ObjectiveTo explore the application value of multidisciplinary collaborative team (MDT) model in retroperitoneal tumors involving large vessels.MethodsThree cases of retroperitoneal tumors involving great vessels admitted to Xiang’an Hospital of Xiamen University in 2019 were retrospectively analyzed. With the support of 3D visual reconstruction and virtual reality (VR) technology, we performed MDT discussion and three cases received treatment of surgery, intervention, and targeted therapy.ResultsCase 1 was discussed by MDT and concluded that, based on CT examination, 3D reconstruction, and VR virtual image results, the tumor on the right side was determined to be completely resectable. The left tumor was judged to be unresectable, and the proposed treatment plan was right metastatic tumor resection + left metastatic tumor radiofrequency ablation. After surgery case 1 had been followed up for 6 months. The symptoms of diarrhea were significantly improved. CT reexamination showed that liver lesions and left retroperitoneal lesions were the same size and the condition was stable. After discussion by MDT, radiofrequency ablation around the tumor was proposed for case 2. This case was followed up for 3 months after surgery, and CT reexamination showed no new lesion in retroperitoneum. After MDT discussion, we concluded that arteriovenous fistula of case 3 had no indications for surgery, and proposed interventional combined with targeted therapy. After treatment, the tumor was found to be smaller after reexamination in 8 months than before treatment, and the efficacy was evaluated as partial remission. The follow-up was continued.ConclusionThe future development trend of retroperitoneal tumor therapy involving great vessels is to evaluate each patient’s condition under the MDT mode by using 3D visual reconstruction and VR technology, and to formulate the individualized treatment plan of operation combined with other treatments.
ObjectiveTo explore the feasibility of three-dimensional (3-D) visualization reconstruction of the medial sural artery perforator flap based on digital technology. MethodsA series of Dicom images were obtained from three healthy adult volunteers by dual source CT angiography. Then the Mimics software was used to construct the medial sural artery model and measure the indexes, including the starting position of medial sural artery, external diameters of vascular pedicle, the number of perforators, location perforated deep fascia, and the maximum pedicle length of perforators based on medial sural artery perforator flap. ResultsThe 3-D visualization reconstruction models were successfully finished with Mimics software, which can clearly display the distribution, travel, and perforating point. Thirteen perforators were found in 6 legs, which started at the popliteal artery with a mean external diameter of 2.3 mm (range, 1.9-2.7 mm). Each specimen had 1-3 perforators, which located at the site of 6.2-15.0 cm distal to popliteal crease and 2.5-4.2 cm from posterior midline. The maximum pedicle length of medial sural artery perforator flap was 10.2-13.8 cm (mean, 11.8 cm). ConclusionThe 3-D visualization reconstruction models based on digital technology can provide dynamic visualization of the anatomy of the medial sural artery for individualized design of the medial sural artery perforator flap.
ObjectiveTo comprehend the current diagnosis status and new progress of hepatic echinococcosis (HE). MethodThe literature from domestic and foreign researchers relevant diagnosis of HE in recent years was searched and summarized. ResultsThe HE was widely distributed worldwide, with extremely high mortality and disability rates, posing a serious threat to local economic development and public health. At present, in addition to the traditional and widely recognized diagnostic methods based on epidemiological histories, clinical manifestations, routine imaging, and experimental examinations, many innovative technologies based on these traditional diagnostic methods had emerged in the field of HE diagnosis, such as diagnostic prediction models constructed based on ultrasound and other imaging data, artificial intelligence, three-dimensional visual reconstruction, and circulating free DNA testing, which significantly improved the diagnosis rate of the HE. ConclusionsIn recent years, with the continuous improvement of medical level, the in-depth and perfect exploration of HE has made remarkable progress, which not only provides a new possibility for the early diagnosis of the HE, but also provides an important basis for research in related fields and the formulation of prevention and control measures. Therefore, the further promotion and application of these new techniques will aid to promote the diagnosis progress of HE and reduce its impact on population health.
The aim of this study was to propose an algorithm for three-dimensional projection onto convex sets (3D POCS) to achieve super resolution reconstruction of 3D lung computer tomography (CT) images, and to introduce multi-resolution mixed display mode to make 3D visualization of pulmonary nodules. Firstly, we built the low resolution 3D images which have spatial displacement in sub pixel level between each other and generate the reference image. Then, we mapped the low resolution images into the high resolution reference image using 3D motion estimation and revised the reference image based on the consistency constraint convex sets to reconstruct the 3D high resolution images iteratively. Finally, we displayed the different resolution images simultaneously. We then estimated the performance of provided method on 5 image sets and compared them with those of 3 interpolation reconstruction methods. The experiments showed that the performance of 3D POCS algorithm was better than that of 3 interpolation reconstruction methods in two aspects, i.e. subjective and objective aspects, and mixed display mode is suitable to the 3D visualization of high resolution of pulmonary nodules.
