west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "主动脉瓣反流" 32 results
  • Transcatheter aortic valve implantation for native aortic valve regurgitation: A systematic review and meta-analysis

    Objective To evaluate the efficacy of transcatheter aortic valve implantation (TAVI) for native aortic valve regurgitation. MethodsLiterature from The Cochrane Library, PubMed, EMbase, Cochrane Controlled Trials Registry, ClinicalTrials.gov and China Biomedical Literature Database from January 2002 to May 2021 were searched by computer. The literature on TAVI or transcatheter aortic valve replacement treatment for simple aortic reflux were collected. Two reviewers independently screened the literature according to the inclusion and exclusion criteria, extracted data, and assessed the quality of the literature. Meta-analysis was performed using STATA 14.0 software. ResultsA total of 15 studies including 1 394 patients were included. The Newcastle-Ottawa Scales of the studies were≥6 points. The success rate of prosthetic valve implantation was 72.0%-100.0%, and there was no report of serious complications such as surgical death, myocardial infarction, and valve annulus rupture. The 30-day all-cause mortality rate was 6.3% [95%CI (3.4%, 9.1%)]. The incidence of stroke within 30 days and the rate of postoperative permanent pacemaker implantation were 2.0% [95%CI (1.0%, 4.0%)] and 6.0% [95%CI (4.0%, 10.0%)], respectively, and were both within acceptable limits. ConclusionFor patients with simple high-risk aortic regurgitation, TAVI can obtain satisfactory treatment effects and has low postoperative complications rate, and it may be a potential treatment option for such patients.

    Release date:2023-03-01 04:15 Export PDF Favorites Scan
  • Procedure specifications for transapical transcatheter aortic valve replacement

    Transcatheter aortic valve replacement (TAVR) techniques have been rapidly developed in recent years. Current guidelines and studies mainly focus on aortic stenosis patients treated by transfemoral approach, but they are not completely appropriate to patients with isolated aortic regurgitation or other patients who need transapical TAVR (TA-TAVR), which affects the standardized treatment of those patients. Therefore, our team pronounced the operational standards for TA-TAVR, based on fully reviewing the literatures worldwide, combined with the opinions of experts from 15 heart centers with rich experience in carrying out TA-TAVR in China. This standard aims to provide clinicians with standardized diagnosis and treatment principles of TA-TAVR and improve the quality of TA-TAVR in China.

    Release date:2023-03-24 03:15 Export PDF Favorites Scan
  • Transcatheter valve implantation for aortic and tricuspid valve regurgitation: A case report

    Transcatheter aortic valve implantation (TAVI) is an important alternative in treating high-risk patients with aortic valve regurgitation. Transcatheter tricuspid valve implantation (TTVI) is also an important treatment option for high-risk patients with tricuspid regurgitation. We reported a 72-year male patient who underwent TAVI due to severe aortic valve regurgitation using a J-Valve. During a two-year follow-up, the patient developed secondary tricuspid regurgitation to atrial fibrillation, and subsequently received TTVI using a LuX-Valve. Following the interventions, the patient's symptoms were significantly improved, and echocardiography indicated good hemodynamic performance of both transcatheter heart valves. This case highlights the feasibility and effectiveness of performing multiple valve implantations via transcatheter approaches in high-risk elderly patients.

    Release date:2024-05-28 03:37 Export PDF Favorites Scan
  • Research progress of transcatheter aortic valve replacement-related new valve prostheses

    Transcatheter aortic valve replacement has revolutionized the management of aortic stenosis and become the gold standard for the treatment of symptomatic and severe aortic valve stenosis in elderly patients. With the improvement in design and materials, newer generation transcatheter aortic valve prostheses had overcome the limitations of early-generation devices that were susceptible to paravalvular leak, atrioventricular block and vascular complications, to a certain extent. This review provides an update on the latest advances in transcatheter aortic valve prostheses.

    Release date:2023-09-28 02:17 Export PDF Favorites Scan
  • 应用 J-valve 瓣膜经心尖途径治疗超高龄单纯性主动脉瓣重度反流一例

    Release date:2019-05-28 09:28 Export PDF Favorites Scan
  • Transcatheter aortic valve replacement for aortic regurgitation complicated by Takayasu arteritis: A case report

    Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up period. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.

    Release date: Export PDF Favorites Scan
  • Advances in transcatheter aortic valve replacement for pure native aortic regurgitation

    Transcatheter aortic valve replacement (TAVR) has been confirmed to be safety and efficacy for high-risk elderly aortic stenosis, and the clinical effect of TAVR for medium and low-risk aortic stenosis is not worse than that of surgery. The development of surgical techniques and instruments has made cardiologists attempt to broaden the surgical indications. Many elderly and high-risk patients with pure native aortic regurgitation have been treated “off label” with similar techniques, completing artificial valve replacement, restoring valve function and improving the prognosis. However, due to the high requirements of surgical techniques and surgical complications, there is a lack of randomized controlled studies to confirm its safety and effectiveness. Unlike aortic stenosis, native aortic regurgitation presents unique challenges for transcatheter valves. In this article, the authors review current advances in the treatment of aortic valve regurgitation with TAVR.

