volume of normal saline. In Group A, 1 g of tranexamic acid dissolved in 250 ml of normal saline was intravenously infused before deflation of the tourniquet; another intravenous administration of the same drug of the same dosage was given 3 hours later. In Group B, only 250 ml of normal saline was infused intravenously. The amounts of blood loss and blood transfusion during operation and after operation in all the 102 patients were recorded. They were also observed for whether they had deep vein thrombosis. D-dimeride, fibrinogen, prothrombin time, and activated partial thromboplastin time were also examined before operation, during operation (deflation of the tourniquet), and 3 hours after operation.Results The blood loss was 256±149 ml in Group A and 306±214 ml in Group B during operation; there was no significant difference between the two groups(P>0.05). The postoperative drainage volume was 478±172 ml in Group A and 814±156 ml in Group B, and the total blood loss was 559±159 ml in Group A and 1.208±243 ml in Group B; there were significant differences between the two groups (P<0.05). The averaged amount of blood transfusion was 556±174 ml in Group A and 1 024± 278 ml in Group B; there was a significant difference between the two groups (P<0.05). The postoperative hemoglobin concentration was higher in GroupA than that in Group B (1.0-1.1 g/dL vs. 0.6-0.8 g/dL). The ostoperative follow-up for 612 months revealed that no deep vein thrombosis was found in both lower limbs of the patients by the color Doppler ultrasonography. The level of D-dimeride was significantly higher 3 hours after operation than before operation (0.92±0.56 mg/L vs. 0.35±0.13 mg/L in Group A; 1.32±0.79 mg/L vs. 0.37± 0.21 mg/L in Group B) (P<0.05). The D-dimeride level 3 hours after operation was significantly higher n Group B than in Group A(P<0.05). There were no significant differencesin the levels of fibrinogen, prothrombin time, and activated partial thromboplastin time between the two groups(P>0.05).Conclusion During and after the TKA operation, a shortterm use of tranexamic acid can significantly decrease blood loss and blood transfusion with no increasing risk for venous thrombosis.
ObjectiveTo summarize research progress of the effect of knee flexion position on postoperative blood loss and knee range of motion (ROM) after total knee arthroplasty (TKA).MethodsThe relevant literature at home and abroad was reviewed and summarized from mechanism, research status, progress, and clinical outcome. The differences of clinical results caused by different positions, flexion angles, and keeping time were compared.ResultsKeeping knee flexion after TKA can reduce postoperative blood loss through the angle change of blood vessels and increase knee early ROM by improving flexion muscle strength. When the flexion angle of the knee is large and the flexion position is keeping for a long time, the postoperative blood loss and the knee ROM can be significantly improved. However, the amount of blood loss and ROM are not further improved in the patients with keeping knee flexion for more than 24 hours compared with less than 24 hours.ConclusionKeeping knee flexion after TKA is a simple and effective method to reduce postoperative blood loss and improve knee ROM. However, the optimal knee flexion angle and time are needed to be further explored.
Objective To investigate a modified robotized hydraulictensor for management of the ligament balance in the total knee arthroplasty. Methods The effect of the modified robotized hydraulic tensor on the mechanical behaviour of the ligament system balance in the total knee arthroplasty was analyzed andthe related information was obtained. Results The robotized hydraulic tensor acted as a tensorsensor system, which could assist the surgeon by providing thequantitative information to align the lower limb in extension, equalize the articular spaces in extension and flexion, balance the internal and external forces, and define the femoral component rotation, and by providing the information toplan the releasing of the soft tissues and the rotating of the femoral component. Conclusion The modified robotized hydraulic tensor can enable the surgeon to properly manage the ligament balance in the total knee arthroplasty.