Objective To realize the visualization of three-dimensional microstructure of rabbit sciatic nerve bundles by micro-CT and three-dimensional visualization software Mimics17.0. Methods The sciatic nerve tissues from 6 New Zealand rabbits were divided into 2 groups (n=3), and the sciatic nerve tissues were stained by 1% (group A) and 5% (group B) Lugol solution respectively. After staining for 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, and 3.5 hours, the imaging changes of specimens were observed by light microscope and micro-CT. The clear micro-CT images were exported to the Mimics software to complete the visualization of three-dimensional microstructure of rabbit sciatic nerve according to three-dimensional reconstruction tool. Results The clear three-dimensional microstructure images could be observed in group A at 2.5 hours after staining and in group B at 1.5 hours after staining by light microscope and micro-CT. The sciatic nerve of New Zealand rabbits were divides into 3 bundles and each of them was relatively fixed. There was no obvious crossing or mergers between each bundle. The cross-sectional area of each bundle was (0.425±0.013), (0.038±0.007), and (0.242±0.026) mm2 respectively. The digital model could clearly reflect the microstructure of the sciatic nerve at all cross sections. Conclusion The internal structure of New Zealand rabbits sciatic nerve can be clearly reflected by micro-CT scanning. It provides a reliable method for establishing a nerve microstructure database with large amount specimens.
Three-dimensional (3D) visualization technology can well characterize lung nodules, accurately locate lung nodules, accurately identify lung anatomical structures, shorten operation time, reduce intraoperative and postoperative complications, and make thoracoscopic precise lung resection safer and more efficient. However, the mastery of 3D reconstruction technology in some hospitals still needs to be improved. Due to the time and economic cost of 3D printing, the development of this technology is restricted. With the application and improvement of 3D visualization technology in more centers in the future, the development of precise lung resection will be more extensive. This article reviewed the progress on 3D visualization technology in thoracoscopic precise lung resection.
ObjectivesTo systematically review the clinical efficacy of three-dimensional (3D) visualization vs. two-dimensional (2D) imaging technique in hepatectomy.MethodsPubMed, EMbase, The Cochrane Library, CBM, CNKI, WanFang Data and VIP databases were electronically searched to collect clinical trials which compared 3D visualization with conventional 2D imaging technique for hepatectomy from inception to September 2017. Two reviewers independently screened literature, extracted data and assessed the risk bias of included studies, and then, meta-analysis was performed by using RevMan 5.3 software.ResultsA total of 11 studies involving 953 patients were included. The results of meta-analysis showed that: compared to 2D imaging technique, 3D visualization technique could improve R0 resection rate (OR=2.91, 95%CI 1.31 to 6.43, P=0.009), had lower incidence of postoperative complication (OR=0.55, 95%CI 0.38 to 0.80, P=0.002), less amount of blood transfusion in operation (MD=–96.05, 95%CI –126.78 to –65.31, P<0.000 01), lower discrepancy range between the volume of the predicted liver resection and actual resection volume (MD=–94.38, 95%CI –185.46 to –3.30,P=0.04), shorter operation time (MD=–33.58, 95%CI –60.09 to –7.08, P=0.01), and lower intraoperative blood loss (MD=–79.70, 95%CI –139.86 to –19.53, P=0.009), the differences were statistically significant. There were no statistical differences between two groups in postoperative hospital stay time (MD=–0.75, 95%CI –2.45 to 0.95, P=0.39).ConclusionsThe current evidence shows that application of 3D visualization technique in hepatectomy can predict the liver resection volume more accurately, improve the R0 resection rate, shorten operation time, decrease intraoperative blood transfusion volume and the amount of bleeding, and reduce the incidence of postoperative complications. Due to limited quality and quantity of the included studies, more high-quality studies are required to verify above conclusion.
ObjectiveTo investigate the role of 3D visualization technology in the laparoscopic precise hepatectomy. MethodsTo retrieve the literatures about the application of 3D visualization technology in laparoscopic precise hepatectomy, and summarize and analyzed them. ResultsThe application of 3D visualization in laparoscopic precise hepatectomy could effectively reduce the operative time, blood loss, blood transfusion rate, and total complication rate. The application of 3D visualization in preoperative evaluation of the resection surface and residual liver volume had been relatively mature. Although many organizations try to use 3D visualization in laparoscopic hepatectomy, such as laser registration and real-time intraoperative navigation, it had not been widely used in clinic because of technical limitations. ConclusionsExisting research results show that, the application of 3D visualization technology in laparoscopic precise hepatectomy can improve the resectability of lesions, increase perioperative safety, but intraoperative navigation is still need to be further developed before it is expected to be widely used in clinical practice. Existing evidence of increased benefit from laparoscopic precise hepatectomy with 3D reconstruction remains limited, and more rigorous randomized controlled trials of large cases are needed to confirm this.