    Release date:2019-12-13 03:50 Export PDF Favorites Scan
  • The clinical effect of a combined technical system for bicuspid aortic valves repair

    ObjectiveTo summarize the clinical result of a combined technical system for bicuspid aortic valve (BAV) repair. MethodsPatients who diagnosed as BAV and sever aortic regurgitation (AR) underwent a strategy of combined repair technics including annuloplasty, sinus plasty, leaflet plasty, sinus-tubular junction (STJ) plasty depending on anatomy pathological characteristics between October 2019 and January 2021 were enrolled. The clinical data of the patients were analyzed.ResultsA total of 17 patients were enrolled. There were 11 males and 6 females with an average age of 18-49 (32.4±13.6) years. Fifteen patients had typeⅠand 2 patients had typeⅡBAV according to Sievers classification. Annuloplasty was applicated in 13 patients, sinus plasty in 8 patients, leaflet plasty in 17 patients, and STJ plasty in 11 patients, respectively. The cardiopulmonary bypass (CPB) time was 95 (84, 135) min, aortic cross-clamping time was 68 (57, 112) min, and the ICU stay time was 17 (12, 25) h. After the operation, mild AR was presented in 14 patients, moderate AR in 1 patient and severe AR in 2 patients. The latter 3 patients underwent second operation under CPB, after then, 1 patient had mild AR and 2 patients had moderate AR. The follow-up time was 13.1±4.6 months. At the latest follow-up, 12 patients had mild AR and 5 patients had moderate AR, and no patient had reoperation. ConclusionA combined technical system for BAV repair can be used effectively and safely with an acceptable short and middle-term result.

    Release date:2023-07-10 04:06 Export PDF Favorites Scan
  • Midterm outcomes of valve-sparing aortic root replacement in patients with aortic root aneurysm and moderate to severe aortic regurgitation

    ObjectiveTo evaluate the midterm effect of valve-sparing aortic root replacement (VSRR) on aortic root aneurysm and moderate to severe aortic regurgitation (AR). MethodsThe clinical data of patients with aortic root aneurysm and moderate to severe AR undergoing VSRR and surviving from the operation from October 2013 to May 2020 were retrospectively analyzed. There were 31 males and 9 females, with an average age of 47.1±13.4 years. There were 30 patients with true aneurysm of aortic root and 10 patients with dissecting aneurysm of aortic root. There were 3 patients with bicuspid aortic valve, and 12 patients with Marfan syndrome. The AR measured by the echocardiogram was moderate in 18 patients and severe in 22 patients. The average diameter of aortic annulus was 27.0±3.9 mm, and the mean largest diameter of aortic sinus was 52.3±6.1 mm. ResultsA total of 32 patients underwent David technique and 8 patients underwent Yacoub technique, and 10 patients underwent aortic cusp repair simultaneously. All 40 patients completed the follow-up, and the follow-up period was 12-86 (45.7±18.9) months. During the period, 1 patient died of heart failure, 2 had reoperation due to new-onset Stanford B aortic dissection, and no patients had reoperation related to aortic valve. The postoperative New York Heart Association cardiac function classification (1.6±0.5 vs. 2.8±0.8), left ventricular end-diastolic dimension (52.2±7.8 mm vs. 61.4±10.6 mm) and left ventricular end-diastolic volume (136.0±58.8 mL vs. 193.3±83.9 mL) of the patients were significantly improved compared with preoperative ones (P<0.05). By echocardiography, 19 patients had no AR, 18 patients had mild AR, 3 patients had mild-moderate AR, and no patients had moderate or higher AR. ConclusionIn patients with aortic root aneurysm and moderate to severe AR, VSRR technique avoids prosthetic valves and anticoagulation-related complications, has lower rate of AR recurrence and reoperation, and improves the quality of life in the midterm period.

    Release date:2022-08-25 08:52 Export PDF Favorites Scan
  • Mid-to-long term fate of neo-aortic root after arterial switch operation for Taussig-Bing anomaly: A retrospective study in a single center

    ObjectiveTo explore growth pattern of neo-aortic root as well as development of neo-aortic regurgitation after arterial switch operation (ASO) for Taussig-Bing anomaly. MethodsFrom 2002 to 2017, the patients who received ASO, and were discharged alive from Shanghai Children’s Medical Center and followed up for more than 3 years were retrospectively involved in this study. ResultsA total of 127 patients were enrolled. There were 98 (77.2%) males, the median age at ASO was 73.0 d and the average weight was 4.7 kg. Forty-five (35.4%) children were complicated with mild or mild-to-moderate pulmonary insufficiency (PI) before ASO. The average follow-up time was 7.0 years. During the follow-up, 14 (11.0%) children presented moderate or greater neo-aortic regurgitation (neo-AR). The diameter of neo-aortic annulus and sinus of Valsalva was beyond normal range during the entire follow-up. The average diameter of neo-aortic annulus was 18.0 mm at 5 years and 20.5 mm at 10 years. The average diameter of sinus of Valsalva was 25.9 mm at 5 years and 31.1 mm at 10 years. Neo-AR continued to develop over time. The diameter of children who developed moderate or greater neo-AR was constantly larger than that of children who did not (χ2=18.3, P<0.001). Preoperative mild or mild-to-moderate PI was an independent risk factor for the development of moderate or greater neo-AR during mid-to-long term follow-up (c-HR=3.46, P=0.03). ConclusionThe diameters of neo-aortic annulus and sinus of Valsalva of Taussig-Bing children who receive ASO repair continue to expand without normalization. The dilation of annulus correlates with the development of neo-AR. PI before ASO repair increases the risk of neo-AR development.

    Release date:2024-04-28 03:40 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content