Objective To develop a neural network architecture based on deep learning to assist knee CT images automatic segmentation, and validate its accuracy. Methods A knee CT scans database was established, and the bony structure was manually annotated. A deep learning neural network architecture was developed independently, and the labeled database was used to train and test the neural network. Metrics of Dice coefficient, average surface distance (ASD), and Hausdorff distance (HD) were calculated to evaluate the accuracy of the neural network. The time of automatic segmentation and manual segmentation was compared. Five orthopedic experts were invited to score the automatic and manual segmentation results using Likert scale and the scores of the two methods were compared. Results The automatic segmentation achieved a high accuracy. The Dice coefficient, ASD, and HD of the femur were 0.953±0.037, (0.076±0.048) mm, and (3.101±0.726) mm, respectively; and those of the tibia were 0.950±0.092, (0.083±0.101) mm, and (2.984±0.740) mm, respectively. The time of automatic segmentation was significantly shorter than that of manual segmentation [(2.46±0.45) minutes vs. (64.73±17.07) minutes; t=36.474, P<0.001). The clinical scores of the femur were 4.3±0.3 in the automatic segmentation group and 4.4±0.2 in the manual segmentation group, and the scores of the tibia were 4.5±0.2 and 4.5±0.3, respectively. There was no significant difference between the two groups (t=1.753, P=0.085; t=0.318, P=0.752). Conclusion The automatic segmentation of knee CT images based on deep learning has high accuracy and can achieve rapid segmentation and three-dimensional reconstruction. This method will promote the development of new technology-assisted techniques in total knee arthroplasty.
Objective To analyze the effect of arteriovenous impulse system (AVIS) combined with lowmolecular-weight heparins calcium (LMWHC) for prophylaxis of deep vein thrombosis (DVT) following total knee arthroplasty (TKA). Methods From March 2006 to March 2008, 76 cases of osteoarthritis patients (76 knees) accepted TKA, including 25 males and 51 females with an average age of 66.6 years (range, 58-79 years). The affected knees were left side in 41 cases and right side in 35 cases. They were randomly divided into experimental group and control group before surgery. Then LMWHC and rehabil itation training were routinely given in two groups before and after surgery. However, only experimental group was treated with AVIS continually during the first four days and then two times a day for 30 minutes one time during 5-7 days. At 7 daysd after operation, color Doppler ultrasound was used to detect the occurrence condition of DVT. Results Five cases (13.16%) had thrombosis of calf and recovered after treated with urokinase and salvia in the experimental group. Eleven cases had thrombosis of calf and 3 cases had thrombosis of whole low extremities (36.84%), and improved after treated with urokinase and salvia in the control group. There was significant difference in DVT incidencerate between two groups (P lt; 0.05). No pulmonary embol ism or death was found in both groups. Conclusion AVIScan effectively accelerate the venous blood return velocity, a combination of AVIS and LMWHC has a better effect in theprevention of DVT following TKA.
ObjectiveTo investigate the effectiveness of digital three-dimensional (3D) printing osteotomy guide plate assisted total knee arthroplasty (TKA) in treatment of knee osteoarthritis (KOA) patients with femoral internal implants. Methods The clinical data of 55 KOA patients who met the selection criteria between July 2021 and October 2023 were retrospectively analyzed. Among them, 26 cases combined with femoral implants were treated with digital 3D printing osteotomy guide plate assisted TKA (guide plate group), and 29 cases were treated with conventional TKA (control group). There was no significant difference in gender, age, body mass index, side, Kellgren-Lawrence classification, preoperative visual analogue scale (VAS) score, Hospital for Special Surgery (HSS) knee score, knee range of motion, and other baseline data between the two groups (P>0.05). The operation time, intraoperative blood loss, incision length, postoperative first ambulation time, surgical complications; VAS score, knee HSS score, knee range of motion before operation, at 1 week and 3 months after operation, and at last follow-up; distal femoral lateral angle, proximal tibial medial angle, hip-knee-ankle angle and other imaging indicators at last follow-up were recorded and compared between the two groups. ResultsThe operation time, incision length, intraoperative blood loss, and postoperative first ambulation time in the guide plate group were significantly lower than those in the control group (P<0.05). In the control group, there were 1 case of incision rupture and bleeding and 1 case of lower limb intermuscular venous thrombosis, which was cured after symptomatic treatment. There was no complication such as neurovascular injury, incision infection, or knee prosthesis loosening in both groups. Patients in both groups were followed up 12-26 months, with an average of 16.25 months. The VAS score, HSS score, and knee range of motion improved at each time point after operation in both groups, and further improved with time after operation, the differences were significant (P<0.05). The above indicators in the guide plate group were significantly better than those in the control group at 1 week and 3 months after operation (P<0.05), and there was no significant difference between the two groups at last follow-up (P>0.05). At last follow-up, the distal femoral lateral angle, the proximal tibial medial angle, and the hip-knee-ankle angle in the guide plate group were significantly better than those in the control group (P<0.05). Conclusion The application of digital 3D printing osteotomy guide plate assisted TKA in the treatment of KOA patients with femoral implants can simplify the surgical procedures, overcome limitations of conventional osteotomy guides, reduce surgical trauma, achieve individualized and precise osteotomy, and effectively restore lower limb alignment and knee joint function.
