west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "二叶式主动脉瓣" 17 results
  • Research progress of application of transcatheter aortic valve replacement in the bicuspid aortic valve stenosis

    Patients with bicuspid aortic valve (BAV) are characterized by asymmetric anatomy, severe calcification and combined aortic dilatation. Compared with tricuspid aortic valve stenosis patients, patients with BAV stenosis confront with greater surgical risks in transcatheter aortic valve replacement (TAVR), including paravalvular leak, aortic valve rupture, coronary artery obstruction, atrioventricular block and so on. However, with the advent of new generation of prosthetic valves and optimization of surgical strategies, several studies have shown that TAVR is safe and effective in the treatment of BAV stenosis. Therefore, we aim to provide an overview of the use of TAVR in patients with BAV stenosis.

    Release date:2023-07-25 03:57 Export PDF Favorites Scan
  • A case report of transcatheter aortic valve replacement for horizontal heart with aortic stenosis

    A 78-year-old female patient was admitted to West China Hospital of Sichuan University because of “amaurosis and polypnea for 4+ years”. The examination results before admission showed that severe stenosis of aortic valve, bicuspid aortic valve malformation, severe horizontal heart with 61.54° aortic angle. The preoperative evaluation of the patient indicated that the Society of Thoracic Surgeons score was 17.9%, which was high risk for surgery. After discussion by the heart team, the aortic stenosis was finally relieved by transcatheter aortic valve replacement. The operation was successfully completed by using the method of pulling and releasing the device with the same side basket. One month follow-up showed that the patient’s condition was stable and no complications occurred. This case aims to provide a reference for the treatment of horizontal heart with aortic stenosis. In the future, it is hoped that through continuous clinical practice, such patients will be provided with a safer and more efficient treatment plan.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan
  • Surgical Treatment of Dilated Ascending Aorta in Bicuspid Aortic Valve Patients: Repair or Replacement of the Ascending Aorta?

    ObjectiveTo compare the recent and mid-term results of two different treatments in bicuspid aortic valve (BAV) patients with dilated ascending aorta. MethodsFrom march 2007 to April 2014, there were totally 70 BAV patients received surgical treatment in Nanjing Cardiovascular Disease Hospital. According to the procedure of the ascending aorta, they were divided into two groups. As for group A which repaired the ascending aorta, there were 28 males and 9 females with an average age of 58.68±8.01 years. As for group B which replaced the ascending aorta, there were 25 males and 8 females with an average age of 54.18±11.97 years. And we compared perioperative clinical data and follow-up results of these two groups. ResultsThere were statistical differences between the two groups in cardiopulmonary bypass time, aortic cross clamping time, and ICU stay time (105.19±11.17 min vs. 180.94±32.10 min, P=0.000; 78.65±13.18 min vs. 110.24±29.64 min, P=0.000; 1.62±1.09 d vs. 3.58±2.89 d, P=0.001). And the time of the group A is shorter than that in the group B. Two patients in the group B died postoperatively, and the other 68 patients discharged. There was no significant difference in cumulative survival rate between the two groups (P=0.582). Postoperative following-up results showed that the ascending aortic diameter of both groups was smaller than that during the preoperative period. And at the latest time of the following-up, ascending aortic diameter was increased compared with pre-discharge in the group A (38.50±1.77 mm vs. 34.85±1.53 mm, P=0.007). But there was no increase in the group B. ConclusionWe suggests simultaneous treatment to dilated ascending aorta for BAV patients. Both the repair and replacement procedure could achieve satisfactory recent and mid-term results.

    Release date: Export PDF Favorites Scan
  • Complications in a case of functional bicuspid aortic valve treated with transcatheter aortic valve replacement

    This paper reports a case of severe stenosis and calcification of functional bicuspid aortic valve treated with transcatheter aortic valve replacement (TAVR). Before the operation, echocardiography and multi-detector computed tomography were used to evaluate the ascending aorta, coronary artery, iliac artery anatomy, valve morphology, and valve calcification. During the operation, femoral artery perforation occurred after suturing the puncture site. The treatment of compression and hemostasis with peripheral balloon was performed. After the operation, neuropsychiatric symptoms appeared. The result of brain MRI indicated multiple acute cerebral infarction. Anticoagulant, antiplatelet, and neurotrophic drugs were used. After 1-year follow-up, echocardiography showed a little reflux signal around the artificial aortic valve, and the patient’s nervous system examination showed no obvious abnormality. TAVR indications will continue to expand in the near future with the innovation of evaluation, devices, and technology. The summary of operation data can promote progress of TAVR and reduce the occurrence of complications.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan
  • Multidetector CT characteristics of bicuspid aortic valve before transcatheter aortic valve replacement in single center