ObjectiveTo compare the early clinical outcome of GenesisⅡ high-flexion versus standard prostheses in total knee arthroplasty (TKA), and evaluate whether high-flexion prostheses can improve the postoperative range of motion (ROM). MethodsBetween September 2007 and December 2011, 80 patients (85 knees) consecutively underwent posterior cruciate-sacrificing TKA with GenesisⅡ systems. Finally, we reviewed 60 patients (60 knees) including 32 knees in high-flexion group and 28 knees in standard group. The follow-up time was 2.7 years in average. The postoperative knee ROM and the rate of complication of the two groups were evaluated. ResultsThe mean postoperative knee ROM of 32 knees was 112.8° in the high-flexion group and was 108.9° in the standard group. The mean postoperative HSS score was 86.6 and 84.2, respectively. The postoperative knee ROM, hospital for special surgery (HSS) score and the rate of complication did not show significant difference between the two groups. ConclusionThe high-flexion prosthesis is no better than the ordinary prosthesis in terms of the range of motion. We need more mid to long-term studies to do further research.
Objective To introduce the concept and clinical applications of rotational alignment of the femoral prosthesis in total knee arthroplasty (TKA) so as to avoide the postoperative complications caused by rotational alignment. Methods The clinical and experimental research literature about rotational alignment of the femoral prosthesis in TKA was extensively reviewed and analyzed. Results Femoral prosthesis malrotation can lead to flexion gap unbalanced and undesirable patellar track. Rotation alignment of the femoral prosthesis is defined with radiological and computer assisted technique at pre- and post-operation, which can make the rotation alignment of the femoral prosthesis and the function of the knee favorable. Conclusion In recent years, many surgical skills and new techniques of defining the rotational alignment are developed, and good clinical results are achieved.
Objective To study the effect of multi-disciplinary treatment (MDT) on the surgical efficacy and satisfaction of patients undergoing total knee arthroplasty (TKA) for the first time. Methods The clinical data of patients who underwent unilateral TKA for single-compartment osteoarthritis of the knee in the General Hospital of Ningxia Medical University between January and September 2022 were retrospectively collected and analyzed. According to whether MDT was performed on patients during the perioperative period, they were divided into MDT group and traditional group. Perioperative nutrition-related indicators, perioperative complications, total hospitalization time, Visual Analogue Scale (VAS), and Hospital for Special Surgery Knee Score (HSS) before and after surgery were detected and recorded. Results A total of 95 patients were included. Among them, there were 42 cases in the MDT group and 53 cases in the traditional group. The postoperative complications and total hospital stay of patients in the MDT group were lower than those in the traditional group, and their satisfaction scores were higher than those in the traditional group (P<0.05). The perioperative serum total protein (TP), hemoglobin (Hb), serum albumin (ALB) levels, VAS score, and HSS score of both groups of patients changed over time. The intra group comparison results showed that compared with preoperative, the levels of TP, Hb, and ALB in both groups decreased on the 1st and 3rd postoperative days (P<0.05). On the 3rd day after surgery, the levels of TP, Hb, ALB in the MDT group and Hb, ALB in the traditional group were lower than on the 1st day after surgery (P<0.05). There was no statistically significant difference in TP levels between the traditional group on the 3rd day after surgery and the 1st day after surgery (P>0.05). The results of intra group comparison at different time points showed that there were statistically significant differences in VAS score and HSS score between the two groups (P<0.05). Conclusion The application of MDT in elderly patients undergoing unilateral TKA for the first time can shorten the total hospitalization time, reduce the incidence of perioperative complications, and improve the surgical efficacy and patient satisfaction.