    ObjectiveTo explore the preoperative evaluation result of multidetector computed tomography (MDCT) in aortic stenosis (AS) patients with bicuspid aortic valve (BAV) undergoing transcatheter aortic valve replacement (TAVR) in order to summarize relevant experience.MethodsA total of 33 consecutive AS patients who underwent TAVR in Department of Cardiology, First Affiliated Hospital of Xinjiang Medical University from March 2016 to June 2020 were enrolled, and the preoperative evaluation characteristics of MDCT were compared between tricuspid aortic valve (TAV) and BAV.ResultsIn the 33 patients, whose mean age was (74±6) years, 22 were male and 11 were female, 17 were with BAV and 16 were with TAV. The medium (lower quartile, upper quartile) of calcification score was 360 (192, 1 034) mm3. There were 12 cases of artificial valve model to be speculated Downsize, including 9 calcific BAV cases (75%).ConclusionThe calcific BAV has a higher ratio of Downsize in the TAVR procedure.

    Release date:2020-10-26 03:00 Export PDF Favorites Scan
  • 心尖途径经导管主动脉瓣置换术治疗二叶式主动脉瓣狭窄一例

    Release date:2019-01-03 04:52 Export PDF Favorites Scan
  • Establishment of large animal model of bicuspid aortic valve

    ObjectiveTo discuss the feasibility of establishment of animal model of "functional" bicuspid aortic valve with swine and observe its effect on the wall shear stress inside the aorta. MethodsFour common Shanghai White Swine with body weight between 50 kg to 55 kg were selected. Under general anesthesia and cardiopulmonary bypass, the aortic transverse incision approach was used, continuous suture with 6-0 polypropylene to align the left and right coronary valve leaflets to create a bicuspid valve morphology. After the operation, echocardiography was used to observe the aortic valve morphology and the hemodynamic changes of the aortic valve orifice. The effect on the wall shear stress inside the aorta was studied with 4D-Flow magnetic resonance imaging (MRI). ResultsA total of 4 swine "functional" bicuspid aortic valve models were established, with a success rate of 100.0%. Echocardiography showed that the blood flow velocity of the aortic valve orifice was faster than that before the operation (0.96 m/s vs. 1.80 m/s). 4D-Flow MRI showed abnormally increased wall shear stress and blood flow velocity in the aorta of the animal models. After the surgery, in model animals, the maximal wall shear stress inside the ascending aorta was greater than 1.36 Pa, and the maximum blood flow velocity was greater than 1.4 m/s. ConclusionEstablishment of the animal model of "functional" bicuspid aortic valve in swine is feasible, scientific and reliable. It can be used in researches on evaluating the pathophysiological changes.

    Release date:2022-11-22 02:01 Export PDF Favorites Scan
  • Comparing clinical outcomes between bicuspid and tricuspid aortic valve stenosis after transcatheter aortic valve replacement: A systematic review and meta-analysis

    ObjectiveTo compare the clinical outcomes of bicuspid aortic valve stenosis (BAV) and tricuspid aortic valve stenosis (TAV) after transcatheter aortic valve replacement (TAVR).MethodsA computer-based search in PubMed, EMbase, The Cochrane Library, CBM, CNKI and Wanfang databases from their date of inception to March 2019 was conducted. Two reviewers independently screened the articles, extracted data and evaluated their quality. RevMan 5.3 and Stata 15.0 softwares were used for meta-analysis.ResultsThe selected 15 cohort studies contained 45 770 patients, including 1 500 of BAV patients and 44 270 of TAV patients. The results showed that no statistical difference was found in postoperative in-hospital mortality [OR=1.29, 95%CI (0.91, 1.83), P=0.15], 30-day mortality [OR=1.23, 95%CI (0.86, 1.77), P=0.25], and 1-year mortality [OR=1.14, 95%CI (0.87, 1.50), P=0.33] between the two groups. The surgical success rate [OR=0.57, 95%CI (0.44, 0.74), P<0.01], postoperative bleeding events [OR=0.72, 95%CI (0.58, 0.91), P<0.01] and postoperative vascular injury [OR=0.68, 95%CI (0.47, 0.97), P=0.03] of patients in the BAV group were lower than those in the TAV group. The incidence of paravalvular leak in the BAV group was higher than that in the TAV group [OR=1.47, 95%CI (1.13, 1.90), P<0.01]. No significant difference was found between the two groups in terms of conversion to surgery, postoperative myocardial infarction, postoperative renal failure, postoperative neurologic events, postoperative valve gradient difference and pacemaker implantation.ConclusionCompared with TAV, the application of TAVR in BAV patients is feasible and effective.

    Release date:2020-06-29 08:13 Export PDF Favorites Scan
  • Transapical transcatheter aortic valve replacement in bicuspid aortic valve patients: In-hospital outcomes

    ObjectiveTo compare the in-hospital outcomes of transapical transcatheter aortic valve replacement (TA-TAVR) for bicuspid aortic valve (BAV) patients and tricuspid aortic valve (TAV) patients. MethodsPatients (including BAV and TAV patients) who underwent TA-TAVR with the J-ValveTM in West China Hospital from July 2014 to July 2020 were included consecutively. The clinical outcomes of the patients were analyzed. ResultsA total of 354 patients were included in the study, 75 in the BAV group and 279 in the TAV group. There were 229 males and 125 females with a mean age of 72.2±6.0 years. No death occurred during the procedure, and the overall technical success rate was 97.7%. The all-cause in-hospital mortality rate was 1.4%. Twenty (26.7%) patients with BAV and 46 (16.5%) patients with TAV had mild or higher perivalvular leaks immediately after the procedure. No patients with BAV required permanent pacemaker implantation postoperatively, while 13 (4.7%) TAV patients required permanent pacemaker implantation, with an overall pacemaker implantation rate of 3.7%. One (1.3%) BAV patient and 7 (2.5%) TAV patients developed acute kidney injury postoperatively. One (1.3%) BAV patient and 1 (0.4%) TAV patient developed perioperative myocardial infarction. The average postoperative hospital stay was 7.6±3.6 d for BAV patients and 8.6±6.1 d for TAV patients. There was no statistical difference in primary or secondary in-hospital outcomes between BAV and TAV patients (P>0.05). ConclusionCompared to TAV patients, BAV patients have similar in-hospital outcomes, with a low incidence of adverse clinical outcomes, which provides preliminary evidence for its implementation in Chinese patients with a high proportion of BAV.

    Release date:2023-07-25 03:57 Export PDF Favorites Scan
  • Bioinformatics analysis for bicuspid aortic valve with ascending aorta dilation

    Objective To explore the key genes, pathways and immune cell infiltration of bicuspid aortic valve (BAV) with ascending aortic dilation by bioinformatics analysis. Methods The data set GSE83675 was downloaded from the Gene Expression Omnibus database (up to May 12th, 2022). Differentially expressed genes (DEGs) were analyzed and gene set enrichment analysis (GSEA) was conducted using R language. STRING database and Cytoscape software were used to construct protein-protein interaction (PPI) network and identify hub genes. The proportion of immune cells infiltration was calculated by CIBERSORT deconvolution algorithm. Results There were 199 DEGs identified, including 19 up-regulated DEGs and 180 down-regulated DEGs. GSEA showed that the main enrichment pathways were cytokine-cytokine receptor interaction, pathways in cancer, regulation of actin cytoskeleton, chemokine signaling pathway and mitogen-activated protein kinase signaling pathway. Ten hub genes (EGFR, RIMS3, DLGAP2, RAPH1, CCNB3, CD3E, PIK3R5, TP73, PAK3, and AGAP2) were identified in PPI network. CIBERSORT analysis showed that activated natural killer cells were significantly higher in dilated aorta with BAV. Conclusions These identified key genes and pathways provide new insights into BAV aortopathy. Activated natural killer cells may participate in the dilation of ascending aorta with BAV.

    Release date:2022-09-30 08:46 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content